Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

Similar documents
Technical Application Guide for UP-SHINE LED Ceiling light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S

Technical Application Guide for UP-SHINE LED Ceiling light

Technical Application Guide for UPSHINE LED Ceiling light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Downlight

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Technical Application Guide for UP-SHINE LED Spotlight

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Track Light

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

FDV BA- Lighting AS BA24-CL76-8WD

Technical Application LED Pendant Light LUZ-PL W-W

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

LED Ceiling Light. Informations. Application notes. Application Areas PS-AL W(-D,-S) Indoor

HIGH LUMINOUS EFFICIENCY

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

LED Panel Light E830J

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

North America Version / Dimming Function. Introduction

DHL-LP-LED Low Profile LED Linear High/Low Bay

LUXCOMFO TM LED Flood Light Datasheet

Tri-level Control HF Sensor

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Corn Light. Applications. Key Features. General Usage. 5years

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

False Ceiling HF Sensors

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

Integrated SensorDIM LED Driver Daylight Monitoring Version

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

CoreLine Waterproof the clear choice for LED

Tri-level Control Sensor

LED ECO PANEL.

Product Specifications

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

LED HIGH BAY LINEAR ECO SERIES

WARRANTY LED ECO PANEL.

Product Specifications

Greenough Enterprises Co., Ltd.

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Technical Application Guide for PHILIPS LED Lamps

LED ECO PANEL.

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Affordable and reliable energy saving LED Lighting Luminaires

LED ECO PANEL.

DIMMING 0-10V Continuous

Tri-level Control HF Sensor

OLUX LED IN-GROUND OSRAM. Datasheet

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Dimmable LED Retrofit Kit

D O M E S T I C LED. Lighting C O M M E R C I A L

Technical application guide

Technical application guide

SUNIDEA CO.,LIMITED.

Vaya Linear LP, White & Mono

MSSD- microwave sensor, Factory Set standard 3 minute delay 50% step dimming. (additional options 20% / 50%, delay from 1 to 20 minutes)

LED Seamless VaporProof Fixture Installation Instruction

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

2018 NORTHERN LIGHTING PRODUCT CATALOGUE

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

WARRANTY LED ECO PANEL.

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

TROFFER RETROFIT KIT (TRK)

ENERGY EFFICIENT LED SOLUTIONS

Company Presentation

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

LED FIXTURE CATALOG. Shining light into the future

Liteharbor Lighting Technology Co., Ltd.

CoreLine Batten the clear choice for LED

LED Panels. We re excited to unveil our new LED Panels. These new LED panels are ideal for commercial use and fit into standard tile grid systems.

LINKABLE UNDERCABINET

SUBSTITUBE T8 CONNECTED TUBE

Welcome. Star Light Technology Group(China)Limited. Star Light Technology Group(China)Limited. Star Light Technology (Shenzhen) Company Limited

LED Outdoor Wall Light Series

LED T8 Tube Standard T8 LED TUBE (L05G-H)

INUI-LEDSDL10 Specification

Dimmable LED Downlight SAA&C-TICK,CE&ROHS Pass

Daylight harvest function to regulate light output for maintaining required lux level

Smart Emergency System DLC L1 L2

INSTALLATION INSTRUCTIONS MEL2 TM SERIES

LED ECO PANEL.

diode led HYDROLUME 24V LED Strip Light 24VDC IP65

PRODUCT DATA SHEET LIGHTING PRODUCTS

Fortimo LED Line Gen2 Module

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

110 lm w STANDARD SERIES

Transcription:

Technical Application Guide for UP-SHIE ED Ceiling light UP-A8-12-18W-SS

Introduction Up-shine surface mounted led ceiling light adopts high lumen SMD led, fire rated PC diffuser with even light output. Super slim design with elegant and modern outline makes it more popular nowadays. Humanized sensor design, by selecting the combination on the switch, sensor data can be precisely set for each specific application. Detection area, hold time and daylight sensor lux setting can be adjustable according to customer s different request, giving them a new and comfortable experience they never had before. Up to 7% energy saving compared to standard CF ong lifetime of 4, hours 12 wide beam angle CCT: 3K 4K 5K 57K o UV/IR light Environment friendly, without Mercury or any other hazardous substances 17.5 48 Application Areas Applicable for corridor, basement, garage, warehouse, monitoring, and other places of energy-saving indoor and outdoor lighting. Certificate Ø3 Ø27 Detection Pattern Ceiling Mounting pattern (Unit: m) ceiling mounting height (m) Wall Mounting pattern (Unit: m) wall mounting height(m) 1 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 High detection area ow detection area

Sensor Function Sensor Indicate Sensor keeping (Full power) Daylight & Microwave Sensor Detection area: 14 degree wide detective beam angle with 5~7 meters distance. Working pattern: With sufficient natural light, when illuminance is more than the setting lux, the light does not switch on when presence detected. With insufficient natural light: When illuminance is less than the setting lux, the light switches on automatically when presence detected. With presence detected, light will never switch off, even the nature light is sufficient. After presence left, any movement detected within time-delay, the light will continuously work for another hold time, then switch off automatically until next movement detected. Sensor Setting: Detection area: Detection area can be reduced by selecting the combination on the DIPswitches to fit precisely each application. Hold time: Refers to the time period the lamp remains at 1% illumination after nomotion detected. Daylight sensor: The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold.when set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light level.5lux: twilight operation, 1lux, 5lux: darkness operation only.

Technical Specifications Model Voltage Power Power Factor umen (±5%) Beam angle CCT ifespan CRI Dimmable Dimension UP-A8-12-18W-SS AC23V 18W.9 171 12 o 3K 4h 8 o Ø3*48mm UP-A8-12-18W-SS AC23V 18W.9 189 12 o 4K 4h 8 o Ø3*48mm UP-A8-12-18W-SS AC23V 18W.9 191 12 o 5K 4h 8 o Ø3*48mm UP-A8-12-18W-SS AC23V 18W.9 191 12 o 57K 4h 8 o Ø3*48mm Driver data Sheet Driver data Sensor Main Power Input rated Voltage AC23V AC23V Frequency 5Hz 5Hz Input Voltage AC2-24V AC2-24V Efficiency 88% o load wattage.4w Total load Wattage 2W±.5W 18W±1W Power Factor.9 Rated input current.2a.1a Full load output Voltage 6-75V Rated output current 2A Output current range 2A±5% Power tolerance ±5% Current output tolerance ±5% Hold time 2S, 6S, 3Min, 1Min Detection distance 5-7m(25%, 5%, 75%, 1%) Daylight Sensor 5ux, 1ux, 5ux, Disable Battery duration Charge Period Short circuit protection PASS Over voltage protection PASS Over temperature protection PASS Withstand voltage AC375V Fixture Compatibility Rated Wattage Electrical Classification Ingress Protection Operating Temp Operating Humidity Storage Temp 18W Ⅱ IP4-2 o C~45 o C ~9% -2 o C~65 o C Wiring Diagram: Switch A A Terminal Block ED Driver ED+ ED- YJ+ YJ- ED+ ED- Z- Z+ ED PCB ' ' Microwave sensor

Spectral Distribution 3K 4K.8.7.6 Max=7372 [1.=2] 1.57 SDCM F3K.8 Max=93 [1.=2].7.6 1.78 SDCM F4K.5.4.3 x=.4397 y=.3998.5.4.3 x=.3763 y=.3761.2.2.1.1.. 38 5 6 7 8 38 5 6 7 8 5K 57K.8 Max=6316 [1.=2] 2.96 SDCM F5K.8 Max=6184 [1.=2] 4.91SDCM F57K.7.7.6.6.5.4.3 x=.345 y=.3535.5.4.3 x=.3291 y=.3428.2.2.1.1. 38 5 6 7 8. 38 5 6 7 8 Photometric Diagram 3K 4K -12-9 -/+18 14 12 9 7. 6.3 5.6 4.9 MH=1m C/18 C9/27 Flux out: 154 lm 3.281ft 17.37,63.32fc 1m 186.9,681.5lx 6.562ft 4.342,15.83fc 2m 46.74,17.4lx 1.33ft 314.84cm 2.66ft 629.68cm -12-9 -/+18 15 12 9 7.5 6.75 6. 5.25 MH=1m C/18 C9/27 Flux out: 1536 lm 3.281ft 2.66,67.6fc 1m 222.4,727.6lx 6.562ft 5.166,16.9fc 2m 55.6,181.9lx 9.65ft 292.75cm 19.21ft 585.49cm 28 4.2 3.5 1.93,7.35fc 2.77,75.73lx 3.99ft 944.52cm 3 4.5 3.75 2.296,7.511fc 24.71,8.85lx 28.81ft 878.24cm 42 2.8 45 3. 56 2.1 1.85,3.957fc 11.68,42.6lx 41.32ft 1259.36cm 6 2.25 1.291,4.225fc 13.9,45.48lx 38.42ft 117.99cm 7-3 3 AVERAGE BEAM AGE(5%): 115.4 DEG 1.4.7-25 -2-15 -1-5 5 1 15 2 25 16.4ft.6947,2.533fc 51.65ft 5m 7.478,27.26lx 1574.19cm Height Eavg, Emax Angle: 115.15deg Diameter 75-3 3 AVERAGE BEAM AGE(5%): 113.9 DEG 1.5.75-25 -2-15 -1-5 5 1 15 2 25 16.4ft.8265,2.74fc 48.2ft 5m 8.897,29.11lx 1463.74cm Height Eavg, Emax Angle: 111.32deg Diameter 5K 57K -12-9 -/+18 15 12 9 7.5 6.75 6. 5.25 MH=1m C/18 C9/27 Flux out: 1624 lm 3.281ft 18.75,68.39fc 1m 21.8,736.2lx 6.562ft 4.688,17.1fc 2m 5.46,184.lx 1.32ft 314.41cm 2.63ft 628.83cm -12-9 -/+18 14 12 9 7. 6.3 5.6 4.9 MH=1m C/18 C9/27 Flux out: 1522 lm 3.281ft 17.57,64.15fc 1m 189.2,69.5lx 6.562ft 4.393,16.4fc 2m 47.29,172.6lx 1.34ft 315.14cm 2.68ft 63.29cm 3 4.5 3.75 2.83,7.599fc 22.43,81.8lx 3.95ft 943.24cm 28 4.2 3.5 1.953,7.128fc 21.2,76.72lx 31.2ft 945.43cm 45 3. 42 2.8 6 2.25 1.172,4.275fc 12.61,46.1lx 41.26ft 1257.66cm 56 2.1 1.98,4.9lx 11.82,43.16lx 41.36ft 126.57cm 75-3 3 AVERAGE BEAM AGE(5%): 115.3 DEG 1.5.75-25 -2-15 -1-5 5 1 15 2 25 16.4ft.751,2.736fc 51.58ft 5m 8.73,29.45lx 1572.7cm Height Eavg, Emax Angle: 115.8deg Diameter 7-3 3 AVERAGE BEAM AGE(5%): 115.2 DEG 1.4.7-25 -2-15 -1-5 5 1 15 2 25 16.4ft.729,2.566fc 51.7ft 5m 7.566,2762lx 1575.71cm Height Eavg, Emax Angle: 115.2deg Diameter

Polar Diagram Comparison -15 O 18 O 15 O -12 O 12 O -9 O 9 O -6 O 14 28 42 56 6 O -3 O 7 O 3 O AVERAGE BEAM AGE (5%): 115.2 DEG C/18, 115.2 deg C3/21, 115.2 deg C6/24, 115.2 deg C9/27, 115.1 deg Driver lifetime & ED light decay rate Driver ifetime ED ight Decay Rate 9 11%.4 ifetime (hours) 8 7 6 5 4 3 2 1 65 o C 75 o C 85 o C 95 o C 15 o C Capacitor Tc ( o C) % uminous Flux 15% 1% 95% 9% 85% 8% 75% FUX.1.5 U'V' 7%. 1 2 3 4 5 6 7 8 9 1 ifetime (hours).35.3.25.2.15 Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at 15 C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be 12 C The highest withstand temperature of ED junction temperature is 15 C 1 Temperature ( o C) 9 8 7 6 5 4 3 2 1 11:13:13 11:31:1 11:49:1 12:7:1 12:25:1 12:43:1 13:1:1 13:19:1 13:37:1 Time 13:55:1 14:13:1 14:31:1 14:49:1 15:7:1 15:43:1 16:1:1 16:19:1 16:37:1 IC Capacitor MOS PCB ED Fitting Environmental temperature The driver lifespan is based on capacitor working temperature.

Installation 1.Take out ceiling light and accessory pack from box. 2. Knock-in the plastic anchor into ceiling, remove screw, take out bracket. 3. Fix bracket with screw into the ceiling. 4. Selecting the combination on switch, sensor data can be precisely set for each specific application. 5. Open junction box, wire "" "" to terminal block and mount ceiling light into the right place. 6. Switch on. OFF O = Brown = Blue Packaging Information SIZE(CM).W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 61*32.5*33.5 1.5 13 1 CTS Q'TY(PCS) VOUME(CBM) 2'' standard container 4'' standard container 41 41 28 82 82 56 Phone: +86 755 2919 7332 Add: 2nd building Dingfeng High-Tech Zone, Fuyuan 1st road, Fu Yong Sub-district, Bao'an, Shenzhen China