GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

Similar documents
Phase-Adaptive Power Module

ELVI Electronic Low-Voltage Interface

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

2800 Series Control Units

Stellar Panelboard Dimming Systems

Use this addendum with the LP Installer s Guide to install a. GRAFIK RP System

EcoSystem H-Series Ballasts Overview

EcoSystem H-Series 347 V~ Ballast Overview

EcoSystem H-Series Ballasts

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Grüv Flare Regressed. Recessed Linear LED

design guide for wireless l i g h t i n g c o n t r o l

Off-Grid CyboInverter Installation Guide. For CI-Mini-1200H Solar Mini-Inverter for Electric Water Heaters

DALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps. Approvals:

Application Note #106 Revision D June Emergency Lighting. Overview

Installation Guide for models:

PART GENERAL 1.01 SECTION INCLUDES

Installation Guide for models:

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

DRC12FR DRC12FR347. Dynalite. Install Guide


POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Series. Access Power Controllers. Installation Guide

Public Safety DAS Annunciator Panel

Grüv Flare Regressed. Recessed Linear LED

RMS/RPX Reader. User Manual

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Classix 6" 6" Round Adjustable C3M

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Product Bulletin for Decora Rocker Slide Controls

SECTION CENTRAL DIMMING CONTROLS

GRAFIK T Controls GRAFIK T

CHAPTER 20 SERVICE EQUIPMENT

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SECTION INTERIOR LIGHTING

Classix 6" 6" Round Adjustable C3

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

HomeWorks QS Architectural RF GRAFIK T Local Controls

HomeWorks QS Palladiom HVAC Solution

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Integrated PIR detectors

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

SERVICE BY QUALIFIED PERSONNEL ONLY

SECTION LOW VOLTAGE LIGHTING CONTROLS

Hornet HP. Square Glass Downlight

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

SAFETY INFORMATION AND WARNINGS

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

S5JB Quick Setup Guide. Refer to the instructions on the following pages for complete details on the steps outlined below.

ELP21LU3-LF-HLOL THREE CHANNEL

Altman Lighting Spectra Cyc UV 50 Specification

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

C-Bus Four Channel Analogue Output Unit Installation Instructions

Linea 1.5. Linear Direct Wall Wash LED

Installation Instructions

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Evoke Square Adjustable HP

Installation and Operation Manual Low Power (LP) DC Power System

ASCO Series 185 Power Transfer Switches

Application Note #603 Revision A June 2016 Lighting Control for Noise-Sensitive Applications

HIGH BAY APPLICATIONS

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Evoke Square Adjustable HP

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

Planning Elevator Relay Groups Programming Millenium for Windows Software

Catalog Number. Notes

SITESTAR CABINET DESCRIPTION

Hornet HP. Round Glass Downlight

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

Please Read. Dimming Panels. Contents

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Evoke Square Downlight

HARDwired Installation/ Owner s Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Abella Digital Fade Dimmer

DOOR MONITORING/DURESS SYSTEM

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

SPECIFICATION SUBMITTAL

SECTION (16140) - WIRING DEVICES

SYSTEM. field cuttable. lipleds 8200 Series

Spectron LSN (Life Safety Network) Suggested Specifications

Evoke Round Adjustable C3

/9308 External Battery Chargers Installation Instructions

Transcription:

DESCRIPTION Controls all Lutron 3-Wire Fluorescent Dimming Ballasts (Hi-Lume, ECO-0, and Compact SE). Provide power and dimming for up to 4 fluorescent circuits. Models available for: 0V: 8 to 4 circuits. 77V: 8 to 6 circuits. with main lugs. GPF 8-4 Panels work with: GRX-4000 Control Units GRAFIK 5000 and 6000 Systems GP Dimming Panels LP Dimming Panels XP SoftswitchTM Panels

SPECIFICATIONS Standards UL Listed. Complies with CSA or NOM (where appropriate). Power Input power: 0V and 77V. All voltages 50/60Hz, phase-to-neutral. Branch Circuit Breakers: UL-rated thermal magnetic. Protected by bypass jumpers. AIC/RCB ratings (other ratings available): - 0V 0,000-77V 4,000 Lightning strike protection: Meets ANSI/IEEE standard 6.4-980. Can withstand voltage surges of up to 6000V and current surges of up to 3000A. 0-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Sources/Load Types Operates all Lutron 3-wire Fluorescent Dimming Ballasts (Hi-Lume, ECO-0, and Compact SE) with a smooth continuous Square Law dimming curve. Internal: Prewired by Lutron. System communications: Low-voltage Class (PELV) wiring connects Dimming Panels to other components. Line (mains) voltage: Feed, load, and control circuit wiring only. No other Dimming Cards Panel current ratings are listed for continuous operation. RTISSTM filter circuit technology compensates for incoming line voltage variations: No visible flicker with +/-% change in RMS voltage/cycle and +/-% Hz change in frequency/second. Physical Design Enclosure: NEMA-Type, IP-0 protection; #6 U.S. Gauge Steel. Indoors only. Weight: 5-75 pounds (5-80kg). Mounting: Surface mount only. Allow space for ventilating. Environment/Heat Dissipation Patented, ribbed aluminum heat sink base cools Panel by convection. No fans. 3-04 F (0-40 C). Relative humidity less than 90% non-condensing. WHAT A MODEL NUMBER TELLS YOU Standard Prefix for GPF Dimming Panels Feed Type 4 for Branch Circuit Breaker Number of amps wiring or assembly required. G P F - 0 4 M L - 0 Number of Load Circuits Voltage 0 77 Panel Breaker ML for

GPF 8-4 MODELS (0V AND 77V) 0V Power WIRE SIZES NUMBER OF CIRCUITS GPF 8 MODELS AVAILABLE FOR... FEED TYPE PANEL FEED MAXIMUM FEED 60A BRANCH CIRCUIT BREAKER Feed PANEL FEED WIRE SIZES #4 AWG (.0mm ) to #/0 AWG (50mm ) GPF GPF 6 80A 5A Load Circuit Connect to Terminal Blocks. #4 AWG (.0mm ) to #0 AWG (4.0mm ) GPF 0 30A GPF 4 75A 77V Power NUMBER OF CIRCUITS MODELS AVAILABLE FOR... FEED TYPE PANEL FEED MAXIMUM FEED BRANCH CIRCUIT BREAKER GPF 8 60A GPF 80A GPF 6 5A

DIMENSIONS FOR GPF 8-4 PANELS Top View 8 (7 mm) Suggested feed wiring entry Suggested load wiring entry 4 (00 mm) Left Side Removable top cover is shipped in the same box as the panel. (50 mm) Front View (50 mm) Right Side 37 (940 mm) 33 (838 mm) 35 (889 mm) 3 (330 mm) Keyhole accepts a maximum of 5/6" (8 mm) mounting bolt (/4" (m8) recommended). Class /PELV entry knockout is 7/8" dia. ( mm) (304 mm) Bottom View (50 mm) Required control wiring entry (304 mm)

MOUNTING FOR GPF 8-4 PANELS Surface mount indoors. Panel generates heat. Mount only where ambient temperature will be 0 C-40 C (3 F-04 F). This equipment is air cooled - vents must not be blocked or you will void the warranty. Leave " (3cm) clearances above, below, and in front of Panel. No clearance necessary on sides. Reinforce wall structure for weight and local codes. GPF 8-4 Front View Feed Raceway Load Circuit Terminal Blocks for Load Circuits GPF 8-4 Side View " (3cm) minimum top and front PANEL MAXIMUM WEIGHT BTUs/HOUR (WITHOUT PACKAGING) GPF8 365 5 lbs (5kg) GPF 045 30 lbs (59kg) GPF6 75 45 lbs (66kg) GPF0 3405 60 lbs (73kg) GPF4 4085 75 lbs (80kg) Dimming Panels will hum slightly and internal relays will click while in operation. Mount where audible noise is acceptable. Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. Panels must be mounted within 7 of true vertical. Main Lugs, " (3cm) minimum air flow Maximum Feed and Wire Sizes Consult Overview page. Water damages Panels! Install Panels in a location where they will not get wet.

MOUNTING ONE PANEL ABOVE ANOTHER You need at least 8' 8" (65cm) between the floor and the suspended ceiling for this layout. GPF 8-4 Front View GPF 8-4 Side View Raceway Feed Load Circuit " (3cm) minimum Class (PELV) Class (PELV) about " (3cm) 3' 4 5/8" (03cm) to mounting holes 6' 6" (95cm) NEC Breaker Height Limit 7' 5 5/8" (8cm) to mounting holes 8' 8" (65cm) minimum to ceiling 6" (6cm) 7 minimum air flow 6" (6cm) approved for this layout only. Water damages Panels! Install Panels in a location where they will not get wet.

GPF 8-4 WIRING OVERVIEW Typical Load Circuit () Red Tips! You wire the GPF 8-4 similar to wiring a lighting distribution panel. You run feed and load wiring. No other wiring or assembly required. Common Neutrals are not permitted. Run separate Neutrals for each load circuit. You can use the GPF 8-4 to provide temporary lighting. Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Circuit Breakers to switch lights on and off. Power (Hot/Live) (3) #4 AWG (.0mm ) to #/0 AWG (70mm ) Feed Neutral () #4 AWG (.0mm ) to #0 AWG (4.0mm ) Neutral () #4 AWG (.0mm ) to #/0 AWG (70mm ) Lutron 3-Wire Fluorescent Dimming Ballast (Hi-Lume, ECO-0, or Compact SE) Dimmed Hot (DH) Switched Hot (SH) Ground DH SH H DH SH () Blue Load () #4 AWG (.0mm ) to #0 AWG (4.0mm ) Bypass Jumpers! Do Not Remove Terminal Block Branch Circuit Breakers Class (PELV) wring.

0V AND 77V LOAD CIRCUITS (GPF 8-4) Lutron 3-Wire Fluorescent Dimming Ballasts (Hi-Lume, ECO-0, and Compact SE) Neutral (White) N Dimmed Hot (Orange) Switched Hot (Black) Hi-Lume, Eco-0 (ECO), or Compact SE Ballast Red Red Load Blue Blue All Load Circuit #4 AWG (.0mm ) to #0 AWG (4.0mm ) DH SH H Ground Load Terminals Where Neutral is Located Consult Overview page for the type of panel your working on. GPF Dimming Panel Load Circuits with Emergency Battery Pack N Neutral (White) Dimmed Hot (Orange) Switched Hot (Black) Dimming Ballast Blue Blue Red Red Blue Blue/White Yellow/Black Red Emergency Ballast Cap the wire that is not being used (Black or Orange depending on input voltage) Black (77V) Orange (0V) White To Neutral DH SH H Yellow Yellow Lamp Lamp (Emergency) Battery Connector Indicator Light Load Terminals GPF Dimming Panel Consult Lutron for approved manufacturers of emergency ballasts. Lutron Hi-lume -lamp, 0VAC Dimming Ballast shown. Wire colors may vary depending on emergency ballast manufacturer.

LOW-VOLTAGE CLASS (PELV) WIRING (ALL MODELS) Pull low-voltage type Class wiring for system communications. Must be daisy-chained! Must run separately from line (mains) voltage. Series 4000 GRAFIK Eye Total length of Control Link may be no more than,000 ft. (60m). Dimming Panel Control Unit Control Interface Wallstations Panel-to-Panel wiring Include one extra #8AWG (.0mm ). Used as a sense line for emergency (essential) lighting. Class (PELV) wiring link has: Two # AWG (.5mm ) conductors for control wiring. One shielded, twisted pair #8 AWG (.0mm ) for data link. GRAFIK 5000/6000 Systems Class (PELV) wiring links for system communications can be up to 4000 feet (0m): Use the -RPTR Interface and GRX-CBL-46L cable for links between 000 feet (60m) and 4000 feet (0m). Wire as shown for links 000 feet (60m) and less. Dimming Panel Processor Panel Control Unit Control Interface Wallstations Power Panel Link Panel-to-Panel wiring Include one extra #8AWG (.0mm ). Used as a sense line for emergency (essential) lighting. User Interface Link to PC Wallstation Links Each Class (PELV) has: Two # AWG (.5mm ) conductors for control wiring. One shielded, twisted pair #8 AWG (.0mm ) for data link. If you use Lutron cable, you can use smaller-gauge wires. If a Class (PELV) wiring link is less than 500 feet (5m), you can use GRX-CBL- 346S: - Two #8AWG (.0mm ) for control wiring. - One twisted, shielded pair #AWG (.65mm ) for data link. - No sense line included - add your own #8AWG (.0mm ). If a Class (PELV) wiring link is 500 to 000 feet (5 to 60m), you can use GRX- CBL-46L: - Two #AWG (.5mm ) for control wiring. - One twisted, shielded pair #AWG (.65mm ) for data link. - One #8AWG (.0mm ) for sense line between Panels. Lutron has also approved smaller-gauge cable from Belden, Liberty, Alpha, and Signature. Ask for Lutron GRAFIK Eye Cable.

CLASS (PELV) PANEL-TO-PANEL WIRING (ALL MODELS) To additional Power Panels Control () # AWG (.5 mm ) : Common : 4VFW Data Link () shielded, twisted pair #8 AWG (.0 mm ) 3: 4: () #8 AWG (.0 mm ) 5: Sense Line To Lighting Controls or Processors 3,4 5 Shield/ Shield/ 3,4 3 4 D 5 3 4 D 5 Data A OK Power Data B OK Data A OK Power Data B OK Common +4VFW Sense Link A Link B 3 4 D 5 C D SELECT CIRCUIT Common Common +4VFW Sense Link A Link B 3 4 D 5 C D SELECT CIRCUIT Common Circuit Circuit Dimming Panel Dimming Panel Notes:. Emergency Power: The additional #8 AWG (.0mm ) wire is a sense line from terminal 5 of another Panel. This sense line allows an Emergency (Essential) Lighting Panel to sense when Normal (Non-Essential) power is lost. If more than one Emergency Lighting Panel needs to sense off a specific Normal Panel. You may have to run a dedicated wire between each pair of Normal (Non-Essential) and Emergency (Essential) panels.. Shield/: Connect shielding as shown. Do not connect to Ground (Earth) or Circuit Selector. Connect the bare drain wires and cut off the outside shield. CLASS (PELV) TERMINAL CONNECTIONS Each low-voltage Class (PELV) terminal can accept only two #8 AWG (.0mm ) wires. Two # AWG (.5mm ) conductors won't fit. Connect as shown. (4) # AWG (.5 mm ) 3 4 D 5 4VFW A OK Sense SELECT CIRCUIT A Circuit Power 3 4 D 5 B C D