lumenalpha downlight Specification Sheet

Similar documents
Vaya Linear LP, White & Mono

PROJECT DATE FLANGE FINISH

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Essenza. Round Downlights

CCT LED ARCHITECTURAL MINI

3.75 Gyro Shift Multiples Single Head

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

Series / Housing Style Lumens CCT CRI Beam Driver Voltage 2 Options. 80CRI 15D 15 beam 35D 35 beam 45D 45 beam

Murro HP. 3.5" Round Surface Canopy Wall Wash

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Grüv Flare Regressed. Recessed Linear LED

M100 My White LED Direct Tunable White

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Essenza. Square Downlights

LUXCOMFO TM LED Flood Light Datasheet

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Hornet HP. Semi-Recessed 4-Light Square Multiple

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

Grüv Flare Regressed. Recessed Linear LED

RECESSED T-Bar & Drywall

M60 LED Recessed Wet Location

DIMMING 0-10V Continuous

Performance Chart Electrical Data

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

Performance Chart Electrical Data

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Velato. Recessed Slot Adjustable Multiples

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Hornet HP. Round Glass Downlight

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Performance Chart Electrical Data

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

Highbay Linear LED Series Flat Profile Design

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

New Linear Series DISCONTINUED

Evoke 2.9" HP. 2.9" Square Downlight

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

5 IC 600 LUMEN WARMDIM LED DOWNLIGHT REMODEL

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

LHBXD LED Linear High Bay

Evoke 2.9" HP. 2.9" Square Downlight

Classix 6" 6" Round Lens Wall Wash

ArtLED Gallery and Museum Spotlights

DOWNLIGHT 800/1200/1500 LUMEN ROUND APERTURE REMODEL AX2 DR

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

HORNET-HP-R- A14-3 3LT LED

Evoke Square Downlight

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

Classix 6" 6" Round Lens Wall Wash

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Etch 2' x 2' Recessed LED

Catalog # Project. Comments. Prepared by

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

NOVA CEILING WALL GRAZER WITH REMOTE POWER

RLN Recessed LED luminaire

JEDI. Powerful recessed linear LED projector. Views

JEDI. Powerful recessed linear LED projector. Views

Performance Chart Electrical Data

M36 My White LED Direct

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

Catalog Number. Notes

HIGH CEILING ID+ RIGHT LIGHT LUMEN OUTPUT Wall Wash , 3000, 4000* Lumens Downlight , 5000, 6000, 7000** Lumens HIGH CEILING FAMILY

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

800 TO 9000 LUMEN 10 LED RETRO-FIT HYPERBOLIC / PARABOLIC LRT10 SERIES

JEDI COMPACT IP67 INTEGRAL

Alliance 4 - ALI4 LED 4 Linear High Bay

Evoke Square Downlight

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

RECESSED - WITH StepLens OPTION

Fino Healthcare. Asymmetric Wall Mount Indirect LED

ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit

FDV BA- Lighting AS BA24-CL76-8WD

Evoke Square Downlight

PRELIMINARY PRODUCT CODE TYPE LOCATION DRIVER OPTICS LENGTH WATTAGE COLOR TEMP CABLE 3 + MOUNTING. Wall Grazer. Flood 32ºx85º K E End

Classix 6" 6" Round Adjustable C3

LOW PROFILE 4 APERTURE UP TO 4800 LUMENS DELIVERED LLP4/LLPRM4 SERIES

Max 4 Flush Lens RECESSED

Hornet HP. Recessed 4-Light Square Multiple

Dimensions (111mm) (111mm) 3 (76mm)

LED RETROFIT CONVERSION KITS

Truss Surface SURFACE

SDL4 LED Strip Diffused Lens

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

BAS SDL8' LED Strip Diffused Lens

Classix 6" 6" Round Lens Wall Wash

PRODUCT CODE FIXTURE COLOR OPTICS WATTAGE COLOR TEMP + HOUSING DRIVER VOLTAGE

Classix 6" 6" Round Lens Downlight

Transcription:

Client Project name Order# Type Qty FEATURES AND BENEFITS Physical Housing material: aluminum housing Reflector material: metallized polycarbonate Trim finish: white, black, gray or custom RAL color Fixed tilt, 30 Damp location rating (interior applications only) Performance Nominal lumen outputs: 700, 1000 and 1300 lumens Optics: 40 CRI values: 80+, 95+, Radiant 80+ or Radiant 95+ Lumen maintenance: L70 @ 90,000 hrs [25 C] Operating temperatures: -20 C to 40 C (-4F to 104F) Electrical Input voltage:120 or 277V, consult factory for 347V Control options: non-dimming, 0-10 volt dimming, DALI dimming or Lumentalk dimming 355 rotate 30 tilt Performance summary Based on Medium (40 ), 3000K, CRI 80+ insulated ceiling non-insulated ceiling Nominal output [lm] Delivered output [lm] [W] Efficacy [lm/w] ** [W] Efficacy [lm/w] 700 528 7 75 9 59 1000 755 10 75 12 63 1300* 1 14 70 16 61 *Photometric performance is measured in compliance with IESNA LM-79-08. **Add 3 watts per fixture when specifying Lumentalk. 4 9 [116mm] Medium (40 ) SIDE VIEW 3 1 8 " [80mm] 3 1 8 " [80mm] BOTTOM VIEW Cutout: Ø 2 15/16" [75mm] Maximum ceiling thickness: 1" [25mm] * Fixed tilt construction is factory set and cannot be adjusted in the field. 1/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

PHOTOMETRIC INFORMATION Medium (40 ), all color temperatures Non-insulated ceiling installation types (RM and NC) 1,2 Nominal output [lm] [W] Delivered output [lm] Candlepower distribution Illuminance cone 700 1000 CR80 9 12 CR95 11 15 528 755 311 622 932 Center Beam Illuminance 14fc [145 lx] 9fc [93 lx] Beam Diameter 7.8 [2.4m] 9.7 [3.0m] Height 8 [2.5m] 10 [3m] 1300* 16 20 1 1243 6fc [65 lx] 11.6 [3.5m] 12 [4m] 1 Remove 2 watts per fi xture when specifying new construction insulated ceiling installation types (IC and CP). 2 Add 3 watts per fi xture when specifying Lumentalk. *Photometric performance is measured in compliance with IESNA LM-79-08. Delivered wattage and delivered output: +/- 10% tolerance. 2/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

PHOTOMETRIC INFORMATION - continued Color Rendering options comparison, 3000K Color sample Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 CRI 80+ CRI 95+ 81 80 85 99 89 81 78 80 97 86 66 16 96 64 99 79 58 88 81 93 75 Radiant CRI 80+ 81 81 86 89 81 80 80 85 68 16 66 80 62 82 93 77 Radiant CRI 95+ 95 99 97 96 96 95 94 90 97 95 97 CONTROL OPTIONS Dimming down to 1% 0-10V dimming DA1-0-10V dimming, 1% linear DA2-0-10V dimming, 1% logarithmic Dimming down to 0.1% DALI dimming DALI1 - DALI dimming, 0.1% linear DALI2 - DALI dimming, 0.1% logarithmic Professional dimming down to 0.1% 0-10V dimming PDA1 - Professional 0-10V dimming, 0.1% linear PDA2 - Professional 0-10V dimming, 0.1% logarithmic Lumentalk dimming LT - Lumentalk dimming, 1% minimum dimming value Brightness % Linear Curve Voltage % Brightness % Logarithmic curve Voltage % 3/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

INSTALLATION TYPES Minimum Ceiling Height Requirements Remodel (RM) New Construction (NC) Up to 1000lm (CRI 80) On/Off = 8" Dimming = 10" On/Off = 8" Dimming = 10" 1300lm (CRI 80) 1000lm (CRI 95) On/Off = 8" Dimming = 10" On/Off = 8" Dimming = 10" 2000lm Insulation Contact (IC/CP) 7" 9" 3000lm 8 13 2 9 [224mm] [65mm] 2 9 [65mm] 12" [305mm] 2x Ø7/8" [22mm] 7 " 1 13 [178mm] [47mm] 2x Ø7/8" [22mm] 1 13 [47mm] 10 3 [224mm] SIDE VIEW SIDE VIEW LADN-MTG-A-VOLTAGE-OUTPUT-COLOR RENDERING-NO-RM Remodel non-insulated ceiling - on/off control LADN-MTG-A-VOLTAGE-OUTPUT-COLOR RENDERING-DIMG-RM Remodel non-insulated ceiling - dimming 8 13 2 9 [224mm] [65mm] 2 9 [65mm] 12" [305mm] DRIVER BOX-NO DRIVER BOX-DIMG 14 1 4 " 25 1 2 " 14 1 4 " 25 1 2 " [362mm] [650mm] [362mm] [650mm] 12 7 [316mm] 3 1 2 " [90mm] 12 7 [316mm] 3 1 2 " [90mm] 2x Ø7/8" [22mm] 4 7 8 " [124mm] 9 3 8 " [239mm] 4 5 [109mm] 5" 6 1 2 " 2x Ø7/8" [22mm] 4 7 8 " [124mm] 9 3 8 " [239mm] 4 5 [109mm] 5" 6 1 2 " [125mm] [162mm] [125mm] [162mm] LADN-MTG-A-VOLTAGE-OUTPUT-COLOR RENDERING-NO-NC New construction non-insulated ceiling - on/off control LADN-MTG-A-VOLTAGE-OUTPUT-COLOR RENDERING-DIMG-NC New construction non-insulated ceiling - dimming 4/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

INSTALLATION TYPES - continued 14 3 [360mm] 14 1 4 " [362mm] 25 1 2 " [650mm] 2x Ø1-1/8, 3x Ø7/8, 1x Ø5/8 4 9 [116mm] 17 9 [447mm] 14 1 4 " [362mm] 25 1 2 " [650mm] 2x Ø1-1/8, 3x Ø7/8, 1x Ø5/8 6 5 [160mm] 4 5 6 1 [154mm] 9 3 8 " [239mm] [109mm] 12 15 [328mm] 6 13 [173mm] 5" 6 1 2 " [125mm] [162mm] 8 7 [215mm] 5" 6 1 2 " [125mm] [162mm] LADN-MTG-A-VOLTAGE-OUTPUT-COLOR RENDERING-CONTROL-IC/CP* New construction insulated ceiling New construction insulated ceiling, Chicago plenum rated option, airtight *Available for the following output and color rendering combinations: LADN-MTG-A-VOLTAGE-OUTPUT-COLOR RENDERING-CONTROL-IC/CP* New construction insulated ceiling New construction insulated ceiling, Chicago plenum rated option, airtight *Available for the following output and color rendering combinations: Nominal output [lm] CR80 Color rendering CR95 RCR80 RCR95 Nominal output [lm] CR80 Color rendering CR95 RCR80 RCR95 L07 L10 L10 L13 5/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

WIRING DETAILS RM: remodel non-insulated ceiling and NC: new construction non-insulated ceiling No Control Conduit fitting Conduit Locknut Ground (green) Thermal protector Input Optional Output Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2) Conduit fitting Conduit Locknut Ground (green) Thermal protector Input Data Input from Control System Data - (gray) Data + (purple) Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2) Conduit Output to next luminaire Input Duplex connector Ground (green) Thermal protector Data Output to next luminaire Data Input from Control System Locknut Data - (gray) Data + (purple) 6/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

WIRING DETAILS - continued RM: remodel non-insulated ceiling Lumentalk dimming available up to 1000 Lumens (CR80, RCR80, CR95 or RCR95), 1300 Lumens (CR80 or RCR80) Control (LT) Conduit fitting Conduit Locknut Ground (green) Thermal protector Input Control (Daisy Chain Layout) (LT) Conduit fitting Conduit Locknut Ground (green) Thermal protector Input Output to next luminaire 7/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

WIRING DETAILS - continued IC/CP: new construction insulated ceiling Insulated ceiling up to 1000 Lumens (CR80, RCR80, CR95 or RCR95), 1300 Lumens (CR80 or RC80) No Control Locknut Conduit fitting Conduit Ground (copper) Input Optional Output Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2) Locknut Conduit fitting Conduit Input Ground (copper) Data Input from Control System Data - (gray) Data + (purple) Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2) Locknut Duplex connector Conduit Output (to next luminaire) Input Ground (copper) Data Input from Control System Data Output (to next luminaire) Data - (gray) Data + (purple) 8/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

OPTICAL ACCESSORIES Maximum one accessory per fixture. The softening glass lens will be replaced by any other specified accessory. HL - Honeycomb louver RS - Linear spread glass lens CL - Clear glass lens RS - LINEAR SPREAD GLASS LENS ORIENTATION Factory installed BOTTOM VIEW BOTTOM VIEW RS Horizontal Beam Distribution Not adjustable onsite RS Vertical Beam Distribution Not adjustable onsite Install fixture onsite according to desired beam pattern direction. 9/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.

HOW TO ORDER LADN-TILT A M RD 1 2 3 4 5 6 7 8 9 10 11 1 Region: A - Americas 2 Voltage: 120-120 volts 277-277 volts Consult factory for 347 volts. 3 Output (nominal lumens): L07-700 lumens L10-1000 lumens L13-1300 lumens 4 Color Temperature: 27K - 2700K 30K - 3000K 35K - 3500K 40K - 4000K 5 Color Rendering: CR80 - CRI 80+ CR95 - CRI 95+ RCR80 - Radiant CRI 80+* RCR95 - Radiant CRI 95+* 6 Optics: *Radiant CRI options available for 3000K only. M - Medium distribution 40 o 7 Trim Shape: RD - Round shape 8 Trim Finish: WH - White trim BK - Black trim GRY - Gray trim CC - Custom (please specify RAL color) 9 Control: NO - On/Off control DA1-0-10V dimming, 1% linear DA2-0-10V dimming, 1% logarithmic PDA1 - Pro 0-10V dimming, 0.1% linear PDA2 - Pro 0-10V dimming, 0.1% logarithmic DALI1 - DALI dimming, 0.1% linear DALI2 - DALI dimming, 0.1% logarithmic LT - Lumentalk dimming* *1% minimum dimming value. Lumentalk dimming available for RM installation type only. Lumentalk dimming available up to 1000 Lumens (CR80, RCR80, CR95 or RCR95), 1300 Lumens (CR80 or RCR80). 10 Installation Type: RM - Remodel non-insulated ceiling NC - New construction non-insulated ceiling IC - New construction insulated ceiling* CP - New construction insulated ceiling, Chicago plenum rated option, airtight* *Insulated ceiling up to 1000 Lumens (CR80, RCR80, CR95 or RCR95), 1300 Lumens (CR80 or RCR80). 11 Accessories (factory installed): NA - No accessory (softening glass lens by default) HL - Honeycomb louver* RS - Linear spread glass lens** CL - Clear glass lens* *Maximum one accessory per fixture. The softening glass lens will be replaced by any other specified accessory. **Refer to page 9 for orientation guidelines. Maximum one accessory per fixture. The softening glass lens will be replaced by any other specified accessory. 10/10 Copyright Lumenpulse 2016 1.877.937.3003 5-year limited warranty.