Power Locking Installation Manual

Similar documents
FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

Phoenix 2 Rev. A - Owner's Manual 0399

Model: M30. Owner s Operation Manual. For correct operation, please read this manual to familiarise yourself with the features.

G34 AU1B (External Ultrasonic Sensor) Version 3

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

MEGA WAY LCD 4-CHANNEL MOTORCYCLE ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 3100 OPERATE 1

e-ask electronic Access Security Keyless-entry

For silent arm / disarm use BUTTON 2.

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm

745i 3 OPERATION MANUAL TABLE OF CONTENTS

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

640 Series Advanced Remote Vehicle Security System

CA 120 Owners Manual of 10

AMX 68 Owner's Manual 12/29/97

Important information. Government Regulations and Safety information. Your Warranty. Replacement remote controls

What you get Welcome to the best generation of security with remote start. Your system contains everything you need.

SR-i500 INSTALLATION MANUAL AND USER S GUIDE. FM 2-Way Security System. Setting Clock Time. Setting Alarm Clock. FCC Notice

What you get Welcome to the best generation of security with remote start. Your system contains everything you need.

3121V O WNER S GUIDE & INSTALL GUIDE. The company behind Viper Auto Security Systems is Directed.

Remote Vehicle Control System. Security and Convenience System

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

NO ONE DARES COME CLOSE

NO ONE DARES COME CLOSE O WNER S GUIDE 7756V

REMOTE CONTROL CAR ALARM SYSTEM

Remote Vehicle Control System

NO ONE DARES COME CLOSE O WNER S GUIDE 7857V

Remote Vehicle Control System. Car Start, Security and Convenience System

-1- REMOTE CAR ALARM SYSTEM. Technical Help Line

Sentry 4 Zone Alarm Panel User Manual

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

380 SERIES REMOTE SIREN ETSA380R

Model 2504A USER MANUAL REMOTE CONTROL ENGINE STARTER. For all gas- and diesel-powered vehicles (FRANÇAIS AU VERSO)

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Vehicle Security System

9000P Wireless Alarm Owner s Manual

Remote Chexit Module (RCM) System. General Information

AVS A4 alarm Owner s manual

O WNER S GUIDE M O D E L

Model 700 ESP Owner's Guide

O WNER S GUIDE M O D E L

O WNER S GUIDE M O D E L

LeakSafe. solutions. WaterSwitch2. Installation Instructions

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Model AM1 Owner s Guide

Ethernet General Purpose

AVS S5 Alarm Anniversary Model

Control/Communicator Installation Manual

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INSTALLATION AND USE MANUAL

BRIDGE 4100 MANUALE UTENTE USER INSTRUCTIONS MANUEL POUR L UTILISATEUR MANUAL DE USO

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

Installation & Programming Guide

DE5300 Delayed Egress System. General Information

What you get Welcome to the best generation of security with remote start. Your system contains everything you need.

TSM/TSSM OVERVIEW 3.1

MODEL APS-15 REMOTE CONTROL AUTO SECURITY SYSTEM DU SYSTÈME DE SÉCURITÉ AUTO À COMMANDE À DISTANCE DE SEGURIDAD DE AUTOMÓVILES A CONTROL REMOTO

NO ONE DARES COME CLOSE

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

MOTORCYCLE SECURITY 866F ADVANCED MOTORCYCLE SECURITY All Rights Reserved Ver. 2.4, Apr. 11

General Purpose IO Technical Manual

GSM CAR ALARM SYSTEM USER S MANUAL

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

7590TK15 INSTALLATION AND USE MANUAL

Installation and ZONES: Operation Manual. Model: ON STI-34108

838 CAR ALARM SYSTEM USER S MANUAL

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

Kwêbeam GSM/Interface/Repeater Module

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

2006 directed electronics

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

limited lifetime consumer warranty

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

Operating instructions 2-channel code lock. Item No

888 TWO WAY CAR ALARM SYSTEM USER S MANUAL

Model 3901T / 3902T / 3903T

Solution 880 Operators Manual. Issue 1.00

Transponder reader TECHNICAL SHEET (White) (Magnesium)

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

RF2352A, HC2351AC (Discontinued), HC2352AC

WARNING Important Safety Information

M60 Series WITH BUILT-IN TURBO TIMER. OWNERS OPERATION MANUAL includes programming and wiring information

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM WS-500X CONTENTS REV: 0.2 ERP P/N: ERP 机型 :SS21W2R-AU-EDP09940A-V1

Installation Instructions

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

WM3000 WIRELESS MODULES

ZM1 User Manual JVA TECHNOLOGIES.

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

CC408. Quick Reference Guide Solution 880

hc3 OWNER S MANUAL OMHC3US2016/07E

400 SERIES CONSOLE SIREN ROTARY OR PUSH-BUTTON USER INTERFACE

WARNING Important Safety Information

/ /24 INSTALLATION AND USE MANUAL. Made in Italy AC 2710/UK Rev /12

Transcription:

Shop Manual V203 Please Copy Necessary Pages, and Store the Original Power Locking System PLRB-Pro Controller Flex Switch & Key Fobs Numeric Keyless Interface Power lock (Compartments) Power Locking Installation Manual

PAGE # PART # DESCRIPTION QTY COST WORKS WITH ALL OEM OR NEW WORK SYSTEMS OFFICE 512-301-0303 FAX 512-301-0320 support@poplocks.com

Flex Switch. "Where You Want It When you Need It." TM Pilot is in control of their powerlocking wireless FLEX SWITCH. Home alone or a "lone home" zone security is on the job. Where you want it, when you need it. Time for bed? The touch of a finger locks all outer compartments and entry doors. 3

T-25 Fob & Flex Switch I & II Optional Flex Switch I TM (RSI) Mounting Flex Switch (RS1) is done using the 2 Fasteners through mounting holes. Carefully select the area best suited for its placement. Confirmation Led Finger Pull Front With Battery Cover HDC.Inc. 63.35mm 2.500in. Designed with through holes for mounting on any flat surface. 31.65mm 1.250in. 2-4 X Min. 5/8 Long Wood / Metal Screw - + Fig. A Side View Flex Switch is coded using the same process as Key Fobs described in User Manual code learning section. 56.98mm 2.250in. Fig. B Flex Switch II TM (RS2) Front and Cover Side Front Cover Off Replacing the Flex Switch II battery the cover must be removed. Using only a fingernail or paper clip, depress the tab on the bottom of the flex switch. Cover will hinge at the top revealing the inside components. Replacement batteries are 12v part # GP23A, CN23A, El12 and Vr22 or similar class battery. Replacement battery must be installed as shown in Fig B. Its orientation is specific to +- polarities clearly marked. Replace cover and test. Depress to open Fig. A 2 1/3 inches 59.182 mm.5 inches 12.7 mm The battery mates to the contacts and cradles inside the bezel. Battery held in place only by cover and contacts. - + - + 1.5 inches 38.1 mm Fig. B T-25 Transmitter To replace the T-25 Key Fob battery (Fig D.), the shell of the transmitter must be removed. Pry between the depression around the shell and separate the fob into 2 pieces exposing the battery as shown in Fig. D. Replacement batteries are 12v part # GP23A, CN23A, EL12 and VR22 or similar class battery. Replacement battery must be installed as shown in Fig. D. Its orientation is specific to - + polarities clearly marked. Replace cover and test. Fig. C + - + - B A TTER Y Fig. D Front With Cover Off 4

PLRB-Pro Controller Programming Guide FEATURES CODE LEARNING (RS-1 & KEY FOB) a. ACC ON, press Valet Switch 10 times within 5 seconds. Siren will sound 3 times to indicate entering code learning. Then press any button on the remote control within 15 seconds and siren will chirp as confirmation. The chirp times will correspond to the key fobs learned. With the second key fob learned, siren will chirp twice, and so on. b. If a new remote control is to be programmed, all existing remote controls must be reprogrammed at the same time. Maximum of 10 remote controls can be programmed. c. Up to 12 transmitters can be coded and held in memory, with the 13 th transmitter, the siren will sound for two seconds while exiting programming mode. d. During programming mode, press valet switch once for 3 seconds and the siren will chirp 4 times to confirm that existing codes have been cleared. e. Time allowed between coding is 15 seconds, if time is over 15 seconds or ACC is off the system will exit programming mode automatically ARMING a. Using Key Fob Transmitter press button 1. b. Siren will sound once, unless chirp delete selected. c. Parking light will flash once. d. Doors will be locked at a 0.5 sec or 3.5 sec duration as selected. e. a. The doors lock outputs sequentially lock in order (Relay 1, 2, 3) f. b. LED will flash slowly. g. c. Disables Engine S tarter (if Starter Kill Relay connected). After 5 seconds, alarm is armed. Sensor triggered within this period will be bypassed. Please refer to SENSOR BYPASSED WARNING for details. h. d. RS Switch Lock button will arm Alarm Door Triggers but disable Shock & Ultra-sonic sensors. Disarming a. Press button 2 or press RS Switch UNLOCK button. B. Siren will sound 3 times and parking lights will flash 3 times. If siren sound 4 times and lights flash 4 times, it means the alarm has been triggered. If chirp delete selected, only parking lights will flash and no siren will sound. c. Doors will unlock at 0.5 seconds or 3.5 seconds as selected. d. Doors will sequentially and automatically unlock if "3C OFF" is selected. Relay unlocking order 1, 2, then 3. If "3C ON" is selected, pressing button 2 once will unlock only Relay 3, the external relay. Pressing button 2 again within 3 sec will unlock Relay 1, then Relay 2. The Step & Door Signal will follow after unlock output is complete. e. Enables engine (if Starter Kill Relay is connected). f. Dome light will be turned on for 30 sec or light off when ACC on. g. If alarm is in Passive Arming mode, LED will flash quickly. After 30 seconds alarm will be automatically re-armed. 5

PLRB-Pro Controller Programming Guide Emergency disarming -Override (default value is 5) a. In armed mode: If remote control fails or is lost, turn ACC ON. b. Press Valet Switch 5 times, siren will chirp 4 times. The alarm is then disarmed. This coding process must be finished within 8 seconds. c. The owner can reset the Transmitter codes. Please refer to code learning section a, b, c, d, e. d. "Smart Locking" Automatic Door Unlock ("3C OFF" Mode) With ACC OFF, the doors will automatically unlock in order, Relay 1,2, and 3. In "3C ON" mode, only the external unlock relay 3 will be activated. Relays 1 and 2 need to be functioned by pressing button 2 rapidly twice. "Smart Locking" Automatic Door Lock When ACC ON, after 16 seconds all doors will automatically lock in order (lock Relay 1, Relay 2, then Relay 3). Valet Mode a. When ACC ON, press and hold the Valet Switch for 3 seconds within 8 seconds. b. System will enter VALET mode and LED will be constantly ON as indication. c. In VALET mode, siren will chirp twice and parking lights will flash twice when doors lock. d. Disable valet mode: When ACC ON, press and hold the Valet Switch for 3 sec. Within 8 sec, LED will be OFF. Panic a. Press and hold button 1 and 2 on fob or press and hold lock button on RS Switch, the siren will sound and parking lights will flash for 30 seconds. b. Pressing button 1 or 2 will stop the panic. Vehicle Finder a. Alarm is armed. b. Press button 1: siren will sound once and parking lights will flash 10 times. If alarm chirp delete is selected, then parking lights will flash 10 times but without sound. c. Press button 2 to stop it. Auto Remarming (See function 3 & 4) When alarm is disarmed, if ACC is not ON and doors not open, after 30 sec., system will be automatically rearmed. Door-Opened Warning (See function 6) If one of the doors is opened when ignition is ON, the parking lights will flash 1-minute max. as warning to driver and other vehicles. Memory Function The alarm memory will record the last condition when the power is cut off. Sensor Triggered in Arming a. Shock Sensor: see above explanation. b. If an additional sensor (AUX input) triggered, siren will sound for 30 sec. & parking lights will flash for 30 sec. c. If door triggered, siren will sound for 30 seconds and parking lights will flash for 30 seconds for 3 cycles. d. If ACC is triggered, siren will sound and parking lights will flash. 6

PLRB-Pro Controller Programming Guide SENSOR BYPASS WARNING Pressing button 1 during the first 5 seconds, if any sensor is triggered, that sensor will be by -passed, and siren will chirp twice as indication. The by -passed sensor will be back and functioning after 2 seconds of no trigger activity. FUNCTION TABLES AND CLEARANCE OF THE SETUP VALUE PROCEDURES. a. Disarm the system. b. Turn ignition ON. c. Press Valet Switch 7 times within 10 sec. After 10 seconds, the siren will chirp once. d. Turn ignition OFF, then the LED flashes slowly. e. Press the Valet Switch the number of times as the function number you would like to change. Every press will have one siren chirp as confirmation. Turn ACC ON as confirmation of the function selected to change. One chirp means preset value, two chirps means variable value. One operation must be finished within 10 sec. Turn ACC OFF to repeat the above procedure. SELECTABLE FUNCTION PRESET VALUE ( 1 CHIRP) VARIABLE SET-UP (2 CHIRPS) 1. Lock/Unlock time 0.5s 3.5s 2. Ignition ON door/lock ON OFF 3. Passive ARMING OFF ON 4. Passive locking OFF ON 5. 3C ON/OFF ON OFF 6. Door-Open warning ON OFF 7. Delete shock sensor OFF ON 8. Arm/disarm chirp YES NO 10. Default YES LED CONDITIONS a. When armed, LED will flash slowly once a sec. b. When armed, if alarm is triggered, LED will flash quickly. c. LED will flash quickly when system starts Passive Arming count down. d. Valet mode: LED constantly ON. PARKING LIGHTS EMERGENCY FLASH In armed mode, parking lights will flash for 30 seconds for 3 cycles if alarm is triggered. SIREN EMERGENCY SOUND In armed mode, siren will sound for 30 seconds for 3 cycles if triggered. 3C ON /OFF If 3C OFF is selected, the sequence of unlock will be relay 1, relay 2, and relay 3. If 3C ON is selected, the sequence will be as followed: press Unlock button once and relay 3 will be activated. Then press unlock button again within 3 seconds and relay 1 and relay 2 will be activated sequentially. DOOR AND STEP SIGNAL OUTPUT: Will be a constantly negative output after Unlocked, disarmed and ACC off. 7

PLRB-Pro Controller Programming Guide Please Note: Pro Controllers are installed often with a reduced feature harness. To add other accessories it will be necessary to add a full feature harness Part # 14PH. Visit our web site:.poplocks.com regarding this or other accessories or how to manuals. ID. M3FL. PRO CONTROLLER poplocks.com Antenna ID. M3FL. PRO CONTROLLER poplocks.com Part # PLRB-Pro 12 Volt DC Zone Alarm Sequential Locking Code Learning Flex Switch Compatible. LED & Valet Wiring Show Is Not Necessary In Order. 30 A Not Essential For Basic Operation Ultrasonic Sensor See Detail US-1 Zone 2 Shock Sensor See Detail SS-1 Zone 2 Third (3C) Channel Relay See Detail 910-1 Siren Dome Pos.+ Output C3 Unlock Green/White C3 Lock Blue/White Pink Dome White Green Pos.+ Brown Neg. - Unlock Purple Neg. - Lock Purple / White Pos.+ Unlock Brown / White Pos.+ lock Yellow IGN On Orange Black/White Neg.- On Unlocked Door/ Step Output Gray Neg.- Trigger Input Blue Pos.+ Trigger Input Red Pos. + Green Unlock C2 Brown Unlock C1 White Lock C1 Blue lock C2 Black Ground - 10 A Zone 1 Zone 1 Relay 85 86 87a 30 } Main Power Input Grounding Sequential Locking Outpots Neg.- Neg.- Running Lamps Momentary Switches Neutral @ Rest Note: Activation Of Hard-wire Switches WILL NOT Activate Any Security Features. RS-1 Flex Switch Activates Zone 2 Only Fob Activates Zone 1&2 Neg.- Neg.- Starter Solenoid Cut Start Ignition Switch 8

PLRB-Pro Controller Schematic Note: KE1601 Used As A Power Lock Trigger Interfaced As Shown Will Only Unlock Outboard PL910 Relay. Lock Signal Will Lock All In Sequential Starting With Relay 3, 2 Last 1. See: Ke1601 Schematic 1 (White/Red) Unlock, To Green/White, Output 3C (White/Black) Lock, To Purple Neg. Lock Input Third (3C) Channel Output First To Lock 30 AMP 12 VOLT 30 AMP 12 VOLT Plug Plug (White/Red) Unlock, Neg250mA, (White/Black) Lock, Neg250mA, (Black) System Ground (Red) 12V DC Constant. PRO Controller Output Schematic 14 pin 6 Pin Ground Outboard Relay Part # PL910p. 5 Additional Compartments Or Independent 3rd Channel Output. Detail 910-1 30 A 12VDC Max. Provided Tee Tap 30 A 12VDC Max. ACT. 2 3 4 5 Second To Lock Left Baggage & Compartment 1 ACT. 2 3 2 3 4 5 1 Third To Lock Right Baggage & Compartment 9

New Work Power Lock Installation Adhesive base PL801 and other bases require that their surfaces be cleaned. It is recommended that #00 steal-wool or a scuffing pad be used, followed by a solvent such as Acetone / Lacquer Thinner. Carefully select the final placement. Once installed its removal will damage the base & adhesive making them not reusable. Attach Actuator To PL801 Base Remove Adhesive Covering Patent Pending Connect Nylon Rod Connector To Latch Connect Linkage To Actuator. Next Install Actuator. Cover Will Keep Actuator In Place 10

New Work Power Lock Installation Rear Side Of Door Shown With Cover Bolts Bolts The actuator is placed using PL801 adhesive base and prebent linkage. The base is mounted to the actuator with thru studs. The final placement of actuator and base is permanent. HIN G E HIN G E Bolts Bolts Rear Side Of Door 11