mechanical. OPERATION Rapidrop Global

Similar documents
Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

Instructions for Installation, Operation, Care and Maintenance

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

WATER POWERED OSCILLATING MONITOR

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

TECHNICAL DATA. Wet 26a. February 22, 2009

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Discontinued Product

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Series 759 FireLock Alarm Check Valve

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data. Installation

TECHNICAL DATA OBSOLETE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

TITAN FLOW CONTROL, INC.

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

OPEN SPRINKLER SYSTEM

Installation and Testing of Inverted Bucket Steam Traps Manual

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

TECHNICAL DATA. 319a. January 27, 2012

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

QUICK PRIME INSTALLATION AND SERVICE MANUAL

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

568X, 587X, 588X Series

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

INSTRUCTION MANUAL HS-229G

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

TECHNICAL DATA OBSOLETE

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

55-Gallon Dispenser Package

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

Model 53 Macerator Pump Installation, Operation, Repair Manual

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

BERMAD Fire Protection

Troubleshooting the MPH 24FP Series Pedestal Hydrant

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

TECHNICAL DATA. model c-2

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

INSTALLATION, OPERATION

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

INTERMEDIATE GUIDE BRACKET

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Installation and Maintenance "L" and "LS" Series

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

The Series LFII (TY3596) Residential

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

SECTION FIRE-SUPPRESSION STANDPIPES

55-Gallon Dispenser Package

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

PNLDII-28 Condensate Drain Instruction Manual

Model/Sprinkler Identification Number (SIN) Technical Data

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

INSTALLATION, OPERATION

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

SECTION SPRINKLER SYSTEMS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

HIGH EFFICIENCY CIRCULATOR INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL

LC Series - Light Commercial Pump Station Installation and Operation Manual

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Transcription:

TECHNICAL DATA : MODEL NOMINAL SIZE MAXIMUM SERVICE PRESSURE A 00, 50, 00 & 80 NB Bar (75 Psi) THREADEDOPENING BSPT ( NPT - Optional ) MOUNTING Vertical FLANGECONNECTION ANSI B6. FF #5 (Optional IS:538) TRIM Steel with brass valves FACRY HYDROS TATIC 5 Kg./ Sq.cm. (355 psi) TEST PRESSURE FRICTIONAL LOSS 00NB - 3.00 Mtrs (4.6 ft) IN TERMS OF 50NB - 7.50 Mtrs (4.6 ft) EQUI VALENT LENGTH 00NB - 6.46 Mtrs (. ft) OF PIPE ( C-0 ) 80NB - 3.65 Mtrs (.0 ft) APPROXIM ATE 00NB - 86 Kg. NET WEIGHT 50NB - 5 Kg. WITHOUT TRIM 00NB - 36Kg. 80NB - 8 Kg. FINISH APPRO VAL ORDERING INFORM ATION Alarm Valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. External bypass prevents false alarm under all supply pressure condition. In the event of variable pressure condition,false alarm are prevented with the provision of retard chambe r, thus the design allows for installation under both variable and constant supply pressure condition. Operation of one or more automatic fire sprinklers, the water flows into the sprinkler system and the alarm valve opens, allowing continuous flow of water into the system and transmittal of alarm, both electrical and mechanical. Limited Fire red epoxy painted. UL - listed Size of valve, Flange connection and Trim details. REFERENCE NF PA 3 and NF PA 5 DESCRIPTION mechanical. LISTED 3S38 OPERATION The fire protection system initially when being pressurised, will allow water to flow into the system until the water supply and system pressure is equalised and the clapper closes the waterwa y. Once the pressure is stabilised, the fire protection system is ready to be placed in service and then the alarm control valve must be opened. Under normal condition, the water pressure gauge connected to the system side of the alarm valve would show a higher or equal pressure reading than the water pressure gauge connected to the supply side of the valve. This occurs because the 0 NB bypass line connecting downstream and upstream side of the alarm valve, which allows water pressure surge to pass without lifting the valve clapper off it's seat, thereby causing excessive high pressure surge entrapped in the system side due to presence of a check valve, which generally prevents false alarm. Sudden high pressure surge, as might be encountered by the start-up of a large fire pump may lead the valve clapper to lift momentaril y, allowing water to flow through grooves in the valve seat to the retarding chambe r. The water in the alarm line is automatically drained out, which helps to prevent false alarm due to successive transient surge in supply pressure. Restriction assembly located beneath the retarding chamber consists of an inlet and drain restriction orifice, which are established by considering the volume of the retarding chamber to meet the listing and approval requirement with regard to time-to-alarm. These requirements represent a balancing of the need to reduce the possible false alarm due to a transient surge Continued Overleaf Page of 9

in supply pressure and to achieve desired minimum timeto-alarm following a sprinkler operation. In constant pressure installation, the retarding chamber is not required and the water passing through the groove in the alarm valve seat flows directly through restriction nozzle assembly to activate the mechanical and electrical alarm. INSTALLATION RD. HD Sprinkler alarm valve, Model-A must be installed verticall y.. The alarm valve must be installed in a readily visible and accessible location and provision to be made in such a way that alarm line drain is visible and accessible. 3. Where water pressure fluctuates the variable pressure trim with retarding chamber must be used. Under non-fluctuating water pressure condition, the constant pressure trim, which does not include retarding chamber may be used. 4. The valve must be installed with trim in accordance with the trim data. Failure to follow the appropriate trim connection guidelines may prevent the device from functioning properly as well as void listing, approval and the manufacturer's warrant y. 5. Care must be exercised while installing the check valve in the trim to ascertain that they are located with the arrow mark on the check valve body and pointed in proper direction. 6. The contraction and expansion associated with an excessive volume of trapped air could cause the waterway clapper to cycle open and shut. This may result in false alarm or an intermittent alarm. avoid these, it is recommended to have breather valve in the system piping network and a vent valve at the extreme end of the system to bleed-off the air. To as per the requirement of the system and no damage has taken place to any component. It is recommended that the alarm valve and it's accessories should be examined and performed for following at least quarterly or as demanded by local authorities to ensure reliable and trouble free operation and service.. Inspection and testing is to be carried out only by an authorised person. DO NOT TURN OFF the water supply valve to undertake repair work or to test the valve, without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back into service. Also do inform the local security personnel and alarm control station, so that a false alarm is not signalled.. Open the alarm test valve. Verify that the sprinkler alarm bell and/or the pressure alarm switch/electric alarm properly actuate. Close the alarm test valve and verify that water has ceased to flow from the alarm line drain. 3. Clean the 0 NB (3/4") strainer provided on the sprinkler alarm bell line. 4. Clean the strainer of restriction assembl y. 5. Inspect the 0 NB (3/4") check valve clapper located on the bypass line. FALSE ALARM. Inspect the valve rubber clapper face. If worn or damaged, replace it. Be certain that dirt, stone or any other foreign object have not accumulated under the clapper face and lodged in the groove or holes. Clean the clapper face thoroughl y. If the seat ring surface is nicked or scoured, it might be possible to repair the same using lapping compound. If not, replace the complete valve or return it to the manufacturer's works for repai r. 7. The ball valve provided on the alarm line must be kept open and strapped in set position of the alarm valve. 8. Pipe connecting the retarding chamber and sprinkler alarm bell must be supported properly to avoid loading on the retarding chambe r. 9. All the newly installed system pipes must be flushed properly before alarm valve is put into service. INSPECTION AND MAINTENANCE A qualified and trained person must commission the system. After few initial successful tests an authorised person must be trained to perform inspection and testing of the system. It is recommended to carry out physical inspection of the system at least twice a week. The inspection should verify that all the control valves are in proper position Limited. If sprinkler alarm bell is not functioning or the impeller is jammed, please follow the maintenance guideline provided in the catalogue for sprinkler alarm bell. 3. If pressure alarm switch gives a steady signal, but sprinkler alarm generates an intermittent alarm, check sprinkler alarm bell shaft. If both the sprinkler alarm bell and pressure alarm switch are generating intermittent alarm then check for the possible air which is trapped within the sprinkler system. Trapped air is to be bled-of f. Also the intermittent alarm may occur due to sudden pressure drop and increase in the system. These problems can be corrected by maintaining a steady suppl y. NOTE The listing of UL, approvals & manufacturer's warranty are valid only when the alarm valve is installed with HD trim set and installed as per trim installation guidelines. Page of 9 RD

ALARM VALVE MODEL-A SIZE 00 / 50 / 00 / 80 NB 3 A 0 3 9 8 7 4 5 6 B C PART LIST Limited DIMENSION in millimeter ( Approximate ) VA LVE NOMINAL SIZE A B C 00 NB 43 80 7 50 NB 38 70 54 00 NB 350 40 9 80 NB 35 4 5 PART NO. ITEM 00 50 00 80 DESCRIPTION QTY MATERIAL SPECIFIC ATION NB NB NB NB 6 0 4 Housing Cast Iron 64 04 4 44 Seat Bronze 3 65 05 5 45 Clapper Bronze 4 66 06 6 46 Seat Rubber Neoprene 5 67 08 7 47 Rubber Clamp SS 304 6 90 90 90 90 Bolt (4*) SS 304 7 09 09 09 09 Clapper Bush Bronze 8 0 0 0 0 Body Bush Bronze 9 68 07 8 48 Hinge Pin SS 304 0 9004 9004 9004 90 Bolt 6 Steel 0 0 0 0 Plug Brass 69 9 49 Cover Gasket Neoprene 3 70 30 50 Hand Hole Cover Cast Iron *4 nos for 00NB Alarm Valv Continued Overleaf Page 3 of 9

CONSTANT PRESSURE TRIM FOR ALARM VALVE 00/50/00/80 NB-A TEST & ALARM TRIM OPTIONAL PRESSURE SWITCH OPTIONAL SUIT AT SITE. ONLY FOR 80 & 00 NB SIZE TRIM. ONLY FOR 00 NB SIZE TRIM. 9 9 8 6 7 6 4 7 5 3 8 7 8 3 4 $ 0 5 0 6 7 6 5 9 8 5 3 4 3 NOTE : WHEN PRESSURE SWITCH IS SUPPLIED THEN SL.NO. (PLUG) IS NOT REQUIRED. Limited Page 4 of 9

CONSTANT PRESSURE TRIM FOR ALARM VALVE 00/50/00/80 NB-A Limited T RIM ITEM QUANTITY PER ALARM VA LVE ALARM VA LVE SIZE NO CODE DESCRIPTION SIZE 00NB 50NB 00NB 80NB 9366 HEX NIPPLE ¾ 6 6 7 7 944 PIPE NIPPLE ¾ x 0 mm LONG - - - 944 PIPE NIPPLE ¾ x 80 mm LONG - - - 860 TEE ¾ 4 4 4 4 3 867 ELBOW ¾ 4 9443 PIPE NIPPLE ¾ x 0 mm LONG - - 4 944 PIPE NIPPLE ¾ x 0 mm LONG - - - 4 8660 PIPE NIPPLE ¾ x 5 mm LONG - - - 5 946 PIPE NIPPLE ¾ x 60 mm LONG - 5 8663 PIPE NIPPLE ¾ x 70 mm LONG - 6 895 PIPE NIPPLE ¾ x 50 mm LONG - - - 6 8660 PIPE NIPPLE ¾ x 5 mm LONG - - - 6 944 PIPE NIPPLE ¾ x 0 mm LONG - - 7 868 UNION ¾ 8 94 SWING CHECK VA LVE ¾ 9 945 BALL VA LVE ¾ 0 943 BALL VA LVE ½ 9553 REDUCING HEX NIPPLE ¾ x ½ 9493 REDUCING HEX NIPPLE ¾ x ¼ 3 943 REDUCING HEX NIPPLE ½ x ¼ 4 869 TEE ½ 5 75 COPPER TUBE ASS LY. ½ - - - 5 87 COPPER TUBE ASS LY. ½ - - - 5 36 COPPER TUBE ASS LY. ½ - - - 5 55 COPPER TUBE ASS LY. ½ - - - 6 9477 GAUGE VALVE ¼ 7 9363 HEX NIPPLE ¼ 8 9374 ELBOW ¼ 9 956 PRESSURE GAUGE ¼ HD PART MAKE NO MODE 86PRESSGAUGEFM L-HDP 0 9365 HEX NIPPLE ½ - 0 9396 PIPE NIPPLE ½ x 85 mm LONG - - - 08 RESTRICTION NOZZLE ASS LY. HD RDMAKE 8630 PLUG ¾ 3 8950 PIPE NIPPLE x 80 mm LONG - 3 895 PIPE NIPPLE -/4 x 80 mm LONG - - - 4 9394 ANGLE VALVE - 4 939 ANGLE VALVE -/4 - - - TEST & ALARM TRIM #(OPTIONAL) 5 938 Y TYPE STRAINER ¾ 6 46 SPRINKLER ALARM HD RDMAKE ELECTRIC TRIM FOR PRESSURE SWITCH *(OPTIONAL) 7 9437 REDUCING BUSH ¾ x ½ 8 PRESSURE SWITCH ½ Continued Overleaf Page 5 of 9

VARIABLE PRESSURE TRIM FOR ALARM VALVE 00/50/00/80 NB-A Limited Page 6 of 9

VARIABLE PRESSURE TRIM FOR ALARM VALVE 00/50/00/80 NB-A Limited T RIM ITEM QUANTITY PER ALARM VA LVE ALARM VA LVE SIZE NO CODE DESCRIPTION SIZE 00NB 50NB 00NB 80NB 9366 HEX NIPPLE ¾ 7 7 8 8 944 PIPE NIPPLE ¾ x 0 mm LONG - - - 944 PIPE NIPPLE ¾ x 80 mm LONG - - - 860 TEE ¾ 4 4 4 4 3 867 ELBOW ¾ 4 9443 PIPE NIPPLE ¾ x 0 mm LONG - - 4 944 PIPE NIPPLE ¾ x 0 mm LONG - - - 4 8660 PIPE NIPPLE ¾ x 5 mm LONG - - - 5 946 PIPE NIPPLE ¾ x 60 mm LONG - 5 8663 PIPE NIPPLE ¾ x 70 mm LONG - 6 895 PIPE NIPPLE ¾ x 50 mm LONG - - - 6 8660 PIPE NIPPLE ¾ x 5 mm LONG - - - 6 944 PIPE NIPPLE ¾ x 0 mm LONG - - 7 868 UNION ¾ 8 94 SWING CHECK VA LVE ¾ 9 945 BALL VA LVE ¾ 0 943 BALL VA LVE ½ 9553 REDUCING HEX NIPPLE ¾ x ½ 9493 REDUCING HEX NIPPLE ¾ x ¼ 3 943 REDUCING HEX NIPPLE ½ x ¼ 4 869 TEE ½ 5 75 COPPER TUBE ASS LY. ½ - - - 5 87 COPPER TUBE ASS LY. ½ - - - 5 36 COPPER TUBE ASS LY. ½ - - - 5 55 COPPER TUBE ASS LY. ½ - - - 6 9477 GAUGE VALVE ¼ 7 9363 HEX NIPPLE ¼ 8 9374 ELBOW ¼ 9 956 PRESSURE GAUGE ¼ HD PART MAKE, NO MODE 86PRESSGAUGEFM L-HDP 0 9365 HEX NIPPLE ½ - 0 9396 PIPE NIPPLE ½ x 85 mm LONG - - - 08 RESTRICTION NOZZLE ASS LY. HD RDMAKE 5 RE TARDCHAMBER HD RD MAKE 3 8630 PLUG ¾ 4 8950 PIPE NIPPLE x 80 mm LONG - 4 895 PIPE NIPPLE -/4 x 80 mm LONG - - - 5 9394 ANGLE VALVE - 5 939 ANGLE VALVE -/4 - - - TEST & ALARM TRIM #(OPTIONAL) 6 938 Y TYPE STRAINER ¾ 7 46 SPRINKLER ALARM HD RDMAKE ELECTRIC TRIM FOR PRESSURE SWITCH #(OPTIONAL) 8 9437 REDUCING BUSH ¾ x ½ 9 PRESSURE SWITCH ½ Continued Overleaf Page 7 of 9

CONSTANT PRESSURE TRIM - SCHEMATIC ALARM VALVE 00 / 50 / 00 / 80 NB SYSTEM PG PG PS AT G AV AC DRAIN DRAIN DRAIN FROM SUPP LY VARIABLE PRESSURE TRIM - SCHEMATIC ALARM VALVE 00 / 50 / 00 / 80 NB VARIABLE PRESSURE TRIM - SCHEMATIC ALARM VALVE 00 / 50 / 00 / 80 NB SYSTEM PG PG PS G AT RC AV AC DRAIN DRAIN DRAIN FROM SUPP LY NON RETURN VALVE AV - ALARM VALVE GAUGE VALVE G - SPRINKLER ALARM ANGLE VALVE PG - PRESSURE GAUGE STRAINER RESTRICTION NOZZLE ASSEMB LY PS - PRESSURE SWITCH RC - RE TARD CHAMBER NOTE : ) Sprinkler Alarm Control Valve must be kept normally open, if this valve is kept closed, sprinkleralarmbell/ electricalarm willnotoperate. ) Sprinkler Alarm Test Valve must be kept in normally closed condition. Valve is opened to test the sprinkler alarm bell / electric alarm. SP VA LVE AC - SPRINKLER ALARM CONTROL VALVE OPTIONAL AT - SPRINKLER ALARM TEST VALVE BY USER ( NOT IN HD SCOPE RD OF SUPP LY ) Limited Page 8 of 9

c Data Sheet 5.8 Alarm Valve -ModelA OVERALL DIMENSIONS WITH TRIM ALARM VALVE 00 / 50 / 00 / 80 NB-A D D E E SPRINKLER ALARM C D SPRINKLER ALARM DRAIN A B DRAIN DRAIN A B DRAIN INSTALLATION MEASUREMENT IN MM. ( Approximate ) SIZE 00NB 50NB 00NB 80NB A 40 400 380 350 B 60 600 550 550 C 790 750 70 70 D 40 30 30 30 E 30 90 90 90 INSTALLATION MEASUREMENT IN MM. ( Approximate ) SIZE 00NB 50NB 00NB 80NB A 40 400 380 350 B 550 530 490 490 C 790 750 70 70 D 40 30 30 30 E 30 90 90 90 LIMITED WARRANTY Products supplied by Rapidrop (RD). are warranted against defects in material and workmanship for a period of Two () years from the date of shipment. RD s obligation under this warranty is limited to replace or repair the products or its parts, which are shown to RD s examination to be in a defective condition attributable to RD. No warranty is given for products or components which have been subject, to misuse, improper installation, corrosion, wear and tear, und the purchase price of the equipment in complete discharge of its obligation under this Limited Warranty. IN NO EVENT SHALL RAPIDROP LTD. BE LIABLE IN CONTRACT, STRICT LIABILITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL, IN-DIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING DAMAGES. FOR INJURY PERSON OR DEATH OR DAMAGE PROPERTY AND OR PENALTIES RESULTING FROM ANY PRODUCTS OR COMPONENT MANUFACTURED OR ASSEMBLED BY RD. THIS IS LIMITED WARRANTY ONLY. RD DISCLAIMS WITH RESPECT THE PRODUCTS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY RD BEYOND AS STATED ABOVE. NOTICE : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our reach. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of Rapidrop and hence t served with the company. Limited Page 9 of 9