Manual Isolating Barrier D461 (Revision 05)

Similar documents
Manual Isolating Barrier D461R1 (Revision 01)

Operating Manual MS220Vi and MSR220Vi

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Operating Manual MS220VA and MSR220VA

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

IECEx Certificate of Conformity

Physikalisch-Technische Bundesanstalt

A6 Safety Monitoring Device

The CE Marking Access to the European Market

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Manual Power relay SR853

Indoor/outdoor resistance thermometer Model TR60

COMPACT FLAME CONTROLLER CFC 1000

Rosemount 3490 Series

Inductive slot sensor

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

FDOOT241-A9-Ex Multisensor fire detector

4) Intrinsic Safety Certification

SEPARIX. Technical Documentation. SEPARIX-C/-T and SEPARIX-Control CT. Edition: Version: 5 Art. no.:

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Operating Manual MS220DA

OPERATING MANUAL RAY-NC 1000 SERIES

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

FDCL221-Ex Line adapter (Ex)

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

OPTIBAR DP 7060 Supplementary Instructions

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

Operating Instructions Edition 02/2007

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

SET Installation and Operating Instructions. Level switch for one sensor

COMPACT FLAME CONTROLLER CFC 2000

PROTECT SRB 200EXi-1A

Gas cylinder scale Model GCS-1

IECEx Certificate of Conformity

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Technical Data. Dimensions

EU DECLARATION OF CONFORMITY

IECEx Certificate of Conformity

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

SET-2000 Oil/Sludge 12 VDC

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

INSTRUCTION MANUAL (ATEX)

Technical Data. General specifications. Rated operating distance s n 5 mm

MANUAL Oil Level Sensor

Manual OW Caution:

PEPPERL+FUCHS GmbH

VERSAFLOW VORTEX Supplementary instructions

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Rosemount 702 Wireless Discrete Transmitter

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Dual certification! Air handling units for potentially explosive atmospheres

Annubar Flowmeter Series

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

OilSET-1000 (12 VDC)

Technical Data. Dimensions

SET-2000 Hi Level/Oil

Hazardous Location Heaters. 50W and 80W Models INSTRUCTION MANUAL. Rev. I 2018 nvent P/N

COMPACT FLAME CONTROLLER CFC 100

Universal Tank Alarm Type Installation, Operation & Maintenance

Installation and Operating Instruction

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals:

MANUAL Overflow sensor NVF-104/34-PF

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Operating Instructions

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

DB5 Intrinsically Safe Sounder Type DB-5

Certification Supplement Manual

14300 MAINS SEPARATOR ALARM MANUAL

MANUAL. for heat press. Secabo TC2

Magnetostrictive sensor For bypass level indicators Model BLM

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Instructions SCHICK ceramic - milling set

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AO Annunciator Module

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Manual. Monitoring Device BS

PIT UMF2 (B) Magnetic-Inductive Flow Velocity Sensor. Operating Manual. Page 1 of 14

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

Transcription:

D461 Manual Isolating Barrier D461 (Revision 05) Product Manual Original Instructions valid for models D461.11 with 1x signal input into 1x isolated signal output D461.12 with 1x signal input into 2x isolated signal output D461.21 with 2x signal input into 2x isolated signal output D461 View Isolating Barrier with sensor supply and circuit monitoring ATEX II (1) G [Ex ia Ga] IIC CE 0123 TPS 03 ATEX 1 006 D461-Manual_EN_Rev05 2017_09_08 Page 1 to 25

Table of Contents Content Table of Contents... 2 1 General Information... 3 1.1 List of Figures... 3 1.2 Functions and Application... 4 1.3 Installation... 4 1.4 Sensor supply circuit monitoring... 4 1.5 Circuit Isolation... 4 1.6 Ordering key for isolating barriers series D461... 5 1.7 Approvals... 6 1.7.1 ATEX... 6 1.7.2 IECEx... 6 1.7.3 EAC... 6 1.7.4 ATEX EC-Type Examination Certificate... 7 1.7.5 IECEx Certificate of Conformity... 9 1.7.6 EAC TR CU Certificate... 13 1.7.7 EU Declaration of Conformity... 16 2 Hazardous protection... 17 2.1 Relevant technical Data for Hazardous Area... 17 2.2 ATEX Certification for Intrinsic Safety of the Input Circuit... 17 3 Function Diagram and Connections... 18 3.1 Function Diagram and Connection D461.11... 18 3.2 Function Diagram and Connection D461.12... 19 3.3 Function Diagram and Connection D461.21... 20 4 Technical Specifications... 21 4.1 Technical Data of Inputs (intrinsic safe)... 21 4.2 Technical Data of Outputs... 21 4.3 Technical Data of Power Supply... 21 4.4 Environmental conditions... 21 4.5 Protection Grade... 21 4.6 Connectors... 22 4.7 Conformity to Standards... 22 4.8 Dimensions... 23 4.9 Weight... 23 5 Safety Notes for Installation and Operation... 24 5.1 Safety Notes for Installation... 24 5.1.1 General Instructions... 24 5.1.2 EMI... 24 5.2 Safety Notes for Operation... 24 5.2.1 Safety Notes on Commissioning... 24 6 Revision Notes... 25 Page D461-Manual_EN_Rev05 2017_09_08 Page 2 to 25

1 General Information 1.1 List of Figures Figure 1: ATEX EC-Type Examination Certificate part 1... 7 Figure 2: ATEX EC-Type Examination Certificate part 2... 8 Figure 3: IECEx Certificate of Conformity part 1... 9 Figure 4: IECEx Certificate of Conformity part 2... 10 Figure 5: IECEx Certificate of Conformity part 3... 11 Figure 6: IECEx Certificate of Conformity part 4... 12 Figure 7: EAC TR CU Certificate part 1... 13 Figure 8: EAC TR CU Certificate part 2... 14 Figure 9: EAC TR CU Certificate part 3... 15 Figure 10: EU Declaration of Conformity... 16 Figure 11: Function Diagram and Connection D461.11... 18 Figure 12: Function Diagram and Connection D461.12... 19 Figure 13: Function Diagram and Connection D461.21... 20 Figure 14: Dimensions of unit D461... 23 D461-Manual_EN_Rev05 2017_09_08 Page 3 to 25

1.2 Functions and Application The isolating barrier establishes an intrinsic safety circuit (Ex ia) feeding the sensor, and receiving the sensor signal. The incorporated opto coupler separates this input from the subsequent circuit. The output of the unit repeats the input pulse signals, with inverted sequence but enforced level, to feed electronic measurements, alarms, totalizers, or controllers. Characteristics of the input circuit immediately match the specifications of the speed sensor series A5S1, which are approved as intrinsic safety devices, to be installed in a hazardous area if properly supplied. The barrier unit D461 must be placed in a safe (non-hazardous) area, or within an explosionproof enclosure. A speed sensor series A5S1, in combination with the barrier D461 thereby establishes an efficient speed sensing system, to supply high-level output signals to the periphery. Version D461.11 The barrier D461.11 incorporates one signal input for single-channel sensors and one signal output. Version D461.12 The barrier D461.12 incorporates one signal input for single-channel sensors and two signal outputs. Both signal outputs repeat the input pulse signal. Version D461.21 The barrier D461.21 incorporates two signal inputs for dual-channel sensors and two signal outputs. The signal outputs repeat one input pulse signal each. 1.3 Installation The barrier D461 is designed for indoor use (NEMA 1), e.g. within switchboards, racks or cabinets. Screw mounting or snap-on-track (DIN 50022 / 35 mm) can be used. Protection grade IP20. As a special version, the barrier is available in enclosure grade IP65 (NEMA4), or in explosionproof enclosure (Exd II C T5). 1.4 Sensor supply circuit monitoring The sensor supply circuit is monitored against lead break and short circuit. A fault is announced by alarm relay. An additional transistor output is non-conductive in case of fault. The transistor output can be connected to the sensor supply of a subsequent module, thus enabling its own sensor supply circuit monitor. 1.5 Circuit Isolation Input, output and power supply are isolated from each other. The output circuit must not be connected to other devices having an operational voltage exceeding 375 volts (peak). D461-Manual_EN_Rev05 2017_09_08 Page 4 to 25

1.6 Ordering key for isolating barriers series D461 D461. a b Channels incorporated a = 11 : 1x signal input into 1x isolated signal output a = 12 : 1x signal input into 2x isolated signal output a = 21 : 2x signal input into 2x isolated signal output Supply voltage b = U1 : 18 40 V AC resp. V DC b = U2 : 85 250 V AC Examples: D461.11U2 D461.11U1 D461.12U1 D461.21U2 = with 1x signal input into 1x isolated signal output for 85...250 V AC = with 1x signal input into 1x isolated signal output for 18...40 V AC resp. V DC = with 1x signal input into 2x isolated signal output for 18...40 V AC resp. V DC = with 2x signal input into 2x isolated signal output for 85...250 V AC D461-Manual_EN_Rev05 2017_09_08 Page 5 to 25

1.7 Approvals 1.7.1 ATEX The isolating barrier series D461 is certified according to ATEX EC-Type Examination Certificate No. TPS 03 ATEX 1 006 and is compliant according to ATEX Product Directive 2014/34/EU. 1.7.2 IECEx The isolating barrier series D461 is certified according to IECEx Certificate of Conformity No. TPS 09.0003. 1.7.3 EAC The isolating barrier series D461 is approved for EAC (Russia, Kazakhstan and Belarus Customs Union) according to TR-Certificate No. RU D-DE.GB05.B.01176. D461-Manual_EN_Rev05 2017_09_08 Page 6 to 25

1.7.4 ATEX EC-Type Examination Certificate Figure 1: ATEX EC-Type Examination Certificate part 1 D461-Manual_EN_Rev05 2017_09_08 Page 7 to 25

Figure 2: ATEX EC-Type Examination Certificate part 2 D461-Manual_EN_Rev05 2017_09_08 Page 8 to 25

1.7.5 IECEx Certificate of Conformity Figure 3: IECEx Certificate of Conformity part 1 D461-Manual_EN_Rev05 2017_09_08 Page 9 to 25

Figure 4: IECEx Certificate of Conformity part 2 D461-Manual_EN_Rev05 2017_09_08 Page 10 to 25

Figure 5: IECEx Certificate of Conformity part 3 D461-Manual_EN_Rev05 2017_09_08 Page 11 to 25

Figure 6: IECEx Certificate of Conformity part 4 D461-Manual_EN_Rev05 2017_09_08 Page 12 to 25

1.7.6 EAC TR CU Certificate Figure 7: EAC TR CU Certificate part 1 D461-Manual_EN_Rev05 2017_09_08 Page 13 to 25

Figure 8: EAC TR CU Certificate part 2 D461-Manual_EN_Rev05 2017_09_08 Page 14 to 25

Figure 9: EAC TR CU Certificate part 3 D461-Manual_EN_Rev05 2017_09_08 Page 15 to 25

1.7.7 EU Declaration of Conformity EU-Konformitätserklärung EU Declaration of Conformity BRAUN GmbH Industrie-Elektronik, Esslinger Str. 26, 71334 Waiblingen, Germany erklärt in alleiniger Verantwortung, declares in its sole responsibility, dass das Produkt: that the product: Typ(en), types: Trennstufe Isolating Barrier D461 den genannten Europäischen Richtlinien und harmonisierten Normen entspricht, is in conformity with the listed European Directives and harmonized standards. EU-Richtlinie(n) / EU-Directive(s) Norm(en), Standard(s) 2014/34/EU 2014/34/EU ATEX-Produktrichtlinie ATEX Product Directive EN 60079-0:2012+A11:2013 EN 60079-11:2012 Kennzeichnung, marking: II (1) G [Ex ia Ga] IIC 0123 EG/EU-Baumusterprüfbescheinigung Nr.: EC/EU Type Examination Certificate No: Aussteller, notified Body: Benannte Stelle Nr., notified Body No: EU-Richtlinie(n) / EU-Directive(s) TPS 03 ATEX 1 006 TÜV SÜD Product Service GmbH Ridlerstr. 65, D-80339 München 0123 Norm(en), Standard(s) 2014/30/EU 2014/30/EU 2014/35/EU 2014/35/EU 2011/65/EU 2011/65/EU EMV-Richtlinie EMC Directive Niederspannungsrichtlinie Low Voltage Directive (LVD) RoHS-Richtlinie RoHS Directive EN 61326-1:2013 EN 61326-3-2:2008 EN 61010-1:2010 EN 50581:2012 Diese Erklärung gilt für alle Produkte, die mit Typenschildern der oben genannten Typen versehen sind. Zusatzbezeichnungen an Stelle von... stehen für die spezifische Ausführung. This declaration is valid for all products, which are provided with type labels of the types mentioned above. Suffixes instead of... are dummy variables for the specific model. Unbedingte Beachtung aller Punkte der mitgelieferten Betriebsanleitung ist hierbei Voraussetzung. Strict observance of the operation manual is an indispensable precondition, hereto. Unterzeichnet für und im Namen der BRAUN GmbH / Signed for and on behalf of BRAUN GmbH Waiblingen, 2017-09-08 Ort und Datum Place and date Albrecht Braun Geschäftsführer Managing Director Figure 10: EU Declaration of Conformity D461-Manual_EN_Rev05 2017_09_08 Page 16 to 25

2 Hazardous protection The safety requirements as determined by EN 1127-1, as well as the corresponding national regulations, are to be complied with regarding primary explosion protection, i.e. measures which prevent or restrict the formation of a hazardous explosive atmosphere. In the case of secondary hazardous protection, i.e. measures that prevent the ignition of an explosive atmosphere surrounding electrical equipment, the series of standards applicable to EN 60079 and the relevant national regulations must be observed. 2.1 Relevant technical Data for Hazardous Area Approved maximum values: Uo = 8.7 V Io = 62 ma Co = 300 nf Lo/Ro = 883 µh/ohms Lo = 2 mh Po = 130 mw 2.2 ATEX Certification for Intrinsic Safety of the Input Circuit II (1) G [Ex ia Ga] IIC Marking of notified Body: CE0123 EC-Type Examination Certificate: TPS 03 ATEX 1 006 D461-Manual_EN_Rev05 2017_09_08 Page 17 to 25

3 Function Diagram and Connections 3.1 Function Diagram and Connection D461.11 Figure 11: Function Diagram and Connection D461.11 D461-Manual_EN_Rev05 2017_09_08 Page 18 to 25

3.2 Function Diagram and Connection D461.12 Figure 12: Function Diagram and Connection D461.12 D461-Manual_EN_Rev05 2017_09_08 Page 19 to 25

3.3 Function Diagram and Connection D461.21 Figure 13: Function Diagram and Connection D461.21 D461-Manual_EN_Rev05 2017_09_08 Page 20 to 25

4 Technical Specifications 4.1 Technical Data of Inputs (intrinsic safe) Response level 4 V, Input impedance approx. 47 k. Sensor supply (operational value) 8 volts. Approved maximum values: Uo = 8.7 V Io = 62 ma Co = 300 nf Lo/Ro = 883 µh/ohms Lo = 2 mh Po = 130 mw Versions D461.11 and D461.12 The sensor has to be connected to the signal input by 3 leads shielded cable. Recommended wire cross section LiYCY 3x0.5 or larger. Version D461.21 The sensor has to be connected to the signal input by 4 leads shielded cable. Recommended wire cross section LiYCY 4x0.5 or larger. 4.2 Technical Data of Outputs Outputs are short-circuit-proof and free floating versus power supply and input. Active pulses by push-pull transistor output stage, sequence inverting the input signal. Output level with maximum load towards 0 V: Output level with maximum load towards 24 V: High-Level approx. 18 V Low-Level 0 V High-Level approx. 20 V Low-Level approx. 2 V Version D461.11 incorporates one signal output, versions D461.12 and D461.21 incorporate two signal outputs each. 4.3 Technical Data of Power Supply D461.xxU1: 18...40 V AC resp. V DC, power requirements approx. 5 VA. D461.xxU2: 85...250 V AC, power requirements approx. 5 VA. 4.4 Environmental conditions Ambient temperature in operation: 0...+50 C Ambient temperature in storage: -20 C..+85 C Relative humidity: < 95%, non-condensing To be installed in dry cabinets in air-conditioned rooms Up to 2000 meters above sea level 4.5 Protection Grade Protection Grade: IP20 As a special version, the barrier is available in enclosure grade IP65 (NEMA4), or in explosion-proof enclosure (Exd II C T5). D461-Manual_EN_Rev05 2017_09_08 Page 21 to 25

4.6 Connectors Connectors with Pull Spring Terminals 4.7 Conformity to Standards EU-Directives Standards 2014/34/EU ATEX Product Directive EN 60079-0, EN 60079-11 2014/30/EU EMC Directive EN 61326-1, EN 61326-3-2 2014/35/EU Low Voltage Directive (LVD) EN 61010-1 2011/65/EU RoHS Directive EN 50581 D461-Manual_EN_Rev05 2017_09_08 Page 22 to 25

4.8 Dimensions 26 25 24 23 22 75 Front View all dimensions in mm 1 2 3 4 5 6 7 8 9 10 11 12 13 70 Position of terminal blocks 110 Side View all dimensions in mm 35 Snap-on-track enclosure for DIN 50022 (35 mm) 75 Figure 14: Dimensions of unit D461 4.9 Weight approx. 0.4 kg. D461-Manual_EN_Rev05 2017_09_08 Page 23 to 25

5 Safety Notes for Installation and Operation 5.1 Safety Notes for Installation The isolating barriers series D461 has been designed and tested according to the standards EN 61010-1 (VDE 0411-1) and have left the factory in perfect safety condition. To maintain this condition and to ensure safe operation, the user must observe the notes and wiring diagrams contained in this operating manual. Installation and maintenance work must be done only by adequately qualified personnel and only when the power supply is switched off. 5.1.1 General Instructions The isolating barriers series D461 shall be installed in the non-hazardous area, resp. protected by an explosion-proof enclosure. 5.1.2 EMI The isolating barriers series D461 complies with all relevant regulations, as determined by the Policy of the European Committee for Electrotechnical Standardization (CENELEC), for the Electromagnetic Compatibility (2014/30/EU). Testing and inspection have been performed according to Standards EN 61326-1 and EN 61326-3-2. Thereby, the product meets all requirements to be marked by the CE sign. Strict observance of these instructions during installation and use is an indispensable precondition hereto. 5.2 Safety Notes for Operation 5.2.1 Safety Notes on Commissioning Commissioning must be carried out by sufficiently competent and qualified personnel. During commissioning of the entire machine, the commissioning technician must ensure that the measuring chains function properly. D461-Manual_EN_Rev05 2017_09_08 Page 24 to 25

6 Revision Notes Note: At editorial changes, only the release date is updated. At technical changes, the release date is updated, and the revision index is increased. Date Rev. Modification 1999-03-12 00 First Edition 2016-04-20 01 Editorial: Chapter 1.7.7: Update of EU Declaration of Conformity, Directives, and Standards 2016-11-30 02 Editorial: Chapter 1.7.7 and 4.7: 2006/95/EU replaced by 2014/35/EU, Chapter 1.7.7: Update of EU Declaration of Conformity, Directives, and Standards 2017-01-25 03 Editorial: Change to Bookmark Format Summary of the three manuals of versions D461.11, D461.12, and D461.21 to one manual 2017-05-15 04 Editorial: Chapter 2.1 and 4.1: Correction of unit of Co value 2017-09-08 05 Editorial: Chapter 1.7.7, 4.7 and 5.1.2: Adaptation of EMI Standards Qualität zertifiziert nach ISO 9001 D 71334 Waiblingen-Hegnach Esslinger Str. 26 Tel.: +49 (0)7151/956230 Fax: +49 (0)7151/956250 E-Mail: info@braun-tacho.de Internet: www.braun-tacho.de D461-Manual_EN_Rev05 2017_09_08 Page 25 to 25