Air Conditioning Technical Data Concealed ceiling unit EEDEN3-3 ABQ-A
Indoor Unit Concealed ceiling unit ABQ-A TABLE OF CONTENTS ABQ-A Features............................................................. 2 2 Specifications....................................................... 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 3 3 Safety device settings............................................. 4 Safety Device Settings............................................... 4 4 Dimensional drawings............................................. 5 Dimensional Drawings............................................... 5 5 Piping diagrams.................................................... 6 Piping Diagrams..................................................... 6 6 Wiring diagrams.................................................... 7 Wiring Diagrams - Single Phase.................................... 7 7 Sound data.......................................................... 8 Sound Pressure Spectrum........................................... 8 8 Fan characteristics................................................. 9 Fan Characteristics.................................................. 9 Split - Sky Air Indoor Unit
Indoor Unit Concealed ceiling unit ABQ-A Features tkc is nd U- e l rat oeai oc- dl Qn np Bo I SAC Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Compact dimensions, can easily be mounted in a narrow ceiling void Air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation and maintenance 2 Split - Sky Air Indoor Unit
Indoor Unit Concealed ceiling unit ABQ-A 2 Specifications 2- Technical Specifications AB Q25 A ABQ 40A Dimensions Unit Height/Width/ mm 378/,388/54 378/,588/54 Depth Packed unit Height/Width/ mm 45/,497/63 45/,70/63 Depth Weight Unit kg 50.0 56.0 Packed unit kg 54.0 62.0 Packing Material Carton / EPS-Foam / strap Fan Air flow rate Cooling Super cfm,430,720 high High cfm,320,550 Nom. cfm,230,340 Low cfm,30,70 Heating S uper cfm,430,720 high High cfm,320,550 Nom. cfm,230,340 Low cfm,30,70 External static Super high Pa 47 pressure High Pa 26 20 Nom. Pa 09 90 Low Pa 92 69 Fan motor Drive Direct drive Speed Cooling High/ Mediu m/low rpm,320/,230/,30,245/,085/975 Heating High/ Mediu m/low rpm,320/,230/,30,245/,085/975 Sound power level Cooling Super high/high/ dba 78/76/73/70 79/78/75/7 Nom./Low Heating High/Nom./Low dba 76/73/70 78/75/7 Sound pressure level Cooling Super high/high/ dba 53/52/50/47 55/53/50/47 Nom./Low Heating S uper high/high/ Nom./Low dba -/52/50/47 -/53/50/47 Refrigerant Type R-40A Piping connections Liquid OD 9.52 Gas OD 5.88 3 2 2-2 Electrical Specifications AB Q25 A ABQ 40A Power supply Name V Phase ~ Frequency Hz 50 Voltage V 230 Cur rent Nominal running Cooling A.74 2.42 current (RLA) - 50Hz Heating A.74 2.42 Split - Sky Air Indoor Unit 3
3 Safety device settings 3 - Safety Device Settings Indoor Unit Concealed ceiling unit ABQ-A 3 4 Split - Sky Air Indoor Unit
Indoor Unit Concealed ceiling unit ABQ-A 4 Dimensional drawings 4 - Dimensional Drawings 3 4 Split - Sky Air Indoor Unit 5
5 Piping diagrams 5 - Piping Diagrams Indoor Unit Concealed ceiling unit ABQ-A 5 6 Split - Sky Air Indoor Unit
Indoor Unit Concealed ceiling unit ABQ-A 6 Wiring diagrams 6 - Wiring Diagrams - Single Phase 3 6 Split - Sky Air Indoor Unit 7
7 Sound data 7 - Sound Pressure Spectrum Indoor Unit Concealed ceiling unit ABQ-A 7 8 Split - Sky Air Indoor Unit
Indoor Unit Concealed ceiling unit ABQ-A 8 Fan characteristics 8 - Fan Characteristics 3 8 Split - Sky Air Indoor Unit 9
8 Fan characteristics 8 - Fan Characteristics Indoor Unit Concealed ceiling unit ABQ-A 8 0 Split - Sky Air Indoor Unit
Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intenti on to become a leader i n the provision of products that have limited i mpact on the environment. This chall enge demands the eco desi gn and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chill ing Packages (LCP) and Fan coil units (FCU), Check ongoing validity of certifi cate online: www.eurovent-certification.com or usi ng: www.certif lash.com The present leaflet is drawn up by way of informati on only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this l eaflet to the best of its knowl edge. No express or i mplied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Dai kin Europe N.V. expl icitly rejects any liabi lity for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of thi s leaflet. Al l content i s copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: N aamloze Ve nnootschap - Zandvoordestraa t 30 0, B-8400 Oostend e - Be lgium - w ww.d aikin.eu - BE 042 20 336 - RPR Ooste nde EED EN3-3 0 /3 Cop yrigh t Da ikin The present publication supersedes EEDEN2-3