MEASUREMENT AND TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-60 IP-PBX This Report Concerns: Original Report Equipment Type: IP PBX Test Engineer: Safety Engineer: Eric Ding Reviewed By: Team Leader: Robin He Report No.: R2XM180207050-10M1 Revised note: Issue Date: 2018-04-11 Test Date: 2018-04-01 Regulation: COMMISSION REGULATION (EC) No 1275/2008 in conjunction with COMMISSION REGULATION (EU) No 801/2013 Test Methods: EN 50564:2011 Conclusion: Prepared By: This product complies with COMMISSION REGULATION (EC) No 1275/2008 and COMMISSION REGULATION (EU) No 801/2013. Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China The Test Results relate only to the sample tested. The test report shall not be reproduced except in full, without the written approval of Bay Area Compliance Laboratories Corp. (Dongguan)
TABLE OF CONTENTS 1 - APPLICANT AND FACTORY INFORMATION... 3 2 - GENERAL PRODUCT INFORMATION... 3 3 - TEST SET UP CONFIGURATION... 5 4 - TEST EQUIPMENT LIST AND DETAILS... 6 5 - SUMMARY OF TEST RESULT... 7 6 - APPENDIX A EUT PHOTOS... 8 Report # R2XM180207050-10M1 Page 2 of 9 EN 50564 Test Report
1 - Applicant and factory Information A. 1 applicant Company Name Address: A. 2 factory Company Name Address: United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT 2 - General Product Information Product Characteristics Items EUT Input Rating Sample No. Brand name Model identification Model difference Version or serial number Additional information Input voltage: Input current: Input frequency: Sample 1 Sample 2 Sample 3 Contents: 100-240Vac 0.5A Max. 50/60Hz XT-60 IP-PBX XonTel XT-60 IP-PBX Remark: This report is based on and replaced the BACL report No.: R2XM180207050-10, the only difference is changed the applicant's and manufacturer's name to " United GULF GATE Co. " and the address be changed to " Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT ". Others are the same, no need add test. Report # R2XM180207050-10M1 Page 3 of 9 EN 50564 Test Report
PSU Information and test voltage Power type Power supply unit Test Voltage Manufacture Type Input Output Note Efficiency Level 230Vac, 50Hz 115Vac, 60Hz 100Vac, 50Hz 100Vac, 60Hz 220Vac, 50Hz fluctuation 0.5% Harmonic (up to and including 13 th harmonic) crest factor Apply to sample(s) test. Didn't apply to sample(s) test. Didn't apply to sample(s) test. Didn't apply to sample(s) test. Didn't apply to sample(s) test. 2% Supply Voltage accuracy (V) 1% Test room Selectable for 3 or 6 ( 3) for difference range. wattmeter 0.5% resolution 0.00001W( 10W),0.001W(10W W 100W),0.01W(>100W) Frequency reponse of Power Meter 100kHz Temperature( C) 24.4 Humidity(%) 49.8 illuminance(lx) >300lx Air speed(m/s) 0.1 Level of confidence at: 95%, K=2 Uncertainty: Sequence of mode Off Standby Networked standby UC 2% (Power > 0.5 W) or 0.01W ( 0.5W) Yes Yes Report # R2XM180207050-10M1 Page 4 of 9 EN 50564 Test Report
3 - Test set up Configuration Report # R2XM180207050-10M1 Page 5 of 9 EN 50564 Test Report
4 - Test Equipment List and Details Manufacturer Description Model Serial Number Last Cal. Date Next Cal. Date YOKOGAWA WT210 Power meter 760401 91GC34404 2018-03-26 2019-03-26 HP AC power supply HPA1103 2017-05-05 2018-05-05 Victor Hygrothermograph HTC-1 2018-03-17 2019-03-17 Testo Anemometer 405-V1 41513556/311 2017-07-17 2018-07-17 Note: The test equipment list above is calibrated annually. Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) at tests that all calibration has been performed using suitable standards traceable to the National Primary Standards and International System of Units (SI). Report # R2XM180207050-10M1 Page 6 of 9 EN 50564 Test Report
5 - SUMMARY OF TEST RESULT HiNA equipment Sample No Vac, Hz Test result (Networked Standby mode) Limit (As of 1 January 2017) Sample 1 230Vac, 50Hz 3.5W 8.0W Sample No Vac, Hz Test result (Off mode) Limit (effective date: 7 th January, 2013) Sample 1 230Vac, 50Hz 0W 0.5W Sample No Vac, Hz Test result (Standby mode) Limit (effective date: 7 th January, 2013) Sample 1 Report # R2XM180207050-10M1 Page 7 of 9 EN 50564 Test Report
6 - Appendix A EUT photos 6.1 EUT Photo- top view 6.2 EUT Photo- bottom view Report # R2XM180207050-10M1 Page 8 of 9 EN 50564 Test Report
6.3 EUT Photo- front view 6.3 EUT Photo- back view ***END OF REPORT*** Report # R2XM180207050-10M1 Page 9 of 9 EN 50564 Test Report