University of Warwick institutional repository:

Similar documents
NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

SOLAR THERMAL COOLING TECHNOLOGIES

MULTIPLE BED REGENERATIVE ADSORPTION CYCLE USING THE MONOLITHIC CARBON AMMONIA PAIR

Experimental study on automotive cooling and heating air conditioning system using CO 2 as a refrigerant

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Review of Experimental Evaluation of Adsorption Cooling System Powered By Exhaust Heat of an Automobile

Adsorption refrigeration system using waste heat

Efficient adsorption refrigerators integrated with heat pipes

Effect of Exhaust Gas Temperature on the Performance of Automobile Adsorption Air-Conditioner

A study of Transient Performance of A Cascade Heat Pump System

EFFICIENT ADSORPTION REFRIGERATORS INTEGRATED WITH HEAT PIPES

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Analysis of a Heat Pump System Driven by Gas Engine for Domestic Use

High Efficiency, Residential Gas- Fired Adsorption Heat Pump Water Heater Development

Piles subject to excavation-induced soil movement in clay

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

SOLAR COOLING TECHNOLOGIES

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Adsorption Refrigeration System for Cabin Cooling of Trucks

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

Development of a Sorption Assisted Air Conditioning System Driven by a Solar Air Collector

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Solar Heating and Cooling Systems

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

HFCs or the Old Refrigerants - what is the best Choice?

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

High Efficiency, Residential Gas- Fired Adsorption Heat Pump Water Heater Development

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

K.F. Fong *, C.K. Lee, T.T. Chow

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Experimentation of Heat Pipe Used In Nano-Fluids

Numerical study of heat pipe application in heat recovery systems

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

EXPERIMENTAL INVESTIGATION OF BUBBLE PUMP AND SYSTEM PERFORMANCE FOR A SOLAR DRIVEN 2.5 KW DIFFUSION ABSORPTION COOLING MACHINE

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM

Experimental study and steady-state modelling of a Commercial diffusion-absorption refrigerator

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units

Performance of non-cfc refrigerator driven by chilled water from 35 kw LiBr/H2O solar absorption cooling system

Thermal Performance of a Loop Thermosyphon

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Innovative Air Conditioning for Hybrid and Electric Vehicles

Plate Coil Heat Exchangers

Design, Manufacturing of Chilled Water System for Process Cooling Application

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

POLYMER HOLLOW FIBRE HEAT EXCHANGERS

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses

Cooling Innovation. Adsorption Heat Pumps and Chillers Recent Developments for Materials and Components

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

A SOPHISTICATED, LOW-COST, ENERGY-EFFICIENT, SMALL-CAPACITY LNG VAPORIZER AND ITS PRACTICAL USE

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Global Journal of Engineering Science and Research Management

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

To investigate the surface properties for increasing efficiency of solar water heater

Technical Note. EHPA Quality Label Model Range Definition Version

Performance investigation of Air-conditioning system using ejector as expansion device

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

No matter how adventurous a process engineer may

Transcription:

University of Warwick institutional repository: http://go.warwick.ac.uk/wrap This paper is made available online in accordance with publisher policies. Please scroll down to view the document itself. Please refer to the repository record for this item and our policy information available from the repository home page for further information. To see the final version of this paper please visit the publisher s website. Access to the published version may require a subscription. Author(s): Z. Tamainot-Telto,, S.J. Metcalf, R.E. Critoph Article Title: Novel compact sorption generators for car air conditioning Year of publication: 2009 Link to published article: http://dx.doi.org/10.1016/j.ijrefrig.2008.11.010 Publisher statement: NOTICE: this is the author s version of a work that was accepted for publication in International Journal of Refrigeration. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in International Journal of Refrigeration, [VOL:32, ISSUE:4, June 2009, DOI: 10.1016/j.ijrefrig.2008.11.010

Novel compact sorption generators for car air conditioning Nouveau générateur compact à sorption pour la climatisation automobile Z. Tamainot-Telto (1), S.J. Metcalf and R.E. Critoph School of Engineering - University of Warwick Coventry CV4 7AL United Kingdom (UK) Abstract A prototype compact generator using the activated carbon - ammonia pair based on the plate heat exchanger concept has been designed and built at Warwick University. The novel generator has low thermal mass and good heat transfer. The heat exchanger uses nickelbrazed shims and spacers to create adsorbent layers only 4 mm thick between pairs of liquid flow channels of very low thermal mass. The prototype sorption generator manufactured was evaluated under EU car air conditioning test conditions. The prototype sorption generator is described and its experimental performance reported. While driven with waste heat from the engine coolant water (at 90 o C), a pair of the current prototype generators (loaded with about 1 kg of activated carbon) operating out of phase has produced an average cooling power 1.6 kw with about 2 kw peaks. The typical average COP obtained is 0.22. Keywords: Activated carbon, Air conditioning, Ammonia, COP, Heat exchanger, Generator, Sorption. Résumé Un prototype du générateur compact, basé sur le concept des échangeurs de chaleur à plaques et utilisant la paire charbon actif-ammoniac, a été conçu et construit à l Université (1) Corresponding author: E-mail es2071@eng.warwick.ac.uk - Tel. +44 24 76522108 Fax +44 24 76418922

de Warwick. Le nouveau générateur a une faible inertie thermique et un excellent transfert de chaleur. L échangeur utilise des plaques ayant des micro-canaux et des intercalaires brasés au Nickel pour créer des couches d adsorbant de 4 mm d épaisseur entre les paires de plaques à l intérieur desquelles circule le fluide liquide. Le prototype du générateur à sorption ainsi fabriqué a été testé suivant des conditions prescrites par la Norme Européenne de la Climatisation Automobile. Le prototype du générateur à sorption est décrit et ses performances experimentales présentées. Une paire dudit prototype (contenant chacun 1 kg the charbon actif), operant avec déphasage et ulisant des pertes thermiques en provenance de l eau de refroidissement de moteur (à 90 o C), a produit une puissance frigorifique moyenne de 1.6 kw avec une valeur maximum de 2 kw. La valeur typique du COP moyen est de l ordre de 0.22. Mot clés: Charbon actif, Conditionnement d air, Ammonica, COP, Echangeur de chaleur, Générateur, Sorption. Nomenclature Abbreviations COP MACS NH3 PLATEX SCP Coefficient of performance in cooling Mobile air conditioning system Ammonia Plate type heat exchanger Specific cooling power SOPLATEX Sorption plate heat exchanger Symbols A Surface area (m 2 ) K-value Flow rate corresponding to a pressure drop of 1 bar (m 3 h -1 )

MACS Mobile Air Conditioning System T Temperature ( o C) TEV Thermostatic expansion valve U Overall heat transfer coefficient (W m -2 K -1 ) Subscripts A C E G Adsorption Condensation, Condenser Evaporation, Evaporator Generation, Generator

Introduction In 2005, the first experimental prototype of a compact generator using the monolithic carbonammonia pair was developed at Warwick University. The compact generator was based on the concept of a plate heat exchanger (PLATEX) as illustrated in Figure 1. The main objectives were to demonstrate the manufacturing feasibility of a compact generator based on PLATEX and to evaluate its thermal performance when mounted on a full cooling machine. The mechanical and thermal behaviour of the prototype were satisfactory but the cooling performance obtained (SCP~0.150 kw kg -1 carbon and COP~0.120) were poor but predicted well by a theoretical model [1]. The performance limitations were mainly due to the design and manufacturing process of the prototype [2]. Design improvements were later carried out on the configuration, reducing the thermal mass and enhancing the heat transfer [3]. A new manufacturing process for a fully welded compact generator that withstands both high pressure (up to 30 bar) and high temperature (up 200 o C) is now established. Novel sorption generator The novel sorption generator is a nickel-brazed stainless steel design with 29 layers of active carbon adsorbent each 4 mm thick. By incorporating the carbon adsorbent in thin layers, conduction path lengths through the material are reduced and the area for fluid heat transfer is increased which enables rapid temperature cycling and thus a high SCP. The separating stainless steel plates are constructed from chemically etched shims with 0.5 mm square water flow channels on a 1 mm pitch. These channels give a high heat transfer coefficient and a large heat transfer area, further improving heat transfer performance. The square design ensures equal flow path lengths in every channel and therefore even heating and cooling of the adsorbent. The internal pressure (up to 20 bar when condensing at 50 C) is withheld by the stainless steel shims which act as supporting webs to the outer wall, which only needs to

be 3 mm thick despite being straight. The open end of the front face as shown in Figure 2 is used to insert and remove the adsorbent in order that a range of adsorbents can be tested. Figure 3 shows both a conceptual drawing and a photograph of the unit fitted with water manifolds and pressure flanges prior to testing. The top and bottom ammonia flanges are necessary due to the open face and would be unnecessary in an eventual completely enclosed unit. The end pressure flanges are necessary to prevent deformation of the ends of the unit, but could be replaced by lighter domed ends. After a preliminary test designed to evaluate the heat transfer performance, the full characteristics of the generator were established and are summarized in Table 1. Laboratory cooling system description The laboratory cooling system is designed to simulate a mobile air conditioning system (MACS) for a Class C passenger vehicle (such as a Ford Focus or Fiat Bravo) with a 1.9 litre turbo diesel engine. This choice is very challenging due to the high engine efficiency and therefore low waste heat availability. The engine coolant is to be used to provide the heat input at a temperature of 90 C and a nominal flow rate of 24 litre min -1. The cooling power required has been determined from collaboration between two of the project partners, Energy Research Centre of the Netherlands (ECN) and Centro Ricerche Fiat (CRF), to be 2 kw and, although it is highly variable during the driving cycle, the nominal heat input available is 5 kw - thereby necessitating a nominal COP 0.4. A schematic diagram of the system is shown in Figure 4. The engine coolant is alternately passed through the two generator beds in order to heat them. A second pumped coolant loop is used to recover heat between the two beds. An air-to-water heat exchanger placed in front of the vehicle radiator (labelled adsorption heat exchanger) is used to cool the generator beds to ambient temperature. An interconnecting pipe with a valve is also incorporated which enables the ammonia side of the

two generators to be connected for mass recovery purposes. In this process, the heated high pressure bed is connected to the cooled low pressure bed and ammonia is transferred from the high pressure to the low. This increases the concentration change in the adsorbent during the cycle, thereby increasing SCP and COP. Check valves are used to control the flow of ammonia between the generators and the condenser and evaporator, which are as per a conventional system. One key difference however is the use of an indirect evaporator with an intermediate chilled water glycol loop this prevents leakage of toxic ammonia into the cabin, which could occur with a direct evaporator. Figure 5 and Figure 6 show photographs of various views of the laboratory scale MACS. For the purposes of controlling both the condensing and evaporating temperatures during the experimental tests, an indirect condenser (ammonia/water) and a temperature controlled bath linked to the evaporator (ammonia/water) are utilised. Experimental results and discussions Test were carried out under the Normal European Summer Conditions that are summarized in Table 2. With an operating driving temperature of 80 o C and 1.3 m 3 /h flow on each coolant (source and sink) and with mass recovery, the system met the cooling power target: 1.3 kw vs. 1.2 kw target. However the COP was below the target: 0.23 vs. 0.52. The cooling power achieved corresponds to a power density (the cooling power per unit volume) of 93 W/litre based on generator volume and 62 W/litre based on the total system volume. The specific cooling power (the cooling power per unit mass of carbon) SCP is about 0.650 kw kg -1. With increased driving temperature up to 90 o C, the cooling power increased to 1.6 kw (Figure 7), exceeding the 1.2 kw target by 33%. The COP was 0.22, which is close to the target value of 0.24. The decreased COP obtained with higher driving temperature is due to the fact that the cycle time was not optimised for each condition. The power density was 114 W/litre based on

generator volume and 77 W litre -1 based on total system volume. The SCP is about 0.800 kw kg -1. The effect of coolant flow rates through the generator from 0.46 to 1.25 m 3 h -1 is presented in Figure 8. It can be seen that the effect of the flow rate on performance over the range tested is minimal. The system should therefore not be significantly affected by the variation in the coolant water flow rate from the engine during the driving cycle. The current preliminary performance will be improved when operating the system with both mass and heat recovery and with an optimised control strategy (cycle time). Conclusions A pair of prototype compact generators using activated carbon - ammonia and a plate heat exchanger concept could be used to drive a MACS. With an operating driving temperature of 90 o C and about 1.3 m 3 /h flow on each coolant (source and sink) and with mass recovery, the system met the cooling power target: 1.6 kw vs. 1.2 kw target (33% excess). The COP was 0.22, which is close to the target value of 0.24. However with a lower driving temperature of 80 o C, although the machine meets the cooling power target (1.3 kw vs. 1.2 kw target), the COP is still below the specification (0.23 vs. 0.52). The specific cooling power (the cooling power per unit mass of carbon) ranges from about 0.650 kw/kg up to 0.800 kw/kg. Performance improvements are expected when the system operates with an optimised cycle time. Further developments A second version of the laboratory MACS prototype, that will include the cabin cooler and a direct condenser (ammonia-air) as illustrated in Figure 9, is under construction. The complete chiller unit design is shown in Figure 10. The new generators are made with 12 mm slots aimed at reducing the thermal mass (Figure 11). However a minimum effective

thermal conductivity of 4 to 5 W m-1k-1 is needed in the bed, to equal the performance of the previous 4 mm slot design. This will be achieved by means of thermal enhancement with aluminium fins or use of a carbon mixture with Expended Natural Graphite (ENG). The management of the four streams of water (two on the heat source and two on the heat sink), previously achieved by using eight distinct solenoid valves, will be now be carried out by an electrical 8-way valve that has already been developed (Figure 12). This 8-way valve operates with a ¼ fast turn and low power electrical actuator (1 second, power rate 26 W under 24 Vdc) and is not permanently powered. It is designed for a maximum operating temperature of 100 C and maximum operating pressure of 6 bar; the K-value on each port is approximately 1 m 3 h -1. A CAD picture of the lab package is shown in Figure 13 with a single fan extractor designed to operate both condenser and cooler: the two pipes located on top are for IN/OUT to the heat source; the two pipes located in front are for IN/OUT to the cabin coil. This version will also be tested with a TEV (trials ongoing) at the latest stage in order to reflect further the mobile air conditioning application. Acknowledgements - This research is supported by the EU-TOPMACS project under the grant TST4-CT-2005-012394. - The authors express their gratitude to Chemviron Carbons Ltd (Lockett Road, Lancashire WN4 8DE, UK) for the long standing collaboration in developing activated carbon applied to heat pump and refrigeration systems.

References 1 R. E. Critoph and S. J. Metcalf, Specific cooling power intensification limits in carbonammonia adsorption refrigeration systems, Applied Thermal Engineering, 24 (5-6), 661-679 (2004). 2 Z. Tamainot-Telto, Compact sorption generator Prototype, Proc. International Sorption Heat Pump Conference (ISHPC), Denver (USA), Paper No.ISHPC-065, 8 pages, (2005) 3 R.E. Critoph, Heat Exchanger, UK Patent Application No 0617721.6 (2006) 4 R.E. Critoph, Z. Tamainot-Telto and S.J. Metcalf, "Carbon-Ammonia adsorption cycle machine plate sorption generator", Proc. IIR - International Congress of Refrigeration, Beijing (China), Paper ICR07-B1-622, 8 pages, (2007)

(a) Monolithic Carbon Thermal fluid (Oil) flow (b) Inlet (Oil flow) Ammonia flow channel OD: 84.6 mm 250 mm Outlet (Oil flow) Figure 1: Compact sorption generator (a) Concept based on plate heat exchanger (PLATEX) (b) First experimental prototype (SOPLATEX) [2] Figure 1: Générateur compact à sorption (a) Concept basé sur l échangeur de chaleur à plaques (PLATEX) (b) Premier prototype expérimental (SOPLATEX) [2]

150 mm 150 mm 4 mm Adsorbent Layers 175 mm Etched Water Channels Figure 2: Plate heat exchanger generator design Figure 2: Design du générateur-échangeur de chaleur à plaques

(a) Figure 3: Novel compact sorption generator (a) Concept design (b) Experimental prototype Figure 3: Nouveau générateur compact à sorption (a) Concept du design (b) Prototype experimental (b) Ambient Air Ambient Air Coolant To and From Simulated Engine Generator 1 Adsorption Heat Exchanger (Cooler) Desorption Heat Exchanger Heat Recovery Condenser Mass Recovery Generator 2 Evaporator Receiver Ammonia Water Air Temperature controlled bath Figure 4: Schematic diagram of Laboratory MACS Figure 4: Schéma de la MACS en laboratoire

Figure 5: Lab MACS: Generators and condenser view Figure 5: MACS en laboratoire: vue des générateurs et du condenseur Figure 6: Laboratory MACS: Evaporator and condenser view Figure 6: MACS en laboratoire: vue de l évaporateur et du condenseur

Figure 7: Variation of cooling production Figure 7: Variation de la production frigorifique 1.75 0.25 1.5 0.225 0.2 Cooling Power (kw) 1.25 1 0.75 0.5 COP 0.175 0.15 0.125 0.1 0.075 0.25 0.05 0.025 0 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 Flow Rate (m3/hr) 0 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 Flow Rate (m3/hr) Figure 8: Effect of coolant flow rate on the system performance Figure 8: Influence du debit d eau de refroidissement sur les performances du système

Ambient Air Ambient Air Coolant To and From Simulated Engine Generator 1 Adsorption Heat Exchanger (Cooler) Condenser Heat Recovery Mass Recovery Generator 2 Evaporator Receiver Water/Glycol Ammonia Water Air Cabin Air Out Cabin Cooler Cabin Air In Figure 9: Laboratory MACS Version 2 Figure 9: MACS en laboratoire Version 2

Figure 10: New MACS laboratory prototype Version 2 Figure 10: Nouveau prototype de laboratoire de la MACS Version 2 (a) View without water manifold (b) View with water manifold Figure 11: Photographs of the 2 nd version of new generator under construction (12 mm slot) Figure 11: Photographies de la 2nde version du nouveau générateur en construction (espace de 12 mm)

Figure 12: Prototype of 8-way valve operating with a ¼ turn fast electrical actuator (1 second) Figure 12: Prototype de la vanne à 8 portes operant à ¼ de tour avec un rapide actuateur électrique (1 seconde) Fig 13: Simulated picture of the new Laboratory MACS Package Version 2 Figure 13: Image simulée du nouveau prototype de laboratoire de la MACS Version 2

Table 1: Novel generator specifications [4] Tableau 1: Specifications du nouveau generateur [4] Type of carbon Chemviron SRD1352/3 (compacted) Filter SS Mesh (grade 180) Thermal enhancement None additives Sorbent density 435 kg m -3 Mass of carbon 1 kg Maximum concentration 0.37 kg NH 3 kg -1 carbon Total weight of reactor 9 kg 0perating temperature 200 o C (maximum) Operating pressure 20 bar (maximum) Operating cycle time 60 seconds UA value (water channels) 4150 W K -1 UA value carbon-nh 3 420 W K -1 Bed thermal conductivity 0.42 W m -1 K -1 Overall bed UA value 380 W K -1 Table 2: Typical test of Normal European Summer Conditions and target performance Tableau 2: Norme Europeenne d Essais en Eté et performances requises Normal European Summer Conditions T G Generation inlet ( o C) 80 90 T A Adsorption inlet (liquid) ( o C) 32 T C Condenser inlet (liquid) ( o C) 32 T E Evaporator inlet (liquid) ( o C) 20 Heat source flow rate (Maximum) (m 3 h -1 ) 1.44 Heat sink flow rate (Maximum) (m 3 h -1 ) 1.44 Flow rate Condenser (liquid) (m 3 h -1 ) 0.30 Flow rate Evaporator (liquid) (m 3 h -1 ) 0.30 Target performance Cooling power (kw) 1.2 COP 0.52 0.24