SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Similar documents
SLAG DETECTION SYSTEM CONTINUOUS THERMAL MONITORING

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Infrared Temperature Sensor

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

Coal Pile Fire Monitoring System

ACTIVE INFRARED BARRIER

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

GasGard 100 Control System

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

A New Standard of Excellence

Raytek /Ircon Solutions Guide

M210 Multifunction Micro OTDR

continuous emissions monitoring Combustion & Environmental Monitoring

Film Extrusion, Extrusion Coating, and Lamination Processes

Innovative Technology for Traditional and Challenging Applications

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

Contamination Control for Electronic and Semiconductor Applications

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

M700-Series Multifunction OTDR

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

RLS-3060SH REDSCAN ULTIMATE

Raytek /Ircon Solutions Guide. The Worldwide Leader in Noncontact Temperature Measurement

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

M210 Multifunction Micro OTDR

USER MANUAL USB Multi-Function Datalogger Model RHT35

Dew point set DS 400

Architectural and Engineering Specification for a Security Management System. StarNet 2

Process Alarm Solutions

RAYCHEM NGC-30 COMPONENTS

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Maxline 2 Thermal Imaging Solutions for Manufacturing

DATA CENTER SECURITY. March 2017 Anton Panaitescu

Remote fiber testing to improve SLA s

Measuring Recording Online Monitoring Regulation Alarming

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

DS-2TD Thermal & Optical Network Bullet Camera

AE2200 FTTx Multi-Function Meter

DATAssure. Laboratory wireless alarm & monitoring system

Knürr RMS Compact II. Knürr RMS Compact II 2.81

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Med Touch Master Alarm

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

RS Pro Infrared Temperature Sensor

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Contamination Control for Life Science Applications

Centurion TK50 & WinCem. Infrared Kiln Shell Scanning System

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Gas Detection. Touchpoint Plus. A whole new control experience

Improving Quality and Productivity with Non-Contact Temperature

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

PRO SERIES NONCONTACT TEMPERATURE SENSORS

7800 SERIES RM7888A Relay Module

CAN unit for Analog Sensors

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

Fiber Guardian. Fiber Guardian. Where fiber monitoring starts. Key Features

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

EC2-5x2 Series Condensing Unit Controllers

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

SONOCHEK The ultrasonic testing device

When reliability is vital. Alemite Carbon Shield TM Systems deliver

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

RACK MONITORING SYSTEM - RAMOS Ultra

STEAMPAK Series BurnerPAK BMS Burner Management Systems

SECTION Fluorescent Dissolved Oxygen Measuring System

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

BMS Specification. Lonix Ltd.

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Detection, Protection, Innovation

INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS. IR Windows & AX8 Thermal Imaging Temperature Sensor

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

OPX-BOX. Platform Highlights. Software Support. Key Features

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

SS-100. Pyrometer. Temperature Range: 800~2400

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

/8 DIN Level Indicator

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

User s Manual for ZKIR3 Series IR Day & Night

AirFlow Sensor for Dry Contact connection

SCAN200E USER S MANUAL

Unitronics Demo Case Guide

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Mantraps Airlocks E-gates Turnstiles

FAAST. Fire Alarm Aspirating Sensing Technology

Transcription:

A PRODUCT OF THE SYSTEM 5 FAMILY i 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

SPOT AMETEK LAND HAS BEEN MANUFACTURING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS IN NON-CONTACT TEMPERATURE MEASUREMENT AND COMBUSTION MONITORING WITH APPLICATIONS ACROSS DIVERSE INDUSTRIES SUCH AS STEEL AND GLASS MAKING, POWER GENERATION AND CEMENT MANUFACTURE. As part of AMETEK Process & Analytical Instruments Division since 2006, our customers benefit from the worldwide AMETEK sales and service team. The technologies utilized in SPOT make non-contact temperature measurement accurate, flexible and easy to use. Combining Ethernet, Modbus TCP, Image streaming, Analog and Alarm Outputs within one device, SPOT makes all these conveniently available to the operator. Pyrometer readings and configuration settings are available on the rear display and remotely via a web browser or through SPOTViewer software. The standard body models use a focus assist flashing green patented* LED. The 100 and 160 models offer a fiber-optic variant which uses a red LED to confirm measurement spot size and location. SPOT IS AN INNOVATIVE STAND-ALONE PYROMETER DESIGNED WITH ADVANCED INTEGRATED PROCESSING CAPABILITIES. Flexible design with adapters provide simplified installation and easy replacement of older pyrometers. SPOT is designed to be interchangeable with existing fixed spot pyrometers. Dedicated software extends the usability. AMETEK Land SPOTServer software is a valuable addition allowing you to configure, display and log data from up to 40 different SPOT pyrometers. To ensure security with multiple users, various levels of access are available. Data log frequency, file size, save and archive locations are all configurable. SPOTServer is the perfect choice for smaller operations where traditional process control systems may be absent. F E AT U R E S BENEFITS Single person installation at instrument location and settings; no need for a second control room person Industry standard 4-20 ma linear temperature output Also included: 0-20 ma, 4-20 ma, CMD Out relay, Ethernet (TCP-IP, Modbus TCP, DHCP, http, udp, ICMP) Software Web browser, SPOTViewer for single units FOC from the website, and SPOTServer provides remote display and data logging of multiple SPOT pyrometers STEEL MILL T Y P I C A L A P P L I C AT I O N - B L A S T F U R N A C E Password Access Prevents unauthorized tampering Modbus TCP Widely used and popular industrial protocol over Ethernet Durable Sapphire Protection Window Resists scratches, solvents and easily cleaned with a soft cloth (standard body only) Single Sensor Solution Ideal for use with customer PLCs or DCS systems; no requirement for a separate processor. Easy to implement in small or large organizations Choice of Measurement Location The fiber-optic variant widens your location options with its small optic head. These are ideal for inaccessible locations, areas with high levels of RFI or high ambient temperature environments where water cooling may not be permitted * Patent Pending W W W. A M E T E K - L A N D. C O M L A N D. E N Q U I RY @ A M E T E K. CO M

SPOT 1: SPECIFICATION & DESIGN MONOCHROMATIC PYROMETERS M100, M160 and M210 Standard Body The M-Series pyrometers have a measurement range of 500 to 1800 C / 932 to 3272 F, 250 to 1600 C / 482 to 2912 F and 50 to 1100 C / 122 to 2012 F. Proven, reliable electronics and a precision optical system combine to give a pyrometer which delivers accurate, repeatable temperature measurement. FIBER-OPTIC VARIANTS M100, M160, R100 and R160 The M and R Series fiber-optic versions measure at the same temperature range and wavelength. The use of flexible fiber-optics allows the optic head to be mounted in a hostile environment and the detector and electronics enclosure to be located in a less hostile environment, several meters away. The use of the fiber-optic variant permits measuring of targets that are inaccessible, in areas with high RFI or in high ambient temperature environments where water cooling may not be permissible. ADVANCED PYROMETERS AMETEK LAND OFFERS A RANGE OF MOUNTINGS AND ACCESSORIES FOR 4: HIGH QUALITY OPTICS Features a durable sapphire protection window and ensures precise targeting and quality measurements (not available on fiber optic variant) 2 : Mono 1 - Signal from detector 1 only R100: 550 to 1800 oc / 1022 to 3272 of R160: 550 to 1600 oc / 1022 to 2912 of 3 : Mono 2 - Signal from detector 2 only 4: R100: 400 to 1800 oc / 752 to 3272 of R160: 250 to 1600 oc / 482 to 2912 of Multi - Extended range with low temperature monochromatic and high temperature ratio signal R100: 400 to 1800 oc / 752 to 3272 of R160: 250 to 1600 oc / 482 to 2912 of 6 7 5: INTEGRATED WEB SERVER Allows for remote adjustment and readings via any web browser 6: REAR DISPLAY & CONTROLS Target viewing, temperature reading and set-up through simple menu driven choices; no need for separate software 5 : Duo - Uses detector 2 at low temperatures, detector 1 at high temperatures and both in between R100 Detector 1: 800 to 1800 oc / 1472 to 3272 of R100 Transition : 700 to 800 oc / 1292 to 1472 of R100 Detector 2: 400 to 700 oc / 752 to 1292 of R160 Detector 1: 800 to 1600 oc / 1472 to 2912 of R160 Transition : 700 to 800 oc / 1292 to 1472 of R160 Detector 2: 250 to 700 oc / 482 to 1292 of R210 Detector 1: 300 to 1100 oc / 572 to 2012 of R210 Transition : 200 to 300 oc / 392 to 572 of R210 Detector 2: 125 to 200 oc / 257 to 392 of SPOT MENUS Local user interface 2: PATENTED* PULSED HIGH BRIGHTNESS LED SIGHTING Indicates both target size and location using an easily visible pattern; no laser safety requirements; Fiber-optic variant uses a red LED circle with manual focus 3: SIGNAL PROCESSING All processing features are integrated into SPOT. No need for any separate processor unit 3 1 : Ratio - Combined ratio signal from both detectors R100: 550 to 1800 oc / 1022 to 3272 of R160: 550 to 1600 oc / 1022 to 2912 of 8 7: POWER OPTIONS Power over Ethernet or 24 to 30 V DC at the instrument 8: FIBER-OPTIC VARIANT Optic head and flexible fiber-optic ( on 210 models) SPOTVIEWER Local image view (standard body only) SPOT is designed to be interchangeable with existing fixed spot pyrometers. To view the full range of mountings and accessories available, see our SPOT Mountings and Accessories Brochure. For specific recommendations on the choice of mountings, brackets, cables, or any other accessories, that may suit your specific industry or installation, please contact an AMETEK Land sales manager or representative for further advice before ordering. 4 5 2 The SPOT R100, R160 and R210 offer different operating modes selectable from the set-up menu MOUNTINGS AND ACCESSORIES 1 THROUGH-THE-LENS INTEGRATED CAMERA Easy target alignment and verification in low and high brightness environments (standard body only) SPOTViewer is a PC-based utility that enables you to connect, configure, and view data from a SPOT pyrometer and scan graphs with an Actuator. Specifically developed to work seamlessly with the latest generation of industry leading single point pyrometers. Flexibility of design enables the SPOT R100, R160 or R210 to adapt to multiple temperature measurement scenarios. Change your materials or process parameters and continue to use the same instrument. Updating from an older sensor to SPOT form factor is flexible and easy. Utilize existing mountings and accessories for simple integration and installation. TYPICAL APPLICATIONS Standard Fiber-optic Heat Treatment Heat Treatment Hot Rolling Mill Polysilicon Cement Forging Iron and Steel Steel Metal Forging Induction Heating Carburizing Plasma Nitriding Continuous Galvanizing Lines * Patent Pending W W W. A M E T E K - L A N D. C O M L A N D. E N Q U I RY @ A M E T E K. CO M

SPECIFICATIONS SPECIFICATIONS Measurement Range: Field of View (90% of energy): Detector Type: Display: Settings: Sighting Image: Focus Range: LED Targeting: Mounting: Uncertainty: Repeatability: Resolution: Noise: Sealing: * Patent Pending **Measurements within specification over 5-95% of range R100 R100 F.O. R160 R160 F.O. R210 550-1800 o C /1022-3272 o F (ratio) 400-1800 o C /752-3272 o F (overall) Ratio Short Wavelength; Detector 1: 1.0 µm, Detector 2: 1.2 µm 550-1600 o C /1022-2912 o F (ratio) 250-1600 o C /482-2912 o F (overall) Ratio Short Wavelength; Detector 1: 1.0 µm, Detector 2: 1.5 µm 125-1100 o C / 257-2012 o F 60:1 Ratio Mid Wavelength; Detector 1: 2.1 µm, Detector 2: 2.4 µm Configure locally using the pyrometer interface or remotely (using the Webserver or SPOTViewer). Emissivity, mode, current output range, alarm logic output and thresholds, network settings, focus and LED, language and user name (focus and LED on standard body only) infinity, locally 100 mm to 500 mm infinity, locally 100 mm to 500 mm or manually adjusted or manually adjusted ±0.25% K or 2 K** Full range of mountings and accessories available - see Mountings and Accessories Brochure or visit our website <1 o C 0.1 o C <0.5 o C RMS** IP65 Response Time: Adjustable 1 ms to 10 s Adjustable 15 ms to 10 s Interfaces: Processing Functions: Power Req.: Software: Languages: Ambient Temp. Range: Inputs: Outputs: Warranty: 0-20 ma DC or 4-20 ma DC, Digital CMD In and CMD Out, Ethernet (TCP-IP, Modbus TCP, DHCP, http, udp, TCMP) Peak/Valley Picking, Averager, Modemaster, CMD in sampling, CMD out alarms Power over Ethernet or 24 to 30 V DC at the instrument Live configuration and temperature display on any web browser. Optional SPOTViewer software with datalogging, live and historical data trending, plus remote image, control of multiple instruments (image not available on fiber-optic versions); SPOTServer Software available for use with multiple SPOT pyrometers Integrated multiple language selections: English, German, French, Italian, Spanish, Portuguese (Brazilian), Japanese, Chinese (simplified Mandarin), Korean, Russian, Polish cooling cooling 24 V DC CMD In, Ethernet, (TCP-IP, Modbus TCP, DHCP, http, udp, ICMP) 0-20 ma, 4-20 ma, CMD Out relay, Ethernet (TCP-IP, Modbus TCP, DHCP, http, udp, ICMP) 36 months Measurement Range: Field of View (90% of energy): * Patent Pending **Measurements within specification over 5-95% of range M100 M100 F.O. M160 M160 F.O. M210 500-1800 o C / 932-3272 o F 500-1800 o C / 932-3272 o F 250-1600 o C /482-2912 o F 50-1100 o C / 122-2012 o F Detector Type: Single Wavelength 1.0 µm detector Single Wavelength 1.6 µm detector Single Wavelength 2.3 µm detector Display: Configure locally using the pyrometer interface or remotely (using the Webserver or SPOTViewer). Emissivity, mode, current output range, Settings: alarm logic output and thresholds, network settings, focus and LED, language and user name (focus and LED on standard body only) Sighting Image: Focus Range: 100 mm to 500 mm manually adjusted 100 mm to 500 mm manually adjusted LED Targeting: Mounting: Full range of mountings and accessories available - see Mountings and Accessories Brochure or visit our website 60:1 Uncertainty: Repeatability: Resolution: Noise: Sealing: <1 o C 0.1 o C <0.5 o C RMS** Response Time: Adjustable 1 ms to 10 s Adjustable 10 ms to 10 s Interfaces: Processing Functions: Power Req.: Software: Languages: Ambient Temp. Range: Inputs: Outputs: Warranty: IP65 0-20 ma DC or 4-20 ma DC, Digital CMD In and CMD Out, Ethernet (TCP-IP, Modbus TCP, DHCP, http, udp, TCMP) Peak/Valley Picking, Averager, Modemaster, CMD in sampling, CMD out alarms Power over Ethernet or 24 to 30 V DC at the instrument Live configuration and temperature display on any web browser. Optional SPOTViewer software with datalogging, live and historical data trending, plus remote image, control of multiple instruments (image not available on fiber-optic versions); SPOTServer Software available for use with multiple SPOT pyrometers Integrated multiple language selections: English, German, French, Italian, Spanish, Portuguese (Brazilian), Japanese, Chinese (simplified Mandarin), Korean, Russian, Polish cooling cooling 24 V DC CMD In, Ethernet, (TCP-IP, Modbus TCP, DHCP, http, udp, ICMP) 0-20 ma, 4-20 ma, CMD Out relay, Ethernet (TCP-IP, Modbus TCP, DHCP, http, udp, ICMP) 36 months WWW.AMETEK-LAND.COM LAND.ENQUIRY@ AMETEK.COM

SPOTSERVER Specifically developed to work seamlessly with the latest generation of industry leading single point pyrometers. SPOTServer s simple installation means that the operator can quickly connect, configure and view data from any of AMETEK Land s SPOT range of pyrometers. The AMETEK Land SPOTServer software builds on the features of the SPOT Viewer to provide storage and analysis of data from multiple SPOT pyrometers. A flexible user interface is provided that allows the user to simultaneously display and analyze the data from up to 40 pyrometers. The user can access the SPOT integrated camera image when applicable. Each pyrometer can be configured independently with the freedom to define the storage interval for each of the following: 1: TARGET TEMPERATURE 2: DETECTOR 1 TEMPERATURE 3: DETECTOR 2 TEMPERATURE* 4: AMBIENT TEMPERATURE 5: EMISSIVITY / OBSCURATION* Storage triggers allow the user to define custom criteria to important events and manage how and when to store data. Data can be stored to either Microsoft SQL, XML text file or.csv file. Microsoft SQL provides a database archive that supports complex data queries and the possibility of plant data integration and reporting. *Available on the R100, R100F.O., R160, R160 F.O. and R210 models only. AMETEK Land s AMECare Performance Services ensure peak performance and maximum return on investment over the life of your equipment. We will deliver this by: Proactively maintaining your equipment to maximize availability. Optimizing solutions to meet your unique applications. Enhancing user skills by providing access to product and application experts. AMETEK Land s global service network provides unparalleled after-sales services to ensure you get the best performance and value from your AMETEK Land products. Our dedicated service centre teams and on-site engineers are trained to deliver the highest standard of commissioning, maintenance and after-sales support. SEE OUR OTHER LITERATURE FOR SPOT AND SPOT AL EQS FOR ALUMINIUM APPLICATIONS: SPOT MOUNTINGS & ACCESSORIES SPOT AL EQS ALUMINIUM APPLICATIONS DISCOVER HOW OUR BROAD RANGE OF NON-CONTACT TEMPERATURE MEASUREMENT AND COMBUSTION & EMISSIONS PRODUCTS OFFER A SOLUTION FOR YOUR PROCESS WWW.AMETEK-LAND.COM Land Instruments International Stubley Lane, Dronfield S18 1DJ United Kingdom Tel: +44 (0) 1246 417691 AMETEK Land - Americas 150 Freeport Road, Pittsburgh, Pennsylvania, 15238 United States of America Tel: +1 (412) 826 4444 Applies in the UK Certificate No. CC-2041 Applies in India www.ametek-land.com land.enquiry@ametek.com AMETEK Land China Service Part A1 & A4, 2nd Floor Bldg. 1 No. 526 Fute 3rd Road East, Pilot Free Trade Zone 200131 Shanghai, China Tel: +86 21 5868 5111 ext 122 AMETEK Land India Service Divyasree N R Enclave,Block A, 4th Floor, Site No 1, EPIP Industrial Area Whitefield, Bangalore- 560066 Karnataka, India Tel: +91-80 67823240 For a full list of international offices, please visit our website www.ametek-land.com Applies in the US Copyright 2008-18 LAND Instruments International. Continuous product development may make it necessary to change these details without notice. MARCOM0355 SPOTFAMILY Rev 17