Snifter. User Manual. Distributor

Similar documents
Snifter ATEX22 VERSION. User Manual. Distributor

Sintrol Snifter A1+ Manual. Version 1.2.2

Sintrol Snifter A2 EX. Manual. Version 1.2.3

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Dusty / Dusty Ex Low-Cost Broken Bag Detection

INTRINSICALLY SAFE S314X AND S315X

MONITORING & CONTROL. the expert approach. Dust Sensors.

ProSens Dust Measurement

THE INDUSTRIAL APPROACH TO DUST MONITORING

Dust Alert 75. *shown with optional external keypad and display

Duct and Rough Service Carbon Monoxide Sensor

DMFPM-2R MULTIFUNCTIONAL

RS Pro Infrared Temperature Sensor

GL-CO-RFG Channel Gas Leak Alarm System

OPTISENS TUR 2000 Technical Datasheet

OilSET-1000 (12 VDC)

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Sitron s CF Line of Flow Switch Monitors

SET-2000 Hi Level/Oil

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

PARTICULATE EMISSION MONITORING

Warranty Registration

Class 1 laser beam sensor safe for your eyes

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Class 1 laser beam sensor safe for your eyes

Instruction VIBROCONTROL 850. Single channel vibration monitor. Keep it accessible for future reference.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET Installation and Operating Instructions. Level switch for one sensor

WIO200 Water In Oil measuring instrument

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

MD-MINI Dry Bath. Instruction Manual

Carbon Monoxide Transmitter

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Class 1 laser beam sensor safe for your eyes

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

E3M-V. Mark Sensor. Applications

SET-2000 Oil/Sludge 12 VDC

Analog Room Pressure Monitor RPC Series

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Dust Concentration Meter

Gas cylinder scale Model GCS-1

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Brivis Touch Controller. Installer Manual

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

MODEL WIND TRACKER

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dry Bath Heating Systems

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

OPERATION MANUAL CMW30. Unit Serial Number Range: 0311XXXXCW3 to Present (From March 2011 to Present)

WIO200 Water in oil sensor

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

for relative humidity and temperature with calibration certificates

724A. DustAlarm. Broken Bag Detector. DustAlarm ever requires service either in or out of warranty, please

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

REA 105 Arc Protection Module. Operator s Manual

HTC-915-CONT. Heat-Trace Control system

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

aura-t TP536/GBR ventilation systems

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Manual Comfort Air Curtain

MODEL MARINE WIND TRACKER

Danfoss gas detection unit Type GD Heavy Duty

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

MBCE-110/230FR Flame Sensor Module

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Installation and Operation Manual

Please do not hesitate to contact us with any enquiries.

POLYMIX PX-IG 2000 Operating Instructions

WIO 200B and WIOI200B Water in oil sensor

PRODUCT CONFORMITY CERTIFICATE

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Sensor Control Panel

Instructions for the BASIC BCRW Fan, Sizes General

Installation, Operation and Maintenance Manual

VIBRA-series: VIBRA, VIBRA +

SCHMIDT LED Measured Value Display MD Instructions for Use

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

COMPACT FLAME CONTROLLER CFC 100

aura-t TP536/EU ventilation systems

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Transcription:

Snifter User Manual Distributor Version 1.3 08/09/2009 1

Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 3 1.3 How does it work?... 3 2. INSTALLATION... 4 2.1 Selecting the installation location... 4 2.2 Installing the sensor... 6 3. WIRING... 6 4. TECHNICAL SPECIFICATION... 8 5. DIMENSIONS... 9 6. OPERATION... 10 7. AUTOMATIC SETUP... 11 8. MAINTENANCE... 13 9. TROUBLESHOOTING... 13 9.1. The Monitor is not giving relay output signal... 13 9.2. The Monitor is not responsing after autosetup procedure... 13 NOTES... 14 2

1. INTRODUCTION This manual describes how to install and use SINTROL s triboelectric dust monitor Snifter. Sintrol shall not be liable for any loss or damage whatsoever arising from use of any information or details therein, or omission or error in this manual, or any misuse of the product. 1.1 Safety Snifter requires 12-24 VDC power supply. Although 12-24VDC voltage level is considered safe, but the process gas or dust particulates can be hazardous to health. Take appropriate precautions when installing the monitor: Unless the process conditions are known to be entirely safe, suitable precautions must be taken before any entry is made into the duct for installation or maintenance purposes. The unit may be installed in ducting, containing particulate, hazardous to health. The particulate may be inflammable, explosive or toxic The gas can be hot and pressurised 1.2 Product overview The Snifter Dust monitor is a microprocessor-based, self-adjusting device, equipped with two alarm relays and indication LED in front cover. The Snifter is designed for filter bag leak detection. It can also be used to detect blockage or stoppage in pneumatic transport and bulk solids handling. It is a compact unit with the sensor and control electronics built into one IP65 enclosure, which has been specifically designed for easy installation and operation. The Snifter is designed for applications at up to 2 bar and 140 C. 1.3 How does it work? The Snifter uses proven and reliable triboelectric technology where the interaction of particles with the sensor rod causes a small electrical charge to pass between the particulate and sensor. It is this small electric charge that provides the signal monitored by the electronics, the signal generated is proportional to the dust level even if particles accumulate on the sensor. Experience has shown that this method of monitoring dust level in gasses, offers accurate results with minimum maintenance. 3

2. INSTALLATION 2.1 Selecting the installation location The best location for installation of the units of the Snifter is in a section of duct where the particulate has an even distribution and the flow is as laminar as possible. This is to ensure that the sensor rod comes into contact with a representative flow of particles. The ideal position would be in a section of duct that has no bends, valves, dampers or other obstructions for a distance equal to at least three duct diameters downstream or upstream (preferable 5 x duct diameter). See figure 1. Figure 1. Recommended distances to duct bends (DN=Duct Diameter) In some applications, a compromise must be made and the sensor will have to be fitted in a position that satisfies the majority of above requirements. The Snifter must be attached to metal ductwork so that they will be electrically shielded from interference and be provided with a ground reference. 1. The unit shall be installed in a position, where the gas flow passes the sensor rod in a 90 angle. 2. In round cross-section ducts, the unit can be installed in any position above the horizontal axis (between 9 o clock and 3 o clock). See figure 2a. 3. For square cross-section ducts, the unit must be positioned in the middle of the top or in the middle of one of the sides. See figure 2b. 4. Although the sensor is not affected by vibration, very high vibration levels should be avoided. 5. The units must not be installed in direct sunlight or in areas where the ambient temperature is above 60 C. 4

The unit above horizontal axis The mounting socket in the middle of the side or in the middle of the top Figure 2a. Round cross-section duct Figure 2b. Square cross-section duct Figure 3. Snifter installed on a duct NOTE! The sensor must not contact the opposite wall or any other obstacle inside the duct. The only allowed interaction with sensor is dust particles. 5

2.2 Installing the sensor Once the location of the unit has been selected, the Snifter with BSPT 1/2 male thread can be installed to process adapter with 1/2 female thread. Make sure the installation is in the right position, insert the sensor inside the adapter and rotate the Snifter until the connection is tight. NOTE! Do not over tighten the Snifter with process connection - It may cause damage to sensor and electronics. 3. WIRING Required voltage for Snifter is 12-24 VDC The snifter comes with two meter power and signal cable ready connected. There are 4 pairs (8 wires) in the same cable, two wires for 12-24 VDC and two for relays. Remaining four wires are not in use, they are for factory service/diagnostics purposes. Connect the 12-24 VDC power supply to grey and pink wires. Blue and Red wires are for relays. Blue or Red gives the same voltage like power voltage when relay latches. Both relays must be connected to zero voltage (= 0V) with another wire. CONN1 pin number wire Colour signal name 1 WHITE - 2 BROWN - 3 GREEN - 4 YELLOW - 5 GREY - V- (0 V) 6 PINK - V+ (12-24 VDC) 7 BLUE - relay 1 8 RED - relay 2 Reserved for service/diagnostics 6

Cabling Figure 4. Wiring of power and signal cables (1) Voltage + V+ (12-24 VDC) colour PINK (2) Voltage - V- (0VDC) colour GREY (3) Signal out V (12-24 VDC, I max = 170 ma) color BLUE (4) Signal out V (12-24 VDC, I max = 170 ma) colour RED 7

4. TECHNICAL SPECIFICATION Snifter specifications Measurement objects Particle size Solid particles in a gas flow 0,3 µm or larger Measurement range from 0,1 mg/m 3 Temperature max 140 C Pressure Gas velocity Humidity Measurement principle Damping time Output signals Alarm settings 2 bar Min. 4 m/s 95% RH (non-condensing) Triboelectric (electrostatic/-dynamic detection) 1-300 seconds (predefined) 2 solid state relays (170mA and 200mA ) Alert - 5 x normal dust level Alarm - 20 x normal dust level Ambient temperature - 20 + 60 C Probe Enclosure Protection category Power supply Power consumption Cable (power + signal) Installation Weight SS316 L (220 mm) Aluminium IP65 12-24 VDC 3 W 2 meter 4 pair cable 1/2 BSPT Approx. 0,7 kg This instrument conforms to the following standards Product standard - electrical equipment for measurement, control and laboratory use EMC requirements Reference standard IEC 61326-1:2005 (First Edition) 8

5. DIMENSIONS ½ BSPT Figure 5. Structure and dimensions of Snifter 9

6. OPERATION The Snifter Dust Monitor measures the dust level in a gas flow by monitoring electrostatic/-dynamic discharge when charged dust particles hit or pass near by the probe. There are two solid state relay contact alarm outputs and three colour indicator LED in front cover. The alarm relays are arranged such that relay 2 is ON (=connected) in normal operation. Relay 2 turns OFF and relay 1 ON when dust level exceeds 5x normal dust level and both relays are ON when dust level exceeds 20x normal. The alarm threshold factory default values: Alert: > 5x normal dust level = Limit 1 value Alarm: > 20x normal dust level = Limit 2 value Three state of LED indicator GREEN ORANGE RED NORMAL ALERT ALARM dust concentration dust concentration > 5x NORMAL > 20x NORMAL 10

Relay and LED indicator functions relay on/off relay state Signal level led indicator operation Both relays OFF Power OFF or fault OFF Power OFF or failure Relay 2 ON (alone) Signal < Limit1 GREEN Normal Relay 1 ON (alone) Limit1 < signal < Limit2 YELLOW Alert Both relays ON signal > Limit 2 RED Alarm 7. AUTOMATIC SETUP To be able to detect variations in dust flow, and to set the alarm so that it will go on if there is excessive dust flow, you must determine the typical dust flow in the application when the process is operating normally. The unit has an AUTOMATIC SETUP function. AUTOMATIC SETUP sets the parameters so, the relays gives the alert when the dust concentration exceeds 5x the typical dust level and an alarm when 20x typical level is exceeded. (See table on page 13) Connect the sensor to the duct connect the power on wait 10 minutes start the auto setup procedure close the cover. For AUTOMATIC SETUP you need to know that the process is running with a normal dust flow rate. Then open the cover of the unit, and initiate AUTOMATIC SETUP by pressing the small button, (see Figure 6). The green LED indicator in front cover starts blinking when AUTOSETUP PROCEDURE is going on. AUTOMATIC SETUP procedure takes up to 10 minutes to be completed, green LED in front cover stops blinking and Snifter is ready for use. 11

AUTOSETUP BUTTON Figure 6. Automatic setup button AUTOMATIC SETUP 1. Ensure that the process is in normal conditions. 2. Make sure that the monitor has been connected to process and powered for at least 10 minutes in order to warm up and stabilise! 3. Press the AUTOMATIC SETUP BUTTON (the small button on printed circuit board) Figure 6. 4. Make sure that green LED indicator in front cover starts blinking. NEXT PAGE 5. Turn the cover of enclosure closed and wait for up to 10 minutes until the green LED stops blinking indicating the Automatic Setup sequence has finished. 6. The unit is ready for use. 12

8. MAINTENANCE Snifter Dust Monitor needs very little maintenance. To achieve maximum reliable operation the recommended maintenance interval is 2 months. Maintenance is done by removing the unit from the process and cleaning the sensor rod to prevent signal leakage to ground. If the particles in the gas are sticky and tend to build up, the cleaning needs to be done more often. Check the PC board is firmly connected inside the enclosure. Check LED indicator cable and signal/power cable connectors are connected correctly. 9. TROUBLESHOOTING 9.1. The Monitor is not giving relay output signal 1. Check the power and signal wiring are connected correctly. 2. Check there is power on (cover LED glows). 3. Do the auto setup procedure (green LED starts blinking stops when ready). If the monitor is not giving any relay output signal after checks 1, 2 and 3 contact your local distributor. 9.2. The Monitor is not responsing after autosetup procedure 1. Check that there is normal process going on and there were normal operation conditions during auto setup. 2. Check the power and signal wiring are connected correctly. 3. Check the signal is not leaking to ground. - There is NO contact between metal sensor probe and duct wall. - Ensure the gas is not condensing (causes signal leakage) - Check the sticky dust does not build up on the base of the sensor and no bridging between sensor probe and duct wall. 13

NOTES 14

Sintrol Oy Ruosilantie 15 FI 00390 Finland Tel. +358 9 5617 360 Fax +358 9 5617 3680 15