PORTASCANNER PORTASCANNER TM ISO TECHNICAL SPECIFICATIONS COLTRACO. for Door Fan & Room Integrity Testing. Ult rasonics since 1987

Similar documents
PORTALEVEL MAX TECHNICAL SPECIFICATIONS

PORTALEVEL MAX Coltraco Limited, 46 Mount Street, Mayfair, London, W1K 2SA, United Kingdom

THE SAFETY GUIDE 2018 WORKING TOWARDS A SAFER ALUMINIUM INDUSTRY IN ASSOCIATION WITH

Ultrasonics Now & the Future

NATO Stock Number

User Manual for ULTRASCAN High Pressure Leak and Corona Discharge Detector

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

CONSTANT MONITORING OF GASEOUS SYSTEMS

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

SERIES. Infinity begins here

CLARITY II TURBIDIMETER

THE WORLD LEADER. in special hazard fire suppression solutions

LORAIN CIP 4890/48120 DC Power System

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

PRODUCT GUIDE. Fire Alarm & Life Safety Test & Maintenance Products

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

Ci200RR-THX. Architectural Speaker. Product Overview. Key Features. Architect and Engineer Specifications

Public Address Project Combisound System

i.net Engineered system solutions for

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

SF 228T TWO-WAY SOUNDFIELD CEILING TILE SPEAKERS WITH 8" WOOFER AND 70/100 V TRANSFORMER SPEAKERS

October Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance

EUROLIVE B1200D-PRO. larger systems!

ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION STEAM TRAP INSPECTION VALVE INSPECTION TIGHTNESS TESTING DETECTION OF PARTIAL DISCHARGES

MicroRay IR-100 NEW. Inspection MicroRay IR-100

SPEAKERS OWNER S GUIDE C205 C336 CC225

The New Device Class for Preventive Maintenance

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO

HTS101 XP OWNER S MANUAL

Cold chain monitoring technologies. Facility monitoring

ULTRASCHALLPRÜFGERÄT ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION

TABLE OF CONTENTS WHY KLIPSCH? KI SERIES TRACTRIX HORN SUBWOOFERS SPECIFICATIONS

KAPPA. BOX CONTENTS (1) 100.9w or 120.9w subwoofer (1) Foam mounting gasket (1) 3mm hex wrench (1) Owner s manual (1) Technical data sheet

Lutron GS-5800 ULTRASONIC GAS LEAKAGE DETECTOR

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Meeting Shadow. monitoraudio.com

RM SERIES LOUDSPEAKERS

USER MANUAL. Dolev 5 2-Way, Bi-Amplified Studio- Grade Speaker MODEL: P/N: Rev 1

SI 3C LP. 4" Low Profile Back Can. Speakers. n 3" (7.6 cm) full-range driver with a tuned port

FF 120T FF 220T EXTRON EXCLUSIVE PATENT PENDING FLAT FIELD SPEAKER WITH TRANSFORMER SPEAKERS. See How it Works WHITE PAPER

CVS 4 (EN 54) # # Exceptional Sound and Reliability

Open-area Smoke Imaging Detector. Engineering Specification

LORAIN CSP DC Power System

Trimless In-Ceiling & In-Wall

Figure 1. Figure 2. See notes 1 and 2 below.

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

FUNCTIONAL SAFETY MANUAL

FIRE & SAFETY SPRING 2016 EDITION

Ultra-Thin Flexible Heaters

Immersive HD Series 2017 Catalog

Coaxial Speaker System OWNER S MANUAL

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

TRUTH B1030A. active 2-way reference studio monitors are perfect for near-field monitoring applications from small mixing environments to multichannel

Cornered Ci2. Description FEATURES. 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection

DIGITAL CENTRALIZED Section NANOMASKIT

MMT. Moisture Management Tester

Architectural and Engineering Specification for a. Flash / Flare

Component Speaker System OWNER'S MANUAL

HART XL High Sensitivity Smoke Detection

recording BORN WITH 60 YEARS OF EXPERIENCE BRINGING OUR PROFESSIONAL AUDIO ATTITUDE TO THE STUDIO

Cartridge Heater Solutions

STUDIO L SERIES L810, L820, L830, L880, L890, LC1, LC2 OWNER S GUIDE

HART XL High Sensitivity Smoke Detection

U L T R A S O N I C G A S L E A K D E T E C T O R

Revel. M10 Owner s Manual

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Evacuate everyone Sonos Pulse & Nexus Pulse

MicrOTDR. Optical Fault Locator. User Manual

Product Training Module: Digital Pressure Sensors with CANopen Model DPS

200-4,000 Hz frequency /2" round, 15 /16" deep, 60-8KHz frequency

TECHNICAL DATA SHEET. FreeSpace DS 100F. Loudspeaker. Product Overview. Product Information. Key Features. Applications

AN10943 Decoding DTMF tones using M3 DSP library FFT function

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

Portable Holiday Detectors

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

SONOCHEK The ultrasonic testing device

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

TECHNICAL DATA SHEET. FreeSpace DS 16F 1 OF 8. Loudspeaker. Product Overview. Product Information. Key Features. Applications

MASK4(T) & MASK6(T) Instruction manual

SF 26CT 6.5" TWO-WAY CEILING SPEAKERS WITH 8" COMPOSITE BACK CAN AND 70/100 V TRANSFORMER SPEAKERS

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

Instruments Designed for POF & Fibre Optic Cable Testing

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

CMS CMS. Template cutout size: 187mm CEILING MONITOR SYSTEMS INSTALLATION MANUAL

INSPECTOR I SKILLS ADMINISTRATION

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.

Flexible Heaters W A T L O W. Temperature Sensors and Controllers SERIES EHG

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Solutions. Detection. 3M Personal Safety Division 3M Detection Solutions Products. Pocket Catalog for Safety Professionals

New Sensing products of Meggitt Group. Moscow - October the 23 rd

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

JBL Studio 1 series loudspeakers

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Bernstein product overview

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

DSW SERIES SUBWOOFERS

Premium Cabinet Loudspeakers. Installation manual

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

Transcription:

PORTASCANNER PORTASCANNER TM ISO 14520 for Door Fan & Room Integrity Testing TECHNICAL SPECIFICATIONS COLTRACO Ult rasonics since 1987 +44 207 629 8475 info@coltraco.co.uk www.coltraco.com Coltraco Limited, 46 Mount Street, Mayfair, London, W1K 2SA, United Kingdom

CONTENTS We welcome you to enter into our mission to create accurate, reliable and easy to use instrumentation, which enhance our customers' safety management. The issue is not just about compliance with the regulations; it is about the safe ship offshore and the safe site onshore. TM TM 03 04 05 06 07 08 09 10 INTRODUCING THE PORTASCANNER ISO 14520 CORE BENEFITS & DOOR FAN TESTING REGULATIONS ADVANTAGES APPLICATIONS & WHY BUY FROM COLTRACO? HOW PORTASCANNER TM WORKS TECHNICAL SPECFICATIONS KIT CONTENTS AFTER SALES This helps our customers to ensure lower risk, higher protection and business continuity. Safety for safety's sake.

INTRODUCING THE Portascanner TM ISO 14520 TYPE: Portable ultrasonic gas-/weather-/water-tight integrity tester FUNCTION: To identify precise leak areas, paired with 'Door Fan Testing' as part of recommended NFPA 2001 and ISO 14520 standard before installing a Clean Agent Fire System PART NUMBER: 509004-0311 NSN: 6625-99-257-8336 IMPA: 652778 THREE CORE BENEFITS 1. World-Class 2. Quick & 3. Non Destructive Accuracy Easy to use & Clean The most accurate unit of its type locating a leak site via visual and audible readings and identifying its extent with a definitive numerical result. Can test leaks as small as 0.06mm. Compared to the rival puffer test technology which is a purely visual inspection. It is a simple system, that is both easy to learn and operate. Testing can be completed quickly by one person and can also be done without disrupting the building occupants, unlike smoke puffer tests which involve evacuating a building or room. The Portascanner is a completely clean and damage free technology, which can be used in the sensitive environments clean agent systems operate in. Complying with Regulations for Clean Agent Fire Suppression Systems CURRENT SITUATION: Before installing Clean Agent fire suppression systems the integrity of the building structure commonly undergoes Door Fan Testingʼ. This test determines the Peak Pressure and Agent Hold Time necessary for ensuring the effectiveness of these fire suppression systems. As required by NFPA 2001 and ISO 14520 standards to calculate the overall leakage of a room. LIMITATIONS: Locating exact leak sites is currently done by a puffer test with smoke. However, such current methods do not provide precise, accurate results on leak location or size. SOLUTION: Today, the industry can benefit from using the Portascanner Integrity Test Indicator alongside the Door Fan Testing for a complete and comprehensive regulatory room test. Ideal for precise leak detection, Portascanner is an exceptionally accurate (to 0.06mm) and fast method. It is the first of its kind, intuitive to use, non-invasive, and consequently, is of immediate use to the Fire Industry. 03 04

ADVANTAGES APPLICATIONS Increases Safety- The method allows the user unparalleled leak detection. This leads to the user having superior control of the agent hold time and peak pressure, effectively guaranteeing the identification and extent of leak sites. Highly Accurate - Leakages as small as 0.06mm ± 0.02 mm can be detected and sealed. Significant leakage sites could go undetected using the much less accurate smoke puffer test. Portable - The complete kit is lightweight and hand-held, weighing 419 grams. Ease of Training - life -time support & training, DVD & Online Training Videos. No Training Cost - free-of-charge training online, via telephone and email. Clean Agent Fire Suppression Systems operate over a wide range of industries including: Computer rooms Telecommunication centers Records and data archives Testing / imaging equipment Reference material Chemical laboratories Clean rooms Control rooms Flammable liquid storage Offshore drilling rigs Robotic equipment Textile manufacturing Electric utility facilities Media storage Military vehicles Art, artifacts and historical collections Simple - Highly intuitive operation, easy to pick up to new users. Convenient - quick, easy and non destructive testing means that inspection can be completed with out disrupting the building occupants or damaging the inspection surfaces unlike rival methods. Approved- full Classification Society Approval with RINA & ABS as of July 2016. Dual-Purpose- Use as pre-surveying inspection tool, prior to bringing in full door fan test equipment WHY BUY FROM COLTRACO? STORY OF COLTRACO Since 1987 Coltraco Ultrasonics have been designing and manufacturing ultrasonic instrumentation for safety and servicing. OUR COMMITMENT TO SCIENCE We are committed to designing and manufacturing the most mathematically accurate products and systems globally, supported by the highest standards of technical support and customer care. OUR COMMITMENT TO SAFETY We are dedicated to being a Safeship and Safesite company, encouraging safety for safetyʼs sake. QUALITY Our Portascanner is carefully hand built and undergoes rigorous quality testing to ensure it meets the high standards expected by our customers, and to provide them with long-term reliability. 05 06

OPERATION Figure 1. Watertight Compartment Portascanner Generator Cable Transit Area The Portascanner TM Watertight has two main components a generator and receiver. The ultrasound generator emits a specific frequency of ultrasound (40,000 Hz). It is magnetic so can be attached onto a wide range of surfaces within sealed areas. The receiver then picks up the signal and converts it into a result indicating W/T integrity. RECEIVER The receiver is tuned to detect a specific frequency of ultrasound. The receiver comes with a sensor rod which allows a user to scan the entirety of a seal at close range. The receiver has both a visual and audio output. The visual output is shown on the LCD screen of the receiving unit. It is read mathematically and in decibels. There is a numerical representation, which can be changed into a decibel (db) reading, allowing seals to be tested to certification society standards. There is also a bar graph representation of the strength of the ultrasonic signal which is being detected. The audio signal is delivered via headphones which plug into the receiver unit (standard 3.5 mm jack). The receiver uses a process called heterodyning to change the ultrasound signal received into an audio signal which the user can hear. Figure 2. Non-compliant Compartment Portascanner Generator Closed Hatch Portascanner Receiver Reading - 0db - watertight Damaged Cable Transit Area GENERATOR Closed Hatch Portascanner Receiver The generator is placed on one side of a sealed compartment and turned on. The user stands on the other side of the compartment and uses the sensor rod to scan the seal. The receiver displays the strength of detected signal on the screen and the user can also hear it through the headphones. Leak sites will be apparent from an increased signal strength (see Figure 1). This will be shown by an increase in the readings on the screen display and in the volume of the audio signal. RESULTS The extent of the leak is indicated by the numerical readout. In terms of the numerical readout: 0-5 or 0 db indicates seal watertight integrity 6-100 or 1 db - 26 db indicates weather-tightness only 101+ or 27 db+ indicates weak seal compression High values indicate a full leak site 07 08

HOW PORTASCANNER WORKS TECHNICAL SPECIFICATIONS PORTASCANNER RECEIVER Extension Rod Connector LCD Visual Display PORTASCANNER RECEIVER Output 1 watt (maximum) audible signal (via calibrated headphones with visual 4 digit LCD display and graph) Size Weight Powered By 21.5cm x 8.5cm W x 3.5cm H 419 Grams 1 x 9V PP3 batteries with low battery indecation Volume UP and DOWN buttons Gain 0, 1,2,3 ON and OFF buttons MODE Battery life Enclosure 10 hours continuous use minimum Aluminium IP65 Waterproof The receiver uses ultrasonic technology to convert the 40KHz pulses sent by the generator into three easily comprehensible readings: audible, bar graph and numerical which enables the operator to understand if the seal is wholly watertight or to what extent a leak exists. PORTASCANNER GENERATOR PORTASCANNER GENERATOR Transducers Headphone Connection Output Mounting Arrangements Size Weight Powered by Battery life Enclosure 0.1 watt/100db unidirectional Permanent magnet 15cm L x 9cm W x 5cm H 431 Grams 2 x 9V PP3 batteries 10 hours minimum ABS material Low Battery Indication Power ON/OFF Button Battery Compartment The generator is an ultrasonic generator with three transducers. This will produce a strong signal in one direction i.e. directly from the transducer which fills the compartment being tested with ultrasound pulses, filling most compartments with 100m range. The generator is permanently fitted with a powerful magnet which allows it to be attached to the facility structure where required. A magnet cover is provided when the magnet is not in use. 07 08

KIT CONTENTS READY-TO-GO PACKAGE Operating Instructions, Calibration Certificate, Training DVD Portascanner TM Generator for multiple use and flexible applications Portascanner TM Receiver to relate results into audible and visual readings EXTENSION ROD 310mm L x 25 mm, Cable Length: 1m Supplied in 3 parts Alternative lengths can be supplied HEADPHONES Durable Carrying Case Headphone Set to minimize ambient noise and to hear audible readings Sensor Extension Rod to detect the integrity readings Type: Head-band electrodynamic headphones Frequency response: 20 18,000 Hz Impedance: 32 Ohms ± 5% Sensitivity: 105 db SPL at 1kHz Adaptor plug: 3.5 mm to 6.3 mm type www.coltraco.com COLTRACO Ult rasonics since 1987 Call: +44 207 629 8475 Email: sales@coltraco.co.uk 09 Intellectual Property: for full details please ask. *Coltraco, Coltraco North America, Portamarine, Portalevel, Permalevel, Portagauge, Portasonic, Portamonitor, Portasteele, Portascanner, Permascanner and others are trademarks or registered trademarks of Coltraco Limited, UK. DuPont, FM-200, FE-25, FE-13, and FE-241 are trade-marks or registered trademarks of E.I. du Pont de Nemours and Company and its affiliates. Novec 1230 is a trademark owned by 3M.