The ultimate in air handling units: directly and indirectly fired

Similar documents
The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired

DF-IDF air handling units

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

... DF / IDF Gas fired combined heating and ventilation ...

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

RHC GAS FIRED HEATING COILS

UNITES TERMINALES ET MINI CTA FIDJI

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

Easdale International INFINITY

AIR HANDLING THERMAL CONDITIONS

CLIMACIAT AIR COMPACT

GHE Dehumidifiers for radiant cooling systems with heat recovery

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Centeral Station Air Handling Unit

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Double Skin Air Handling Units


USE sizes Horizontal and vertical versions Single or double flow arrangement (side by side or superimposed)

ALL PRODUCTS BROCHURE

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Triton Series High Efficiency Boiler

Now Available with PVC & Polypropylene Vent Configurations

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

VERSO Air Handling Units

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

AIR HANDLING UNITS MANDÍK

Direct Gas-Fired Make-Up Air Models DG and DGX

Air Handling Units. Geniox. Quick guide

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Vicot Air Conditioning Co., Ltd. CONTENT

RoofPak Applied Rooftop Systems

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

Commercial and Technical Data

Alfamini-Alfamax series

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Adsorption Dryers for Compressed Air

ULTI+ ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS

Heat pump and energy recovery systems

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

VERSO Air Handling Units

AIR HANDLING UNITS. Revision AG 16-07

Double Skin Air Handling Units

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Air Handling Units. Real HVACR people who understand your needs.

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

MECHANICAL SERVICES 101. Ian White

Technical Development Program

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

INDUSTRIAL / DOMESTIC WATER HEATERS

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Cooking specialists since 1972

Energy Recovery with Cooling and Heating Model ERCH

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

TF Series With SECOPAC LS

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

Air Handling Unit Future

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

AIRSTREAM. Plug & play heat recovery unit CLIMATE TECHNOLOGY FEELS BETTER, WORKS BETTER.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

Alfamini-Alfamax series

"NP" & "RG" AIRFLO. In-duct firing line burner

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

High Efficiency Commercial Gas Water Heaters

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

KELVIN Clim F497. Kelvin air conditioning

The ultimate fresh air solution.

Transcription:

KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake unit to a fully automatically-controlled air handling unit suitable for both indoor or outdoor use. There is a wide selection of heating systems, such as hot water batteries, gas or oil-fired modules, gas-fired make-up air systems or high performance gas-fired heating systems. Heat recovery and cooling are of course also possible. The air handling units can be for internal and external use. Mark air handling units are made from seawater-resistant aluminium panels with double-walled insulation as standard. This means lower weight and a longer lifespan. The Mark air handling unit is a highly developed, premium quality product that can be adjusted to the customer s requirements. Features Air displacements up to 69,500 m 3 /h Very economical to buy and use Integration of high-efficiency heating modules is possible Modular construction Easy to maintain Long life Flexible and variable Proven design Low weight 65

Dimensions Type of air handling unit Air displacement max. Dimensions (Width x Height) AHU 15 15 10 000 m3/h 975 x 975 AHU 15 20 14 150 m3/h 975 x 1280 AHU 20 20 19 150 m3/h 1280 x 1280 AHU 25 20 23 350 m3/h 1530 x 1280 AHU 30 20 29 150 m3/h 1890 x 1280 AHU 35 25 40 000 m3/h 2195 x 1530 AHU 35 35 60 000 m3/h 2195 x 2195 AHU 40 35 69 500 m3/h 2508 x 2195 Construction The air handling unit is of modular construction. The frame construction consists of profiled closed aluminium tube profiles. The individual cabinet modules can be installed in different ways, either in line, next to each other or on top of each other. The tube profiles are attached to each other using plastic angled profides to create a stable frame construction. Modular construction The individual parts of the air handling unit are quick and easy to install due to a well thought out system. In almost every case, the modules are supplied pre-assembled. The individual modules are fixed to each other so that they are airtight. The double-walled aluminium panels are mounted in the frame in an airtight manner. The centering section in the corner of the module ensures correct installation to the next module. Technical detail The access doors are fitted with adjustable, maintenance-free hinges (adjustable both in height and at the sides). The hinges, or panel clips if required, are mounted on the outside of the air handling unit. This prevents dirt from building up on the inside of the unit. The access doors of the air handling unit are fitted with lockable spring locks. The airtight closure of the doors against the housing is guaranteed by a special rubber profile. Air conditioning - 66

Sound and thermal insulation Noise reduction is an important point for consideration in the design of an air handling unit. For this reason, we have opted to use a doublewalled seawater-resistant aluminium panel with 30 mm rock wool insulation. This also results in excellent thermal insulation. Sound insulation of a dividing panel (ISO 717-1:1996) A lot of attention is paid to the smooth finishing on the inside of the unit, which makes it easy to clean. See table for sound insulation values. Sound insulation R Frequency Optimal fan power The heart of the air handling unit is the fan. Mark selects the most suitable fan for the application requested. Depending on the application, a fan with forward or backward curved blades or a free-running fan can be used. The fan and the motor are placed on a frame. The frame is set up on shock absorbers in the housing. Delta P air flow monitoring is possible. 67

Filter section To guarantee the right air quality, Mark offers a wide selection of filters. All necessary care is taken in the sealing of the filter frames and filters. Filters should be changed from the inside on the dirty side. The filter options are: Panel filter Bag filter short Bag filter long High temperature filter Special fi lters are available on request. Delta P filter monitoring is possible. B Heating systems A Mark air handling units can be equipped with various heat generators. C E D A Hot water battery B Gas-fi red condensing modulating high-efficiency air heater (> 106% efficiency) C Gas-fi red air heater module. D Direct gas- or oil-fired air heater. E Direct gas-fired make-up air burner, only applicable if all intake air is expelled in a controlled manner. Gas- and oil-fired air heaters No heat intermediary No heat loss during stoppages Large selection of heating capacities High-effi ciency Good temperature control The air handling unit can be supplied as plug & play. Air conditioning - 68

Hot water batteries Hot water batteries are designed as standard in copper-aluminium. The heat exchanger connections can be fitted internally or externally. Optional: Hot-dip galvanised Anti-corrosion coating Steam, thermal oil Frost protection thermostat Gas-fi red condensing pulsating air heater Efficiency >106% Closed design. Electronic ignition of the main burner. Control: modulating. Module suitable for installation in an air handling unit.. Type (upper value) Effi ciency at 100% load Effi ciency at min. load Burner turndown ratio 35 40 60 80 100 150 kw 34,9 40 60 80 103 150 % 95,7 94,8 94,2 94,3 94,2 94,8 % 107,3 107,3 107,4 106,3 106,3 107,0 +/- 4:1 5:1 5:1 4:1 4:1 4:1 m 3 /h 3760 3760 5640 7520 9400 14200 Air volume, max.* m 3 /h 7200 7200 8640 13680 16200 20880 * Larger air volumes using a bypass. Gas-fi red air heater module Closed design. Electronic ignition of the main burners by a pilot flame. Control: on/off, high/low or pulsing. Module suitable for installation in an air handling unit. TWIN type Nominal power 66 74 88 98 104 1) 104 kw 120,6 130,6 160,8 174,2 183,6 191,6 Air volume, max.* kw 134,0 145,2 178,6 193,6 204,0 213,0 m 3 /h 8000 8000 10000 10000 10000 10000 m 3 /h 11980 11980 15820 15820 15820 15820 * Larger air volumes using a by-pass. 1) Low NO x MONO type Nominal power 18 21 24 28 33 37 44 49 55 59 66 74 88 98 104 1) 104 kw 20,4 21,8 25,1 27,2 30,2 32,7 40,2 43,6 50,2 54,5 60,3 65,3 80,4 87,1 91,8 95,8 Air volume, max.* kw 22,7 24,2 27,9 30,2 33,5 36,3 44,7 48,4 55,8 60,5 67,0 72,6 89,3 96,8 102,0 106,5 m 3 /h 1960 1960 2440 2440 2970 2970 3960 3960 4940 4940 6000 6000 8000 8000 8000 8000 m 3 /h 3920 3920 4880 4880 5940 5940 7920 7920 9980 9980 11980 11980 15820 15820 15820 15820 * Larger air volumes using a by-pass. 1) Low NO x 69

Direct gas- or oil-fired air heater Burner Gas or oil Combustion chamber Stainless steel AISI 321 Chrome steel (AISI 409) for the sizes 335/400 Heat exchanger Stainless steel AISI 304 Type Nominal power Air volume, max.* 115 160 210 270 335 400 kw 130,9 182,2 239,2 307,6 381,6 455,4 kw 119,0 166,0 218,0 280,0 347,0 415,0 m 3 /h 6728 9361 12286 15796 19599 23402 m 3 /h 9611 13372 17551 22566 27998 33431 * Larger air volumes using a by-pass. CO 5 ppm NO 1 ppm NO2 1 ppm Number of grams (H 2 O) of water vapour per kg dry air. H2O gr/kg 2.5 2.0 1.5 1.0 0.5 ppm 2500 2000 1500 1000 500 CO2 0.938 gr/kg 740 ppm 1.646 gr/kg 1295 ppm 2,34 gr/kg 2.579 gr/kg DE MAX 1850 ppm 2035 ppm 5 10 15 20 25 30 35 40 45 50 55 K DT T as a function of the added CO 2 in ppm. Direct gas-fired make-up air burner Direct gas-fired air make-up air heaters are integrated into the air handling unit. This type of air heater is suitable only if the heated air is expelled in a controlled manner. Adjustment: modulating 20:1. 1 m 3 air 15 C = 1.20 kg. MONO type (upper value) Minimum load 55 110 165 220 275 330 385 440 495 550 660 770 kw 71 142 213 284 356 427 498 569 640 712 854 996 kw 64 128 192 256 320 384 448 512 576 640 768 896 kw 3,2 6,4 9,6 12,8 16,0 19,2 22,4 25,6 28,8 32,0 37,4 44,8 m 3 /h 3500 7020 10450 14130 17510 20800 24350 27820 31210 39730 41680 48700 Air volume, max. m 3 /h 9600 19200 28800 38400 48000 57600 67200 69500 69500 69500 69500 69500 Air conditioning - 70

Heat recovery Operating costs can be reduced and the environment protected by the use of heat recovery. Heat can be recovered using the following systems: Cross-flow plate heat exchanger Twin-coil heat exchanger Durable, no mechanical moving parts Reliable Simple installation Separate air flows Air fl ow via a by-pass is possible Very economical solution for heat recovery Effi ciency > 50% Fresh air and return air can be separated spatially Short installation length Suitable for installation in existing units Can also be used at higher temperatures, large selection of heat exchangers, number of tube rows and materials used (Cu/Al or galvanized steel) Effi ciency up to approx. 50% Heat wheel Low pressure drop Compact construction High heat-exchanging power Option to re-use latent heat Option to re-use available humidity Effi ciency between 60% and 90% can be selected 71

Mixing boxes The air handling unit can be equipped with a mixing box. This box is placed between the air extraction section and the air inlet section. The mixing box can be fitted with servomotorcontrolled dampers. Optional: Modulating - or open/closed control 24 V or 230 V. Cooling Direct cooling (air cooling), DX system Indirect cooling (water cooling), Chiller Adiabatic cooling, soft cool (optional) Indirect cooling Direct cooling Water is cooled in the cooling unit. Cold water is pumped into a cold water battery in the air handling unit. This will cool the air fl ow. The air flow is cooled directly, the humidifier is situated directly in the air flow that needs to be cooled. The cooling unit is installed separately from the air handling unit. Low investment costs Short installation length Low operating costs Good cooling efficiency Excellent air dehumidifi cation. Control sends the quantity of cold water through the air-cooled cold water battery. The cooling unit ensures the water temperature is constant. Highly adjustable Guaranteed cooling capacity. Low investment costs Short installation length Low operating costs No water-related problems (risk of freezing, glycol concentrate, corrosion). Good cooling efficiency Excellent air dehumidifi cation. Air conditioning - 72