Snifter ATEX22 VERSION. User Manual. Distributor

Similar documents
Snifter. User Manual. Distributor

Sintrol Snifter A1+ Manual. Version 1.2.2

Sintrol Snifter A2 EX. Manual. Version 1.2.3

S304 and S305 Dust Emission Monitors. User Manual. Distributor

INTRINSICALLY SAFE S314X AND S315X

Dusty / Dusty Ex Low-Cost Broken Bag Detection

ProSens Dust Measurement

OilSET-1000 (12 VDC)

MONITORING & CONTROL. the expert approach. Dust Sensors.

SET Installation and Operating Instructions. Level switch for one sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Hi Level/Oil

DMFPM-2R MULTIFUNCTIONAL

SET-2000 Oil/Sludge 12 VDC

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

RS Pro Infrared Temperature Sensor

THE INDUSTRIAL APPROACH TO DUST MONITORING

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Danfoss gas detection unit Type GD Heavy Duty

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

OPTISENS TUR 2000 Technical Datasheet

GL-CO-RFG Channel Gas Leak Alarm System

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Duct and Rough Service Carbon Monoxide Sensor

Carbon Monoxide Transmitter

Operating Instructions

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Dräger Polytron 5700 IR Detection of flammable gases and vapours

WIO200 Water In Oil measuring instrument

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Fisher LCP100 Local Control Panel

COMPACT FLAME CONTROLLER CFC 100

Sitron s CF Line of Flow Switch Monitors

Dust Alert 75. *shown with optional external keypad and display

4) Intrinsic Safety Certification

MBCE-110/230FR Flame Sensor Module

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Gas cylinder scale Model GCS-1

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

724A. DustAlarm. Broken Bag Detector. DustAlarm ever requires service either in or out of warranty, please

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

RE-PR3-E-27 3-Phase Panel Mount 27kW

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

SolarSET GSM SolarSET GSM with a Beacon

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Instructions for the BASIC BCRW Fan, Sizes General

Instructions for the fan motor control system, SILVER C

PROTECT SRB 200EXi-1A

ExPolar Heating System

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Manual Power relay SR853

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Analog Room Pressure Monitor RPC Series

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Dust Concentration Meter

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

Dräger Flame 2500 Flame Detection

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

MD-MINI Dry Bath. Instruction Manual

24 VAC Intermittent Pilot Gas Ignition Control

COMPACT FLAME CONTROLLER CFC 1000

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

SIMRAD GD10PE IR GAS DETECTOR

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

ISIS SAFETY SYSTEM Installation guide

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Dräger Polytron 7000 Fixed gas detector

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Warranty Registration

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

REA 105 Arc Protection Module. Operator s Manual

Process Alarm Module RTA 421

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

MBCE-110/230FR Flame Sensor Module

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Transcription:

Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009

Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5 2.1. Selecting the installation location... 5 2.2. Installing the sensor... 8 2.3. Installing the Junction Box... 8 3. WIRING... 10 3.1. Connecting Atex22 sensor and Junction Box... 11 4. TECHNICAL SPECIFICATION... 15 5. DIMENSIONS... 17 6. OPERATION... 19 7. AUTOMATIC SETUP... 21 8. MAINTENANCE... 22 9. TROUBLESHOOTING... 22 9.1. The Monitor is not giving relay output signal... 22 9.2 The monitor is not responding after auto setup procedure.... 22 NOTES... 23 2

1. INTRODUCTION This manual describes how to install and use SINTROL s triboelectric dust monitor Snifter. Sintrol shall not be liable for any loss or damage whatsoever arising from use of any information or details therein, or omission or error in this manual, or any misuse of the product. 1.1. Safety Snifter requires 12-24 VDC power supply. Although 12-24VDC voltage level is considered safe, the process gas or dust particulates can be hazardous to health. Sensor is designed for explosive environments fulfilling following ATEX requirements. The Snifter ATEX22 version sensor can be installed in ATEX zone 22 areas. CE II 3 GD Ex mb nl IIC T6 Ex md, IP 65. T80 C VTT 07 ATEX 029X NOTE! Junction Box for Atex22 sensor is not atex approved and cannot be installed in the hazardous area. Take appropriate precautions when installing the monitor: Unless the process conditions are known to be entirely safe, suitable precautions must be taken before any entry is made into the duct for installation or maintenance purposes. The unit may be installed in ducting, containing particulate, hazardous to health. The particulate may be inflammable, explosive or toxic The gas can be hot and pressurised 3

1.2. Product overview Sintrol Snifter Atex22 model consist of two parts: Atex22 sensor which fulfills the ATEX requirement mentioned before and Junction Box which must be installed in the safe zone. Neither of these parts should be used separately but always together. The Snifter Atex22 Dust monitor is a microprocessor-based, self-adjusting device, equipped with two solid state alarm relays and indication LED in front cover of the Atex22 sensor. Junction Box provides two electromechanical relays which are controlled by Atex22 sensor s solid state relays. The Snifter is designed for filter bag leak detection. It can also be used to detect blockage or stoppage in pneumatic transport and bulk solids handling. It is a compact unit with the sensor and control electronics built into one IP65 enclosure, which has been specifically designed for easy installation and operation. The Atex22 sensor is designed for applications at up to 2 bar and 140 C. 1.3. How does it work? The Snifter uses proven and reliable triboelectric technology where the interaction of particles with the sensor rod causes a small electrical charge to pass between the particulate and sensor. It is this small electric charge that provides the signal monitored by the electronics, the signal generated is proportional to the dust level even if particles accumulate on the sensor. Experience has shown that this method of monitoring dust level in gases offers accurate results with minimum maintenance. 4

2. INSTALLATION 2.1. Selecting the installation location SNIFTER ATEX22 Sensor Dust24_cbox_0951 Junction box Figure 1. General layout presentation of Snifter ATEX22-model installation 5

The best location for installation of the Atex22 sensor is in a section of duct where the particulate has an even distribution and the flow is as laminar as possible. This is to ensure that the sensor rod comes into contact with a representative flow of particles. The ideal position would be in a section of duct, having no bends, valves, dampers or other obstructions for a distance equal to at least three duct diameters downstream or upstream (preferable 5 x duct diameter). See figure 2. Figure 2. Recommended distances to duct bends (DN=Duct Diameter) In some applications, a compromise must be made and the sensor will have to be fitted in a position that satisfies the majority of above requirements. The sensor must be attached to metal ductwork so that they will be electrically shielded from interference and be provided with a ground reference. 1. The unit shall be installed in a position, where the gas flow passes the sensor rod in a 90 angle. 2. In round cross-section ducts, the unit can be installed in any position above the horizontal axis (between 9 o clock and 3 o clock). See figure 3a. 3. For square cross-section ducts, the unit must be positioned in the middle of the top or in the middle of one of the sides. See figure 3b. 4. Although the sensor is not affected by vibration, very high vibration levels should be avoided. 5. The sensors must not be installed in direct sunlight or in areas where the ambient temperature is above 60 C. 6

The unit above horizontal axis The mounting socket in the middle of the side or in the middle of the top Figure 3a. Round cross-section duct Figure 3b. Square cross-section duct NOTE! Figure 4. Atex22 sensor installed on a duct The sensor must not contact the opposite wall or any other obstacle inside the duct. The only allowed interaction with sensor is dust particles. 7

2.2. Installing the sensor Once the location of the unit has been selected, the sensor with BSPT 1/2 male thread can be installed to process adapter with 1/2 female thread. Make sure the installation is in the right position, insert the sensor inside the adapter and rotate the sensor until the connection is tight. NOTE! Make sure the Snifter s 1/2 male thread process connection makes the contact to metal duct i.e. ground potential. If the duct or channel where Snifter is mounted is not of metal, the grounding must be done by using separate grounding wire so the enclosure of Snifter is firmly grounded. Sensor rod instead must not contact to the duct s opposite wall or any other obstacle inside the duct. The only allowed interaction with the sensor rod is the flowing dust particles. 2.3. Installing the Junction Box Connect the sensor only to a Junction Box, which is designed for Atex22 sensor. The junction box cannot be installed in potentially explosive atmosphere. See figure 1 in page 5. Junction Box provides additional functionalities for Snifter unit, such as: 45º tilted connectors for easy usage. remote auto-setup button on the cover of the box. two additional electromechanical relays (AC: 240VAC / 6A, DC: 30VDC / 15 A) substitute Atex22 sensor solid state relay signals. Junction Box includes required slow blow fuses for Atex22 sensor. 8

Box is provided with three cable glands attached in the sides for the cabling and one auto setup button mounted on the face of the box. (See figure 5.) POWER, M16 (Cable 5-10mm) SNIFTER, EMC M12 (Cable 3-6mm) POWER-LED & Auto-setup BUTTON RELAYS, M16 (Cable 5-10mm) Figure 5. Junction Box 9

3. WIRING Required voltage for Snifter Atex22 model is 12-24 VDC. The sensor comes with two meter power and signal cable ready connected. There are 4 pairs (8 wires) in the same cable, two wires for 12-24 VDC, and two for relays. All these 8 wires should be connected to Junction Box. NOTE! If the two meter sensor cable is not enough to reach from Ex area to safe area the cable must be extended, Junction Box is not allowed to installed in Ex area. WIRE NO WIRE COLOUR FUNCTION 1 WHITE reserved Not in use 2 BROWN reserved Not in use 3 GREEN Start auto setup Table 1. Wire numbers and colour coding for Atex22 sensor contact to signal cable shield to start the auto setup 4 YELLOW reserved Not in use 5 GREY Input power voltage V- (0VDC ) 6 PINK Input power voltage V+ (12-24 VDC) 7 BLUE solid sate relay 1 V (12-24 VDC, I max = 70 ma) 8 RED solid sate relay 2 V (12-24 VDC, I max = 70 ma) 10

3.1. Connecting Atex22 sensor and Junction Box Before connecting cables inside the Junction Box, prepare cables for terminal screw connection and tighten them well with the glands. Ensure good connection with EMC cable gland. Wire signals to appropriate terminals, as described below. Typical Atex22 sensor signal cable colours are noted in brackets. However, always check the right signal colouring from table 1 to ensure correct connections. Signals from sensor solid state relays directly 1- Relay 2 (red) 2- Relay 1 (blue) EXT con: 1- PWR- (AC/DC) 2- PWR+ (AC/DC) 3- For ext. Button 4- For ext. Button 5- Not in use 6- Not in use 7- Not in use 8- Not in use 9- Not in use Mechanical relays 1- Rel 1 2- Rel 1 3- Rel 2 4- Rel 2 Electromechanical relays are controlled by Snifter solid state relays. 1 2 1 2 3 4 5 6 7 8 9 1 2 3 4 1 2 3 9 8 6 5 4 Figure 6. Wiring the Junction Box 7 Atex22 sensor signals: 1- Relay 1 (blue) 2- Relay 2 (red) 3- V+ (pink) 4- V- (gray) 5- Not in use (yellow) 6- Not in use 7- Auto setup (green) 8- Not in use (brown) 9- Not in use (white) USB-connector and 3 terminals are not in use with this model. Connector for cover button and power led Connect the 8 wires from Atex22 sensor as defined in figure 6 above (Atex22 signals). Connect the 12-24 VDC power supply to the external connector (EXT con) terminals 1 and 2. The power plus to Atex22 sensor is secured with a 500mA slow blow (T) fuse. 11

Relays Junction Box has two additional electromechanical relays (AC: 240VAC / 6A, DC: 30VDC / 15 A), which are controlled by Atex22 sensor solid state relays. There is also possibility to use directly Atex22 sensor solid state relays. Connect the relay load, continuous maximum load 70mA, between the output wire and power supply minus wire. Each relay output is secured with a 100mA slow blow (T) fuse. See figure 6 above. Solid state relay operating When a relay is ON (i.e. makes a contact), it connects its output to power supply plus (+) potential (pink wire). When the relay is OFF, the output is pulled to power supply minus (-) potential (grey wire) by a weak resistor, to allow relay status check using a voltmeter if no relay load is connected to the output. Auto setup When Atex22 sensor is connected to the Junction Box the auto setup can be started by pressing the button on the cover of the Junction Box for 2 seconds. The running of the auto setup is indicated by blinking led in the Atex22 sensor front cover. Auto setup is done after 10 minutes and the Snifter Atex22 is ready for use. 12

NOTE! If the Junction Box is wrongly grounded to local ground, it can make a very harmful ground current loop and Snifter Atex22 doesn t work correctly. NOTE 1: All signals inside Junction Box should be always connected to some terminal. In case the manual advices some signals not to be connected, it is advisable to connect them anyway with incoming terminals. Just do not connect or use those mentioned signals in EXT connector. This way any loose signal cables cannot cause short circuit within the enclosure. NOTE 2: If relays are used to connect high voltage power lines, keep in mind, that separated top right corner of the PCB board will contain deadly voltages. Always ensure that relay connector voltage is shut down, before opening the enclosure. Jumpers in a Junction Box circuit board There are 3 different jumpers J1, J2 and J3 in a Junction Box circuit board. These jumpers are for adjusting functionality. See the list below. Jumper Position 1 Position 2 J1 Chassis as Button GND Power in GND as button GND J2 Not in use Not in use J3 Not in use Not in use NOTE! In Snifter Atex22-model the Jumpers must be positioned in the following way. J1- Position 1 J2- not needed J3- not needed 13

NOTE! When Atex22 sensor is used in ATEX zone 22 environment. following external protection fuses are needed to add to the power supply and output signal wires. Wire6 (PINK COLOR) shall be protected externally using a slow blow 500mA fuse, with > 30Vrated voltage and > 30A breaking capacity. Wire7 (BLUE COLOR) shall be protected externally using a slow blow 100mA fuse, with > 30V rated voltage and > 30A breaking capacity. Wire8 (RED COLOR) shall be protected externally using a slow blow 100mA fuse, with > 30V rated voltage and > 30A breaking capacity. JUNCTION BOX includes these above mentioned slow blow fuses. 14

4. TECHNICAL SPECIFICATION ATEX22 sensor specifications Measurement objects Solid particles in a gas flow Particle size 0,3 µm or larger Measurement range From 0,1 mg/m 3 Range setup Automatic Temperature Max 140 C Pressure Gas velocity Humidity 2 bar Min. 4 m/s 95% RH (non-condensing) Measurement principle Electrostatic charge detection Damping time Output signals Junction Box fuses Alarm settings 3s changeable 1-300 seconds at factory 2 solid state relays (70mA) Ambient temperature - 20 + 60 C Probe Enclosure For power input voltage: a slow blow 500mA fuse, with > 30V rated voltage and > 30A breaking capacity. For each solid state relay: a slow blow 100mA fuse, with > 30V rated voltage and > 30A breaking capacity. Alert - 5 x normal dust level Alarm - 20 x normal dust level SS 316 L (220 mm) Aluminium Protection category Power supply Power consumption Cable (power + signal) Process connection Weight IP65 12-24 VDC 3 W 4 pair, shielded BSPT 1/2 male thread (standard) female 1/2 welding socket (option) Approx. 0,7 kg This instrument conforms to the following standards Electromagnetic Compatibility EMC - electrical equipment for measurement, control and laboratory use EMC requirements IEC 61326-1:2005 (First Edition) ATEX standards EN 60079-0 EN 60079-15 EN 60079-18 EN 61241-0 EN 61241-18 15

Junction box specifications Operating voltage range DC 12 24 VDC Electromechanical relay contacts Rated voltage AC :250 VAC DC: 30 VDC Max current AC: 6 A DC: 15A Breaking voltage 400 VAC Gland sizes 1 x M12 (EMC) metal 3...6 mm cables 2 x M16 plastic 5...10 mm cables Enclosure Material ABS Color Dark grey L x W x D 120 x 80 x 55 mm 16

5. DIMENSIONS ½ BSPT Figure 7. Structure and dimensions of Atex22 sensor 17

Figure 8. Junction Box dimensions 18

6. OPERATION The Snifter Dust Monitor measures the dust level in a gas flow by monitoring electrostatic/-dynamic discharge when charged dust particles hit or pass near by the probe. There are two solid state relay contact alarm outputs and three colour indicator LED in front cover of the Atex22 sensor. The alarm relays arrangements. See next page table 2 Relay 2 is ON (=makes a contact) in normal operation. Relay 2 turns OFF and relay 1 ON when dust level exceeds 5x normal dust level. Both relays are ON when dust level exceeds 20x normal. Note: The electromechanical relays in Junction Box are controlled by the solid state relays with similar functionality. The alarm threshold factory default values: Alert : > 5x normal dust level = Limit 1 value Alarm: > 20x normal dust level = Limit 2 value Three state of Atex 22 sensor LED indicator GREEN ORANGE RED NORMAL ALERT ALARM dust concentration dust concentration > 5x NORMAL > 20x NORMAL 19

Table 2. Relay and LED indicator functions in Atex22 sensor relay on/off relay state Signal level led indicator operation Both relays OFF Power OFF or fault OFF Power OFF or failure Relay 1 OFF Relay 2 ON Signal < Limit1 GREEN Normal Relay 1 ON Relay 2 OFF Limit1 < signal < Limit2 YELLOW Alert Both relays ON signal > Limit 2 RED Alarm 20

7. AUTOMATIC SETUP To be able to detect variations in dust flow, and to set the alarm so that it will be on if there is excessive dust flow, you must determine the typical dust flow in the application when the process is operating normally. The unit has an AUTOMATIC SETUP function. AUTOMATIC SETUP sets the parameters in a way, that the relays give an alert when the dust concentration exceeds 5x the typical dust level and an alarm when 20x typical level is exceeded. For AUTOMATIC SETUP you need to know that the process is running with a normal dust flow rate. The green LED indicator in the front cover blinks when AUTOMATIC SETUP PROCEDURE is going on. AUTOMATIC SETUP procedure takes up to 10 minutes to be completed, green LED in front cover stops blinking after auto setup is done and Snifter is ready for use. AUTOMATIC SETUP 1. Ensure that the process is running in normal conditions. 2. Connect the 12-24 VDC power on. 3. Close the front cover of Junction Box. 4. Make sure that the monitor has been connected to process and powered for at least 10 minutes in order to warm up and to stabilise. 5. When Atex22 sensor is connected to the Junction Box the auto setup can be started by pressing for 2 seconds the button on the Junction Box cover. 6. Make sure the auto setup has started. (Green LED indicator in front cover of Atex22 sensor starts blinking.) 7. Wait for up to 10 minutes until the green LED stops blinking indicating the automatic setup procedure has finished. 8. The unit is ready for use. 21

8. MAINTENANCE Snifter Dust Monitor needs very little maintenance. To achieve maximum reliable operation the recommended maintenance interval is 2 months. Maintenance is done by removing the unit from the process and cleaning the sensor rod from dust build-up to prevent signal leakage to ground. If the particles in the gas are sticky and tend to build up, the cleaning needs to be done more often. 9. TROUBLESHOOTING 9.1. The Monitor is not giving relay output signal 1. Check the power and signal wiring are connected correctly. 2. Check the power is on (LED in cover glows). 3. Do the auto setup procedure (Green LED starts blinking stops when ready). If the monitor is not giving any relay output signal after checks 1, 2 and 3 contact your local distributor. 9.2 The monitor is not responding after auto setup procedure. 1. Check that there is normal process going on and there were normal operation conditions during auto setup. 2. Check the power and signal wiring are connected correctly. 3. Check the signal is not leaking to ground. - There is NO contact between metal sensor probe and duct wall. - Ensure the gas is not condensing (causes signal leakage) - Check the sticky dust does not build up on the base of the sensor and no bridging between sensor probe and duct wall. 22

NOTES 23

Sintrol Oy Ruosilantie 15 FI 00390 Finland Tel. +358 9 5617 360 Fax +358 9 5617 3680 24