CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

Reaction to fire classification report No C-rev.1

Reaction to fire classification report No C

Classification report

Centrum stavebního inženýrství a.s.

Test Report: ICL/CR15/11/087

Additional reaction to fire classification report No H

Additional Reaction to Fire Classification Report

TFI Report Classification

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Form: KSD-100:10 Page 1 of 3

Centrum stavebního inženýrství a.s.

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

CLASSIFICATION REPORT

Classification Report

New European Fire Testing Classification for Construction Products

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

TFI Report Classification

DELTA Classification Report

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Analysis Report

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Test Report: ICL/H18/9039 Rev 1

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Analysis Report

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BCTC CARPET TECHNICAL CENTRE

New European Cable Testing and Classification

Certification of Translation Accuracy Translation of Document from Dutch to English

BS EN ISO : 2010

Not all insulation is the same! from fire testing to real fires.

Information Data Sheet. Fire behavior of decorative high pressure laminates (HPL)

Harmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study

BS EN ISO : 2010

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

Report VNLF Test Report

BS EN ISO : 2010

FAÇADE FIRE TESTS Towards a new European standard method

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

IMO Resolution MSC 61(67): Annex 1: Part 2

FUNDERMAX GMBH FIRE TEST REPORT

Development of a European approach to assess the fire performance of facades

Certifikat och provningsprotokoll för art och 4511

MEDIUM-DENSITY HOUSING # 7. Fire safety

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

TFI Report Reaction to fire test

Sýnishorn Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

CERTIFICATE OF APPROVAL No ME 5085

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Abrasion Resistance of Fluoropolymer and polyester Coatings

Analysis Report

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

Construction Products Regulation (CPR) and BS 6701

Vescom bv Sint-Jozefstraat AV Deurne Nederland

C-01 FIRE DECKS AND BULKHEADS

Loss Prevention Standard

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

ISO INTERNATIONAL STANDARD

BS 476: Part 6: 1989+A1:2009

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?


Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Facts about insulation and fires 29 October 2014

Report on Public Input June 2014 NFPA 101

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

This document is a preview generated by EVS

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Transcription:

P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification no. Sponsor Product name P.O. Box 70 5750 AB DEURNE THE NETHERLANDS AIRTEX magic FR duo wall covering Prepared by Efectis Nederland BV Notified body no. 1234 Author(s) C.C.M. Steinhage B.Sc. E.O. van der Laan M.Sc. Project number 2014516 Date of issue Number of pages 5 All rights reserved. No part of this publication may be reproduced and/or published without the previous written consent of Efectis Nederland. Submitting the report for inspection to parties who have a direct interest is permitted. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions of Efectis Nederland or the relevant agreement concluded between the contracting parties. 2015 Efectis Nederland BV Page 1 / 5

1. INTRODUCTION This classification report defines the classification assigned to AIRTEX magic FR duo wall covering in accordance with the procedures given in EN 13501-1:2007+A1:2009. 2. DETAILS OF CLASSIFIED PRODUCT 2.1 GENERAL The product, AIRTEX magic FR duo wall covering, is defined as a wall covering. 2.2 MANUFACTURER Mehler Texnologies GmbH Edelzeller Straße 44 36043 Fulda GERMANY 2.3 PRODUCT DESCRIPTION According to the sponsor the product is composed of: PVC coated PES Total mass: 350 g/m 2 See test reports for detailed specification of the product. 3. STANDARDS, REPORTS, RESULTS AND CRITERIA IN SUPPORT OF THIS 3.1 STANDARDS EN 15102:2007 Decorative wall coverings Roll and panel form products 3.2 REPORTS Name of Laboratories Name of sponsor Report ref. no. Test method Efectis Nederland BV THE NETHERLANDS Nederland 2015-Efectis-R000161 2015-Efectis-R000162 EN ISO 11925-2:2010 EN 13823:2014 This report consists of five pages and may only be used in its entirety. Page 2 / 5

3.3 TEST RESULTS Test method and test number EN ISO 11925-2 surface flame impingement Edge flame impingement EN 13823 Parameter No. tests Continuous parameter mean (m) Results Compliance with parameters Fs 150 mm 6 52 - Ignition of filter paper - Compliant Fs 150 mm 6 53 - Ignition of filter paper - Compliant FIGRA 0.2MJ [W/s] 101 - FIGRA 0.4MJ [W/s] 62 - THR 600s [MJ] 1.9 - LFS < edge - Compliant SMOGRA [m 2 /s 2 ] 3 107 - TSP 600s [m 2 ] 169 - Flaming debris - flaming 10 s - flaming > 10 s - Compliant Compliant 3.4 CRITERIA Classification criteria Class Test method(s) EN ISO 11925-2 Exposure = 30 s EN 13823 Additional classification Fire classification of construction products and building elements Excluding floorings and linear pipe thermal insulation products B C D F s 150 mm within 60 s Ignition of the paper in EN ISO 11925-2 results in a d2 classification. FIGRA 0.2 MJ 120 W/s LFS < edge of specimen THR 600s 7.5 MJ FIGRA 0.4 MJ 250 W/s LFS < edge of specimen THR 600s 15 MJ Smoke production s1 = SMOGRA 30 m 2 /s 2 and TSP 600s 50 m 2 ; s2 = SMOGRA 180 m 2 /s 2 and TSP 600s 200 m 2 ; s3 = not s1 or s2 Flaming Droplets/particles FIGRA 0.4 MJ 750 W/s d0 = no flaming droplets/ particles in EN 13823 within 600 s; d1 = no flaming droplets/ particles persisting longer than 10 s in EN 13823 within 600 s; d2 = not d0 or d1. This report consists of five pages and may only be used in its entirety. Page 3 / 5

4. AND FIELD OF APPLICATION 4.1 REFERENCE OF This classification has been carried out in accordance with clause 11 of EN 13501-1:2007+ A1:2009. 4.2 The product, AIRTEX magic FR duo wall covering, in relation to its reaction to fire behaviour is classified: B The additional classification in relation to smoke production is: s2 The additional classification in relation to flaming droplets / particles is: d0 Reaction to fire classification: B s2, d0 4.3 FIELD OF APPLICATION This classification is valid for the following product parameters: Surface density 350 g/m 2 This classification is valid for the following end use applications: Substrate Air gap Methods and means of fixing Joints Other aspects of end use conditions Non-combustible (class A1/A2 according to EN 13238:2010) Not applicable The wall covering was glued on the substrate according to the manufacturer s instructions, using the special adhesive Vescom 2000 Vertical joints only Wall covering 4.4 DURATION OF THE VALIDITY OF THIS REPORT There are no limitations in time on the validity of this report. This report consists of five pages and may only be used in its entirety. Page 4 / 5

5. LIMITATIONS This classification document does not represent type approval or certification of the product. C.C.M. Steinhage B.Sc. Project leader reaction to fire E.O. van der Laan M.Sc. Project leader reaction to fire This report consists of five pages and may only be used in its entirety. Page 5 / 5