ATC32U01 Basic Operation Guide Communicating Programmable Thermostat Display 1 Date 2 Outdoor Temperature (Optional) 3 Current Humidity Level 4 Indoor Temperature 5 Time 6 Fan Mode 7 Operating Mode Off, Cool, Heat, Emergency Heat 8 Temperature Setpoints 9 User Options 1 5 2 6 3 4 7 { 8 9
Select Mode From the main menu select Mode Select one of the following: - Turns unit off - Automatically cool or heat based on setpoint COOL - Cool down to the cool setpoint temperature HEAT - Heat up to the heat setpoint temperature EMERGENCY HEAT - Turn on backup heating source to heat up to heat setpoint temperature (optional) HUMID ON RH 41% SETPOINT HEAT 62 COOL 82 RH TEMP MENU OPERATING MENU COOL HEAT EMERGENCY HEAT CHANGE Change Temperature Setpoints Use left-right arrow keys to select TEMP Use left-right arrow keys to select HEAT or COOL Once selected, use up-down arrow keys to change temperature setpoint (desired temperature) 10/13/11 8:25 AM HUMID ON RH 41% 68 RH SETPOINT HEAT 62 COOL 82 TEMP MENU THIS TEMPERATURE UNTIL 5:00 PM HEAT 70 CHANGE COOL 74 SET TEMP 1
Select Fan Mode Select Humidity Level Use left-right arrow keys to select RH 40% Use left-right arrow keys to select RH 10/12/11 5:22 PM HUMID ON RH 38% 70 SETPOINT HEAT 70 COOL 78 Select one of the following: - Runs when the unit is heating/cooling CONTINUOUS ON - Runs all the time, regardless if it is heating/ cooling MED - Follows daily/ weekly schedule (see section on daily/weekly schedule) RH TEMP MENU MENU CONTINUOUS ON MED HEAT Select on of the following: HUMIDITY SETTING - Desired humidity when trying to humidify the space (in heating mode, for example) DEHUMID SETTING (OPTIONAL) - Desired humidity when trying to remove humidity from the space (in cooling mode, for example) RH TEMP MENU HUMIDITY CONTROL 42 % HUMIDITY HUMIDITY SETTING 40% DEHUMID SETTING 60% 2
Program Daily/Weekly Schedule Use left-right arrow keys to select MENU RH 40% Use left-right arrow keys to select setpoints for cooling & heating You can also select if you want the unitʼs fan to run while heating/cooling, or continuous during that period WAKE HEAT COOL 6:00 A 70 78 LEAVE 8:00A 62 82 RETURN 5:00P 70 78 SLEEP 10:00P 62 82 Use up-down arrow keys to select Use up-down arrow keys to select DAY RH TEMP MENU MENU COPY TUESDAY WEDNESDAY THURSDAY SATURDAY FRIDAY EVERY DAY SUNDAY WEEKDAYS WEEKENDS Select COPY to copy program from one day to another Use up-down arrow keys to select day to copy FROM Use up-down arrow keys to select day/group of days to copy to MENU COPY TUESDAY WEDNESDAY THURSDAY SATURDAY FRIDAY EVERY DAY SUNDAY WEEKDAYS WEEKENDS COPY TO WHICH DAY? WEDNESDAY FRIDAY SUNDAY WEEKDAYS TUESDAY THURSDAY SATURDAY EVERY DAY WEEKENDS 3
Main Menu Use left-right arrow keys to select MENU RH 40% - See document 97B0055N02 for more details Select one of the following: RH TEMP MENU - TEMP ADJUST ONLY - Set pass code to lockout any changes EXCEPT changing temperature setpoints - TOTAL KEYPAD LOCKOUT - Set pass code to lock out ANY changes - Over ride daily/weekly schedule - VACATION - Set hold temperatures till certain day/time - PERMANENT - Set hold temperatures till cancelled - CANCEL - Select CANCEL OVERRIDE on main screen TEMP ADJUST ONLY TOTAL KEYPAD LOCKOUT 4
Change Filter Choose CANCEL ALARM once the filter is changed CHANGE AIR FILTER RH 28% CANCEL RH ALARM MENU Service Needed Press any button for more information SERVICE NEEDED PRESS ANY BUTTON FOR MORE INFORMATION The next screen will display the model and serial number of your ClimateMaster unit, the phone number of your installing contractor, and the fault code and a description of the fault that triggered the Service Needed screen SERVICE NEEDED PHONE CONTRACTOR BRAND NAME L NUMBER SERIAL NUMBER E7 =OVER/UNDER VOLTAG 5
7300 S.W. 44th Street Oklahoma City, OK 73179 Phone: 405-745-6000 Fax: 405-745-6058 climatemaster.com ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster s Customer Service Department at 1-405-745-6000 for specific information on the current design and spec i fi ca tions. Statements and other in for ma tion contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster s opinion or com men da tion of its products. The management system governing the manufacture of ClimateMaster s products is ISO 9001:2000 certified. The USGBC Member Logo is a trademark owned by the U.S. Green Building Council and is used by permission. The logo signifies only that ClimateMaster, Inc. is a USGBC member; USGBC does not review, certify, or endorse the products or services offered by its members. We are a proud supporter of the Geothermal Exchange Organization - GEO. For more information visit geoexchange.org ClimateMaster is a company of LSB Industries, New York Stock Exchange Symbol: LXU 97B0055N04 ClimateMaster, Inc. 2011 Created: 12/9/11 geoexchange.org ISO 9001:2000 Certified Quality: First & Always