Voice Alarm system integration

Similar documents
Call stations and extensions

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Entero Voice Alarm system.

VACIE REFERENCE GUIDE REVISION 1.2.6

SOHO X. 4" Two-way passive system

N-8000 SERIES IP INTERCOM SYSTEM

Vocia VACIE. Reference Guide

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

LORAIN CIP 4890/48120 DC Power System

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Entero Voice Alarm system. User guide

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

IF-L/RF Protection Switch

FLOW CONTROLLER TYPE S/601

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

16 Zone Voice Evacuation VA & PA Sound System

M2500 Engine Controller Installation Manual

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

PUBLIC ADDRESS SYSTEM

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

VPS3 Installation Manual

i.net Engineered system solutions for

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

TABLE OF CONTENTS. HEADQUARTERS Severo Ochoa, Málaga, Spain Tel / Fax

QS941A Controller User Interface

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

EasyTronic III MANUAL SERVICE

IntesisBox BACnet/IP Server - Notifier ID3000 series

RAy SNMP. Application notes.

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

ECO N DATE DESCRIPTION OF CHANGE CHG

_5120_School_Intercom_Rack_Spec.doc 09/21/04

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

5120_School_Intercom_Rack_Spec.doc 10/10/07

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Careline Anna Careline GSM

E3 Series Broadband System

E3 Series Broadband System

D 8A / D 10A / D 12A / D 15A D 12A SUB / D 15A SUB

LORAIN CSP DC Power System

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

Alarm Tone Generator Model AG17

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Surface Mount Wall Speaker with InformaCast

R11B EN. Operating Manual English. RackCDU (InRackCDU) Operating Manual. History: Date: Notes: Revision: 21-Dec First Release 1.

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

ENGLISH. Technical Specifications. Version 1.1 February 2003 EUROPOWER PMX2000

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Panel Mounted Fault Annunciator Series

Installation and Operation Manual

SIMATRIX NEO Modular Video Matrix

Analog Input Module IC670ALG630

SOUND SYSTEMS NEW PRODUCTS

ENGLISH. Technical Specifications. Version 1.6 April 2007 EUROPOWER PMH2000

FCCP 200: Fume-cupboard indicator and monitor

Dry Contact Probe DCP (#30008)

S/601 Controller Installation Manual

Public Address Project Combisound System

SIP Alerter. Each SIP Alerter also has an onboard relay, enabling centralized control of a classroom door lock for emergency lockdown scenarios.

ModBus DE-1 INSTALLATION AND USER MANUAL

OVEN INDUSTRIES, INC.

Combined CAN Sensor Unit Temperature, Humidity and Smoke

INTEGRITY VOICE ALARM ROUTING MATRIX

NEO IP/GSM Technical Handbook

AXIS SNMP MIB. User Manual

FS Mircom FX2000 Fire Alarm Panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Introduction Thank you for purchasing Pure Acoustics products, and welcome to the Pure Acoustics family of satisfied customers!

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

ECC-50/100C. Emergency Command Center

The Next Generation of Dynamo Subwoofer Systems

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

EC-P Zone Intruder Alarm System

Figure 1. Figure 2. See notes 1 and 2 below.

Instructions manual. By-alarm. By-alarm Manager software

RAEGuard 2 PID. User Guide

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

English. Doro CareIP Mobile. User Guide

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

PowerLogic Branch Circuit Power Meter (BCPM)

Lift Station Level Controller

INSTALLATION INSTRUCTIONS

SOUND SYSTEMS NEW PRODUCTS

EC3-X33 Stand-alone Superheat Controller Technical Data

Fratech Multipath-IP

tyco PAVA IP Audio Voice Alarm Router tyco PAVA Systems Features : K ƉƟŽŶĂůD ŽĚƵůĞƐ

HR MPC (PDV 25%) O5/2014

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

DTSX200 Communications(Modbus) Guide

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)

New Product. Addendum

Experts in PA/VA Systems

Quickheat 30 weather compensated boiler control

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Transcription:

Voice Alarm system integration technical bulletin - version 3.0 Overview of and features for integration with Voice Alarm systems General layout Comprehensive monitoring for integration of an L-Acoustics system with a Voice Alarm system requires: a third-party Central Control Unit (CCU, e.g. Crestron, Extron, etc.) supporting the L-Acoustics L-COM protocol, or SNMP on-site calibration of nominal system conditions and failure state conditions General layout Crestron is a trademark or registered trademark of Crestron Electronics, Inc. in the United States, other countries or both. Extron is a registered trademark of Extron Elctronics. 1 Voice Alarm system integration technical bulletin (en) version 3.0

Overview of and features for integration with Voice Alarm systems System monitoring System monitoring provided by and ampli ed controllers. function Real-time load presence and short-circuit detection on output channel Yes* Yes* Periodic silent test of output circuit Yes Yes AES/EBU input signal presence and error detection Yes Yes Pilot tone detection on active inputs Yes Yes Power ampli er failure detection Yes Yes Power supply failure detection Ext** Yes * on condition that output delivers at least 1 W / 4 Ω ** to be periodically tested by Central Control Unit Ethernet control network Ethernet control network for and ampli ed controllers. type of network ethernet ports cabling Local Area Network with up to 253 ampli ed controllers two, up to 1 Gb/s CAT5e cable (or higher), max length = 100 m *, RJ45 connectors * Typical. May be extended using third-party ber optic interfaces. Power statuses and cascaded links Consequences of power statuses on cascaded links. ampli ed controller link powered on and idle standby powered off power cord removed ethernet refreshed refreshed refreshed* interrupted AES/EBU refreshed ok ok ok analog ok ok ok ok ethernet refreshed refreshed refreshed* interrupted AES/EBU refreshed ok ok ok analog ok ok ok ok * powered off or does not use any IP address and cannot be controlled remotely Voice Alarm system integration technical bulletin (en) version 3.0 2

Overview of and features for integration with Voice Alarm systems Signal inputs Signal inputs of and ampli ed controllers. analog audio inputs 4 balanced analog inputs line level up to +22 dbu 4 female XLR connectors 4 male XLR for passive link digital audio inputs simultaneously active inputs input mixing analog cabling digital cabling 2 AES/EBU input (110 Ω) 2 female XLR, shared with analog inputs 1 and 3 2 male XLR for active link with failover relay, shared with analog links 1 and 3 up to 4, analog or digital, selection by pair yes: by pair, sum or difference of the channels of the active inputs recommended maximum length: up to 100 m (typical) recommended maximum number of cascaded links: 22 tested max. length: 305m (at Fs = 48 khz) with selected AES/EBU rated cables recommended maximum number of cascaded links: 22 Automatic fallback The AES/EBU automatic fallback feature allows for input signal redundancy where AES/EBU is used as primary signal. In case of error, the input mode instantaneously switches over to the fallback input (less than 135 ms of audio interruption). automatic fallback mode (built-in) AES/EBU to analog AES/EBU to AES/EBU Alternative modes where analog is used as a primary signal may be implemented by integrators based on pilot tone detection and input selection management by Central Control Unit: programmable fallback mode (managed by CCU) analog to AES/EBU analog to analog Status change time OFF to ON 5 s 9 s STANDBY to ON 5 s 5 s ON to STANDBY < 0.5 s < 0.5 s ON to OFF < 0.5 s < 0.5 s 3 Voice Alarm system integration technical bulletin (en) version 3.0

Overview of and features for integration with Voice Alarm systems Power and UPS sizing This table presents the power consumption for each ampli ed controller for a typical musical program in nominal conditions, in idle mode, and in standby mode, for various nominal loads. The calculator is available at www.l-acoustics.com/installation-calculation-tools-137.html. amp 4 ch. loaded at 1/8 max power (-9dB) idle standby load (BTU/hr) 4 or 8 Ω 3 250 853 0.3 60 0.1 10 2.7 Ω 11.5 750 2559 1 160 0.6 10 4 Ω 8.1 550 1877 1 160 0.6 10 8 Ω 4.8 350 1194 1 160 0.6 10 Third-party control systems Functions available from third-party control systems using L-COM protocol or SNMP. status information and monitoring (read only) ampli ed type operating mode: standby, active full reporting of errors input mode and status, fallback status preset name, family, output names name of next available preset signal level / limit / clip front panel keys locked/unlocked commands (write) standby / wake-up input mode selection preset load mute/unmute, output gain control lock/unlock front panel keys output gain Settings protection In order to ensure the integrity of a re alarm system, access to the ampli ed controllers parameters has to be restricted. These parameters can be protected independently from: LA Network Manager and ampli ed controller front panel access third-party control system application using a speci cally determined access policy Settings Protection is based on three levels of users. When Settings Protection is enabled by the Administrator: only the Administrator can load non-authorized Session les delete a user preset reset Units to factory default parameters update rmware use quick access to gain from front panel the Advanced User can (with the PIN code) load a factory preset store a preset modify any group parameter modify a preset parameter modify the IP address of a Unit the General User can load authorized Session les restore Session load user presets select the input mode mute/solo set in standby / wake-up Access rights have been de ned by L-Acoustics to meet the needs of 90% of the xed installation applications. This policy cannot be modi ed by the Administrator. For any speci c need please contact L-Acoustics Application Team (applications@l-acoustics.com). Voice Alarm system integration technical bulletin (en) version 3.0 4

Appendix Appendix Rear connection panels The ampli ed controller's rear side features three panels for audio and network cabling: a speaker panel (1) to connect the loudspeakers a signal panel (2) to connect the analog and/or digital (AES/EBU or S/PDIF) audio sources and link the signals to another ampli ed controller an L-NET panel (3) to connect to a network and be remotely controlled by LA Network Manager audio and network connection panels 1 2 3 audio and network connection panels 1 2 3 5 Voice Alarm system integration technical bulletin (en) version 3.0