W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA Gravity Probe B Relativity Mission

Similar documents
GP-B P0321 Rev -2 December 5, 1997

ROTOR COATING WET BENCH OPERATING PROCEDURE

Model 3300 Technical Support and Installation Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Public Safety DAS Annunciator Panel

Technical Specification PILATUS 100K Detector System

Victoreen Primalert 35 Area Radiation Monitor

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

Rev B, 9/2/2009. Kodiak Chiller Overview

Temperature Sensors & Compression Seal Fittings

818 Series Low-Power Detectors

4100U City and Relay Cards Installation Instructions

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Analog Input Module IC670ALG630

MicroMED: the Dust Particle Analyser of the ExoMars 2020 Dust Suite

Variable Temperature Microprobe Systems

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

ProStar 325 UV-Vis Detector

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

DIAGNOSTIC GUIDE DIAGNOSTIC TEST DISPLAY FAULT/ERROR CODES IMPORTANT. Activating the Diagnostic Test Mode. Before servicing, check the following:

Parameterisable compact fault annunciator with permanent display

Physics Requirements for the CXI Detector Stage

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

Spectrum Detector, Inc.

Frequently asked questions: Intelligent Transmitter Series

OVEN INDUSTRIES, INC.

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

/9308 External Battery Chargers Installation Instructions

Controllers. Instruction Manual WARNING

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Alpha Analyst. Integrated Alpha Spectrometer. Radiation Safety. Amplified.

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Power Flame Incorporated

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Module Features are-configurable, no module jumpers to set

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Mark 25 Ultrapure Water Conductivity Analyzer

Mechanical Heat Pump R515

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

20 Light Remote Annunciator

Indium Gallium Arsenide Detectors

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Technical Manual Ionisation Chamber MUSIC80

OPERATION MANUAL MODEL & ACCELEROMETER

Instruction Manual WARNING

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

STATION 200 THERMAL TEST

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

MicroSL Silicon Photomultiplier Detectors

Doc. No. SP R0. CXI Detector stage. Prepared by: Signature Date Jean-Charles Castagna Design Engineer

STEAMPRO. Steam Generator Troubleshooting and Service Guide

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Dry Contact Probe DCP (#30008)

SCR100 User Manual. Version:1.1 Date:Dec 2009

PUV, PIR and PFO Series BROCHURE

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

SEL Arc-Flash Solutions

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Dual-Diode Dosimeter Patient Dose Monitor

DIAGNOSTIC GUIDE DISPLAY FAULT/ERROR CODES E1 THERMISTOR OPEN IMPORTANT. Activating the Diagnostic Test Mode. Test Mode Functionality

SEL Arc-Flash Solutions

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

NIDS Dust sensor ED-N-DS-1408

Installation Instructions Model DLC

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

FlameGard 5 UV/IR HART

A Novel Approach for the Thermal Management. of PC Power Supply

Sensor Interface Module Installation/Operation Instructions

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

SEC Signature Process Gas Analyzer

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Model 1062 Environment Monitor

Model gffoz Process Ozone Sensor (In-Line)

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

INTRODUCTION / TABLE OF CONTENTS

sglux UV-SENSOR PROBES Catalogue

Tower & Obstruction Lighting Controls

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

An introduction to... Sigma

Saintech Ion Beam Systems - Ion Current Monitor

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Norcold Instillation Instructions ARP Yahoo Group DRAFT Norcold General Installation Instructions

Transcription:

W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission UV CHARGE CONTROL COMMISSIONING PROCEDURE FOR SM GYROSCOPES GP-B P0203 Rev -B July 26, 1998 ECO #831 Prepared by: Bruce Clarke Date Engineer Approved by: Yueming Xiao Date Manager, Gyroscope Commissioning Approved by: Sasha Buchman Date Manager, Gyroscope Development Approved by: B. Taller Date Quality Assurance Approved by: J. Turneaure Date Hardware Manager

UV CHARGE CONTROL COMMISSIONING PROCEDURE FOR SM GYROSCOPES This procedure is to be performed only by persons listed as certified operators of the gyroscope acceptance facilities. ESD precautions: Follow accepted ESD procedures. OVERVIEW Due to the extremely small currents possible through UV photoemmission (~ -100 to +10 fa), noise considerations limit performance testing to un-levitated gyroscopes. Net currents to and from the rotor are determined by measuring the current between the ground plane and local ground using an electrometer. The UV fixture is biased with either + 3 VDC, 0 VDC or - 3 VDC to control the net flow of charge. Equipment needed: (1) Keithly 6512 (or 617) Programmable Electrometer (1) Keithly 485 Autoranging Picoammeter (1) HP E3620A 0-25 V Dual Channel DC Power Supply (1) JeLite UV source w/power supply or Resonance Ltd. GP-B STU Lamp w/ 30VDC power supply (2) Resonance Ltd. Cs-Te photodiode (can use only one photo diode if two are not available) (1) PC w/ieee and A/D breakout box running Strawberry Tree data acquisition routine (2) Fiber optic jumpers. One SMA to SMA, one SMA to LEMO. (2) DiCon fiber optic on/off or 1x2 switch. One with LEMO connectors, one with SMA connectors. (Note: Section A applies to Room Temperature Commissioning Section B applies to Low Temperature Commissioning Acceptance Testing) A. Procedures for measurement of photocurrent in RT3 and RT4 2

Section AI must be performed prior to installation of the gyroscope in the vacuum can. It is not necessary to calibrate the system at each gyro installation as the system calibration is independent of any particular gyroscope however, the system calibration should be checked (re-calibrated) on a regular basis. AI - Couple UV source into vacuum can and calibrate the UV feed-throughs This sub-section verifies the optical paths from the UV source to the gyro and calibrates the UV power at the UV fixture relative to the UV power at the optical feedthrough. AI-1. There are three fiber optic SMA feed-throughs into the vacuum can. Determine which SMA feed through goes to which LEMO connector inside the can by shining a flashlight through the connector. Label these feed-throughs and the corresponding LEMO connectors in the system notebook as A, B and C. Clean all SMA connectors with ethyl alcohol and dry with a lint free wipe. AI-2. Power on the lamp and allow to warm for 20 minutes. AI-3. Couple the UV source (typically JeLite UV lamp or STU lamp) to the Cs-Te photodiode. AI-4. Bias the diode with -25VDC (BNC connector labeled G). AI-5. Connect the readout of the diode (BNC connector labeled R) to a picoammeter. The reading from this diode will represent UV power at the feedthrough. Record this value in Table I. AII-1. Connect a LEMO to SMA fiber jumper to the LEMO connector labeled A which is mounted on the gyro support structure. AII-2. Disconnect the Cs-Te photodiode from the UV source and connect to the SMA end of the SMA-LEMO jumper on the gyro support structure. Connect UV source to fiber feedthrough A. The reading from the diode represents the UV power at the fixture. Record this value in Table I. AI-1. Repeat I-3 through I-7 twice more for a total of three feed-through vs fixture power measurements for optical path A. AI-2. Repeat I-3 through II-8 for optical path B. AI-3. Repeat I-3 through II-8 for optical path C. The gyro may now be installed in the vacuum can. The fixtures will be identified by the label of the optical path connected to them as well as their location in the gyro housing ( on scribe or off scribe ). Choose the two optical paths with the least loss from feedthrough to fixture (see Table I - UV Feedthrough Calibration) to source the two UV fixtures in the gyro. Note the optical path and bias pin out for each fixture in the system notebook and in Table I. Ring both the bias connections and the ground plane connection and fill out the appropriate sections in table I. 3

AII - Measure UV Photocurrent The current from the gyro due to UV photoemmission is determined by comparing an average light on reading on the electrometer to an average light off reading. Figure 1 shows schematically the electronic set-up for measuring UV charge transfer. The electrometer and picoammeter are read over the IEEE bus. The fixture bias voltage is adjusted manually using the DC power supply. The averaging of the electrometer readings (and the optical switch actuation, if used) are automatically controlled using a PC and Strawberry Tree data acquisition software. In Figure 1, a (-) current represents electron flow from the onto the rotor from the fixture, a (+) current represents electron flow from the rotor to the fixture. In order to reduce noise to a minimum, special care should be paid to the grounding and shielding scheme as shown in Figure 1. Elimination of noise sources in the room temperature clean room (such as blower motors, static bars, etc.) will help ensure a low noise environment. Noise levels of 3 to 5 fa have been achieved using the set-up described in this procedure. Two data files may be generated by the data acquisition software: (1) averaged currents and (2) continuous current. Both of these schemes employ the fiber optic switch. Averaged currents With the optical switch open, electrometer readings are collected at a rate of 1 Hz (after a period of 1 data delay) and summed for a period of 1 averaging time. This value is then divided by averaging time - data delay to give an average current measured in the light off situation. The optical switch is then closed and an average current is determined for the light on situation in the same manner. The difference between these two averages is the current due to the UV light. The averaging time and data delay may be adjusted to give an acceptable error in the measurements. At least 20 ON/OFF cycles will generally need to be collected to obtain a good average of the net current. Software parameters: averaging time data delay typically between 2 minutes and 30 minutes typically 10% of the averaging time (10 s minimum) file format: 4

date time lamp off (fa) lamp on (fa) net curr (fa) lamp monitor (na) Continuous currents If there is considerable drift in the current and/or the signal to noise ratio is very small (i.e. on the order of unity) it may be difficult to obtain a reliable value using the averaged currents method. The data acquisition routine can also save a continuous record of the electrometer readings. This continuous record may then be reviewed as a strip chart and an average UV photocurrent value may be obtained. Software parameters: averaging time data delay sampling rate sets ON/OFF cycle, as above N/A electrometer sampling rate (typically 1 Hz) file format: date time current from ground plane (fa) It is also possible to make a UV current measurement using simply a strip chart and adjusting the bias on the fly to +3, 0 and -3 V. A baseline is generated in the same manner with the UV source off. This method has proven reliable if the drift in the currents readings (directly measurable with the lamp off) is small compared to the UV photocurrent. There is a Strawberry Tree routine available to generate such a strip chart, STRIP.WBB. Strawberry Tree Data Acquisition Files UVTEST.WWB no lamp monitor (IEEE reading of picoammeter) UVTEST2.WWB includes lamp monitor STRIP.WBB includes both electrometer and lamp monitor AII-1. Set-up electronics for monitoring UV current per Figure 1. Note that the PC and Strawberry Tree breakout box should be located outside the clean room, the DC power supply should be located in the gowning room (to be able to make adjustments without entering the clean room) and the electrometer, picoammeter, lamp, Cs-Te detector and optical switch should all be located inside the clean room. The electrometer and DC power supply should be powered on a separate AC circuit from the rest of the components (namely, the power supply for the UV lamp). Furthermore, there must be no suspension lines hooked up to the vacuum can as they can act as antennae and couple noise into the system. 5

AII-2. Calibrate the lamp monitor by measuring the UV power at the feedthrough relative to the lamp monitor reading using the Cs-Te diode. A series of three readings should be made. Record these in Table 3. AII-3. If optical switch is used, connect the switch output (SMA) to fiber A (SMA) with a Teflon alignment sleeve or barrel connector with alignment sleeve built-in. Otherwise directly couple the UV source to fiber A. (Here I will call the two fixtures (fibers) used A and B but it is possible that optical path C could be used, in which case the label C would be substituted for the unused fiber A or B). AII-4. Power down the noise sources (clean room blowers, ion gauge, static bar, air conditioning, lights and any computer monitors located inside the clean room). Log the time each system is powered down in Table 2 - Clean Room System Power Log. There shall be no entry to the clean room with the blowers off until 15 minutes after the blowers have been turned back on. Note that the AC power to the clean room blowers and air conditioning system is accessed from a circuit breaker box outside the clean room. It may be necessary to power down static bars, blowers and air conditioning in the clean room adjacent to the one where testing is being conducted. AII-5. Adjust the fixture bias to -3 VDC. Start the Strawberry Tree data acquisition routine UVTEST.WBB (or UVSTRIP.WBB for strip chart data acquisition) and adjust the averaging time and data delay to give the cleanest signal. Input an averaged current and continuous current filename and begin logging data. Record these filenames and software parameters in Table 3 - UV Current Measurement File Log. AII-6. Repeat III-5 with bias set to 0 VDC. AII-7. Repeat III-4 with bias set to +3 VDC. AII-8. Adjust fixture bias to -3 VDC. Turn lamp power off (must be done without entering clean room). Start Strawberry Tree Routine UVTEST2.WBB (omits lamp monitor). Collect data as in III-4. Update Table 3. AII-9. Repeat III-7 for 0 VDC fixture bias. AII-10. Repeat III-7 for +3 VDC fixture bias. AII-11. Power on all clean room systems. Update Table 2. AII-12. After blowers and air conditioning have been on for 15 minutes, enter clean room and connect the optical switch output (or UV source directly) to fiber B. Repeat III-3 through III-10 for fiber B. AII-13. Disconnect UV electronics and optical circuit and remove from clean room. AII-14. Process raw data and complete table RT Op#2. 6

B. Procedures for measurement of photocurrent in LT system The procedures for measuring UV photocurrent at low temperature in the NLFF probe will follow the room temperature procedures as outlined in sections AI through AIII above, omitting system dependent references (i.e. al references to clean room, RT#, clean room systems, blowers, etc.). The experimental set-up will closely follow that shown for the RT system in Figure 1. Table 1 - UV Feedthrough Calibration as well as Table LT -Op #6 - UV Current Measurements will be completed for each gyroscope installation. Section BI must be performed prior to installation of the gyroscope in the vacuum can. BI - Couple UV source into vacuum can and calibrate the UV feedthrough This sub-section verifies the optical paths from the UV source to the gyro and calibrates the UV power at the UV fixture relative to the UV power at the optical feedthrough. This system calibration should be done on each gyroscope installation since thermal cycling may significantly change the properties of the fiber optics. BI-1. There are three fiber optic SMA feed-throughs into the vacuum can. Determine which LEMO feed-through goes to which LEMO connector inside the can by shining a flashlight through the connector. Label these feed-throughs and the corresponding LEMO connectors in the system notebook as A, B and C. Clean all LEMO connectors with ethyl alcohol and dry with a lint free wipe. BI-2. Power on the lamp and allow to warm for 20 minutes. BI-3. Couple the UV source (typically JeLite UV lamp or STU lamp) to the Cs-Te photodiode. BI-4. Bias the diode with -25VDC (BNC connector labeled G). BI-5. Connect the readout of the diode (BNC connector labeled R) to a picoammeter. The reading from this diode will represent UV power at the feedthrough. Record this value in Table I. BI-6. Connect a LEMO to SMA fiber jumper to the LEMO connector labeled A which is mounted on the gyro support structure. BI-7. Disconnect the Cs-Te photodiode from the UV source and connect to the SMA end of the SMA-LEMO jumper on the gyro support structure. Connect UV source to fiber feedthrough A. The reading from the diode represents the UV power at the fixture. Record this value in Table I. BI-8. Repeat I-3 through I-7 twice more for a total of three feed-through vs fixture power measurements for optical path A. BI-9. Repeat I-3 through II-8 for optical path B. BI-10. Repeat I-3 through II-8 for optical path C. 7

The gyro may now be installed in the vacuum can. The fixtures will be identified by the label of the optical path connected to them as well as their location in the gyro housing ( on scribe or off scribe ). Choose the optical paths with the least loss from feedthrough to fixture (see Table I - UV Feedthrough Calibration). Note the optical path and bias pin out for each fixture in the system notebook. Ring both the bias connections and the ground plane connection and fill out the appropriate section in table I. BII - Measure UV Photocurrent BII-1. Set-up electronics for monitoring UV current per Figure 1. BII-2. If optical switch is used, connect the switch output (LEMO) to fiber A (LEMO). Otherwise directly couple the UV source to fiber A. (Here I will call the two fixtures (fibers) used A and B but it is possible that optical path C could be used, in which case the label C would be substituted for the unused fiber A or B). BII-3. Start the Strawberry Tree data acquisition routine UVTEST.WBB. (Note; if automatic bias control is used (AUTOUV.WBB) steps BII-4 through BII-9 are handled by the data acquisition system) Adjust the fixture bias to -3 VDC. Adjust the averaging time and data delay to give the cleanest signal. Input an averaged current and continuous current filename and begin logging data. Record in Logbook the filenames and Table 3 parameters BII-4. Repeat BII-3 with bias set to 0 VDC. BII-5. Repeat BII-3 with bias set to +3 VDC. BII-6. Adjust fixture bias to -3 VDC. Turn lamp power off. Start Strawberry Tree Routine UVTEST2.WBB (omits lamp monitor). Collect data as in BII-4. Update Table 3. BII-7. Repeat BII-6 for 0 VDC fixture bias. BII-8. Repeat BII-6 for +3 VDC fixture bias. BII-9. Power on all clean room systems. Update Table 2. BII-10. Connect the optical switch output (or UV source directly) to fiber B. Repeat BII- 2 through BII-9 as required for fiber B. BII-11. Calibrate the lamp monitor by measuring the UV power at the feedthrough relative to the lamp monitor reading using the Cs-Te diode. A series of three readings should be made. Record these in Table 3. BII-12. Process raw data and complete table LT Op#6. Analysis of Results yielding noise greater than the expected signal may require, at REE s discretion, steps BII-3 through BII-8 to be run to reduce the noise source. 8

TABLE 1 - UV FEED-THROUGH CALIBRATION AND CHECK-OUT Date: System: Cs-Te detector used at fixture: na/uw S/N Cs-Te detector used at UV source: na/uw S/N Keithly 6512 (or 617) Electrometer S/N Keithly 485 Picoammeter S/N HP E3620A DC power supply S/N optical path A diode reading at fixture (na) diode reading at feedthru (na) UV power at fixture (uw) UV power at feedthru (uw) ratio (fixture/ feedthru) avg ratio B C fixture location in housing optical path bias pin bias pin to fixture resistance (Ohms) bias pin to GP capacitance (pf) Ground plane connection out : Ground plane connection center pin to shield resistance: COMMENTS : 9

TABLE 2 - CLEAN ROOM SYSTEM POWER LOG Date: Clean room used: RT# Fixture under test: A B C System Time Off Time On Comment Static bar Ion gauge Lights Air conditioning Blowers *** ABSOLUTELY NO ENTRY TO CLEAN ROOM ALLOWED UNTIL BLOWERS HAVE BEEN ON FOR 15 MINUTES. Date: Clean Room used: RT# Fixture under test: A B C System Time Off Time On Comment Static bar Ion gauge Lights Air conditioning Blowers *** ABSOLUTELY NO ENTRY TO CLEAN ROOM ALLOWED UNTIL BLOWERS HAVE BEEN ON FOR 15 MINUTES. 10

TABLE 3 - UV CURRENT MEASUREMENT FILE LOG Date: System: Gyro housing: Rotor: Test # Resonance Cs-Te photodiode: S/N ( na/uw) Keithly 6512 (or 617) Electrometer S/N Keithly 485 Picoammeter S/N HP E3620A DC power supply S/N MONITOR CALIBRATION UV monitor UV @ feedthrough (na) (na) ratio (feedthru/monitor) average ratio RAW DATA FILES Fixture A B C S/N: Location in housing: on scribe / off scribe Fixture Lamp data filename Comment bias (V) (on/off) + 3 on 0 on - 3 on + 3 OFF 0 OFF - 3 OFF Fixture A B C S/N: Location in housing: on scribe / off scribe Fixture Lamp data filename Comment bias (V) (on/off) + 3 on 0 on - 3 on + 3 OFF 0 OFF - 3 OFF 11

ROOM TEMPERATURE UV CURRENT MEASUREMENTS Table RT -Op #2 Date: System: Gyro housing: Rotor: Test # Reduced data and summary filenames: ( + ) current = electron flow from the rotor to the fixture ( - ) current = electron flow from the fixture onto the rotor Fixture Bias (V) net current (fa) normalized net current (fa/uw) spec (fa/uw) A B C + 3 > 10 s/n 0 N/A scribe on/off - 3 > -30 A B C + 3 > 10 s/n 0 N/A scribe on/off - 3 > -30 pass /fail NULL CHECK - LAMP OFF Fixture Bias (V) current (fa) comment A B C +3 0-3 A B C + 3 0-3 Completed by: Witnessed by: on on 12

LOW TEMPERATURE UV CURRENT MEASUREMENTS Table LT -Op #6 Date: System: Gyro housing: Rotor: Test # Reduced data and summary filenames: ( + ) current = electron flow from the rotor to the fixture ( - ) current = electron flow from the fixture onto the rotor Fixture Bias (V) net current (fa) normalized net current (fa/uw) spec (fa/uw) A B C + 3 > 10 s/n 0 N/A scribe on/off - 3 > -30 A B C + 3 > 10 s/n 0 N/A scribe on/off - 3 > -30 pass /fail NULL CHECK - LAMP OFF Fixture Bias (V) current (fa) comment A B C +3 0-3 A B C + 3 0-3 Completed by: Witnessed by: on on 13

FIGURE 1 - INSTRUMENTATION SET-UP FOR MEASUREMENT OF UV PHOTOCURRENT Faraday cage Fiber circuit Electrical conductors DC power supply ground + - SMA-SMA Teflon sleeve fiber optic switch** vacuum can fiber feed thru LEMO UV source SMA SMA UV fixture SMA Cs-Te photodiode electrometer N/C on shield junction box gyro tri-axial connector insulated HV feed-thru picoammeter -5 to -25 VDC diode bias ** optional element in optical path. Source may be coupled directly to fiber feedthrough 14