Requirements for Electrical Installations

Similar documents
Requirements for Electrical Installations

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

Amendment Number 3 of BS how it might affect you

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Guide to: 17 th Edition Consumer Units

User Information Sheet 008 : 2010

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

Special Types of Installation

An overview of the main proposals in BS th Edition. Electrical Contractors Association

Requirements for Electrical Installations

Information Sheet LIA IS 07 Issue 1 08/2013 Page 1 of 5 For LIA members use only

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

UEE30811 Q-Tracker Work Tasks

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Electrical Safety Requirements

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

INTERNATIONAL STANDARD

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

WARNING SYMBOLS CHECKLIST (CRAFT)

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

Neil Hewitt Electrical & Air Conditioning P/L

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

ACMA mandated EMC standards

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

CHAPTER 20 SERVICE EQUIPMENT

Ackrediteringens omfattning / Scope of accreditation Components and installation

NEC 2017 Changes and Their Effect Upon the ICT Industry

INTERNATIONAL STANDARD

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

INTERNATIONAL STANDARD

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

GENERAL SPECIFICATION ELECTRICAL

INTERNATIONAL STANDARD

Electrisaver User and Installation Instructions

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ANCILLARY LIGHT CURRENT EQUIPMENT

Mauritian Standards/Amendments Published in 2013

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

BS Outcomes 6

Chapter 1 General... 5

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

C 271/32 Official Journal of the European Union

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

STANDARDS INSTALLATION. Certificate No 077m

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

UK Direction BS7671 BS 8492 BS /01/2018

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Alberta Municipal Affairs

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

(Notices) EUROPEAN COMMISSION

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

SEMPEO SQA Unit Code H02H 04 Wiring electrical equipment and circuits

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Lloyd s Register Type Approval System Test Specification Number 3

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

(Notices) EUROPEAN COMMISSION

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Total Fire Solutions. Includes BS 8519 and the updated BS :

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

INTERNATIONAL STANDARD

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas

INTERNATIONAL STANDARD

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

FIRE RESISTANT CABLES FP300

ORDINANCE NO

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

Electronic 7 Installation Instructions

09 ELECTRICAL 0902 Electrical

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

RE-PR3-E-27 3-Phase Panel Mount 27kW

Transcription:

BRITISH STANDARD BS 7671:2018 Corrigendum (December 2018) Requirements for Electrical Installations IET Wiring Regulations Eighteenth Edition The Institution of Engineering and Technology and BSI NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION

BS 7671:2018 - Corrigendum (December2018) Please note the following corrections TABLE OF CONTENTS (INCLUDING SUMMARY OF CORRECTIONS) No. Page Location Issue 1. 131 Chapter 51 Due to the publication of BS EN 60445 in 2017, which was between the cut-off date for new work and the publication date for BS 7671:2018, it s necessary to amend Table 51.1. In BS EN 60445:2017, the functional earthing conductor is identified by the colour pink. 2. 132 514.12.1 Label size in BS 7671:2018 is incorrect, align with BS 7671:2015+A3:2015 3. 133 514.12.2 Label size in BS 7671:2018 is incorrect, align with BS 7671:2015+A3:2015 4. 133 514.13.2 Label size in BS 7671:2018 is incorrect, align with BS 7671:2015+A3:2015 5. 133 514.14.1 Label size in BS 7671:2018 is incorrect, align with BS 7671:2015+A3:2015 6. 134 514.15.1 Label size in BS 7671:2018 is incorrect, align with BS 7671:2015+A3:2015 7. 244 Fig 701.2 f) Regulation 701.32.3 (ii) (b) states that Zone 1 is limited by the vertical service at a distance of 1.20 m from the centre point of the fixed water outlet on the wall or ceiling for showers without a basin (see Figure 701.1(e) and (f)). Therefore, Zone 2 as shown within this figure is an error. 8. 280 710.559 710.559 Luminaires and lighting installations In medical locations of Group 1 and Group 2, at least two different sources of supply shall be provided. One of the sources shall be connected to the electrical supply system for safety services. In medical locations of group 1 and group 2, a minimum of two lighting circuits shall be provided from separate sources of supply. At least one of the circuits shall be supplied from a system for safety services. The luminaires of the escape routes shall be arranged on alternative circuits, one of which shall be supplied from the power supply source for safety services. 9. 351 Appendix 1 BS EN 60947-2 should be referenced as 2017 and not as A2:2013 10. 373 Appendix 4 Last row of the table, 90 C thermoplastic insulated cables should be 'thermosetting'. 11. 423 Table 4F3A Glass fibre flexible cable, ambient temperature reads 35 to 50 C, should be 35 to 150 C, The corrections are shown with a red change bar on the following pages.

TABLE 51 Identification of conductors Function Alphanumeric Colour Protective conductors Functional earthing conductor Green-and-yellow Cream/Pink (5) AC power circuit (1) Line of single-phase circuit L Brown Neutral of single- or three-phase circuit N Blue Line 1 of three-phase AC circuit L1 Brown Line 2 of three-phase AC circuit L2 Black Line 3 of three-phase AC circuit L3 Grey Two-wire unearthed DC power circuit Positive of two-wire circuit L+ Brown Negative of two-wire circuit L- Grey Two-wire earthed DC power circuit Positive (of negative earthed) circuit L+ Brown Negative (of negative earthed) circuit (2) M Blue Positive (of positive earthed) circuit (2) M Blue Negative (of positive earthed) circuit L- Grey Three-wire DC power circuit Outer positive of two-wire circuit derived from L+ Brown three-wire system Outer negative of two-wire circuit derived from L- Grey three-wire system Positive of three-wire circuit L+ Brown Mid-wire of three-wire circuit (2)(3) M Blue Negative of three-wire circuit L- Grey Control circuits, ELV and other applications Line conductor L Brown, Black, Red, Orange, Yellow, Violet, Grey, White, Pink or Turquoise Neutral or mid-wire (4) N or M Blue NOTE: (1) Power circuits include lighting circuits. (2) M identifies either the mid-wire of a three-wire DC circuit, or the earthed conductor of a two-wire earthed DC circuit. (3) Only the middle wire of three-wire circuits may be earthed. (4) An earthed PELV conductor is blue. (5) BS EN 60445:2017 applies from 8th September 2020 131

514.7 Not used 514.8 Identification of a protective device 514.8.1 A protective device shall be arranged and identified so that the circuit protected may be easily recognized. 514.9 Diagrams and documentation 514.9.1 A legible diagram, chart or table or equivalent form of information shall be provided indicating in particular: (i) the type and composition of each circuit (points of utilization served, number and size of conductors, type of wiring), and (ii) the method used for compliance with Regulation 410.3.2, and (iii) the information necessary for the identification of each device performing the functions of protection, isolation and switching, and its location, and (iv) any circuit or equipment vulnerable to the electrical tests as required by Part 6. For simple installations the foregoing information may be given in a schedule. A durable copy of the schedule relating to a distribution board shall be provided within or adjacent to each distribution board. Any symbol used shall comply with IEC 60617. 514.10 Warning notice: voltage 514.10.1 Every item of equipment or enclosure within which a nominal voltage exceeding 230 volts to earth exists and where the presence of such a voltage would not normally be expected, shall be so arranged that before access is gained to a live part, a warning of the maximum voltage to earth present is clearly visible. 514.11 Warning notice: isolation 514.11.1 A notice of such durable material as to be likely to remain easily legible throughout the life of the installation shall be fixed in each position where there are live parts which are not capable of being isolated by a single device. The location of each disconnector (isolator) shall be indicated unless there is no possibility of confusion. 514.12 Notices: periodic inspection and testing 514.12.1 A notice of such durable material as to be likely to remain easily legible throughout the life of the installation shall be fixed in a prominent position at or near the origin of every installation upon completion of the work carried out in accordance with Chapter 64 or 65. The notice shall be inscribed in indelible characters not smaller than those illustrated here and shall read as follows: IMPORTANT This installation should be periodically inspected and tested and a report on its condition obtained, as prescribed in the IET Wiring Regulations BS 7671 Requirements for Electrical Installations. Date of last inspection... Recommended date of next inspection... 132

514.12.2 Where an installation incorporates an RCD a notice shall be fixed in a prominent position at or near each RCD in the installation. The notice shall be inscribed in indelible characters not smaller than those illustrated here and shall read as follows: This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test six-monthly by pressing the button marked T or Test. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice. NOTE: Testing frequencies of RCDs in temporary installations may need increasing. 514.13 Warning notices: earthing and bonding connections 514.13.1 A durable label to BS 951 with the words 'Safety Electrical Connection Do Not Remove' shall be permanently fixed in a visible position at or near: (i) the point of connection of every earthing conductor to an earth electrode, and (ii) the point of connection of every bonding conductor to an extraneous-conductive-part, and (iii) the main earthing terminal, where separate from main switchgear. 514.13.2 Where Regulation 418.2.5 or 418.3 applies, the warning notice specified shall be durably marked in legible type not smaller than that illustrated here and shall read as follows: The protective bonding conductors associated with the electrical installation in this location MUST NOT BE CONNECTED TO EARTH. Equipment having exposed-conductive-parts connected to earth must not be brought into this location. 514.14 Warning notice: non-standard colours 514.14.1 If wiring additions or alterations are made to an installation such that some of the wiring complies with Regulation 514.4 but there is also wiring to a previous version of these Regulations, a warning notice shall be affixed at or near the appropriate distribution board with the following wording: CAUTION This installation has wiring colours to two versions of BS 7671. Great care should be taken before undertaking extension, alteration or repair that all conductors are correctly identified. 133

514.15 Warning notice: alternative supplies 514.15.1 Where an installation includes alternative or additional sources of supply, warning notices shall be affixed at the following locations in the installation: (i) At the origin of the installation (ii) At the meter position, if remote from the origin (iii) At the consumer unit or distribution board to which the alternative or additional sources are connected (iv) At all points of isolation of all sources of supply. The warning notice shall be durably marked in legible type not smaller than that illustrated here and shall read as follows: WARNING MULTIPLE SUPPLIES Isolate all electrical supplies before carrying out work. Isolate the mains supply at... Isolate the alternative supplies at... 514.16 Notice: high protective conductor current See Regulation 543.7.1.205. 515 PREVENTION OF MUTUAL DETRIMENTAL INFLUENCE 515.1 Prevention of mutual detrimental influence Electrical equipment shall be selected and erected so as to avoid any harmful influence between the electrical installation and any non-electrical installations envisaged. NOTE: For EMC see Sections 332 and 444. 515.2 Where equipment carrying current of different types or at different voltages is grouped in a common assembly (such as a switchboard, a cubicle or a control desk or box), all the equipment belonging to any one type of current or any one voltage shall be effectively segregated wherever necessary to avoid mutual detrimental influence. The immunity levels of equipment shall be chosen taking into account the electromagnetic disturbances that can occur when connected and erected as for normal use, and taking into account the intended level of continuity of service necessary for the application. See the specific equipment standard or the relevant part of BS EN 61000 series. 134

Fig 701.2 Examples of zone dimensions (elevation) NOT TO SCALE (See Regulation 701.32 for definitions of zones) a) Bath tub Ceiling Window recess zone 2 zone 1 zone 2 2.25 m zone 0 * 0.60 m c) Shower basin Luminaire Recess above ceiling Ceiling zone 1 zone 2 2.25 m zone 0 * 0.60 m f) Shower without basin, but with permanent fixed partition Section x-x, see Fig 701.1f) Ceiling zone 1 zone 2 zone 1 2.25 m 0.10 m zone 0 zone 0 Permanent partition * Zone 1 if the space is accessible without the use of a tool. Spaces under the bath accessible only with the use of a tool are outside the zones. 244

710.559 Luminaires and lighting installations In medical locations of Group 1 and Group 2, at least two different sources of supply shall be provided. One of the sources shall be connected to the electrical supply system for safety services. In medical locations of group 1 and group 2, a minimum of two lighting circuits shall be provided from separate sources of supply. At least one of the circuits shall be supplied from a system for safety services. The luminaires of the escape routes shall be arranged on alternative circuits, one of which shall be supplied from the power supply source for safety services. 710.56 Safety services A power supply for safety services is required which will maintain the supply for continuous operation for a defined period within a pre-set changeover time. The safety power supply system shall automatically take over if the voltage of one or more incoming live conductors, at the main distribution board of the building, has dropped for more than 0.5 s and by more than 10 % in regard to the nominal voltage. NOTE: A list of examples with suggested reinstatement times is given in Table A710 of Annex A710. 710.560.4 Classification Classification of safety services is given in Regulation 560.4.1. NOTE: Safety services provided for locations having differing classifications should meet that classification which gives the highest security of supply. 710.560.5.5 General requirements for safety power supply sources of Group 1 and Group 2 Primary cells are not allowed as safety power sources. An additional main incoming power supply, from the general power supply, is not regarded as a source of the safety power supply. The availability (readiness for service) of safety power sources shall be monitored and indicated at a suitable location. 710.560.5.6 In case of a failure of the general power supply source, the power supply for safety services shall be energized to feed the equipment stated inregulations 710.560.6.1.1 to 3 with electrical energy for a defined period of time and within a predetermined changeover period. 710.560.5.7 Where socket-outlets are supplied from the safety power supply source they shall be readily identifiable according to their safety services classification. 710.560.6 Electrical sources for safety services 710.560.6.1 Detailed requirements for safety power supply services NOTE: Also refer to Regulation 710.560.5.5. 710.560.6.1.1 Power supply sources with a changeover period less than or equal to 0.5 s In the event of a voltage failure on one or more line conductors at the distribution board, a safety power supply source shall be used and be capable of providing power for a period of at least 3 h for the following: (i) Luminaires of operating theatre tables (ii) ME equipment containing light sources being essential for the application of the equipment, e.g. endoscopes, including associated essential equipment, e.g. monitors (iii) Life-supporting ME equipment. The duration of 3 h may be reduced to 1 h for items (ii) and (iii) if a power source meeting the requirements of Regulation 710.560.6.1.2 is installed. The normal power supply shall be restored within a changeover period not exceeding 0.5 s. NOTE: Supporting information relating to the autonomy of battery inverter units for theatre luminaires is given in HTM 06-01. 710.560.6.1.2 Power supply sources with a changeover period less than or equal to 15 s Equipment meeting the requirements of Regulations 710.560.9.1 and 710.560.11 shall be connected within 15 s to a safety power supply source capable of maintaining it for a minimum period of 24 h, when the voltage of one or more live conductors at the main distribution board for the safety services has decreased by more than 10 % of the nominal value of supply voltage and for a duration greater than 3 s. 280

BS or EN Number Title References BS EN 60947-2:2006 +A2:2013 BS EN 60947-2:2017 BS EN 60947-3:2009 +A2:2015 BS EN 60947-4- 1:2010+A1:2012 BS EN 60947-5-1:2004 +A1:2009 BS EN 60947-6- 1:2005+A1:2014 BS EN 60947-6-2:2003 Circuit-breakers 411.4.4 note 2 432.4 433.1.201 433.1.204 531.1.1 531.3.2(iv) 531.3.4.2 533.1.1 533.1.3 536.4.1.4 note 3 536.4.2.1 536.4.3.1 Table A53.1 711.410.3.4 721.415.1 722.531.2.101 722.533.101 740.410.3 740.411 note Appx 4 sec 4 Appx 8 sec 4 Switches, disconnectors, switch-disconnectors and fuse-combination units Contactors and motor starters Electromechanical contactor and motor starters. Control circuit devices and switching elements Electromechanical control circuit devices 536.4.2.3 536.4.2.3 note 536.4.3.2 537.4.1 Table A53.1 435.2 536.4.2.2 536.4.3.1 Multiple function equipment Transfer switching equipment 536.4.3.2 Table A53.1 710.537.1 Multiple function equipment Control and protective switching devices (or equipment) (CPS) Table A53.1 722.533.101 BS EN 60947-7 Specification for low-voltage switchgear and controlgear 526.2 note 1 BS EN 60947-7-1:2009 Ancillary equipment. Terminal blocks for copper conductors BS EN 60947-7-2:2009 Ancillary equipment. Protective conductor terminal blocks for copper conductors BS EN 60950-1:2006 Information technology equipment. Safety. General requirements 444.4.9 +A2:2013 BS EN 60974-9:2010 Arc welding equipment. Installation and use 706.1 BS EN 60998 Connecting devices for low-voltage circuits for household and similar purposes 526.2 note 1 559.5.4(i) BS EN 60998-2-1:2004 Particular requirements for connecting devices as separate entities with 715.521.107 screw-type clamping units BS EN 60998-2-2:2004 Particular requirements for connecting devices as separate entities with screwless-type clamping units 715.521.107 BS EN 61000 Electromagnetic compatibility (EMC) BS EN 61000 is a multiple part standard 515.2 Appx 4 sec 5.5.1 BS EN 61000-2 Electromagnetic compatibility (EMC). Environment Appx 5 AM BS EN 61000-4 Electromagnetic compatibility (EMC). Testing and measurement Appx 5 AM techniques BS EN 61000-6 Electromagnetic compatibility (EMC). Generic standards. Table A444.1(i) & (ii) 351

APPENDIX 4 (Informative) CURRENT-CARRYING CAPACITY AND VOLTAGE DROP FOR CABLES CONTENTS Tables: 4A1 Schedule of Installation Methods in relation to conductors and cables 4A2 Schedule of Installation Methods of cables (including Reference Methods) for determining current-carrying capacity 4A3 Schedule of cable specifications and current rating tables 4B1 Rating factors (Ca) for ambient air temperatures other than 30 C 4B2 Rating factors (Ca) for ambient ground temperatures other than 20 C 4B3 Rating factors (Cs) for soil resistivity, for cables buried direct or in underground conduit 4B4 Rating factors (Cd) for depths of laying other than 0.7 m for direct buried cables and cables in buried ducts 4B5 Rating factors for cables having more than 4 loaded cores 4C1 Rating factors (Cg) for one circuit or one multicore cable or for a group of circuits or multicore cables 4C2 Rating factors (Cg) for more than one circuit, cables buried directly in the ground 4C3 Rating factors (Cg) for more than one circuit, cables in ducts buried in the ground 4C4 Rating factors (Cg) for groups of more than one multicore cable on trays or cable ladders 4C5 Rating factors (Cg) for groups of one or more circuits of single-core cables on trays or cable ladders 4C6 Rating factors (Cg) for cables enclosed in infloor concrete troughs 4D1 Single-core non-armoured, with or without sheath 4D2 4D3 4D4 Multicore non-armoured Single-core armoured (non-magnetic armour) Multicore armoured 70 C thermoplastic insulated cables 4D5 Flat cable with protective conductor 4E1 Single-core non-armoured, with or without sheath 4E2 4E3 4E4 Multicore non-armoured Single-core armoured (non-magnetic armour) Multicore armoured 90 C thermosetting Copper conductors 4F1 60 C thermosetting insulated flexible cables 4F2 90 C and 180 C thermosetting insulated flexible cables Flexible cables 4F3 Flexible cables 4G1 4G2 Bare and exposed to touch, or having an overall thermoplastic covering Bare and neither exposed to touch nor in contact with combustible materials Mineral insulated cables 4H1 Single-core non-armoured, with or without sheath 4H2 4H3 Multicore non-armoured Single-core armoured (non-magnetic armour) 70 C thermoplastic insulated cables 4H4 4J1 Multicore armoured Single-core non-armoured, with or without sheath Aluminium conductors 4J2 4J3 4J4 Multicore non-armoured Single-core armoured (non-magnetic armour) Multicore armoured 90 C thermoplastic thermosetting insulated cables 373

COPPER CONDUCTORS TABLE 4F3A - Flexible cables, non-armoured (COPPER CONDUCTORS) CURRENT-CARRYING CAPACITY (amperes): and MASS SUPPORTABLE (kg): Conductor crosssectional area Current-carrying capacity Maximum mass supportable by twin flexible cable (see Single-phase AC Three-phase AC Regulations 522.7.2 and 559.5.2) 1 2 3 4 (mm 2 ) (A) (A) (kg) 0.5 3 3 2 0.75 6 6 3 1 10 10 5 1.25 13-5 1.5 16 16 5 2.5 25 20 5 4 32 25 5 Where cable is on a reel see the notes to Table 4F1A. RATING FACTOR FOR AMBIENT TEMPERATURE 60 C thermoplastic or thermosetting insulated cable: Ambient temperature 35 C 40 C 45 C 50 C 55 C Rating factor 0.91 0.82 0.71 0.58 0.41 110 C flexible cable: Ambient temperature 35 to 80 C 85 C 90 C 95 C 100 C 105 C Rating factor 1.0 0.96 0.85 0.74 0.60 0.42 90 C thermoplastic or thermosetting insulated cable: Ambient temperature 35 to 50 C 55 C 60 C 65 C 70 C Rating factor 1.0 0.96 0.83 0.67 0.47 150 C flexible cable: Ambient temperature 35 to 120 C 125 C 130 C 135 C 140 C 145 C Rating factor 1.0 0.96 0.85 0.74 0.60 0.42 Glass fibre flexible cable: Ambient temperature 35 to 50 C 155 C 160 C 165 C 170 C 175 C 35 to 150 C Rating factor 1.0 0.92 0.82 0.71 0.57 0.40 423