FAIRA TRANSPARENCY REPORTS th Ave N, Seattle, WA 98109

Similar documents
FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

FAIRA TRANSPARENCY REPORTS S 284th Ln, #H204, Federal Way, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS st Ave, #605, Seattle, WA June 2 nd, 2017

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, A304, Des Moines, WA March 13, 2018

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS Wells Ct S, Renton, WA 98055

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS S 237th St, Kent, WA November 28, 2017

FAIRA TRANSPARENCY REPORTS th Pl W, Lynnwood, WA 98087

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS th Ave SE, Bothell, WA 98012

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS Chestnut Street, Everett, WA 98201

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS. 706 N 103rd St, Seattle, WA August 14, 2017

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

FAIRA TRANSPARENCY REPORTS. 553 Chelan Pl NE, Renton, WA March 3 rd, 2018

RW West Consultants. Property Inspection Report

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

FAIRA TRANSPARENCY REPORTS W James St, 8, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Arlington, WA 98223

26632 Timberlane Dr SE, Covington, WA 98042

FAIRA TRANSPARENCY REPORTS th Ave NE, Seattle, WA August 23 rd, 2017

FAIRA TRANSPARENCY REPORTS nd Ave SE, Renton, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

FAIRA TRANSPARENCY REPORTS th Ln NE, Issaquah, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

FAIRA TRANSPARENCY REPORTS Interlake Ave N, Seattle, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS st Ave SE, Renton, WA 98058

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, Des Moines, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

Amendment to the Inspection Report

FAIRA TRANSPARENCY REPORTS. 609 Union Avenue NE, Renton, WA 98059

FAIRA TRANSPARENCY REPORTS S 298th St, Auburn, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS Burke Ave N, Seattle, WA March 14, 2018

FAIRA TRANSPARENCY REPORTS W Crockett St., Seattle, WA September 5 th, 2017

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS. 808 NW 125th St, Seattle, WA February 12, 2018

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NW, Seattle, WA 98107

RW West Consultants, Inc. Property Inspection Report Inspector: Clifton Moody (Skip), RW West Consultants, Inc. Cover Page

FAIRA TRANSPARENCY REPORTS th Ave S, SeaTac, WA August 4, 2017

FAIRA TRANSPARENCY REPORTS. July 6, 2016

FAIRA TRANSPARENCY REPORTS SE 225th St, Maple Valley, WA June 2nd, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Kirkland, WA February 16, 2018

FAIRA TRANSPARENCY REPORTS NE 116th Pl, Kirkland, WA April 20 th, 2017

FAIRA TRANSPARENCY REPORTS th Pl SE, Covington, WA May 17 th, 2017

FAIRA TRANSPARENCY REPORTS rd Ave SW, Vashon, WA May 19 th, 2017

FAIRA TRANSPARENCY REPORTS Silver Springs Dr NW, Gig Harbor, WA February 20, 2018

FAIRA TRANSPARENCY REPORTS th Ave S, Seattle, WA November 9, 2017

FAIRA TRANSPARENCY REPORTS

Hearth and Homes Inspections, llc

Troy's Home Inspection Services LLC

Inspector Gadget Homes

Inside Out Home Inspections

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Extra Mile Inspection, Inc.

Cascade Inspection Services, LLC

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Canadian Property Inspections

All In One Home Inspections

Transcription:

608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98109 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/12511 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We re happy you ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Property Inspection Report Inspector: Ronald West, RW West Consultants Cover Page 98109 Inspection prepared for: Faira.com Real Estate Agent: - Date of Inspection: 7/18/2018 Time: 4:00 PM Age of Home: 1904 Size: 2500 Order ID: 4100 Inspector: Ronald West License #565 PO Box 214, Redmond, WA 98073 Phone: 425-885-0722 Email: rwwestconsultants@gmail.com RWWestInspections.com

INTRODUCTION: Inspection Details We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific non-code, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. Items denote serious, safety or items that require further investigation Items denote minor or maintenance items Items denote locations and shutoff valves 1. Attendance In Attendance: Seller present 2. Home Type Home Type: Triplex Two Story with Basement 3. Occupancy Occupancy: Occupied - Furnished Page 1 of 49

1. Exterior Note General Exterior Note 2 South Elevation 2 East Elevation 2 North Elevation Page 2 of 49

1. Siding Condition Exterior Areas Siding appeared in good condition overall. Aluminium siding noted. Decay to band at steps northeast, east side. Crawlspace is behind this area. Recommend extent of damage is investigated further and repaired 2. Gutters Gutters and downspouts appeared in good condition overall. Debris in gutters, recommend cleaning gutters. 3. Driveway and Walkway Condition Concrete sidewalks appeared in good condition overall. 4. Soffit Soffits and eaves appeared in good condition overall. Water staining at the southeast corner of front porch indicating past leaking. There has not been rain for sometime, recommend monitoring or further investigation Page 3 of 49

5. Door/Window There was no visible flashing above the windows and or doors. Windows and or doors without flashing require periodic maintenance of caulking material. Decay occurring at threshold north side. Recommend extent of damage is investigated further and repaired 6. Grading Foliage is touching the siding, recommend clearance is achieved as this is a conducive condition for wood destroying organisms and pests Grade slopes toward the house from north to south. Grade slopes toward the house from west east. Ideally 1st 6 feet should slope away when possible. 7. Electrical No power to outlet, recommend further investigation and correction. Box missing cover Page 4 of 49

8. Cable Feeds Materials: Primary Service is Overhead Service Drop 9. Exterior Faucet Condition Hose bib at east side of house leaks. Page 5 of 49

10. Retaining Wall Concrete block retaining wall. Rockery retaining wall. Retaining Walls appeared in good condition overall. Page 6 of 49

1. Storage Room Exterior Storage Room Decay occurring, structure not fully accessible, bees were in this area Page 7 of 49

1. Porch Porches Concrete porch/porches appeared in good condition Guardrail balusters/spindles are spaced further than the maximum 4 inches, this requirement is to prevent small children from fitting through guardrail. Guardrail should be installed at a height of no less than 36" to 42". Recommend conditions are corrected as a safety precaution. Guardrails lower than 36 inches encourage people to set on the guardrail Page 8 of 49

1. Stair Exterior Stairs Steps were not uniform height, normally there should be no more that a 3/8th inch variance between riser heights. Recommend using caution. Page 9 of 49

1. Roof Condition Roof Architectural Composition shingle. Walked on roof surface. Moss growth on the wood shake surface. There are also areas where shakes are split in the key/rain groove areas exposing felt paper. Strongly recommend these conditions be investigated further by licensed roofing contractor and corrected. Recommend following conditions are investigated further by licensed roofing contractor and conditions corrected as required. Granular Loss At least 2 layers of shingles present Page 10 of 49

2. Flashing Siding butted against shingles, flashing not visible Page 11 of 49

1. Attic Attic 1 2. Framing Framing appeared in good condition overall. There were no visible indications of decay. There is a whitish and or darkened coloration that possibly could be a fungal/mold growth. Conditions are generally a result of excessive moisture at some point or inadequate ventilation. Treating/remediation and correction moisture conditions will help prevent future occurrences. Testing would need to be performed to determine the presence or absence of Mold. Testing may include surface sampling and air quality testing. Page 12 of 49

3. Ventilation Roof surface vents present. Attic appeared inadequately vented. Normally vents should be placed equally at high and low areas so that cross ventilation is acheived. Recommend conditions are investigated further by licensed roofing contract and repair as necessary to ensure proper ventilation. Adding additional ventilation will help avoid premature aging of roof and help to maintain proper humidity and temperature control that could otherwise result in mold/fungus or wood decay. No eaves vents installed, recommend conditions are corrected. 4. Fan/Duct Not All Bathroom fans exhaust completely to the exterior. Typically piping should actually connect to exterior vent, recommend correction. This condition can result in mold/fungal growth. Page 13 of 49

5. Electrical Insulation has been installed over knob and tube wiring at various locations. This is a fire "Safety Concern". Strongly recommend conditions are investigated further by licensed electrical contractor prior to closing to ensure safety. Electrical tape on 1 wire north side 6. Insulation Condition Blown in fiberglass insulation noted. 7. Rodent/Pests Droppings present. Indications of Rodent activity. Some rodent droppings can carry disease, recommend conditions are investigated further by licensed Pest Control Company. Page 14 of 49

Page 15 of 49

1. General Notes General Interior Note Materials: Windows in the home are Double pane insulated glass windows. Any deficiencies are noted in each room section for accessible windows Windows in the home are single pane glass Cabinet doors and in the home are considered operational unless otherwise noted in each room section Page 16 of 49

1. Living Room Living Room Walls and ceilings appear in good condition overall. Flooring is laminate wood grain material. Heat register present. Accessible outlets operate. Page 17 of 49

1. Kitchen Room Kitchen Walls and ceilings appear in good condition overall. Flooring is Tile. Accessible outlets operate. Light fixture operates. Sink and faucets are in operable condition overall. Cabinet doors and drawers are in operable condition overall. 2. Disposal Disposal did not operate, recommend conditions are investigated further and corrected 3. Dishwasher Not operable at the time of inspection, recommend conditions are investigated further and corrected as required. 4. Floor Floor slope from west to east 5. Stove/Oven Stove/oven were in operable condition overall. Page 18 of 49

6. Refrigerator Refrigerator was in operable condition overall. 7. Electrical Freezer Refrigerator GFCI outlets have been required for Kitchens (since 1987) No GFCI protection present,, strongly recommend GFCI outlets are installed as a safety precaution. Improper electrical wiring under the sink, recommend correction by licensed electrical contractor Outlet and or Switch cover plates missing, recommend correction as a safety precaution. Page 19 of 49

8. Vent Condition Vent fan is recirculating type. Page 20 of 49

1. Conditions Hallway Ceiling and walls are in good condition overall. Light fixture operates. 2. Electrical No power to the outlet, Recommend further investigation by licensed electrician Page 21 of 49

1. Condition Laundry 2. Dryer Dryer appeared to exhaust to the exterior. Lint in dryer vent indicating possible blockage, strongly recommend cleaning as a blocked dryer vent can be a potential fire hazard. Dryer not functioning properly Page 22 of 49

3. Washer Materials: Washer appeared to be in operable condition. Washer faucets were in operable condition, no visible leakage. Page 23 of 49

1. Stair Stairs Leading to 2nd Floor Handrail appeared secure. Guardrail balusters are spaced further than newer required 4 inches. 4 inch requirement is so small children cannot fit through the guardrail. Steps were not uniform height, normally there should be no more that a 3/8th inch variance between riser heights. Recommend using caution. Page 24 of 49

1. Room Hall Bathroom1 Ceiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. 2. Electrical GFCI did not trip with tester GFCI trip test, strongly recommend conditions are investigated further and corrected by licensed electrical contractor as a safety precaution. 3. Counters Engineered Composite Vanity Top with Basin 4. Exhaust Fans Vent fan operates overall. 5. Floors Tile Flooring is in good condition overall. Floor slopes from west to easr Page 25 of 49

6. Shower Shower is in good condition overall. Shower door is in operable condition overall. 7. Sinks Sink was in operable condition overall. Sink drains slow, recommend conditions are corrected. Drain is open at the top, strongly recommend installing mechanical vent is installed to prevent sewer gas from entering in the living area 8. Toilet Toilet was in operable condition overall. Page 26 of 49

1. Bedroom Room Bedroom 1 Walls and ceilings appear in good condition overall. Flooring is laminate wood grain material. Heat register present. Accessible outlets operate. 2. Doors Closet doors not installed. 3. Heating Electric Convector heater operates. Page 27 of 49

Page 28 of 49

1. Utility Room Utility Room Flooring is concrete in good condition. Accessible outlets operate. North wall is a wood retaining wall that borders crawlspace. Wood may not be treated and decay could result Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also cause damage to insulation. Recommend conditions are investigated further by licensed Pest Control Company. 2. Electrical Outlet cover plates missing, recommend cover plates are installed. Page 29 of 49

1. Plumbing Plumbing/Water Heater1 Water lines were copper Drain and waste lines were plastic. Cleanout located exterior north side 2. Water Heater Condition Heater Type: Electric water heater. 3. Age Approximately 15 years of age, average life span is 10 to 12 years. Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring or replacement. Page 30 of 49

4. Condition Seismic straps are not in place/ improperly installed. Normally there should be seismic straps installed at the upper and lower one thirds of the tank. Expansion tank is not in place. This is a hazardous condition on closed water systems. Recommend conditions are investigated further and corrected as required by licensed plumbing contractor. 5. TPRV Condition Temperature Pressure Relief Valve (TPR Valve) present. Page 31 of 49

1. Water Heater Condition Heater Type: Electric water heater. 50 gallons Plumbing/Water Heater 2 2. Age Approximately 15 years of age, average life span is 10 to 12 years. Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring or replacement. 3. Condition Seismic straps are not in place/ improperly installed. Normally there should be seismic straps installed at the upper and lower one thirds of the tank. Expansion tank is not in place. This is a hazardous condition on closed water systems. Recommend conditions are investigated further and corrected as required by licensed plumbing contractor. Page 32 of 49

4. TPRV Condition Temperature Pressure Relief Valve (TPR Valve) present. Page 33 of 49

1. Water Heater Condition Heater Type: Electric water heater. 50 gallons Plumbing/Water Heater 3 2. Age Approximately 15 years of age, average life span is 10 to 12 years. Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring or replacement. 3. Condition Seismic straps are not in place/ improperly installed. Normally there should be seismic straps installed at the upper and lower one thirds of the tank. Expansion tank is not in place. This is a hazardous condition on closed water systems. Recommend conditions are investigated further and corrected as required by licensed plumbing contractor. Page 34 of 49

1. Location Materials: Located in the Bedroom Electrical 1 2. Electrical 125 AMP service, #2 Copper service entrance wires. 3. Grounding Electrical service is grounded and bonded. Page 35 of 49

4. Wiring Type Breaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiring is copper. Neutral busbar double taps were not allowable after 2002. Double tapping and lugging can create hot spots on breakers and neutral bars because they are not tightened to the correct torque-- especially if two different size conductors are used. Conditions can result in the breaker tripping because of the loose connection [current exceeding the rating of the breaker]. Conditions can result in over heating and possible fire. Strongly recommend conditions are investigated further corrected as required by licensed electrical contractor. White neutral wires connected to circuit breakers should be black or red taped to designate they are hot, recommend further investigation and correction by licensed electrical contractor. Breaker(s) double tapped inside panel box (more than one electrical conductor attached). This condition may cause breaker tripping (overload, possible overheating and potential electrical fire. Recommend evaluation by licensed electrical contractor. This is typically easily corrected by a licensed electrical contractor. Page 36 of 49

1. Location Materials: Located in the laundry room. 2. Electrical Electrical 2 125 AMP service, #2 Copper service entrance wires. Federal Pacific service panel present. Federal Pacific panels have a history of circuit breakers not tripping in overload conditions and are a potential fire hazard. Recommend upgrading panel to a more reliable panel. 3. Wiring Type Breaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiring is copper. White neutral wires connected to circuit breakers should be black or red taped to designate they are hot, recommend further investigation and correction by licensed electrical contractor. Breaker(s) double tapped inside panel box (more than one electrical conductor attached). This condition may cause breaker tripping (overload, possible overheating and potential electrical fire. Recommend evaluation by licensed electrical contractor. This is typically easily corrected by a licensed electrical contractor. Page 37 of 49

Breaker(s) double tapped inside panel box (more than one electrical conductor attached). This condition may cause breaker tripping (overload, possible overheating and potential electrical fire. Recommend evaluation by licensed electrical contractor. This is typically easily corrected by a licensed electrical contractor. Neutral double tap Page 38 of 49

1. Foundation Foundation/Crawlspaces 1 Continuous concrete foundation visible portion appeared in good condition overall. Basement and concrete slab foundation. 2. Drainage Crawlspace area was dry, there were no visible indications of standing water presently 3. Framing Visible framing appeared in good condition overall. Cut floor joist under shower/tub, recommend conditions are repaired. There is a whitish and or darkened coloration that possibly could be a fungal/mold growth. Conditions are generally a result of excessive moisture at some point or inadequate ventilation. Testing may include surface sampling and air quality testing. Treating/remediation and correction moisture conditions will help prevent future occurrences. Recommend testing be performed. Earth to wood contact at framing can result in decay, recommend further investigation Page 39 of 49

4. Ventilation Inadequate ventilation. Normally there should be 1 square foot of venting for each 150 square feet of crawlspace surface area placed so that cross ventilation is achieved. Inadequate ventilation is a conducive condition for wood decay and mold growth, recommend conditions are corrected 5. Vapor Barrier Vapor barrier was mostly in place. Missing incomplete/vapor barrier, recommend 6 mil black plastic vapor barrier is installed with minimum 12 inch lap. This is a conducive condition for wood decay and mold growth 6. Insulation Condition No insulation present. Newer requirements are R30 insulation content. Page 40 of 49

7. Rodent/Pests Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also cause damage to insulation. Recommend conditions are investigated further by licensed Pest Control Company. Droppings present. Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also cause damage to insulation. Recommend conditions are investigated further by licensed Pest Control Company. Droppings present. Carcasses present. Page 41 of 49

1. Shutoff Locations Shutoffs 2 Water heater water line shutoff is located above the water heater. Page 42 of 49

1. Appliances/Equipment Equipment/Appliances: Equipment 2 Disposal 2 Dishwasher 2 Stove 2 Refrigerator Page 43 of 49

2 Washer 2 Dryer Page 44 of 49

Glossary Glossary Term Double Tap Expansion Tank GFCI TPR Valve Definition A double tap occurs when two conductors are connected under one screw inside a panelboard. Most circuit breakers do not support double tapping, although some manufacturers, such as like Cutler Hammer, make hardware specially designed for this purpose. Double tapping is a defect when it is used on incompatible devices. If the conductors come loose, they cause overheating and electrical arcing, and the risk of fire is also present. A double tap can be accommodated by installing a new circuit board compatible with double tapping. It is also possible to add another circuit breaker or install a tandem breaker to the existing breaker box. An expansion tank or expansion vessel is a small tank used to protect closed (not open to atmospheric pressure) water heating systems and domestic hot water systems from excessive pressure. The tank is partially filled with air, whose compressibility cushions shock caused by water hammer and absorbs excess water pressure caused by thermal expansion. A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system. The thermostat in a water heater shuts off the heating source when the set temperature is reached. If the thermostat fails, the water heater could have a continuous rise in temperature and pressure (from expansion of the water). The temperature and pressure could continue to rise until the pressure exceeds the pressure capacity of the tank (300 psi). If this should happen, the super-heated water would boil and expand with explosive force, and the tank would burst. The super-heated water turns to steam and turns the water heater into an unguided missile. To prevent these catastrophic failures, water heaters are required to be protected for both excess temperature and pressure. Usually, the means of protection is a combination temperature- and pressurerelief valve (variously abbreviated as T&P, TPV, TPR, etc.). Most of these devices are set to operate at a water temperature above 200 F and/or a pressure above 150 psi. Do not attempt to test the TPR valve yourself! Most water heating systems should be serviced once a year as a part of an annual preventive maintenance inspection by a professional heating and cooling contractor. From Plumbing: Water Heater TPR Valves Page 45 of 49

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expense to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all pages of the report as the summary alone does not explain all of the issues. All repairs should be done by a licensed & bonded tradesman or qualified professional. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Exterior Areas Page 3 Item: 1 Siding Condition Decay to band at steps northeast, east side. Crawlspace is behind this area. Recommend extent of damage is investigated further and repaired Page 4 Item: 5 Door/Window Decay occurring at threshold north side. Recommend extent of damage is investigated further and repaired Page 4 Item: 7 Electrical No power to outlet, recommend further investigation and correction. Box missing cover Exterior Storage Room Page 7 Item: 1 Storage Room Decay occurring, structure not fully accessible, bees were in this area Porches Page 8 Item: 1 Porch Guardrail balusters/spindles are spaced further than the maximum 4 inches, this requirement is to prevent small children from fitting through guardrail. Guardrail should be installed at a height of no less than 36" to 42". Recommend conditions are corrected as a safety precaution. Guardrails lower than 36 inches encourage people to set on the guardrail Exterior Stairs Page 9 Item: 1 Stair Steps were not uniform height, normally there should be no more that a 3/8th inch variance between riser heights. Recommend using caution. Roof Page 10 Item: 1 Roof Condition Recommend following conditions are investigated further by licensed roofing contractor and conditions corrected as required. Granular Loss At least 2 layers of shingles present Page 11 Item: 2 Flashing Siding butted against shingles, flashing not visible Attic 1 Page 12 Item: 2 Framing There is a whitish and or darkened coloration that possibly could be a fungal/mold growth. Conditions are generally a result of excessive moisture at some point or inadequate ventilation. Treating/remediation and correction moisture conditions will help prevent future occurrences. Testing would need to be performed to determine the presence or absence of Mold. Testing may include surface sampling and air quality testing. Page 46 of 49

Page 13 Item: 3 Ventilation Attic appeared inadequately vented. Normally vents should be placed equally at high and low areas so that cross ventilation is acheived. Recommend conditions are investigated further by licensed roofing contract and repair as necessary to ensure proper ventilation. Adding additional ventilation will help avoid premature aging of roof and help to maintain proper humidity and temperature control that could otherwise result in mold/fungus or wood decay. No eaves vents installed, recommend conditions are corrected. Page 13 Item: 4 Fan/Duct Not All Bathroom fans exhaust completely to the exterior. Typically piping should actually connect to exterior vent, recommend correction. This condition can result in mold/fungal growth. Page 14 Item: 5 Electrical Insulation has been installed over knob and tube wiring at various locations. This is a fire "Safety Concern". Strongly recommend conditions are investigated further by licensed electrical contractor prior to closing to ensure safety. Electrical tape on 1 wire north side Page 14 Item: 7 Rodent/Pests Droppings present. Indications of Rodent activity. Some rodent droppings can carry disease, recommend conditions are investigated further by licensed Pest Control Company. Kitchen Page 19 Item: 7 Electrical GFCI outlets have been required for Kitchens (since 1987) No GFCI protection present,, strongly recommend GFCI outlets are installed as a safety precaution. Improper electrical wiring under the sink, recommend correction by licensed electrical contractor Outlet and or Switch cover plates missing, recommend correction as a safety precaution. Hallway Page 21 Item: 2 Electrical No power to the outlet, Recommend further investigation by licensed electrician Stairs Leading to 2nd Floor Page 24 Item: 1 Stair Guardrail balusters are spaced further than newer required 4 inches. 4 inch requirement is so small children cannot fit through the guardrail. Steps were not uniform height, normally there should be no more that a 3/8th inch variance between riser heights. Recommend using caution. Hall Bathroom1 Page 25 Item: 2 Electrical GFCI did not trip with tester GFCI trip test, strongly recommend conditions are investigated further and corrected by licensed electrical contractor as a safety precaution. Page 26 Item: 7 Sinks Drain is open at the top, strongly recommend installing mechanical vent is installed to prevent sewer gas from entering in the living area Utility Room Page 47 of 49

Page 29 Item: 1 Utility Room North wall is a wood retaining wall that borders crawlspace. Wood may not be treated and decay could result Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also cause damage to insulation. Recommend conditions are investigated further by licensed Pest Control Company. Page 29 Item: 2 Electrical Outlet cover plates missing, recommend cover plates are installed. Plumbing/Water Heater1 Page 30 Item: 3 Age Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring or replacement. Page 31 Item: 4 Condition Seismic straps are not in place/ improperly installed. Normally there should be seismic straps installed at the upper and lower one thirds of the tank. Expansion tank is not in place. This is a hazardous condition on closed water systems. Recommend conditions are investigated further and corrected as required by licensed plumbing contractor. Plumbing/Water Heater 2 Page 32 Item: 2 Age Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring or replacement. Page 32 Item: 3 Condition Seismic straps are not in place/ improperly installed. Normally there should be seismic straps installed at the upper and lower one thirds of the tank. Expansion tank is not in place. This is a hazardous condition on closed water systems. Recommend conditions are investigated further and corrected as required by licensed plumbing contractor. Plumbing/Water Heater 3 Page 34 Item: 2 Age Water heater in excess of 12 years and has exceeded useful life span, recommend monitoring or replacement. Page 34 Item: 3 Condition Seismic straps are not in place/ improperly installed. Normally there should be seismic straps installed at the upper and lower one thirds of the tank. Expansion tank is not in place. This is a hazardous condition on closed water systems. Recommend conditions are investigated further and corrected as required by licensed plumbing contractor. Electrical 1 Page 36 Item: 4 Wiring Type Breaker(s) double tapped inside panel box (more than one electrical conductor attached). This condition may cause breaker tripping (overload, possible overheating and potential electrical fire. Recommend evaluation by licensed electrical contractor. This is typically easily corrected by a licensed electrical contractor. Electrical 2 Page 37 Item: 2 Electrical Federal Pacific service panel present. Federal Pacific panels have a history of circuit breakers not tripping in overload conditions and are a potential fire hazard. Recommend upgrading panel to a more reliable panel. Page 48 of 49

Page 38 Item: 3 Wiring Type Breaker(s) double tapped inside panel box (more than one electrical conductor attached). This condition may cause breaker tripping (overload, possible overheating and potential electrical fire. Recommend evaluation by licensed electrical contractor. This is typically easily corrected by a licensed electrical contractor. Foundation/Crawlspaces 1 Page 39 Item: 3 Framing Cut floor joist under shower/tub, recommend conditions are repaired. There is a whitish and or darkened coloration that possibly could be a fungal/mold growth. Conditions are generally a result of excessive moisture at some point or inadequate ventilation. Testing may include surface sampling and air quality testing. Treating/remediation and correction moisture conditions will help prevent future occurrences. Recommend testing be performed. Earth to wood contact at framing can result in decay, recommend further investigation Page 41 Item: 7 Rodent/Pests Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also cause damage to insulation. Recommend conditions are investigated further by licensed Pest Control Company. Droppings present. Indications of Rodent activity. Some rodent droppings can carry disease. rodents can also cause damage to insulation. Recommend conditions are investigated further by licensed Pest Control Company. Droppings present. Carcasses present. Page 49 of 49