Chlorine gas leak detector

Similar documents
Danfoss gas detection units

Stand Alone DYNAGARD SP Operation Manual

Oxygen (O2) Single-Point Gas Detection System

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Two-Channel Gas Controller

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Danfoss gas detection unit Type GD Heavy Duty

GLD-30 Gas Leak Detector

Universal Gas Detector

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Danfoss gas detection units

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Carbon Monoxide Transmitter

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Multi-Gas-Controller MGC2

Operations Manual TS400. Test Station for G450/G460 Gas Detector

ZSC100 Gas Detection and Alarm System Controller

BST-MG01 Single Gas Detecting Alarm Manual Instruction

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

XP95/Series 90 Test Set

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

Air Check O 2 Deficiency Monitor 0-25%

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Oxygen Monitor Operating Manual

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Beacon 110 Gas Monitor Operator s Manual

Inductive Conductivity

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

MultiFix Central unit

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Air Check O 2 Sample Draw Monitor

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

HIGH CAPACITY PRODUCT LINE

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

gas monitoring system

PolyGard 2-channel Gas Controller MGC-03

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

Model Q45P/R. ph/orp Monitor...

Air Check O 2 Deficiency Monitor

Combustible Gas Detection and Control System

Air Check O 2 Deficiency Monitor 0-25%

Air Check O 2 Remote Monitor 25%

AS950 REFRIGERATED SAMPLERS

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Dräger Polytron 8000 Stationary gas detector (EC)

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

P R O D U C T D ATA S H E E T

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Model Q45P/R. ph/orp Monitor...

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

IGD.CO.UK

FCHM Hydromatic Pump Control Module

MP920 SALT CHLORINATOR

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Free Chlorine Measuring System

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

REPEATER FS5200R OPERATION MANUAL

P R O D U C T D ATA S H E E T

Fire control panels FC360

HIGH CAPACITY PRODUCT LINE

Floor heating controls, wire connection 1

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ST Wiring diagram. Product description. Standard temperature controller. Order number

ETO 2 - Controller for ice and snow melting

testo 316-EX gas leak detector Instruction manual

AS950 PORTABLE SAMPLERS

Air Check O 2 Sample Draw Monitor

REPEATER FS5200R INSTRUCTION MANUAL

M2 Rig Monitor Operator s Manual

HYGROPHIL H process hygrometer

5, SE GÅNGHESTER,

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

FX FIRE DETECTION SYSTEM

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Transcription:

INSTRUCTION MANUAL FOR Chlorine gas leak detector with battery back up series M 4510 C 2007 Controlmatik ABW d.o.o.

1

CONTENT 1.0 General description:... 3 2.0 The Unit... 4 3.0 Controls and Displays... 6 3.1 Start up... 9 4.0 Set the limits for alarms... 10 5.0 Test functions... 11 6.0 During operation... 12 7.0 Reset the alarm relay outputs... 13 8.0 The Sensor... 14 9.0 Connection scheme... 16 10.0 Technical data... 18 2

1.0 General description: The M 4510 C series Controlmatik ABW leek detector is assembled as unit with display, two adjustable alarms and unit fault alarm, power supply module, battery back up and separate detection cell - probe. The detection cell is mounted in IP 65 housing and features 4-20 ma output which is connected to the signal evaluation unit. Two adjustable alarms can be set and following units can be activated in case of chlorine gas leak: - Alarm horn - Flashing light - Ventilation system - Neutralisation system For detection cell see product information for Chlorine Gas measuring sensor M 2103 C. Typical use of chlorine gas leek detector 3

2.0 The Unit The unit consists of: POWER SUPPLY MODULE SIGNAL EVALUATION MODULE IP 65 HOUSING The signal gas measuring sensor probe M 2103 C (2) is connected to the signal evaluation unit with display (1). The signal evaluation unit evaluates the signal and displays the value in PPM. 4

2.1 Principle of the system The unit amplifies the current input signal from gas measuring sensor M 2103 C proportional to the gas concentration in the room air. Chlorine gas leak detection unit M 4510: Amplifies the current from gas measuring sensor M 2103 Actuate the warning system when the set limit is exceeded Outputs the measured concentration of both sensors as a signal of 4-20 ma via two current outputs Display mode: When unit is switch ON it automatically starts with display mode in this mode you can: Set mode Indicate the actual measured values Indicate error messages Set the parameters for two adjustable set point alarms Check all test functions Menu mode(only for certificated Controlmatik ABW service) Set all parameters which are important for the normal operation of the device 5

3.0 Controls and Displays 1 Chlorine gas leak detector M 4510 C 2 + - 3 OK 4 5 9 8 7 6 Short preview of display and control keys! 1- LC display Display is 12 characters and 4 lines In the display mode, it shows actual measured values In the menu mode, it shows adjustable parameters 2 - key Turning OFF the relay outputs 4 and 5. In combination with key give us access to controller menu. This menu is use only for certificated Controlmatik ABW service! 6

3 key Showing the status of sensor relay outputs 1,3 and 4 In combination with key, the real time and status of all inputs and outputs are displayed 4- key Showing the status of sensor relay outputs 2,4 and 5 In combination with key, the real time and status of all inputs and outputs are displayed 5- key In combination with or key scrolling to all alarm (ALM1SENS1, ALM1SENS2, ALM2SENS1, ALM2SENS2) parameters set up. In combination with key give us access to controller menu. This menu is use only for certificated Controlmatik ABW service! 6- key In combination with up key give scrolling for alarm parameters set 7

7- key Decreasing the alarm parameters In combination with, testing the relay outputs 8- key Increasing the alarm parameters In combination with, testing the relay outputs 9- key In combination with up In combination with parameters set up key give scrolling for alarm parameters set key give access and scrolling for alarm 8

3.1 Start up When the device is turned ON there are several options of display appearence: Sensors are not connected! When device is turned ON and all sensor inputs are disconnected then the left screen is appeared. I/O list Indicates which inputs/outputs are active. Output 2 is indicating if any sensor lost connection. Sensor must be connected for 5s. If connection is lost after 5s then relay 1 will be active. Both sensors are connected! When device is turned ON and all sensor inputs are connected then the left screen is appeared. It is displaying the actual value of measurement. When sensors are not properly connected! ` If sensors inputs are connected and signal is between 1.0mA and 3.6mA then the left screen is appeared. This can appear in case that: - Connected sensor is not working properly - Connected sensor has 0-20mA output instead of 4-20mA Only one sensor is connected! If only one sensor is connected then ERROR sign from the other sensor is not appeared 9

4.0 Set the limits for alarms Two different alarms to set up. Alarms A1 and A2 have minimum set point at 2ppm. Factory setting for all alarms are at 5ppm. Set the limits for sensor: Press and together to enter the alarm limit, set up menu Set alarm limit to desired by pressing and key (from 2ppm to 20ppm). Factory settings are set at 5ppm, to jump on minimum value 2ppm press. Confirm and moving to the next alarm limit set up by pushing down and pressing key With above described procedure, accessing set up for all 4. alarms To exit the alarm limit set up menu push key. Returns back to display mode menu 10

5.0 Test functions The Chlorine gas leak detector M 4510 C has 5 relay outputs. Output 2 is actuated whwn one of the sensors has lost connection or membrane of sensor is damaged. Outputs 3 and 4 are indication from alarm1 (A1) and alarm2 (A2) for sensor 1. Outputs 5 and 6 are indication from alarm1 (A1) and alarm2 (A2) from sensor 2. Each active output (3, 4, 5, 6) is indication for an working alarm. On detector control panel is possibility to check all relay outputs, meanwhile also testing the connected warning and protection devices. While testing relay outputs, the connected warning and protection device will also be activated! Checking the relay sensors outputs While in display mode menu push and key together for 3s. All relay outputs (from 1-6) will be activated for 10s. To check the activated relay outputs press and together To check activated relay outputs for sensor 1 press To check activated relay outputs for sensor 2 press 11

6.0 During operation In the display mode you can always read the actual measured values. If one sensor is connected If two sensors are connected Read error messages. If more than one error message is present, they are displayed one after the other. One sensor is working properly and one is in error, they are displayed one after the other. 12

7.0 Reset the alarm relay outputs RESET the alarm relay outputs Relay output 2 is actuated when one of the sensors has lost the connection or membrane is damaged. It can only be reseted with key. When value of gas chlorine sensor in air, reach or overreach the stored value, relay outputs are actuated after 5s. After the value of gas chlorine SENSOR in air drops under 1.5ppm the ALARM relays, OUTPUT 3 at SENSOR 1 and OUTPUT 5 at SENSOR 2, are RESETED.. The relays, OUTPUT 4 at SENSOR 1 and relay OUTPUT 6 at SENSOR 2 can only be rested by pressing key. After reset, the relays will not be actuated again unless the value drops under set point value and rise again to set point value. Controlmatik ABW recommends to connect the neutralisation or sprinkling system to alarm relay OUTPUT 3 at SENSOR 1 or OUTPUT 5 at SENSOR 2. Signal horn alarm and sound alarm are recommended to connect on OUTPUT 4 at SENSOR 1 and relay OUTPUT 6 at SENSOR 2 13

8.0 The Sensor 7.1 General description and technical info The sensor and electronics are closed in a sealed casing resistant to aggressive gases and liquids. The sensor operates on the basis of a chemical cell and a diffuse capillary membrane, which has plenty of advantages: - chemical additives are not necessary - the hydrochloric acid concentrate based in chemical cell is regenerating during the chemical reaction, as well free oxygen is being released - concentration of gas and signal are being proportional - very stable measurement in a long period of time - a long duration period (2 years on air ) - minimal maintenance costs - temperature range : -20 -+55 - repeatability :2 - working area of pressure (mbar):900-1100 - working area of relative dampness continuance(%):15-90 - working area of relative dampness-momentarily(%):0-99 Supply and transmission of the signal are flowing through shielded cable. The probe can be a part of chlorine gas in the air leek detector series M 4503 C or can be connected to the Aquaprocesor series M 5600 or directly on PLC. - supply voltage :+12V..24V DC - current output :4-20 ma - measurement loop resistance :500Ohm Gas in the air is measured in units (in 1m3 of air=1cm3 of chlorine=1ppm), those can be shown on the unit f of the leek detector series M 4510 C. Sensor of Cl 2 in the air has two years of lifetime on air. Lifetime of two years can be achieved if the sensor is placed where the moisture is relatively normal and the sensor is not constantly exposed to the high concentrations of Cl 2. Sensor sensitivity should be checked once per year. For simple sensitivity check, powdered chlorine can be used. Take a (100ml) plastic bottle than pour 50 ml of powdered chlorine in and as well so many drops of water until chlorine gets wet. Close the plastic bottle and shake it well. After one hour, open the bottle and put it under the sensor. The gas that comes out of the bottle should raise the sensor to the maximal value (20ppm) in couple of seconds. If the bottle is removed for 2-3 cm from the sensor, the concentration will be lower and the sensor will rise only for 4-5 PPM. At 14

lower concentration we can notice if the sensor is still sensitive. If we don t get any sensing, we have to change the sensor. The lifetime of the sensor can be shorter than two years if mayor leak occurs and if the sensor is damaged because of omission of the whole cylinder or container of chlorine. 7.2 Installation The probe includes one wall mounting holder and screws with wall insertion pieces. The probe must be mounted 50 70 cm from the ground. If only one probe is used in the chlorine gas storage room than it must be mounted near the gas source for rapid gas detection. 15

9.0 Connection scheme WARNING Disconnect power supply before connecting the sensors and relay contacts Due to safety reasons, the PE cable must be connected correctly Before connecting power supply: Check power supply from technical data is correspondent to local supply Protect the cable connections and plugs from corrosion and moisture Relay outputs connections depend on the type of warning and protection systems! Power supply connection Connect power supply to left terminal: PE, N, L1 Gas sensor 1 Connect to terminal 14 and 17 Gas sensor Connect to terminal 16 an 18 16

10.0 Installation and mounting The IP 65 protections is only guaranteed with the transparent cover closed and with appropriate cable glands or dummy caps. To obtain IP 65 also protect the cable connection and plugs from corrosion and moisture While wall mounting do not damage the gasket to obtain IP 65 Take off the cap cover Fix the device with screws Remount the clamp cover to obtain the IP65 17

11.0 Technical data Technical data M 4510 C: Probe unit ( M 2103): For data see M 2103 documentation Detector unit ( M 4510 C): Measuring unit PPM Temperature range from - 10 to + 50 C Resolution at 20 C 0,1 PPM Repeatability 2% Measuring range 0-10 PPM or 0-20PPM Supply voltage : 220V, 50/60Hz Fuse : 125 ma Analogue output: 2 x 4-20 ma Output voltages : 0-10 V DC Current input : 2 x 4-20 ma for sensor 1 and sensor 2 Consumption : approx. 4 VA Response time: T(80%) <90 sec Recovery time: T(5%) <90 sec Battery backup (B) : 8 hours Measuring loop resistance : 740Ohm Display : LCD 4 lines, 12 characters Relay output : 4 relay output; max: 250V/8A Weight: M 4510: approx. 2.5 kg M 2103: 0,5 kg Housing protection type: IP 65 Technical data is subject to change without notice! 18