UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912

Similar documents
CEILING FAN OWNER'S MANUAL

Dioluce Products Installation Instructions

Bathroom Exhaust Fan/Fluorescent Light Combination

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

1 x4 Dimmable LED RetroFits

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

LED Flat Panel Retrofit

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

GLED INSTALLATION INSTRUCTIONS

Installation Instructions

CEILING FAN OWNER'S MANUAL

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

INSTALLATION INSTRUCTIONS

GLED INSTALLATION INSTRUCTIONS

Fillmore Small Pendant Assembly and Installation Instructions

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

Bathroom Exhaust Fan/Fluorescent Light Combination

LED IMPORTANT SAFETY INSTRUCTIONS

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

Installation Instructions

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

installation and operation manual for Hunter Ceiling Fans

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

Bedford Face Installation

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

5Make electrical connections.

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Modular Drawer Cabinets Installation Instructions

e Heater/Exhaust Fan/Light User s Guide

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Dual Function Bowl Light Kit

TRUSTY PRODUCTS, INC.

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

Innovative Lighting R-Series Vertical Refrigeration

e Bath Fan with Light User s Guide

CEILING FAN OWNER'S MANUAL

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Catalog Number. Notes

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Installation Instructions. Tersen. Ratio Canopy 1.5

Installation Instructions Labor and Delivery Exam Light Set

Lifetime Limited Warranty

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

CEILING FAN OWNER'S MANUAL

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

CEILING FAN OWNER'S MANUAL

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

Hanson LED C e i l i n g F a n

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

CONTENTS BEFORE YOU BEGIN

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

Cold Deck Canopy and Shelf Lights and Retrofit Kit

FerronTM. Instruction Manual A Kichler Decor ceiling fan

To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

KD-27A SERIES DISHWASHERS

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Ceiling Fan Installation Instructions

Burgess 54" Ceiling Fan with Remote Control Owner s Manual

ST. KITTS CEILING FAN

36"x17" Portable Tool Chest and 6-Drawer Tool Cabinet

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Owner s Guide and Installation Manual

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Solatube Daylight Dimmer Installation Instructions

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

SERVICE MANUAL. Freestanding cooker 500 and 600 / Range Gas- gas Electric CFSGSV14 CFSGWH14 CFSESV14 CFSEWH14

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

Cold Door 2 LED Retrofit Kit Lighting System

Innovative Lighting R-Series Overhead LED Conversion Kits

Oscillating Ceiling Fan

Tommy Bahama INDOOR/OUTDOOR 52 in. / 132 cm. CABRILLO COVE CEILING FAN

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

THE FLEX CEILING FAN INSTALLATION INSTRUCTIONS

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

Installation and Maintenance for FlexValue Cleanroom Ceiling Model

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Larson by Hampton Bay

Concert Breeze s Manual

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation. Leveling

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SPK-W611 Multipurpose Speakers. P/N: Rev 2

Transcription:

UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912 Drawing: 762000XX Rev: A Sheet: 1 of 8 Eng: CLD Date Drawn: 04/21/17

TYPICAL GRID CEILING RECESSED FIXTURE MOUNTING SUPPORT WIRE HOUSING SLOT #8 SCREW DETAIL A T-BAR BRACKET T-BAR HOLE A T-BAR BRACKET SHOWN BENT 90 ATTACH TO CEILING GRID HERE WITH #8 FASTENERS Remove the lens from fixture before attempting installation. Unlatch one end, swinging frame up/out approximately 45 and unhook the hinge from the housing. Refer to See Sheet 3 for instructions. Set lens aside and re-install as last step of installation. Remove electrical access cover. Note: Steps two and three can be reversed if ceiling space constraints required. Install the (4) T-bar brackets into the housing slots in each of the four corners using a #8 screw. Brackets may be bent to accommodate obstructions. If fixture is marked for orientation ( HEAD or FOOT ), be sure to align in the proper direction. Install the fixture in the T-bar grid system by lifting the fixture through the opening and lowering it onto the T-bar grid. 3. Attach support wires from each of the four T-bar brackets to the building structure. 4. If required, drill hole in the ceiling grid at the T-bar hole locations and attach the fixture to the grid with #8 fasteners. Drawing: 762000XX Rev: A Sheet: 2 of 8 Eng: CLD Date Drawn: 04/21/17

3. 4. THERMAL PROTECTOR (AS SHIPPED) HOUSING THERMAL PROTECTOR (1) OR (2) USED Latch Access Cover THERMAL PROTECTOR INSTALLATION (WHEN SUPPLIED) THERMAL PROTECTOR (INSTALLED) HOUSING The thermal protectors are shipped taped to the side of the housing to prevent damage in shipment. After installation into the T-bar grid system, remove the tape and push the thermal protector into the hole in the housing until it snaps in place. CAUTION: The thermal protectors must not contact the T-bar grid system. f the housing has two thermal protectors, install the second protector like the first. Wire the fixture per instruction on pages 3 and 4. Drawing: 762000XX Rev: A Sheet: 3 of 8 Eng: CLD Date Drawn: 04/21/17

WIRING INSTRUCTIONS FIXTURE TOP VIEW CONTROL SYSTEM INTERFACE WIRING Patient/Room Controls READING LINE EXAM LINE -NGT LINE (OPTIONAL) COM AMBIENT LINE AC Supply Patient/Room Control Interface All connections to fixture are at line voltage. Use of a separate control interface is require to control fixture by means other than line-voltage switches. All AC inputs to fixture must be supplied from the same branch circuit. LINE COM Drawing: 762000XX Rev: A Sheet: 4 of 8 Eng: CLD Date Drawn: 04/21/17

3. 4. 5. 6. Umbilical Cable (shipped pre-attached to remote fixture) Distance from fixtures to bed headwall - optimum: 12 in. maximum: 24 in. Remote Fixture Support wire attachment eyelet Bracket mounting hole T-bar mounting bracket (4 per fixture) Attach mounting bracket to T-bar flange here using #10 fasteners 1/4" washer 1/4-20 screw Master Fixture 24 in. recommended spacing between fixtures 1/4-20 nut 1/4" washer Each fixture must be surrounded by standard NEMA type G T-bar flanges/grid sytem. Flange spacing on the "long" axis of the fixtures should be 48" nominal (standard 4-foot). Flange spacing on the "short" axis of the fixtures should be 1' centerto-center. It may be necessary to modify an existing grid installation to accomodate the fixtures. Remove the lens/diffuser assembly from each fixture before attempting installation by unlatching one end. Swing frame up/out approximately 45 and un-hook hinge. Set assemblies aside and re-install as last step of installation. Install the fixtures into the grid flange system by lifting the fixtures at an angle through the opening and lowering them onto the grid flanges. Install T-bar mounting brackets to each of the four corners of each fixture with provided screws, nuts, and washers as shown. Attach fixture to T-bar grid system at all four corners using #10 fasteners (not included) through holes in mounting brackets. It may be necessary to drill a hole in the vertical web of the T-bar grid members. If required by code or weight restrictions of the ceiling grid, affix support wires from the building structure to the attachment eyelets in the mounting brackets as shown. Drawing: 762000XX Rev: A Sheet: 5 of 8 Eng: CLD Date Drawn: 04/21/17

3. 4. THERMAL PROTECTOR INSTALLATION MODELS WITH -NGT AND -BSLED OPTIONS ONLY Remote fixture AS SHIPPED Insulation detector Master fixture Insulation detector (1 or 2 provided) installed in Master fixture only. INSTALLED Thermal protectors are pre-wired to the master fixture, if required. Thermal protectors are shipped taped to the outside of the master fixture housing during shipment. After installation into the T-bar grid system, remove the tape and push the thermal protector(s) into its (their) mounting hole(s) until they snap into place. CAUTION: Thermal protectors MUST NOT rest on or otherwise contact the grid system after installation. Drawing: 762000XX Rev: A Sheet: 6 of 8 Eng: CLD Date Drawn: 04/21/17

FIXTURE WIRING REMOTE 3. 4. 5. 6. 7. 8. 9. 10. 1 UMBILICAL CABLE SEE NOTE #4 Patient/Room Controls FIXTURE TOP VIEW MASTER READING LINE EXAM LINE AMBIENT LINE AC Supply LINE Patient/Room Control Interface -NGT LINE (OPTIONAL) -BSLED LINE (OPTIONAL) COM Install the fixtures into the T-bar grid system and install thermal protector(s) (if provided) before proceeding with the following steps. Remove the wiring cover plate in the Master fixture (between the linear fluorescent and compact fluorescent lampholders) by unscrewing (4) #8 screws. Install the free end of the umbilical cable from the remote fixture into the master fixture and secure the plate with supplied nuts. Plug the connector(s) together inside the master fixture to complete the electrical circuits to the remote fixture. Make connections to line voltage per the diagram above. All connections to fixture driver are at line voltage. Use of a separate control interface, is require to control fixture by means other than line-voltage switches. All AC inputs to fixture must be supplied from the same branch circuit. After making wiring connections, re-install the wiring cover plate in the master fixture, install lamps, and re-install lens/diffuser frames that were removed before installation in the grid system. It is not recommended that optional -BSLED lighting be controllable from the patient bed, pillow speaker, or patientaccessible wall controls. Ambient line and exam line must both be energized to achieve exam light levels on patient bed surface. All electrical connections are made in the master fixture. COM Drawing: 762000XX Rev: A Sheet: 7 of 8 Eng: CLD Date Drawn: 04/21/17

INTERNAL WIRING BLOCK DIAGRAM AC Line Voltage AC Common Switching Control BLK WHT BLK WHT BLK WHT BLK WHT Reading Lamp Ballast Ambient Lamps Ballast Exam Lamps Ballast(s) NGT LED Driver (optional) Drawing: 762000XX Rev: A Sheet: 8 of 8 Eng: CLD Date Drawn: 04/21/17