Heating system service plans that provide total peace of mind.

Similar documents
BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

ANNUAL HVAC SERVICE AGREEMENT

Is a heating protection plan really worth it? Decide for yourself!

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

SERVICE & PAYMENT PLANS. Note from a valued customer LOOK INSIDE FOR OUR NEW BUDGET CHANGES ESTABLISHED 1919

Peerless Boilers. Series MI. Residential Gas Boilers

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

Introducing Hart Air Conditioning

Energy Conservation. Chapter 16

NOW. Fall Heating Specials. Stock Up. & $ave! Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

Boiler & Water Heater

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

Indiana WX Oil Furnace Inspection Guide

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

What is Included with a Seasonal Service?

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

SECTION HEATING BOILERS

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

High efficiency, cast-iron gas boiler

G215 G315 Cast Iron Residential Boilers

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Raypak Residential Products

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

In accordance with the Department of Labor and Industry s statute , Subd. 11,

Intelligent Heating for Your Home

TABLE OF CONTENTS BRADFORD WHITE BOILERS

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

DIVISION FINNED WATER-TUBE BOILERS

Single stage operation oil burner

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Revitalize Building Mechanical Systems (4619)

Glossary. Carbon Dioxide (CO 2

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Heating Maintenance and Repair

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Suggested Specifications Prestige Excellence 110

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FINNED WATER-TUBE BOILERS

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

Warmth, efficiency, and total peace of mind.

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

NJR Home Services General Terms and Conditions Basic Comfort Plans

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

DOMESTIC WATER HEATER OIL FIRED

G124X - G234X - G334X Atmospheric Gas Boilers

CHAPTER UTILITY SYSTEMS-HEATING & AIR CONDITIONING. Utility and General System Notes. Heating and Air Conditioning

Cast Iron Gas Boilers

WATER-TUBE POOL HEATERS

Interrupted Ignition Series Oil Primary Control

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

150 BHP, 3 Pass High-Pressure Fire Tube Boiler mounted in a 53 Trailer

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

DIVISION FINNED WATER-TUBE BOILERS

Single stage operation oil burner

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

WATER-TUBE POOL HEATERS

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

Columbia Boiler Company

Commercial Maintenance Agreement (CMA) Benefits

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

PARTS MANUAL Model Numbers:

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

High Efficiency Commercial Gas Water Heaters

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

Water Fuel + Air for combustion Blowdown

LAARS PENNANT. Economical efficiency for greater savings

COMBUSTION AIR SYSTEM

DIVISION FINNED WATER-TUBE WATER HEATERS

The PurePro. Family of Indirect Water Heaters. A smart choice for abundant, rapid hot water heating. pureproproducts.com

MAX. Installation, Operation and Maintenance Instructions. Residential Oil-Fired Boiler

Copper-Fin GAS-FIRED WATER HEATERS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Cast Iron Oil Boilers

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

OIL-FIRED CENTRAL FURNACE

Solutions to Pollution

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

That s why we call it Smarter from the Ground Up.

BuildingName The Description of the Project P DOCUMENTS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Transcription:

Heating system service plans that provide total peace of mind. Value & Premier Oil Heating System Service Plans Choose the plan that s best for you and your home.

The service plans you need to keep your heating oil system up and running. For more than 80 years, Romanelli Energy has been delivering the best products and services to generations of satisfied customers. Our friendly local team provides satisfaction every day with reliable delivery, expert service and installation, and valuable advice on conserving fuel and saving money. Now more than ever, our knowledge and expertise are helping customers keep their energy costs under control. We re always striving to do our best to bring customers the best products and services. That s why we have comprehensive service plan options to keep your heating oil system working all year while providing the peace of mind you need if any emergency problems do happen.

Oil Heating System Service Plans Just like changing the oil in your car, your oil heating system should be tuned up annually to help reduce the amount of fuel that your system uses, which is good for your energy savings and the environment. Each of our service plans provide you with: Quality repairs by experienced technicians Expert customer service reps to take your calls 24/7 Convenient service hours Annual tune-ups to help you save money 15% discount on non-covered repairs

The Parts

V The Value Plan Extensive coverage for the budget-minded homeowner. V P Fuel & Combustion 1 Air Tube 1 Burner Coupling 2 Burner Fan 2 Burner Motor 3 Cad Cell Eye 3 Cad Cell Relay 4 Combustion Chamber (wet-based, max 2.5 GPH) 5 Delayed Oil Valve 6 Draft Regulator (up to 9" diameter) 1 Electrodes 7 Emergency Switch 1 End Cone 8 Firomatic Valve 9 Fuel Pump 9 Fuel Pump Gasket 9 Fuel Pump Strainer 10 Flue Pipe (max 9" diameter) 11 Igniters 11 Ignition Transformer 1 Nozzle 1 Nozzle Adapter 1 Nozzle Line Oil Check Valve Additional terms and conditions may apply.

P The Premier Plan Comprehensive coverage for peace of mind. 12 Oil Filter Cartridge 12 Oil Filter Complete Oil Safety Valve 1 Porcelains Primary Control 14 Thermostat Standard 15 Thermostat Clock Type ($50 credit) Warm Air 16 Blower Complete (up to 3/4 HP) 17 Blower Motor (up to 3/4 HP) 18 Fan & Limit Control 18 Fan Control Hot Water and Steam Components Air Scoop 19 Aquastat (auto type only) 19 Aquastat Well Automatic Air Vent (boiler room only) Balancing Valve 20 Boiler Drain Valve Boiler Relief Valve (up to 1" diameter) 21 Circulator Complete (kitchen zone up to 1/12 HP) 21 Circulator Components (kitchen zone up to 1/12 HP) V P

Circulator Relay (kitchen zone up to 1/12 HP) Domestic Relief Valve Dual Valve Expansion Tank (max 24 gallons) Expansion Tank Valve Extrol Tank (max # 60) Feed Valve Feed Valve Washer Flow Check Valve 22 Gauge Glass & Washers Limit Control Low Voltage Transformer Manual Feed Valve Pop Safety Valve (up to 1" diameter) Pressure Gauge Pressuretrol (auto type only) 13 Pressure/Temperature Gauge Zone Valve Complete (kitchen zone up to 1" diam.) Zone Valve Component (kitchen zone up to 1" diam.) V P

How your oil-fired heating system works. Heat distribution Oil-fired heating systems distribute heat in one of three ways: warm air through vents, hot water through baseboards, or steam through radiators. Your thermostat senses that room temperature has fallen below your thermostat setting and sends a signal to your heating system to provide heat for your home. When your oil burner is engaged, heating oil travels from the tank to the burner by way of a pump where it becomes a fine mist mixed with air. The fuel/air mixture is then injected into the burner where it is ignited in the combustion chamber. Heating system types Depending on the type of system you have, waterbased or warm air, the system works differently to disperse heat throughout your home. There are two main types of water-based systems: hot water systems and steam systems. Water is heated in either a cast iron or steel boiler before it is dispersed throughout your home. In a hot water system, the heated water is circulated through radiators or baseboards. In a steam system, water turns to steam and rises through pipes to the radiators. In a warm air system, your furnace heats air. A blower then sends the heated air up through ducts and out of vents in your floors or walls. The air gets drawn back to the furnace through a return duct, and the cycle repeats. Finally, emissions from the combustion of fuel and air exit the system through a flue pipe that runs out of your home through the chimney.

Typical Hydronic System Hot water or steam Thermostat Radiator Baseboard Flue Pipe Hot Water Oil Tank Typical Warm Air System Return Duct Thermostat Vent Feed Duct Flue Pipe Oil Tank

Still need more coverage? We have other enhancements and agreements that are available at an additional cost to your existing plan and these are priced separately. They allow you to extend your coverage with more comprehensive protection and help you prepare for unexpected repair costs by allowing you to customize your protection to suit your needs. You must currently have a Romanelli Energy Value or Premier Service Plan to add any enhancement coverage. Optional enhancements 24 Hours-a-Day/365 Days-a-Year Service This enhancement extends your primary coverage by giving you access to Romanelli Energy service 24 hours a day, 365 days a year. It waives our after hours diagnostic fee. Direct and Indirect Water Heater Repair and Part Replacement* This enhancement covers repairs and replacement of the parts listed below: Air tube Aquastat (auto type only) Burner coupling Burner fan Burner motor Cad cell complete Circulator (bronze type, up to 1/16 HP) Delayed oil valve Draft regulator (up to 9" diameter) Drain valve Drip tube Electrodes Electrode wire & clips Emergency switch End cone Firomatic valve Flue pipe (up to 9" diameter) Fuel pump Fuel pump gasket Fuel pump strainer Igniters Ignition transformer Nozzle Nozzle adapter Nozzle line Oil check valve Oil filter cartridge Oil filter complete Oil safety valve Porcelains Preference relay Primary control Relief valve *Covers residential, oil-fired water heaters up to a maximum firing rate of 1.25 gallons per hour. Excludes coverage of the water heater tank, recirculation lines and components, and anode rods. Service requested to start prior to 8:00am or after 5:00pm, on federal holidays (days when the post office is closed), or weekends, is subject to our standard diagnostic fee, unless you have purchased the 24/365 enhancement. Repair and/or replacement must be performed by Romanelli Energy. Limited Boiler and Furnace Replacement** This coverage provides an allowance of $1,000 toward replacement of your main heating boiler or furnace if a Romanelli Energy inspection determines that your existing equipment is not repairable. The new boiler or furnace must be replaced by Romanelli Energy. Allowance is payable as a reduction to our normal retail price for the model specified. **Existing equipment must be inspected by Romanelli Energy to qualify.

Optional Zone Coverage This enhancement covers repair and replacement of the parts listed below: Automatic air vents (boiler room only) Circulator complete (up to 1/12 HP) Circulator coupling (up to 1/12 HP) Circulator flanges and gaskets (up to 1-1/2" diameter) Circulator impeller (up to 1/12 HP) Circulator motor (up to 1/12 HP) Circulator mounts (up to 1/12 HP) Circulator relay Flow check valve (up to 1-1/2" diam.) Isolation valves (up to 1-1/2" diam.) Thermostat (standard) Thermostat (clock type $50 credit) Zone valve (up to 1" diameter) Zone valve motor (up to 1" diameter) Not available on steam systems and excludes air handlers. Service requested to start prior to 8:00am or after 5:00pm, on federal holidays (days when the post office is closed) or weekends, is subject to our standard diagnostic fee, unless you have purchased the 24/365 enhancement. Repair and/or replacement must be performed by Romanelli Energy. Additional agreements CARE Environmental Protection Fortunately, oil releases don t happen too often. But when they do, they can damage the environment and cost thousands of dollars to clean up. And worse, most homeowners insurance doesn t cover oil releases. The CARE program protects your investment in your home by providing clean-up coverage in case your tank, connected piping or oil lines leak. The CARE program is available for above-ground fuel tanks and provides: Up to $100,000 for clean-up (does not include tank replacement) Clean-up of releases from entire fuel oil system, including piping and lines Limited cost share Transferable if you sell your home Experienced professionals to handle the work A separate program is available for underground fuel oil storage tanks. Underground oil tanks require a one-time testing fee in addition to the cost of the program. Oil Tank Agreement In the event of an oil tank failure, this agreement gives you an allowance of $750 toward a replacement tank. Your allowance is payable as a reduction to our normal retail price for the model specified. Replacement or repair must be done by Romanelli Energy. Additionally, this coverage includes: Exposed fill and vent lines (up to 15 from the tank) Exposed oil lines (up to 15 from the tank), tank legs, vent alarm and tank valve

631.956.1201 romanellienergy.com Nassau Lic. No. H3600630000. Suffolk Lic. Nos. 3134-P, 2901-RE. 2018 Romanelli Energy. ACQ_18049