Model 341 Black Beauty Slimline

Similar documents
Model 347 BLACK BEAUTY

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

Sonnet Plus Anthem Genesis Soraya

Sonnet Plus Anthem Genesis Soraya

Model BR660VA Heat Engine

OWNER S GUIDE MODEL BR417 VA

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

INSET LIVE FUEL EFFECT GAS FIRE

morsø PANTHER GAS STOVE

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

MODEL 466 Radiant / Convector Gas Fire Black Beauty

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

INSTALLER AND OWNER GUIDE. For further advice please contact the retailer or company from where you purchased your stove

Model 339 Heartbeat Oxysafe 2

Model 939 Heat Engine

Model 804. Chic, Envy, Mirage, Serenity or Twilight fascia.

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Squirrel - Gas Stoves

Model 339 Heartbeat Oxysafe 2

INSTALLER AND OWNER GUIDE

INSTALLER GUIDE. Firefox 8. Model 944. CAST-IRON GAS STOVE Fitted with a Ceramic Coal fuel effect. (GC No )

Firefox 5. Model 910 CAST-IRON GAS STOVE. Fitted with a Ceramic Coal fuel effect. INSTALLER: Please leave this guide with the owner

INSTALLER AND OWNER GUIDE

Model 473 ROOM SEALED RADIANT / CONVECTOR GAS FIRE

Model 939 OPEN DECORATIVE GAS FIRE

Model 347 Black Beauty 4 Oxysafe RADIANT / CONVECTOR GAS FIRE

INSTALLER AND OWNER GUIDE. Model 944 Manual & 944RC Remote Control. CAST-IRON GAS STOVE Fitted with a Ceramic Coal or Log fuel effect.

INSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No )

RADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

INSTALLER AND OWNER GUIDE. Model 944 Manual & Remote Control (RC) GAS STOVE Supplied with a Ceramic Coal or Log fuel effect.

Model 347. Firelite 4 Oxysafe Regency 4 Oxysafe INSTALLER GUIDE. INSTALLER: Please leave this guide with the owner RADIANT / CONVECTOR GAS FIRE

INSTALLER AND OWNER GUIDE

Kalahari RC & Camber RC

INSTALLER AND OWNER GUIDE

Plus Model BR645 VA (G.C )

INSTALLER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

Baxi Bermuda Inset 3 Super

ULTRAFLUE ACCLAIM GAS COAL CONVECTOR

Black Beauty Unigas II

Dovre 250 Cast Iron Gas Stove

THIS PRODUCT IS APPROVED TO THE EUROPEAN GAS APPLIANCE DIRECTIVE

Instructions for Use Installation and Servicing

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE

MODEL 466 Radiant / Convector Gas Fire Black Beauty

INSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire

Broadway, Valor Landscape 2 Gas or Vermont fascia

Mesina Fires GLASS FRONT VENTED Model No. M 70

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

INSTALLER AND OWNER GUIDE. Model 956 INSET MULTIFLUE GAS FIRE

Sonnet Plus Anthem Genesis Soraya

Model 850 ELECTRIC HEATER

Model 474 Valentia Balanced Flue

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

Model 348 Brava RADIANT / CONVECTOR GAS FIRE

Huntingdon 20/30/40. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Model 762 Inset live fuel effect gas fire

Baxi Bermuda GF3/LFE5 Super

Baxi Bermuda Inset 3 Super

INSTALLER GUIDE MODEL BR417 VA. (G.C ) Inset Live Fuel Effect Gas Fire with Ultimate. Front

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Camden, Seattle, Sonnet or Ultimate.

INSTALLER GUIDE. Amour, Aspect, Aspect Glass, Eclipse, Fascination, Landscape, Serenity, Tranquility or Visia

Baxi Brazilia F5, F5S & F8S

Dartmoor. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Baxi Brazilia F 5, F 5S, F 8S & Comfortstat 2 F 8ST

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Model 941 INSET LIVE FUEL EFFECT GAS FIRE

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

INSTALLER AND OWNER GUIDE. Model 807. Electric Heater. Fitted with one of the following fascia

KALIDO 73. Convector Gas Fire MODEL NUMBERS: ACF526NG & ACF526P INSTALLATION, USER AND SERVICING INSTRUCTIONS

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Model 809 Electric Heater

Huntingdon 30. Conventional Flue Coal Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Classic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions

Dovre 280. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

INSTALLER GUIDE. Incorporating the BAXI FIRES DIVISION. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

Hunter Hawk Gas Stove User Instructions

Exmoor. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

Homeflame Bauhaus, Homeflame Dream or Homeflame Harmony. (G.C. Number )

VFC Radiant & Convector

Conventional Flue. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT

INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE

Dovre 280. Conventional Flue Coal Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

E-Studio TM & E-Box TM

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

Transcription:

600B690/13 OWNER GUIDE Model 341 Black Beauty Slimline LIVE FUEL EFFECT GAS FIRE (GC No. 32-032-30) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained satisfactorily. However, if further information is required, our Baxi Fires Division Technical Helpline will be pleased to help. Telephone 08706 061 065 (National call rates apply in the United Kingdom). In the Republic of Ireland Telephone 0044 8706 061 065. This guide is intended to help you care for your Baxi Fires Division gas fire. Please read thoroughly before using and keep for future reference. INSTALLER: Please leave this guide with the owner

THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE). All rights reserved. No part of this publication may be reproduced in any material form (including photocopying), stored in any medium by electronic means (including in any retrieval system or database) or transmitted, in any form or by any means, whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner. Applications for the copyright owner's permission to reproduce any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, Pentagon House, Sir Frank Whittle Road, Derby, DE21 4XA. Warning: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Baxi Fires Division, Erdington, Birmingham B24 9QP www.firesandstoves.co.uk Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication Page 2

Safety First. Baxi Fires Division fires are CE Approved and designed to meet the appropriate British Standards and Safety Marks. Quality and Excellence. All Baxi Fires Division fires are manufactured to the highest standards of quality and excellence and are manufactured under a BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Baxi Fires Division is a CORGI registered company. All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet or floor of combustible material. Page 3

LIST OF CONTENTS Section Page SAFETY 4 APPLIANCE DIMENSIONS 6 GAS CONSUMPTION 6 OPERATING YOUR FIRE 7 CLEANING YOUR FIRE 9 MAINTENANCE 10 USEFUL TELEPHONE NUMBERS 11 This gas fire is designed to meet the most stringent quality, performance and safety requirements to provide you with many years trouble-free service. This guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer. SAFETY IF YOU SMELL GAS! DON T SMOKE.! EXTINGUISH ALL NAKED FLAMES.! DON T TURN ELECTRICAL SWITCHES ON OR OFF.! TURN OFF THE GAS SUPPLY AT THE METER.! OPEN DOORS AND WINDOWS TO GET RID OF THE GAS.! IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY. Do have the fire installed by a competent person. In the United Kingdom, installation must be in accordance with the latest edition of the Gas Safety (installation & use) Regulations. In the Republic of Ireland, installation must be in accordance with all national and local regulations in force. Do have the chimney swept prior to installation if it was previously used for solid fuel. Do have the fire installed in accordance with the installer guide. Do provide a suitable guard that complies with BS 8423 for the protection of young children, the elderly and the infirm. Such a guard is also recommended for the protection of pet animals. (Although this fire conforms to all the applicable standards, it is a heating appliance and certain parts of its surface will become hot). Note: The glass panel supplied with the fire acts as a fireguard conforming to BS1945:1971 and satisfies the Heating Appliance (Fireguard) (Safety) Regulations1991. Page 4

Do wait three minutes before attempting to relight if the fire is switched off or the flames are extinguished for any reason. (Your fire is fitted with a safety device that will automatically shut off the gas supply to the fire if, for any reason, the flames go out). Do get advice about the suitability of any wall covering near your fire. Soft wall coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heating appliance. Please bear this in mind whenever you are considering redecorating. Do allow a minimum clearance of 70mm from the top of the appliance fascia to the underside of any shelf made from non-combustible materials. This clearance is necessary to allow the fascia to be lifted off for servicing. For a shelf made from wood or other combustible materials the minimum clearance from the top of the appliance fascia to the underside of the shelf is 150mm, for combustible shelves deeper than 150mm add 12.5mm to the clearance for every 25mm of additional shelf depth (See graph 1). Please bear this in mind if ever you add a shelf. Graph 1. Combustible shelf clearances Do provide a minimum clearance of 100mm between the fascia sides and any corner wall having combustible material or other combustible surface which projects beyond the front of the fire (See figure 1). Please bear this in mind if ever you are considering altering the room. Don t hang clothing, towels or any other fabrics over the fire. Don t fill in the space behind the fascia. Don t use the fire with a damaged ceramic fuel effect or with the ceramic fuel effect incorrectly positioned. Don t use the fire if the glass window is damaged. Page 5

OWNER GUIDE Don t attempt to clean or service the fire until it has been switched off and allowed to cool completely. Don t allow any combustible material (e.g. Wallpaper, plastic tiling, wood panelling etc) on the surface wall below below the shelf. APPLIANCE DIMENSIONS See graph 1 Figure 1 Dimensions and clearances GAS CONSUMPTION Has a maximum natural gas input of 5.1kW (Gross) Has a maximum natural gas output of 4.0kW Has a minimum natural gas input of 1.55kW (Gross) Has a minimum natural gas output of 1.0kW Page 6

OPERATING YOUR FIRE PLEASE NOTE When operating your fire for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity. These vapours are quite normal with new appliances. They are totally harmless and will disappear after a few hours use. The Oxysafe flame sensing and flue blockage safety system. For your safety, this appliance is fitted with a flue blockage safety device that will shut down the appliance in the event of abnormal flue conditions. This device is NOT a substitute for an independently mounted Carbon Monoxide detector. The device will also automatically shut off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason. If this device starts to repeatedly shut off the gas, get expert advice. This device incorporates a probe that senses that the heat from the pilot flame is correct. If this probe is cool, the device will prevent any gas flow unless the control knob is held down at the ignition position. If, for any reason, the flames go out when the fire is hot or if the fire is turned off when hot, always wait at least three minutes before attempting to relight. To light the fire. The control is shown in Figure 2. Depress the control knob and turn partially to the 1/IGN position until you feel some resistance. Keep the knob depressed at this position for a few seconds to allow gas to flow to the burner. While keeping the knob depressed, turn to the 1/IGN position. While turning, a spark should light the pilot. Keep the knob depressed at the 1/IGN position for a further 10 seconds then release it. The centre section of the ceramic fuel effect will be alight at this position. Figure 2. Depress the control knob slightly and turn it to your desired burner setting. The control knob should be depressed slightly before turning whenever you are Page 7

changing the burner setting. The burner settings are; OWNER GUIDE Control Knob Burner appearance Position 1 / IGN Centre section on low. Outer sections off. 2 Centre section fully on. Outer sections off. 3 Centre section fully on. Outer sections on low. 4 All sections fully on. We recommend that the fire is set at position 4 for the first 10 minutes after lighting to warm up the chimney and so obtain full efficiency quickly. If operating the appliance for long periods it is beneficial occasionally to change the settings. This will also help to remove any carbon deposits that may form during operation. Note: If the fire goes out while setting the control, repeat the full lighting procedure. If the fire repeatedly goes out, have the fire serviced. To turn the fire off. Partially depress the control knob and turn clockwise to OFF. Release the knob. Wait at least 3 minutes after turning the fire off before relighting. Lighting with a taper. In the unlikely event of failure of the ignition spark, the pilot can be lit with a taper or long spill after the window surround has been removed. Removal of the surround is described in the "Window Glass" chapter on the next page. Light the pilot by inserting the taper or spill below the centre of the window while the control is kept depressed at the 1/IGN position (See figure 3). When the pilot has lit follow the rest of the instructions in the section headed "To light the fire". Figure 3. Page 8

CLEANING YOUR FIRE To maintain the high performance and quality finish of your Baxi Fires Division fire, please follow these guidelines: Before attempting to clean the fire, please remember to turn off the fire and wait for the appliance to cool. The fire will retain heat for some time before cleaning can begin. If any pieces of debris are found in the fire box, have the chimney inspected before further use. Metal parts. Clean the metal parts with a slightly damp cloth and then dry. Do not use abrasive cleaners as these will scratch the fire surface. Window glass. Remove any stains on the window with a non-abrasive cleaner such as a ceramic hob cleaner. Do not use abrasive cleaners. The fire has been designed to so that you can remove the window without having to call in a service engineer. This allows you to clean the inside of the window. To remove the window: 1. Detach the window surround by sliding it upward and then swinging the bottom forward. Lift and store carefully (See figure 4). 2. Remove the window unit by removing the screws each side of the window frame and lifting the unit clear. Figure 4. 3. After cleaning, replace and secure the window unit to the firebox with the two screws removed previously. Refit the window surround by sliding the surround upward to locate its upper tabs in the slots underneath the fascia hood. Push the Figure 5. Window surround fitting Page 9

bottom of the surround fully against the fascia cross panel. Drop the surround down so that the two screw heads at the back of the surround locate in the keyholes in the cross panel (See figure 5). Ceramic fuel effect. This product uses a ceramic fuel effect containing Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure to this material may cause temporary irritation to eyes, skin and respiratory tract. Consequently, it makes sense to take care when handling this article to ensure that the release of dust is kept to a minimum. Although light coatings of soot are usually burnt off during normal use, the ceramic fuel effect may benefit from occasional cleaning. Should any soot accumulation become excessive, the fuel effect piece should be removed from the fire for cleaning. Cleaning should be carried out in a well ventilated area or in the open air by gently brushing with the pieces held away from your face so that you avoid inhaling the dust. We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air. The ceramic fuel effect can be lifted out of the fire box when the window surround and glass have been removed as described on page 9. When replacing the ceramic fuel effect, make sure that it rests on the ledges at the sides of the firebox and that its back face is touching the horizontal rib at the back of the firebox (See figure 6). Replace the window and surround after cleaning. MAINTENANCE Figure 6. Ceramic fuel effect location Regular maintenance. In order to achieve and maintain high levels of personal safety and performance efficiency, it is essential that the opening at the back of the fire and the flue are kept clear of any form of obstruction. It is possible that deposits of mortar or soot could fall and accumulate causing the flue to be blocked or restricted and so preventing proper clearance of dangerous exhaust fumes. In the United Kingdom it is the law that a landlord must have any gas appliance, flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person (In the U.K., a CORGI registered installer). Page 10

We recommend that all gas appliances and their flues, wherever situated, are checked annually. Servicing.! In the United Kingdom servicing can be carried out either by a Baxi Fires Division service engineer or a CORGI registered installer.! If you require your fire to be serviced, please contact Baxi Fires Division Service on 08706 090 081 and quote the following details; Model name and number. Appliance serial number (To be found on a label near the bottom left side of the fascia).! If you wish to replace the ceramic fuel effect, spare parts are available nationwide via the interpart stockist network. For your local stockist consult Yellow pages under Central Heating.! When fitting replacement parts, follow the instructions contained in this guide. It is important that only Baxi Fires Division approved parts are used for maximum safety. USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire: BAXI FIRES DIVISION TECHNICAL HELPLINE 08706 061 065. To report faults or arrange for your fire to be serviced: BAXI FIRES DIVISION SERVICE 08706 090 081. For sales or product information: BAXI FIRES DIVISION SALES 08706 061 067. For spares inquiries: Spare parts are available nationwide via the interpart stockist network. For your local stockist consult Yellow pages under Central Heating. CALLERS IN THE REPUBLIC OF IRELAND Call 0044 8706 061 065 Page 11