MEASUREMENT AND TEST REPORT

Similar documents
EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

Test Report. Appliance EMF Testing

Copy of marking plate:

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 55R80 FCC ID:W8U55R80

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 32R20 FCC ID:W8U32R20

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

Refrigerating Appliance DOE Test Report

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

DELTA Classification Report

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

P R O D U C T D ATA S H E E T

Technical-Report for SL Lamp 5 W

CERTIFICATE. Issued Date: Dec. 23, 2010 Report No.: 10C142R-ITCEP7V05

ARGUS APPLICATION 9V937-A01C

WYLE LABORATORIES, INC. Huntsville Facility

NATIONAL TECHNICAL SYSTEMS

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

FCC PART 22H, PART 24E FCC PART 27 MEASUREMENT AND TEST REPORT. Smartisan Technology Co., Ltd.

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

ViscoClock plus AUTOMATIC VISCOSITY MEASUREMENT EASY AND PRECISE

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

WH-1404, Rev. Feb 97

Refrigerating Appliance ErP Test Report

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE. Issued Date: Apr. 16, 2014 Report No. : R-ITCEP11V04

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

EU Declaration of Conformity

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

Test Report to AS/NZS :2015. Report No. T160402_S

PQS Independent type-testing protocol

FINAL REPORT ON THE 4 TH JOINT CROSS-BORDER EMC MARKET SURVEILLANCE CAMPAIGN (2011) LED LIGHTING PRODUCTS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

The test items passed the test specification(s).

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Sensor Systems Network Design and QA/QC Brian Stacey

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

LORAIN CIP 4890/48120 DC Power System

2604 Controller Melt Pressure Controller

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

WASTEWATER Online UV%Transmission Analyzer

In Situ Temperature Measurement

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

AUGUST 2016 CONTENTS:

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)

Door Release Power Supply

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

CE marking & your legal obligations

Airworthiness Directive

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Laser Distance Sensor Type M Analog-Output

Vibration tests on a TNAML Luminaire

Stand Alone DYNAGARD SP Operation Manual

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

CALIBRATION HOW IT WORKS

ULT Freezer Performance Testing Emerson Design Services Network Project #

Mark 25 Ultrapure Water Conductivity Analyzer

Air Purifier Test Report (Brand: "Plasma Air" Bipolar Ionization Air Purifier - Model: 102C) Our Reference No.: 08/1253/RL/RC/001

PQS performance specification

EU-Type Examination Certificate

SEAR II APPLICATION 9V899-A01D PREPARED FOR NICTD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

PQS performance specification

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

P R O D U C T D ATA S H E E T

2704 Controller Melt Pressure Controller

No. KM First Issued: 23/03/1998 Latest Issue: 11/08/2010 Page 5 of 9

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Test Report issued under the responsibility of:

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

BD Viper Lysing Heater Manual (for BD Viper System)

MICROFAN B.V. Industriestraat PH Horst P.O. Box AA Horst Developing, manufacturing and marketing of MICROFAN

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Good Practice Guide GPG

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

PQS Independent type-testing protocol

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Page 2 of 5. SOP SF SOP for Water Bath Maintenance

Cooper Lighting & Safety Limited Wheatley Hall Road, Doncaster, DN2 4NB, United Kingdom

LORAIN CSP DC Power System

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Transcription:

MEASUREMENT AND TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-60 IP-PBX This Report Concerns: Original Report Equipment Type: IP PBX Test Engineer: Safety Engineer: Eric Ding Reviewed By: Team Leader: Robin He Report No.: R2XM180207050-10M1 Revised note: Issue Date: 2018-04-11 Test Date: 2018-04-01 Regulation: COMMISSION REGULATION (EC) No 1275/2008 in conjunction with COMMISSION REGULATION (EU) No 801/2013 Test Methods: EN 50564:2011 Conclusion: Prepared By: This product complies with COMMISSION REGULATION (EC) No 1275/2008 and COMMISSION REGULATION (EU) No 801/2013. Bay Area Compliance Laboratories Corp. (Dongguan) No.69, Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China The Test Results relate only to the sample tested. The test report shall not be reproduced except in full, without the written approval of Bay Area Compliance Laboratories Corp. (Dongguan)

TABLE OF CONTENTS 1 - APPLICANT AND FACTORY INFORMATION... 3 2 - GENERAL PRODUCT INFORMATION... 3 3 - TEST SET UP CONFIGURATION... 5 4 - TEST EQUIPMENT LIST AND DETAILS... 6 5 - SUMMARY OF TEST RESULT... 7 6 - APPENDIX A EUT PHOTOS... 8 Report # R2XM180207050-10M1 Page 2 of 9 EN 50564 Test Report

1 - Applicant and factory Information A. 1 applicant Company Name Address: A. 2 factory Company Name Address: United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT 2 - General Product Information Product Characteristics Items EUT Input Rating Sample No. Brand name Model identification Model difference Version or serial number Additional information Input voltage: Input current: Input frequency: Sample 1 Sample 2 Sample 3 Contents: 100-240Vac 0.5A Max. 50/60Hz XT-60 IP-PBX XonTel XT-60 IP-PBX Remark: This report is based on and replaced the BACL report No.: R2XM180207050-10, the only difference is changed the applicant's and manufacturer's name to " United GULF GATE Co. " and the address be changed to " Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT ". Others are the same, no need add test. Report # R2XM180207050-10M1 Page 3 of 9 EN 50564 Test Report

PSU Information and test voltage Power type Power supply unit Test Voltage Manufacture Type Input Output Note Efficiency Level 230Vac, 50Hz 115Vac, 60Hz 100Vac, 50Hz 100Vac, 60Hz 220Vac, 50Hz fluctuation 0.5% Harmonic (up to and including 13 th harmonic) crest factor Apply to sample(s) test. Didn't apply to sample(s) test. Didn't apply to sample(s) test. Didn't apply to sample(s) test. Didn't apply to sample(s) test. 2% Supply Voltage accuracy (V) 1% Test room Selectable for 3 or 6 ( 3) for difference range. wattmeter 0.5% resolution 0.00001W( 10W),0.001W(10W W 100W),0.01W(>100W) Frequency reponse of Power Meter 100kHz Temperature( C) 24.4 Humidity(%) 49.8 illuminance(lx) >300lx Air speed(m/s) 0.1 Level of confidence at: 95%, K=2 Uncertainty: Sequence of mode Off Standby Networked standby UC 2% (Power > 0.5 W) or 0.01W ( 0.5W) Yes Yes Report # R2XM180207050-10M1 Page 4 of 9 EN 50564 Test Report

3 - Test set up Configuration Report # R2XM180207050-10M1 Page 5 of 9 EN 50564 Test Report

4 - Test Equipment List and Details Manufacturer Description Model Serial Number Last Cal. Date Next Cal. Date YOKOGAWA WT210 Power meter 760401 91GC34404 2018-03-26 2019-03-26 HP AC power supply HPA1103 2017-05-05 2018-05-05 Victor Hygrothermograph HTC-1 2018-03-17 2019-03-17 Testo Anemometer 405-V1 41513556/311 2017-07-17 2018-07-17 Note: The test equipment list above is calibrated annually. Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) at tests that all calibration has been performed using suitable standards traceable to the National Primary Standards and International System of Units (SI). Report # R2XM180207050-10M1 Page 6 of 9 EN 50564 Test Report

5 - SUMMARY OF TEST RESULT HiNA equipment Sample No Vac, Hz Test result (Networked Standby mode) Limit (As of 1 January 2017) Sample 1 230Vac, 50Hz 3.5W 8.0W Sample No Vac, Hz Test result (Off mode) Limit (effective date: 7 th January, 2013) Sample 1 230Vac, 50Hz 0W 0.5W Sample No Vac, Hz Test result (Standby mode) Limit (effective date: 7 th January, 2013) Sample 1 Report # R2XM180207050-10M1 Page 7 of 9 EN 50564 Test Report

6 - Appendix A EUT photos 6.1 EUT Photo- top view 6.2 EUT Photo- bottom view Report # R2XM180207050-10M1 Page 8 of 9 EN 50564 Test Report

6.3 EUT Photo- front view 6.3 EUT Photo- back view ***END OF REPORT*** Report # R2XM180207050-10M1 Page 9 of 9 EN 50564 Test Report