INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

R-410A, 13 SEER LATITUDE SERIES

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTION

ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

USER'S MANUAL/INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

SECTION 7 AIR CONDITIONING (COOLING) UNIT 38 INSTALLATION

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

MODELS B1PA024, 030 AND 036

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Your safety and the safety of others are very important.

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

Installation Instructions

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Installation Instructions

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Installation Instructions

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz SERIES RV ROOF TOP AIR CONDITIONER/HEAT PUMP

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

HVAC Equipment Access Equipment Location

Installation Instructions

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

USER s MANUAL & INSTALLATION INSTRUCTIONS. Single Package Heat Pump IMPORTANT:

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Installation & Maintenance Data IM Contents

Installation Instructions

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

AHG**-0B Series Hydronic Air Handling Units

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

User s Information and Installation Instructions

INSTALLATION INSTRUCTIONS

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Installation Instructions

Horizontal/Side Discharge Condensing Units

USER s MANUAL & INSTALLATION INSTRUCTIONS IMPORTANT

Installation Instructions

e Bath Fan with Light User s Guide

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

PACKAGE AIR CONDITIONER

Installation Instructions

INSTALLATION INSTRUCTIONS

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

T-Series Air Conditioner T20 Model

e Bath Fan with Light User s Guide

Installation Instructions

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

INSTALLATION INSTRUCTIONS

e Bath Fan with Light User s Guide

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

WHY YOUR AIR CONDITIONER WORKS SO WELL, SO QUIETLY

e Heater/Exhaust Fan/Light User s Guide

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

T-Series Air Conditioner T53 Model

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Inspection Checklist Mechanical Rough in

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

ACCESSORY KIT INSTALLATION INSTRUCTIONS

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

INSTALLATION INSTRUCTIONS

Transcription:

INSTALLATION INSTRUCTIONS PACKAGED HEAT PUMP Table of Contents GENERAL INFORMATION.................. 2 VISUALLY INSPECT PRODUCT............... 2 INTRODUCTION........................... 2 OPTIONAL KITS........................... 3 COMPLY WITH LOCAL CODES............... 3 CHECK ELECTRICAL POWER SUPPLY........ 3 SIZING HEAT PUMP TO HOME............... 3 SELECTING THE BEST LOCATION FOR THE UNIT................................. 3 HEAT ACCESSORY........................ 4 INSTALLATION........................... 4 SITE PREPARATION........................ 4 DUCTING TO UNIT - MANUFACTURED HOUSING 4 DISCHARGE DUCT INSTALLATION............ 5 WYE INSULATION.......................... 6 DUCTING TO UNIT - RESIDENTIAL............ 6 INSTALLING DRAIN TUBE AND CONNECTION.. 6 ELECTRICAL SUPPLY WIRING............... 8 HIGH VOLTAGE............................ 8 LOW VOLTAGE............................ 8 WALL THERMOSTAT INSTALLATION.......... 9 CHECK-OUT............................. 9 PRE-START PROCEDURE................... 9 SYSTEM START-UP, CHECK-OUT............ 9 OTHER FEATURES INCORPORATED IN THE CONTROL............................... 10 IMPORTANT - These instructions are intended for the use of qualified individuals specially trained and experienced in installation of this type of equipment and related system components. Installation and service personnel are required by some states to be licensed. Persons not qualified shall not install this equipment or interpret these instructions. Improper installation may damage equipment, can create a shock hazard, and will void the warranty. NOTE: The words Shall" or Must" indicate a requirement which is essential to satisfactory and safe product performance. The words Should" or May" indicate a recommendation or advice which is not essential and not required but which may be useful or helpful. CAUTION: READ ALL SAFETY GUIDES BEFORE YOU START TO INSTALL YOUR UNIT. SAVE THIS MANUAL IMPORTANT - Do not run the heat pump without the blower access door attached as air will not be drawn across the indoor coil. This will cause the compressor to trip" off. 035-16310-002 Rev. A (0804)

GENERAL INFORMATION VISUALLY INSPECT PRODUCT Check the unit thoroughly for shipping damage (If there is damage file a claim with the shipper). Unusually rough handling during shipment may loosen blowers, fan motors, compressors, or other components. Re-tighten any loose components before installing the unit. Be sure that the heat pump is ready to operate before installing it. Packed in the return air compartment of this unit are the duct connector flanges (round) needed for attaching the return and supply ducts to the unit. Packed in the control box of this unit is a small parts package containing: a. Condensate drain tube and drain fitting, b. Hose clamp, c. Screws to attach duct flanges. INTRODUCTION This heat pump is designed to be installed alongside the home or building to handle all cooling, heating and air handling, in a self-contained package. (See Figure 1.) The air from the living space of the home is brought out to the unit by return ducts and sent back into the home by supply ducts. Only two electrical cables are needed between the heat pump and the home; the electrical power supply cable to the unit and the thermostat cable to the wall thermostat in the home. An outdoor thermostat (optional for use with the auxiliary heat accessory) controls the heating element(s) when the balance point" has been reached. (See Sizing Heat Pump to Home). Emergency heat, if needed, can be provided from heating elements within the unit. These units contain a lock-out relay. The purpose of the lockout relay is to prevent the compressor from stopping and starting in response to cycling of the high temperature or high pressure switch. Should either the high temperature or the high pressure switch open, indicating a problem in the refrigeration system, the lock-out relay is energized, opening the compressor contactor circuit. The compressor will remain off until the lock-out relay is reset, even though the safety switches may close. This prevents rapid cycling of the compressor. The lock-out relay also illuminates the emergency heat light of the wall thermostat and closes a circuit to allow the heating elements to operate in response to the second stage of the wall thermostat when the system is in the heating mode. The lock-out relay is reset at the wall thermostat by moving the system switch to OFF, then returning to the desired mode of operation. It is important to recognize that the activation of the lock-out relay indicates that either the high temperature or the high pressure switch opened; signalling a malfunction in the system. Resetting the relay will not cure the system problem. If a "lock-out" should re-occur it will be necessary to attach gauges to the outdoor unit and observe its operation. TIGHTEN SCREW TO EXTEND GAUGE PORT BLOWER COMPARTMENT HEATER ACCESSORY KNOCK-OUTS CONTROL WIRING OPENINGS FIGURE 1 2 Unitary Products Group

OPTIONAL KITS Optional kits for this heat pump system are: 1. Wall thermostat (ordered separately - several models available.) 2. Electric heater package (ordered separately - several models available.) 3. Starting components (standard on some models) (ordered separately.) 4. Circuit breakers for use with auxiliary electric heat (ordered separately.) 5. Outdoor thermostat (ordered separately.) COMPLY WITH LOCAL CODES The installer must comply with all local codes and regulations which govern the installation of this type of equipment. Local codes and regulations take precedence over any recommendations contained in these instructions. In lieu of local codes, the equipment should be installed in accordance with the National Electric Code, and in accordance with the recommendations made by the National Board of Fire Underwriters. CHECK ELECTRICAL POWER SUPPLY The electrical power should be checked to determine if adequate power is available. Voltage should not vary more than 10% of that stamped on the unit nameplate. If there is any question concerning the power supply, contact the local power company for corrections; otherwise, unsatisfactory performance may result. For information concerning wire size and other wiring information, see Unit Data Sheet and Installation Instructions for the Heat Accessories. SIZING HEAT PUMP TO HOME Heat pumps may be sized to a home by either of the following methods 1. Cooling Load Calculations of the home: This method can be used satisfactorily in the southern half of the U.S. Since heating loads are greater than cooling loads in the North, it is more difficult to size a heat pump that will meet the heating requirements of the home when based only on the cooling load. Slight over-sizing of the Heat Pump System up to 25 or 30 percent can be made without adverse conditions (i.e., less summer humidity control, higher utility bills) becoming too noticeable in Northern installations to gain a little more heating in the winter. The heat accessory must be sized according to the heat loss of the home the farther North the installation is made. Should the heat loss show that it is unnecessary to provide auxiliary electric heat, a minimum of 4.8 KW is desirable to temper the air supplied to the home during defrost periods. 2. Specified Heating Balance Point of the home: With this method the heating capacity of the heat pump is plotted on a graph against the heat loss of the home in order to determine the balance point". The specified balance point" is the temperature at which the heat loss of the home balances with the output capacity of the heat pump. When the outside temperature drops below the balance point and the heat input by the heat pump cannot maintain the interior desired temperature of the home, then auxiliary heating must be added to help maintain the desired interior temperature. SELECTING THE BEST LOCATION FOR THE UNIT Several important factors must be considered before selecting the site for the heat pump: Site Select a solid, level position, preferably on a concrete slab, slightly above grade level and parallel to the home. Proximity to Home or Building The length of the supply and return ducts should be kept to a minimum with no sharp bends. Consideration should be given to the distance and routing of electrical service to connect the unit. Try to select a site for the unit that it is as close as possible to the proposed return grille location. Proximity to the Clothes Dryer Vent The clothes dryer vent should not be located upwind from the unit. Ability to Service Side access panels of the unit should not be closer than 18 inches to a structure so blower and controls may be serviced. Sound Transmission Locate the unit away from bedroom windows or other rooms where sound may be objectionable. Air Circulation The outside coil sides should not be closer than 10 inches to a structure that will restrict air flow through the coil. The air discharge of the unit requires a 60-inch clearance between the top of the unit and any obstructions. (See Figure 2.) Wind Direction The hot condenser air must be discharged up and away from the home or building, and if possible in a direction with the prevailing wind. Relationship Between Building, Sun and Unit If practical, place the heat pump in an area where the unit and the ducts will be shaded from the afternoon sun (when the heat load is the greatest.) Defrost and Water Drainage Water will run off the outdoor coil when the heat pump defrosts during the heating season. This water will run through the drain holes of the heat pump base pan onto the Unitary Products Group 3

INSTALLATION SITE PREPARATION 60 1. After the site has been selected and prepared, using criteria mentioned above, install the heat pump support pad at the selected site. 2. Mount the heat pump securely and level to the support. NOTE: This unit must be installed and operated on a level surface. Failure to do so will result in condensate drainage problems. DUCTING TO UNIT - MANUFACTURED HOUSING FIGURE 2 ground below. A slight grade away from the unit will improve drainage. To avoid personal injury, locate the heat pump away from foot traffic areas. the water from defrosting may form an ice sheet on the ground around the unit. Average Winter Snow Depth The heat pump must be installed above the average snow depth to allow the outdoor coil to drain properly. Cinder blocks, if permitted by local codes, or a metal frame may be used to support the unit above the snow. Insure that the support does not obstruct drainage holes in the base pan of the unit. Metal frame legs must be supported by concrete pads. The heat pump must set level and securely upon the support. NOTE: If installing on blocks, the middle rail must be supported. HEAT ACCESSORY The heater and outdoor thermostat may be installed in the unit at the shop. See the Installation Instructions for the Heat Package for installation and internal wiring of the heat pump. Flanges for round ducts are packaged with the unit. Attach the flange to the unit. The unit's supply and return ducts are sized for optimum performance. See Data Sheet for this unit. Should the duct work connecting to the heat pump be of smaller dimensions, it is recommended that transitions connecting the ducts to the unit be constructed to allow a smooth airflow to the heat pump's return air opening and from the supply air opening. Abrupt duct size changes increase the system static pressure and reduces air volume which may cause unsatisfactory performance. Duct work should be in accordance with local and national codes. Duct work exposed to outside environmental conditions must be insulated and weather proofed. Outside wall openings through which the ducts pass must be weather proofed in accordance with good construction practices. Supply and return air ducts passing through unconditioned spaces of the building must be insulated and covered with a vapor barrier. Following this practice will prevent thermal losses and condensate formation on the ducts. Supply and Return Ducts Duct should be 12" diameter when using Insulated Flex Duct. Maximum external duct static pressure is.8" water column. Metal ducts may be used when properly insulated and vapor proofed. Any duct used should be covered with insulation having a minimum R value of 4.0 and should be covered with vapor barrier. Comply with any local codes or standards regarding duct material. Install the heat pump duct connectors to the unit. Insure that the seam is towards bottom. A good quality duct tape should be used to insure an airtight installation. The Return-Air Grille Boxes The Return-air Assembly should be installed first. The Return- Air Grille Box and Filter should be located and installed in the out-rigger" areas of the home. Keep in mind, the closer to the outdoor unit, the better. The Return Duct connects to the bottom of the Return-Air Box so it will be necessary to provide an opening beneath the box. (See Figure 3.) After determining the location of the Return-Air opening, start installation from beneath the manufactured home. 4 Unitary Products Group

GRILLE FILTER Keep flexible ducts straight and short. Wide sweeping bends should be used when turns are necessary, not sharp corners or angles. 1. When Return-air Grille Box is installed, run the duct to the Return-air inlet flange on the unit. 2. Cut the duct to the required length using a knife, or tin snips, and cut the helical wire with a wire cutter. 3. Insert a stub collar in the raw end of the duct and tape securely in place. 4. Make sure the duct is not stretched tight and does not have kinks from excessive length after installation. 5. Attach the duct end, with the stub collar, to the heat pump return-air flange with screws and duct tape sealing the duct cover securely. DISCHARGE DUCT INSTALLATION FIGURE 3 RETURN BOX 1. Cut a small hole in the fiber underboard to determine floor joist location. Floor joists are generally located on 16" centers, leaving 14-3/8" between joists. 2. Cut a 14-3/8" x 20-1/2" rectangular hole in the floor between two joists. 3. Set the return box into the opening and mark a circular pattern on the fiber underboard through the flex duct connector collar, then remove the return box from the opening. 4. Cut outside of the circular mark to allow enough space to pull the flex duct up through the hole and fasten to the return box. 5. When attaching the duct to the return air box, secure the duct collar and return box collar together with at least three (3) sheet metal screws and seal with duct tape. 6. Set the return air box, with flex duct attached, back into the floor opening. 7. Fasten the return air box securely to the floor with screws or nails. 8. Seal fiber underboard hole around flex duct. For ease of installation of the flexible ductwork, it is recommended that as much work as possible be done outside the undercoach area. Accurate measurements are a must. Plan the ducting configuration well and double check the measurements. Remember, each slight change in direction of the duct adds static resistance and reduces air-flow. If an interior furnace or air handler will be connected to the supply duct system, the supply duct connector should be equipped with a damper. (See Figure 4.) If no interior furnace or air handler will be connected, the duct connector may be a 12" diameter duct. (See Figure 5.) When locating the Duct Connector, check carefully for floor joists, axles, wheels and frame members that could interfere with the installation of the Duct Connector or the running of the duct. Ideally, the Duct Connector should be located in the bottom of the main duct, forward of center of the manufactured home. Do not install Duct Connector under a register. The "offset" installation will help eliminate the transmission of sound into the home. To locate the center of the duct, first cut a 6" hole in the fiberboard below the duct at the desired location. After locating the duct center, increase the hole in the fiberboard to approximately the size of the Duct Connector. If using the duct connector with damper, cut a 9-1/8" x 16-1/ 18" hole in the center of the duct bottom. If using the 12" diameter duct connector without damper cut a 12-1/8" diameter hole in the center of the duct bottom. Place the duct connector in the hole and secure tightly with the tabs. If necessary, support duct connector with support braces. (See Figures 4 and 5.) NOTE: It is advisable to tape joints AT THE DUCT CON- NECTOR air tight. There is extreme pressure exerted by the blower at this point. If the filter box and duct connector are to be installed on a manufactured home that has in-floor air to a furnace, it will be necessary to seal all openings made in the fiberboard to avoid air leaks. Unitary Products Group 5

FACTORY INSTALLED HINGED, HEATING DAMPER. BLOCKS FLOW OF WARM AIR INTO CONDENSING UNIT DURING HEATING SEASON. 3. Tape to insulation placed on bottom of Wye tape together diaper style. 4. Make sure a tight bond is obtained and attach to flexible duct sleeves with tape. 5. Tape insulation to Return-Air opening flange, air-tight. NOTE: The insulation should NOT be compressed around the Wye. This defeats the purpose of the insulation. DUCTING TO UNIT - RESIDENTIAL DUCT CONNECTOR (WITH DAMPER) FIGURE 4 FIGURE 5 DUCT CONNECTOR (NO DAMPER) WYE INSULATION It is necessary to field fabricate and install an insulation jacket for the Wye. Insulation will prevent loss of capacity especially where the gain or loss is critical in a borderline installation. (See Figures 6 & 7.) 1. Use faced batt insulation material. 2. Place the insulation on the top side of the Wye, with the faced or vinyl side out. Flanges are provided to help install the ducts to the heat pump. The duct flanges must be field installed on the unit's side. The unit's supply and return air connections are sized for optimum performance. See Data Sheet packed with unit. Should the duct work connecting to the heat pump be of smaller dimensions, it is recommended that transitions connecting the ducts to the unit be constructed to allow a smooth airflow to the heat unit's return air opening and from the supply air opening. Abrupt duct size changes increase the system static pressure and reduces air volume which may cause unsatisfactory performance. Duct work should be in accordance with local and national codes. Duct work exposed to outside environmental conditions must be insulated and weather proofed. Outside wall openings through which the ducts pass must be weather proofed in accord with good construction practices. Supply and return air ducts passing through unconditioned spaces of the building must be insulated and covered with a vapor barrier. Following this practice will prevent thermal losses and condensate formation on the ducts. INSTALLING DRAIN TUBE AND CONNECTION A drain tube, a barbed elbow plastic fitting, and a plastic hose clamp are provided in the small parts package packed in the control box. 1. To insure proper condensate drainage, the barbed plastic elbow fitting should be screwed into the unit drain fitting (located in the rear corner of the unit), and the drain tube installed on the barbed end of the plastic fitting secured to plastic fitting with the plastic hose clamp. 2. If it is necessary to drain water away from unit, attach a drain hose to the drain tube. IMPORTANT - The drain hose must not rise above the level of the drain fitting at any point in its routing. Failure to do so will result in condensate water overflowing into the unit's interior. 6 Unitary Products Group

1 12 DUCT CONNECTORS GRILLE FILTER RETURN BOX DAMPER* DAMPER* 2 FLEX DUCT 1 MAY USE DUCT CONNECTOR WITHOUT DAMPER IF NO INTERIOR FURNACE OR AIR HANDLER IS CONNECTED TO DUCT SYSTEM. 2 RETURN DUCT MAY BE OVERSIZED TO ACCOMMODATE THE MAXIMUM 8 STATIC PRESSURE. FIGURE 6 INLET FLANGE 12x12x12 WYE OUTLET FLANGE 4 FLEX DUCT WYE INSULATION RECOMMENDED FOR GREATER EFFICIENCY AND PERFORMANCE OF UNIT. SEPARATE ACCESSORIES AVAILABLE: 7336A5811 WYE (12 DIA.) 7336-7121 DUCT CONNECTOR AND FILTER PKG. 7336-5801 DUCT CONNECTOR GRILLE FILTER RETURN BOX GRILLE FILTER RETURN BOX 2 FLEX DUCT DAMPER* 1 12 DUCT CONNECTORS DAMPER* FLEX DUCT FLEX DUCT 1 MAY USE DUCT CONNECTOR WITHOUT DAMPER IF NO INTERIOR FURNACE OR AIR HANDLER IS CONNECTED TO DUCT SYSTEM. 12x12x12 WYE 12x12x12 WYE WYE INSULATION RECOMMENDED FOR GREATER EFFICIENCY AND PERFORMANCE OF UNIT. 2 RETURN DUCT MAY BE OVERSIZED TO ACCOMMODATE THE MAXIMUM 8 STATIC PRESSURE. FIGURE 7 INLET OUTLET FLANGE FLANGE 4 SEPARATE ACCESSORIES AVAILABLE: 7336A5811 WYE (12 DIA.) 7336-7121 DUCT CONNECTOR AND FILTER PKG. 7336-5801 DUCT CONNECTOR Unitary Products Group 7

ELECTRICAL SUPPLY WIRING NOTE: Field wiring must comply with the National Electric Code and local codes that may apply. 4. Unless the heat pump is grounded through proper wiring to the service entrance ground terminal, a suitable separate ground must be provided at the heat pump using the grounding lugs provided. SHOCK HAZARD - Turn off all electrical power before servicing, to prevent possible equipment damage and possible personal injury. IMPORTANT - The power wiring should be run in rain tight, grounded conduit between the disconnect and the heat pump. A 230 volt service disconnect switch must be installed within sight of the heat pump. HIGH VOLTAGE This heat pump is equipped to accept a single circuit of supply power. If an auxiliary heater is installed, dual circuiting to the unit can be used. When installing a 14.3 KW heater, this method will avoid the use of large wiring. To provide single circuiting, an optional jumper bar can be used to electrically connect the circuit breakers provided with the heater kit. If auxiliary electric heaters are not installed, refer to data sheet for minimum circuit ampacity, maximum overcurrent protective device size, and minimum wire size. If auxiliary electric heaters are being installed, refer to the installation instructions (included with heater packages) for electrical requirements and wiring information. Remove block-off plate shown in Figure 8. To wire this system without the use of auxiliary electric heat, remove the control box access door. 1. Install a service disconnect switch. The 230 volt supply line to the unit must include a disconnect switch at or in sight of the unit, that may or may not be fused. This is in addition to the main fuse disconnect. Use correct wire and fuse sizes recommended for this heat pump. To insure adequate voltage at the unit, the supply wires must be of proper size. Minimum recommended wire and fuse sizes are listed on the data sheet packed with the heat pump. 2. Run 230 VAC line service wiring into control box through the bottom knock-out opening in the casing. (The two top knockouts are used when installing an auxiliary heater.) Attach supply wires to contactor as shown on wiring diagram. 3. Connect one supply wire to L1 on the contactor, and the other supply wire to L2 on the contactor. Connect ground wire to ground lug in control box. See Figure 8. FIGURE 8 LOW VOLTAGE 1. If the control wiring is to be routed through conduit that contains power conductors, the control wiring must be Class I and have suitable insulation. 2. Run low voltage control circuit wires through the fingered snap bushing to the low voltage terminal wire. Refer to Figure 9 diagram to connect the low voltage control wiring to the units low voltage connections. 3. If using auxiliary electric heat, refer to the wiring instructions provided with the heating kit. PKG. HEAT PUMP W1 or 66 CC W CorB XorL R Y BLOWER COIL O FIGURE 9 BLK PUR RED YEL ORG ORG YEL RED BLOCK-OFF PLATE DEFROST CONTROL BOARD TRANSFORMER CONTACTOR START RELAY (OPTIONAL) BLOWER DELAY (OPTIONAL) RUN CAPACITOR START CAPACITOR (OPTIONAL) PUR O G Y E R L X W2 B THERMOSTAT BLK 8 Unitary Products Group

WALL THERMOSTAT INSTALLATION 6. Make sure that there are no pipes or duct work in that part of the wall chosen for thermostat location. 7. Never locate it in a room that is warmer or cooler than the rest of the home, such as a kitchen or hallway. If installing this heat pump system in conjunction with a gas furnace, a baffle must be installed in the furnace to prevent cold air from being discharged around the heat exchanger. This could damage the heat exchanger and cause asphxiation. A sheet metal plate may be inserted in the supply outlet duct of the furnace to serve as a baffle. Advise the homeowner that the baffle plate must be removed before attempting to operate the interior furnace. A thermostat interlock system must be provided to prevent simultaneous operation of any furnace with the heat pump. If a furnace will be in the home, a separate furnace thermostat must be used and an interlock switch (See Figure 10) must be installed in both thermostat circuits, insuring only one thermostat can be operated at a time. This switch must break the control circuit of any furnace used. 8. The living or dining room are normally a good location provided there is no cooking range or refrigerator on the opposite side of wall. 9. Make final check of complete electrical system for correct wiring. Check for any possible loose connections. CHECK-OUT PRE-START PROCEDURE Before starting the heat pump, check the following: 1. The unit is properly located and level. 2. The duct work is properly sized, insulated, weather proofed and correctly spaced from combustible materials. 3. Air is free to flow to and from outdoor coil. 4. All wiring is correct, tight, and according to the wiring diagrams. COOLING THERMOSTAT HEATING THERMOSTAT 5. The unit is properly grounded electrically. 6. The condensate drain is connected and directed away from unit and structure. 7. The outdoor fan and indoor blower wheel will turn freely. 8. The indoor blower is factory wired to provide the correct speed. TO AIR CONDITIONER CONTROL CIRCUIT FIGURE 10 DOUBLE POLE DOUBLE THROW SWITCH TO FURNACE CONTROL CIRCUIT The proper location of the room thermostat is most important to insure that it will provide a comfortable home temperature. Observe the following general rules when selecting a location: 1. Locate thermostat about 5 feet above floor. 2. Install on a partitioning wall, not on an outside wall. 3. Never expose it to direct light from lamps, sun, fireplaces, etc. 4. Avoid locations close to doors that lead outside, to windows or to adjoining outside walls. 5. Avoid locations close to radiators, warm air registers, or in the direct path of heat or cold air from them. SYSTEM START-UP, CHECK-OUT 1. Insure that all access doors are in position. The wall thermostat system switch should be in the OFF position, the fan switch in the AUTO position and the emergency heat switch in the NORM position. 2. The electrical power supply to the heat pump should be on for 12 hours and the compressor crankcase heater (if provided) is working. 3. Set the wall thermostat fan switch to ON. The outdoor blower should run. 4. Set wall thermostat fan switch to AUTO. The indoor blower should not run. 5. Set the wall thermostat system switch to COOL and the temperature selection lever below the room temperature. The heat pump should be running in the cooling mode. 6. Set the wall thermostat system switch to the HEAT position. The heat pump should stop. 7. Raise the wall thermostat temperature selection lever to a setting above the room temperature. The heat pump should now run in the heating mode. Unitary Products Group 9

8. To check the emergency heat operation, set the wall thermostat system switch to EMERGENCY HEAT. Raise the wall thermostat temperature selection lever high enough to close the second stage of the thermostat, if it is not already closed. The indoor blower will turn on when the heating elements stage on. If accessory heaters are not installed, the blower will not run. 9. Set the wall thermostat to the seasonal mode of operation (heat or cool), adjust the temperature selection lever to the desired setting. Record the following information for your service records after the heat pump has run for 20 minutes: Operating Mode Discharge Pressure Suction Pressure Suction Line Temp. at Compressor Indoor Dry Bulb Temperature Indoor Wet Bulb Temperature Outdoor Dry Bulb Temperature Outdoor Wet Bulb Temperature Voltage at Contactor Current at Contactor Model Number Serial Number Owner Date 10. Reinstall all panels on the heat pump. 11. Check the heat pump system for tubing and sheet metal rattles. 12. Instruct the owner on the operation and maintenance of this heat pump system. 13. Give the Customer Envelope to the owner and explain why the registration card should be filled out and returned. OTHER FEATURES INCORPORATED IN THE CONTROL Anti-Short Cycle time Delay Five minute duration, activated each time the indoor thermostat opens and each time the system is turned on. This delay may be reduced by a ratio of 256:1 by shorting the TEST" posts. Safety Lock-Out This device opens the circuit to the compressor contactor in response to either the High Pressure Limit or the High Temperature Limit switches opening. The compressor will remain off, even though the limit switches close and will start up only when the Lock-out is reset. The Lock-out also lights the Emergency Heat Indicator. To reset the Lock-out momentarily turn the thermostat to OFF" then back to its original position. The unit will start up after the 5 minute delay, mentioned above. 10 Unitary Products Group

NOTES Unitary Products Group 11

NOTES Subject to change without notice. Printed in U.S.A. 035-16310-002 Rev. A (0804) Copyright by York International Corp. 2004. All rights reserved. Supersedes: 035-16310-001 Rev. A (0400) Unitary P.O. Wichita Product Box KS Group 19014 67204-9014