Features

Similar documents
Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Product Specification

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Product Specification

Product Specification

OPTICAL AMPLIFIERS SELECTION GUIDE

LaserPlus Model LP-OA EDFA OPERATING MANUAL

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

4120 Fire Alarm Network Reference

Set-Up Procedures. Before You Start

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

T3/E3 Fiber Optic Line Drivers

PONA 3000 Series High Power EDFA User s Guide

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Instruments Designed for POF & Fibre Optic Cable Testing

MW9070B Optical Time Domain Reflectometer

Fiber Optical Multiplexer

Four channel video link For low cost video transmission

MT-RJ Optical Fiber System Field Testing

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

FIRERAY 5000 range USER GUIDE

Fiber Optics and Liquid Level Sensors Line Guide

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

AIS750 Series Alarm Annunciator

Noyes OFL 250B Specs Provided by

Rack Mount High-Power EDFA Installation Guide

FlexScan OTDR With SmartAuto and LinkMap

ACTIVE INFRARED BARRIER

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Clearlite Photonic Fibers

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

Fibre Optic Basics FIA Summer Seminar 2014

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

RACK MONITORING SYSTEM RAMOS Ultra

FlexWave Element Management System. Alarm Reference FWPP May 2017

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Galaxy Pulsar Plus Digital Battery Plant Controller

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

PUMP AND SIGNAL COMBINERS

WP4086 Condition Monitoring System

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

EOTec 2C32 Installation Guide

OPTICAL FIBER SOLUTIONS

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

EnvironmentalMonitoring

4 Channel Contact Closure SFP DIN Fiber Link System

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Fiberizer IIT-6000 Series

VIEW500 FASTEST STANDARD OTDR

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

Sony Full HD Blu-ray Matching 5.1-channel Audio Systems HT-SF2300, HT-SS2300 and HT-IS100

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

FG-750 Client API SDN-READY INTELLIGENT OTDR

WaveCEx: WDM module for PON coexistence

Remote fiber testing to improve SLA s

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

4-Channel Contact Closure Fiber Link Card System

VACIE REFERENCE GUIDE REVISION 1.2.6

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Diode-Pumped Solid-State Blue Lasers

LORAIN CSP DC Power System

Forever Flowering Greenhouse Suggested Setup Wiring Diagrams

VIEW500 USER-FRIENDLY STANDARD OTDR

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

LORAIN CIP 4890/48120 DC Power System

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Eyecom Explosion Sensitive Field Signaling and Communications. Jan. 2014, all right reserved

ACCESS Master MT9085 Series. Product Introduction

OWNERS MANUAL OPERATION GUIDE


Return loss measurement of fiber optic components

Bosch EVAX System - High-rise Applications

IF-L/RF Protection Switch

HOA Series IR Opaque Optoschmitt Sensor, Transistor Output, Two Mounting Tabs, Plastic Package

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

TFS-FS1 Optical Leakage Detector. Operation Manual

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Engineering Guideline. pac- Carriers Type Universal

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Transcription:

Applications Features Support O-band, 1260~1340nm Band amplification Maximum output power can be achieved 13dBm; Support three working modes ACC, APC and AGC; Through RS232 or SNMP to progress Status monitoring or control Support 19 1U CL- SOA-100-RM1 (1 slot), 2.5U CL-SOA-100- RM8 (8 slot), 6U CL-SOA-100-RM16 (16 slot Rack Mount) 220VAC or -48VDC dual power sup; PART NUMBER TEMPERATURE CL-SOA-100-RM -5 C to 55 C Headquarter: HK. 4/Fl., Hong Kong & Macau Bldg., 156-157 Connaught Road Central Website:

Equipment Description This manual is a description of the use of the SOA amplifier board. This series of optical amplifiers is the SOA series amplifier products that our company launched, which can be achieved amplification for 1260nm ~ 1340nm wavelength range. It can be easily used in 10G / 40G / 100G transmission system, the maximum can support 160G / s rate. The maximum output power reaches 13dBm. It can be used for power amplification, line amplification, pre-amplification and other occasions. Working modes are ACC, APC and AGC. Can be through RS232, SNMP, etc. to achieve network monitoring and control). Parameter condition Min Typ Max Unit Wavelength Range 100GE 1290 1320 nm Input Power -20-10 dbm saturation output power 8 13 dbm gain 18 29 db Flatness 2 db noise 7.5 db polarization dependent gain 2 db operating temperature range -5 55 operating humidity 5 95 % storage temperature -40 85 working voltage 220VAC,-48VDC V Power Consumption 1 SOA 10 W Single cassette 26.5(W) 195(H) 252(D) 1 slot 482.6(W)x44.5(H)x320(D) 8 slot 482.6(W)x111(H)x360(D) 16 slot 482.6(W)x111(H)x350(D) mm LC/SC Headquarter: HK. 4/Fl., Hong Kong & Macau Bldg., 156-157 Connaught Road Central Website:

Products Panels and interfaces Equipment Interface Definition CL-SOA-100-RM Universal panel Interface Silk Screen Name Function/Link In1 Out1 In2 Out2 SOA1 Input port SOA1 Output port SOA2 Input port SOA2 Output port The first way of SOA Small Signal power input port The first way of SOA Amplify output port The second way of SOA Small Signal power input port The second way of SOA Amplify output port Headquarter: HK. 4/Fl., Hong Kong & Macau Bldg., 156-157 Connaught Road Central Website:

Indicator light instruction Indicator light silk screen PWR RUN In1 Out1 In2 Out2 Equipment Installation and opening Name Power Light SOA Run Light SOA1 Input alarm light SOA1 Output alarm light SOA2 Input alarm light SOA2 Output alarm light Description SOA Light on, SOA power supply is normal, Light off, power supply failure SOA Light on, SOA power supply is normal, Light off, power supply failure SOA Light on, the first way of SOA Reception is not normal, Light off, Reception normal SOA Light on, the first way of SOA Output is not normal, light off, Output normal SOA Light on, the second SOA Reception is not normal, light off, Reception normal SOA Light on, the second SOA Output is not normal, light off, Output normal 1 Insert the SOA card into a 1U, 2U, or 6U rack; 2 Check the panel lights carefully, PWR light, SOA board power supply normal, RUN light, SOA card normal; 3 To remove the protective cap on the optical port, input the optical signal, if the connection is correct and there is a signal on the line, this time, the panel only power indicator light&run (green) light on, the other are in the off state. Common problems and solutions 1, The power light off: Please check whether the card is inserted correctly or not, and the rack is working properly or not; 2, The input alarm indicator light: turn off the power, check whether the optical input power at the optical port Within the input range of SOA amplifier or not. If you still can not solve, please confirm whether the input and output of the equipment is reversed or not. Whether the Optical signal wave of the equipment is within the operating wavelength range or not. 3, the temperature alarm: Please confirm whether the ambient temperature of the equipment is too high or not. Headquarter: HK. 4/Fl., Hong Kong & Macau Bldg., 156-157 Connaught Road Central Website:

4, the output alarm, pump alarm: if this alarm occured, please turn off the equipment, and promptly contact us. Ordering information 19 1U CL-SOA-100-RM1 (1 slot), 2.5U CL-SOA-100-RM8 (8 slot) 6U CL-SOA-100-RM16 (16 slot Rack Mount) Headquarter: HK. 4/Fl., Hong Kong & Macau Bldg., 156-157 Connaught Road Central Website: