MyFAST 16.0 Plus. Layout. Influent See note 4

Similar documents
MyFAST 8.0 Plus. Layout

MyFAST 6.0 BASIC. MyFAST 6.0. OPTIONAL: MyTEE Screen AMS & BMS. Biosolids Port by others

Lateral braces. Effluent Collection Pipe. by others. FAST Blowers. Airlines. 8" min. 20cm min. DETAIL A SCALE 1 : 25. Biosolids Port.

SaniTEE 1618 Screens. Biosolids Port by others BIO-MICROBICS 2014 DRAWN CTC 3/27/2009. MyFAST 4.0 BASIC Product Description & Layout

Control Panel. 183 MAX 72 MAX Height of Effluent Line. Maximum Water Level 124 MAX 49 MAX

Installation, Operation & Service Manual

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

TECHNICAL INSTRUCTIONS

OWNER S MANUAL ONSITE WASTEWATER TREATMENT SYSTEM MODEL NUMBER FTB 0.5 FTB 0.6 FTB 0.75 FTB 1.0 FTB 1.5

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Freestanding Acrylic Bathing Installation Instructions

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTRUCTION MANUAL HS-229G

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

TYPE POS Oil Shield Sump Pump

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Owner s Manual Hydro-X Vacuum Pac

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

FEATURES. Other Fed-Flush Arrangements

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

INSTALLATION AND OPERATION INSTRUCTIONS

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

Owners Instruction Manual

Xaact Spot. Xaact Hot Spot

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

User Guide. for the Beacon ProActTM 200 System

C&M REAR FEED Long-stroke Vertical Down-stroke Baler for Baling Multi-Materials

Duct Mount. Installation Instructions

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

DUST FREE CARBON Whole House Air Purifier

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

MH70230AS MH70236AS MH70248AS

Quest Power Electric Heat EHS 31 Pro

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

Owner s Manual Phoenix FireBird

RP, GP, XP Pro Series Installation Instructions

OWNER S MANUAL FOR USE WITH BIO-MICROBICS, INC. FAST WASTEWATER TREATMENT SYSTEMS

Detection System Model 3500 Series

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Multiple Boilers Electro TS Series Application EB-C-STG5

Controllers. Instruction Manual WARNING

DISCARD DECANTER IF: FUNNEL CONTENTS ARE HOT FAILURE TO COMPLY RISKS INJURY

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Dashley Outdoor Fire Table

HS Series Installation & Operating Instructions RadonAway

Instruction Manual WARNING

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Corrosion Dry Air Pak

MP-MBA-45T-1/60T-1 / 75T-1

INSTALLATION, OPERATION AND MAINTENANCE

Quest Power Electric Heat EHS 62 Pro

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

MODEL CDB8 INSTALLATION INSTRUCTIONS

Liebert CSU3000 Chiller

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Whirlpool Bathtub Model Number: MT618

sanctuary walk-in bathtubs PROUDLY BROUGHT TO YOU BY

walk-in bathtubs Thank you for choosing an AmeriGlide Sanctuary Walk In Tub, the world s highest quality walk-in bathtub.

SF180 Installation Instructions

Hardwired Model Shown. WarmlyYours Infinity Towel Warmer Installation & Operation Manual

Operation & Installation Guide

Ceiling Mount Air Purification System

Installation, Operation, and Maintenance Manual

Disinfectant Boost System DBS-125 Owner's Manual

ENCLOSURE AIR CONDITIONERS

Owner s. Coolerr. comply. To view

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Condensate Pump. Installation and Safety Instructions CP-16 CP

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

IN020 Rev F Page 1 of 8

AUTOMATIC SWINGING DOOR

INTERMEDIATE GUIDE BRACKET

HS Series Installation & Operating Instructions RadonAway

INFRARED RADIANT HEATERS

Quest Dry 105, 155, and 205 Dual

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017

Little Helios. Use Instructions Portable Barrel Burner. Toll Free: Phone: (+1)

COMBUSTION AIR SYSTEM Model: CAS-3

BUNN CWT-CS CWTF-CS BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

TECHNICAL MANUAL FLIGHT-TYPE DISHMACHINES Master/Clipper RC

Transcription:

NOTES: 1. The air supply line into the FST unit must be secured so as to prevent damage from pipe vibration. 2. The units are supplied with 3" semi-flexible airline connections with stainless steel MPT fittings. 3. Each blower will require 4" steel pipe to connect to the distributed airlift system. 4. Influent pipe shall be positioned to maximize preaeration. Influent shall come from a prescreening device selected based on the site conditions and characteristics of the influent. Influent See note 4 () 161 SaniTEE Screens Sludge Holding Overflow Sludge Collection Treatment Zone FST Blowers Collection Manifold LIXOR 4.0 XD Preaeration Zone Sludge Holding Zone 194.94 MyFST 16.0 Plus (32) 161 SaniTEE Screens Blowers and Blower Housings (2)Central Control Panel Biosolids collection piping (16) MyFST Segments (4)LIXOR 4.0 XD OPTIONL MyFST 16.0 BMS (Biosolids Management System) (2)Dual Sludge Pumps (2)Decant Pumps (2)LIXOR 4.0 (2) Jib Cranes THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE Sludge Pump ccess Sludge release to dewatering station SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 MyFST 16.0 Plus Layout REV. INI-02-M 1 OF 6

Influent Emergency overflow from Biosolids Storage Zone 16" SaniTEE Screen placement Biosolids Pump Pit 567 MIN 223 MIN 1152±25 453.60±10.00 Treatment Zone 0,000 Gallon MIN [303 m3 MIN] 79 MIN 994±13 31 MIN 391±5 194.95 194.95 Preaeration Zone 40,000 Gallon MIN [151m3 MIN] 76 MIN 30 MIN 122 MIN 4 MIN 1015±25 400±10 194.95 Biosolids release to Dewatering Station 91 36 91 MIN 36 MIN Sludge Holding Zone 16,00 Gallon MIN [63 m3 MIN] 20 5.42 MIN 23 MIN Freeboard 109 MIN 43 MIN 79 MIN 31 MIN 264 MIN 104 MIN 246 MIN 97 MIN 229 MX 90 MX Biosolids Water Level 264 MIN 246 MIN 104 MIN 97 MIN 20.32 6 PVC pipe opening 10 PVC Pipe MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 Tank Details REV. INI-01-Q 2 OF 6

10 PVC Components to attach to sludge pump pit provided by others 160±1.3 160±1.3 10 PVC TEE PVC TEE 155±1.3 61±.5 PVC Pipe 160±1 6 PVC Pipe 160±1 6 PVC Eow 6 PVC TEE Notes: 1. Biosolids Collection Supplied by Bio-Microbics 2. Secure Biosolids Collection grid every 36" [90 cm] 959 37 MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 Biosolid Collection REV. INI-01-I 3 OF 6

OPTIONL DIGEST ZONE See note 5. Jib crane Biosolids pump cable Decanting Pump See note 7 Electrical conduit to Bio-Microbics control panel provided by others Return to Treatment Zone 36 57 3" MIN air supply line utilizing galvanized or stainless steel piping from the blower housing to the treatment tank provided by others. 35 Concrete base provided by others 2 screws per side included See Note 1 29.72 MIN 12 MIN Minimum leg extension assembly See Note 2 & 3 See Note 5 Biosolids Pump See note 6 LIXOR 4.0 Notes: 1. Secure leg extension to the FST unit by placing two screws on each side of the leg extension (4 screws per foot are included). 2. To obtain the desired height of leg cut 4" [10] schd. 40 PVC pipe (not included). Minimum pipe length of 11 1/" [2.26]; For heights greater then 1" [45.7] use schd. 0 PVC pipe (not included). Consult factory for extending leg beyond 36"[91]. 3. nchor the leg extensions to the tank with non-corrosive hardware (not included) at the provided mounting points. 4. Tank, anchors, piping conduit, blower, housing pad and vents are provided by others. 5. LIXORs must be spaced in Biosolids Storage Zone for maximum mixing and aeration. Consult Bio-Microbics. 6. Sludge pump discharge piping must create at least 22' [6.7m] of TDH at 60 Hz and ' [2.4m] of TDH at 50 Hz. 7. Decant pump discharge piping must create at least 22' [6.7m] of TDH at 60 Hz and ' [2.4m] of TDH at 50 Hz. MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE SIZE DRWING NUMBER NME DTE DRWN CTC 3/27/2009 Details REV. INI-05-K 4 OF 6

Specifications for MyFST 16.0 Plus Wastewater Treatment System 1. GENERL The contractor shall furnish and install (1) MyFST 16.0 Plus treatment system as manufactured by Bio-Microbics, Inc. The treatment system shall be complete with all equipment as shown on the drawings and specified herein. The principal items of equipment shall include sixteen (16) FST interconnecting inserts with leg attachments, biosolids collection manifold, sixteen (16) SaniTEE screens, four (4)blower assemblies, and control panel. The MyFST 16.0 Plus unit shall be situated within a 160 000 gallon (606 m3) minimum tank, as shown on the plans. Settling tank(s) equaling ½ to 1 x daily flow must be used prior to MyFST. Tank(s) must conform to local, state, and all other applicable codes. The contractor shall provide coordination between the MyFST system and tank designer (supplier) with regard to fabrication of the tank, interconnecting piping, wiring, and similar items, installation of the MyFST unit and delivery to the job site. The optional Biosolids Management System shall include a biosolids wasting pump and biosolids decant pump with jib crane, two (2)LIXOR 4.0s with blower assemblies. ll tanks supplied by others. 2. OPERTING CONDITIONS The MyFST 16.0 PLUS treatment system shall be capable of treating the wastewater produced by typical family activities (bath, laundry, kitchen, etc.) ranging from four hundred (400)to two thousand four hundred (2 400) persons and not to exceed 160 000 US Gallons per day(606 m3/d). 3. MEDI The MyFST media shall be manufactured of rigid PVC, polyethylene, or polypropylene and it shall be supported by the polyethylene insert. The media shall be fixed in position and contain no moving or wearing parts and shall not corrode. The media shall be designed and installed to ensure that sloughed solids descend through the media to the bottom of the tank. 4. BIOSOLIDS COLLECTION MNIFOLD biosolids collection manifold will be provided which will be located below the MyFST 16.0. The biosolids collection manifold will consist of (6) six PVC lateral pipes that are equally spaced under the MyFST 16.0 with orifices specifically designed to remove biosolids from the MyFST zone. The 6 laterals will be connected into a PVC pipe header that will provide a single 10 inch discharge into the tank s Biosolids Pump Pit. 5. BLOWER The MyFST 16.0 PLUS unit shall come equipped with four blowers capable of delivering 1 600 to 2 00 CFM [2 720-4 760 m3/hr]. The blower assembly shall include an inlet filter with metal filter element. 6. REMOTE MOUNTED BLOWER The blowers shall be mounted outside the tank adjacent to the MyFST zone on a contractor supplied concrete base. The blower elevation must be higher than the water level in the tank and above any normal flood level. two-piece, rectangular housing shall be provided with tamper-proof screws. The 4 inch (100 mm) steel discharge air line and connections from the blower to the two (2) MyFST 4 inch (50 mm) air headers which shall be provided and installed by the contractor. 7. ELECTRICL/CENTRL CONTROL PNEL ll wiring must conform to code and provide the specified power to the blowers. Input power on 60 Hz electrical system is 230/415 VC, three phase, 372/193. mps. Input power on 50 Hz electrical systems 220/30VC, three phase, 353.4/216.6 mps. ll conduit and wiring shall be supplied by contractor. The control panel shall utilize a motor starter, overload, and be housed in a NEM 4 X enclosure. The control panel shall consist of a visual and audible alarm to indicate loss of power to the blower. manual silence switch is included.. OPTIONL BIOSOLIDS MNGEMENT SYSTEM OPTIONL BIOSOLIDS WSTING PUMP biosolids wasting pumps are located in the biosolids pump pit will be included with the optional biosolids management system. These pumps shall be capable of pumping 00 to 1200 gpm [3030 to 4540 Lpm] at 20 feet [6m] total dynamic head to the biosolids storage zone. The biosolids wasting pump will require a power supply from the panel to the pump. field adjustable event timer will control the duration of the wasting time and the frequency of wasting on an event timer. The contractor is responsible for supplying power to the pump. THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE NME DTE DRWN 3/27/2009 PF 5/25/2010 SIZE DRWING NUMBER MyFST 16.0 Plus Specifications 1 of 2 5 OF 6 REVISED 5/25/2010 REV.

Specifications for MyFST 16.0 Plus Wastewater Treatment System. OPTIONL BIOSOLIDS MNGEMENT SYSTEM CONTINUED. OPTIONL DECNT PUMP ND JIB CRNE decant pump will be included to pump the supernatant from the biosolids storage ZONE into the MyFST aeration zone. The submersible decant pump shall be capable of pumping 200 to 250 gpm[760-950 Lpm] at 20 feet [6m] of total dynamic head to the MyFST aeration zone. The contractor is responsible for supplying power to the pump. The decant pump will be controlled by a manual start/stop controller. Two (2) jib cranes will be provided for decant pump intake height adjustments to remove the supernatant from the biosolids storage zone. The jib crane will be designed to handle a lifting capacity of 500 Lbs. and a lifting range of 160 inches [305cm]. 9. GENERL INSTLLTION INSTRUCTIONS ll work must be done in accordance with local codes and regulations. Installation of the MyFST 16.0 Plus shall be done in accordance with the written instructions provided by the manufacturer. n operation and maintenance manual shall be furnished which will include a description of system installation, operation, and maintenance procedures. Each FST interconnecting insert weighs approximately 1300 pounds [590kg]. Four holes for lifting each FST interconnecting insert are supplied. Spreader bars are to be used in lifting the inserts. Place spreader bars between lifting holes. For details refer to the Installation Manual. 10. FLOW & PIPE SIZING The MyFST 16.0 Plus has eight () six (6) inch discharge ports. Each of the six (6) discharge ports are provided with a standard six (6) inch effluent gasket. The maximum free or unrestricted flow with the two (2) each six (6) inch effluent pipes is 250 U.S. GPM (945 LPM) with a 2.0 design safety factor. MyFST systems have been successfully designed, tested and certified receiving gravity, demand-based influent flow. When influent flow is controlled by pump or other means to help with highly variable flow conditions, then multiple dosing events should be used to maximize performance. 11. WRRNTY Bio-Microbics, Inc. warrants all new MyFST Plus models (MyFST Plus 4.0,.0, and 16.0) against defects in materials and workmanship for a period of one year after installation or eighteen (1 months) from the date of shipment whichever occurs first, subject to the following terms and conditions: During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated and maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge. Defective parts must be returned by owner to Bio-Microbics, Inc. s factory postage paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty and regular maintenance items such as filters or bus shall be borne by the owner. This warranty does not cover general system misuse, aerator components which have been damaged by flooding or any components that have been disassembled by unauthorized persons, improperly installed or damaged due to altered or improper wiring or overload protection. This warranty applies only to the treatment plant and does not include any of the structure wiring, plumbing, drainage, septic tank or disposal system. Bio-Microbics, Inc. is reserves the right to revise, change or modify the construction and/or design of the MyFST system, or any component part or parts thereof, without incurring any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, material, or workmanship, or delays in delivery, replacements or repairs. THIS WRRNTY IS IN LIEU OF LL OTHER WRRNTIES EXPRESS OR IMPLIED. BIO-MICROBICS SPECIFICLLY DISCLIMS NY IMPLIED WRRNTY OF MERCHNTBILITY OR FITNESS FOR PRTICULR PURPOSE. NO REPRESENTTIVE OR PERSON IS UTHORIZED TO GIVE NY OTHER WRRNTY OR TO SSUME FOR BIO-MICROBICS, INC., NY OTHER LIBILITY IN CONNECTION WITH THE SLE OF ITS PRODUCTS. Contact your local distributor for parts and service. MyFST 16.0 Plus THE INFORMTION CONTINED IN THIS DRWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. NY REPRODUCTION IN PRT OR S WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN ND INVENTION RIGHTS RE RESERVED. IN THE NME DTE DRWN 3/27/2009 PF 5/25/2010 SIZE DRWING NUMBER Specifications 2 of 2 REVISED 5/25/2010 REV. 6 OF 6