OPALIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

Similar documents
ESSENCIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

to the owner s Manual and the owner important: To be kept for the owner Chromatherapy and WarmTouchShell TM.

OWNER S MANUAL IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER

GEYSAIR TM ADDENDum. to the owner s Manual. and the owner

Laurel Mountain Whirlpools. Walk-In Bathtub Installation Manual

ARLEY STEAM SHOWER ENCLOSURE

COPPER FREESTANDING TUB

Whirlpool Bathtub Model Number: MT618

FREWIN STEAM SHOWER ENCLOSURE

LEVENS STEAM SHOWER ENCLOSURE

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

Installation and Operation Manual MG-304. Please read this manual carefully before use.

owner s manual produitsneptune.com Do not discard. Save these instructions for further use.

OWNER S MANUAL WISTERIA

Acrylic Claw Foot Tub

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ELLA SOAKING WALK IN BATHS OWNERS MANUAL. Representing these model numbers: L / R Elite Soaking L / R Royal Soaking

IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

Kallista Bath Flip Drain

SYSTEM BASIC WHIRLPOOLS

Access Tubs. Installation & operating instructions COSTCO MODEL # / RIGHT COSTCO MODEL # / LEFT

Destination Collection Whirlpool Bath Installation Instructions

Access Tubs 3053 HYDRO INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Vintage Whirlpool Baths: K-702-AC K-702-H-AC CA (9427) Copyright 1994 Kohler Co.

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

1-866-PENNERS

INSTALLER: Save these instructions. for owner. owner s + operator s. manual

RESIN FREESTANDING TUB

NEPTUNE Steam Room Installation Instructions

O W N E R S MANUAL ROUGE

Installation Instructions

SUPPLEMENTARY INSTRUCTIONS

#PSBTWE1000 INSTALLATION GUIDE

WALK IN BATH TUB OWNER S MANUAL

Acrylic Claw Foot Tub

Spa Control System OWNER S MANUAL

SAVE THESE INSTRUCTIONS

STAINLESS STEEL TUB INSTALLATION

Meditub. Installation & operating instructions. Operating instructions

Cable Drain & Cable Drain Trim Kit

Escape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)

ATTENTION INSTALLER: Please deliver this manual to homeowner.

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Infrared Room Installation & Operation Instructions

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

1PIECE FREESTANDING BATHTUB

Hydrotherapy Jets (Remote Water Quality System)

CAST IRON PEDESTAL TUB

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

Threaded Faucet Installation

ACRYLIC PEDESTAL TUB

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

WINE AND BAR SERIES. Sink Installation Kit. For assistance, call ; for UK ; at

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

ELLA SOAKING WALK IN BATHS OWNERS MANUAL REPRESENTING THESE MODEL NUMBERS: L / R Elite Soaking L / R Royal Soaking

ELLA MASSAGE WALK IN BATHS OWNERS MANUAL

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Access Tubs 3238 DUAL ( AIR/HYDRO ) INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS. Costco Item # /394831

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Viking Installation Guide

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Installation Guide. Install your new sink with step-by-step instructions.

Access Tubs. Installation & operating instructions. Costco Item # /394831

Ella Acrylic Outward Swing Walk In Tub OWNER'S MANUAL

K-870-JA-AA K-872-JA-AA

Installation & operating instructions

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

Installation Instructions PRO SERIES

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

IMPORTANT INSTALLATION and OPERATING INSTRUCTIONS

ODEON OVE. A. Ordering Information. B. Required Electrical Service T01-C INSTALLATION INSTRUCTIONS

OWNER S MANUAL ENTREPRENEUR

- INSTALLATION - USER S GUIDE - - REPLACEMENT PARTS -

VENTILATION FAN / LED LIGHT

Installation Guide BUBBLEMASSAGE. English page T01-A

Installation Instructions

Installation Instructions

CONGRATULATIONS! You are now the owner of the world s best walk-in bathtub from the inventor and manufacturer of acrylic walk-in bathtubs.

Access Tubs 3060WCA AIR INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

CAST IRON CLAWFOOT TUB

Technical Specifications Section 1

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Homeowners Guide. Bath Whirlpools

RA2 Tahoe PRODUCT MANUAL

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Next Generation Corona Discharge Installation & Operation Manual

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

EnvyWalk-In Tubs. Installation and Operation READ BEFORE UNPACKING! ADA. Complies with. Guidelines LISTED

Transcription:

OPALIA TM IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

TABLE OF CONTENT IMPORTANT SAFETY INSTRUCTIONS...1 PARTS & TOOLS...3 SITE PREPARATION...6 INSTALLATION REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH...7 ELECTRICAL DIAGRAMS...16 REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH...17 CUTTING TEMPLATES: ELECTRONIC CONTROLS...24 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER S MANUAL. Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a Hydro-thermo massage bathtub equipped with a heater. Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage bathtub equipped with heater immediately following strenuous exercise. Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo massage bathtub equipped with a heater. Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage bathtub equipped with a heater. Use this unit only for its intended purposes or as described in this manual. Use only accessories or devices recommended by the manufacturer. Risk of hyperthermia and possible drowning. Check and adjust water temperature before use. Water temperature exceeding 100ºF (38ºC) may be injurious to your health. To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit unless they are closely supervised at all times. To avoid injury, exercise care when entering or exiting the Thermomasseur. The Geysair should always be connected to the hot water intake. If it is not the case, then, the Geysair should be deactivated via the bath control. RISK OF ELECTRICAL SHOCK Disconnect electric power before servicing. Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5 (1,5 m) of the Thermomasseur. Before using the Thermomasseur, its installation should be completelay finished so that a bather cannot accidentally come in contact with electrical components (turbine and power module). For indoor use only. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 1

IMPORTANT SAFETY INSTRUCTIONS (cont d) PERTAINING TO RISKS OF FIRE, ELECTROCUTION OR PERSONAL INJURY READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS DOCUMENT SUPERCEDES THE INSTALLATION INSTRUCTION IN THE OWNER S MANUAL. ELECTRICAL CONNECTIONS: Never drop or insert objects into any openings. The Thermomasseur must be connected only to a supply circuit that is protected by a 20 amp class A ground fault circuit interrupter (GFCI). Optional therapies such as Chromotherapy and/or 2 nd heated backrest and/or WarmTouchShell must be connected to a supply circuit that is protected by a 15 amp class A ground fault circuit interrupter (GFCI). This interrupter is supplied by a certified electrician and must be tested on a regular basis in accordance with manufacturer s instructions. The GFCI ground must be connected. If defective, do not use the Thermomasseur. Disconnect immediately and call a certified electrician. Use 12 AWG (or greater) copper conductors that resist temperatures of at least 194ºF (90ºC). Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g., gr., ground or grounding) is provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution, connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG or more. All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and local building codes and regulations. Install in accordance with manufacturer s installation instructions. For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury. WATER LEAK TEST Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur with water to overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra is not responsible for any water damage caused by improper installation (see Warranty section). 2 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

H I OPALIA TM PARTS & TOOLS REQUIRED STANDARD PARTS - PLUMBING DESCRIPTION QTY A Plated drain clicker 1 B Strainer 1 C Rubber seal 1 A C B D Tee PVC Drain shoe 1 E Anchor set* 1 E D OPTIONAL PARTS - PLUMBING DESCRIPTION QTY F Brass drain shoe 1 G 4 in. brass tailpiece 1 H Nylon conic shaped seal for drain 1 F I Brass nut 2 J Brass pipe 1-1/2 x 3 with flange 1 K Nylon flat seal with flange 1 L K L 1-1/2 male threaded adaptor 1 OPTIONAL PART PLUMBING * J ENSEMBLE ISLAND TUB DRAIN (ITD) Makes installation and servicing easier for removal of bath. Allows you to connect the bath drain tailpiece to the plumbing pipe without need for tightening to seal once the bath is lowered to the floor. SET INCLUDES A CONIC SHAPED SEAL AND A 6 IN. (15 CM) BRASS TAILPIECE. G * : REQUIRED WHEN NO ACCESS IS POSSIBLE UNDER the BATH. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 3

PARTS & TOOLS REQUIRED STANDARDS PARTS FLOOR ANCHOR DESCRIPTION QTY M Threaded anchor 2 N 1/2 Nut 13 zinc 2 O 1/2 Flat washer 2 P M N O Q P #10 X 1-1/2 Countersunk head screw 12 Q Cover seals 2 STANDARDS PARTS THERMOMASSEUR DESCRIPTION QTY A Turbine 1 B MiaPlus Control 1 C MiaMulti Control (option) 1 B D 15 extension cord 1 A C D 4 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

PARTS & TOOLS REQUIRED PARTS & TOOLS REQUIRED Installation template 48-inch level Measuring tape Teflon tape Caulking gun Silicone ABS & PVC Glue Square/Phillips #2 Screwdriver 3/4 Ratchet Adjustable clamps www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 5

PLUMBING SITE PREPARATION See faucet manufacturer s specifications for zoning and plan water supply location accordingly. Position drain according to bath s technical specifications. Baths from Opalia TM collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. FLOOR 1500 LB (680 KG) BEDDING Before installing, ensure that the floor underneath the bath can support 1500 lb (680 kg). The bath may sit directly on the floor. No special bedding installation is recommended by manufacturer, the bathtub can sit directly on the floor. However, the bath can also sit on a concrete bedding. In that case, it is recommended to isolate the concrete between two plastic sheets: one installed on the floor and the other under the bath. SERVICE ACCESS AND VENTILATION A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical components of the system. An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine. There is a technical specification sheet for each BainUltra ThermoMasseur which includes information such as necessary dimensions of site before installation. If you do not already have the technical specifications, download it from the BainUltra Web site at: bainultra.com or call us at: 1 800 463-2187. 6 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE PARTS & TOOLS MOUNTING REQUIRED OF TURBINE WITH ACCESS UNDER BATH PLUMBING FLOOR LAYOUT FOR PIPES AND ACCESS OPALIA 6938 NOTE : Please refer to the Installation Template provided with your OPALIA bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. 1 PLUMBING HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Measure & Align (2x) Anchor M www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 7

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH STANDARD PARTS - PLUMBING A B DESCRIPTION QTY A Plated drain clicker 1 B Strainer 1 C Rubber seal 1 D Tee PVC Drain shoe 1 A B C D C D OPTIONAL PARTS - PLUMBING DESCRIPTION QTY F Tee Brass drain shoe 1 G 4 in. brass tailpiece 1 H Nylon conic shaped seal for drain 1 I Brass nut 1 Flexible Overflow Piping (Factory installed) J Brass pipe 1-1/2 x 3 with flange 1 K Nylon flat seal with flange 1 F L 1-1/2 male threaded adaptor 1 G L K J I H 8 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ) Geysair Hose and Back Flow Preventer 1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX» FLEXIBLE PVC) Hot Water Supply 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included) TURBINE REMOTE MOUNTING SEE STEP 7 page 13 Access to Geysair backflow preventer is necessary for cleaning of the filter. Baths from Opalia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. Geysair component cannot be remote mounted. It must stay at original position, attached to bath. Must never be unplugged. 3 ELECTRICAL WIRING OF OPTIONAL COMPONENTS REMOTE MOUNTING of CONTROL MODULES SEE STEP 8 page 14 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 9

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 4 BATH INSTALLATION - OPALIA 6938 HELPFUL TIPS: Carefully place the tub on its side, on a blanket or a corrugated cardboard. To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps. Floor anchor M Be sure the floor is leveled. Use shims as needed. Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. Apply a bead of silicone around the perimeter of the bath once on the floor. The tub must be securely anchored to floor. Connect the drain. Fix bath to floor by using washers «O» and nuts «N». Install the bath on anchors «M» previously screwed to floor. Remove exceeding silicone. Place cover seals «Q» over openings. Measure & Align (2x) Floor Surface 1 Minimum N O Q M Anchor 10 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 5 ELECTRONIC CONTROL INSTALLATION MIAPLUS & MIAMULTI (OPTIONAL) LOCATION LOCATION: Determine the most convenient location, on the wall close to tub. Peel off the protective film of sticker behind the control. You can add a silicone bead to secure to the wall. Baths from Opalia TM collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. DRILLING OF WALL: Refer to the Cutting Template on page 24 for the location and diameter of the holes. Jig saw with fine cut blade Drill TOOLS REQUIRED 1/4 in. drill bit TOUCH PAD INSTALLATION Push wiring through drilled holes. Remove protective film from watertight seal. Secure to the wall with permanent waterproof sealant (mold-free clear silicone for bathrooms). Secure temporarily with a tape for about 24 h. 5 ELECTRONIC CONTROL INSTALLATION DOT TOOLS REQUIRED 7/8 in. Hole saw Drill TOUCH PAD INSTALLATION Push wiring through drilled holes. DOT WarmTouchShell (WTS) Remove protective film from watertight seal. Secure to the wall with permanent waterproof sealant (mold-free clear silicone for bathrooms). Secure temporarily with a tape for about 24 h. DOT Chromatherapy (LED) If the control is not factory installed, you will find it attached to the turbine, or to the electronic control modules. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 11

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 6 REMOTE MOUNTING OF TURBINE Bottom of door When located in an enclosed location. 1 Floor Choose a location for the turbine with the shortest possible distance from the Thermomasseur bath, no more than 15 ft. (4,6m), and a maximum of six elbow directional changes to ensure system performance. It can be under the floor, in a closet or any other place that can hide the turbine and if needed optional modules. Easy access must remain possible at all time and sufficient air ventilation is necessary for turbine. A service access is necessary. Minimum dimensions are 22 in. x 18 in. (55 cm x 46 cm) to properly reach all electrical components of the system. An air vent is necessary. Minimum dimensions are: 2 in. x 4 in. (5 cm x 10 cm) to ensure proper functioning of the turbine. Geysair cannot be remotely installed. 12 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 7 REMOTE MOUNTING OF TURBINE - AIR PIPE (THERMOMASSEUR ) 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included) 7 REMOTE MOUNTING OF TURBINE - ELECTRICAL CONNECTIONS (THERMOMASSEUR ) See page 16 for electrical diagram GEYSAIR EXTENSION CORD (If required for longer distance, contact BainUltra for ordering) GEYSAIR CONNECTION TO GFCI Outlet United States Junction box Canada For Geysair equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could result in serious personal injury. www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 13

PARTS & TOOLS REQUIRED 8 REMOTE MOUNTING OF TURBINE ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES See page 16 for electrical diagram. Match the colors of the plug-in cables with those of the turbine terminals E A: 2 nd Heated Backrest B: Chromatherapy (LED) C: MiaPlus D: MiaMulti (Option) E : AromaCloud C D A B Junction box Canada TO GFCI Outlet United States Junction box Canada TO GFCI Outlet United States Electrical outlet must be installed by a certified electrician. Installation must be conducted in accordance with all local, provincial/state, and federal building/electrical codes and regulation. Connect electrical supply only after all low voltage wiring is properly installed on turbine. If you did not follow this last step, shut off and then restart your home s circuit breaker. Turbine and air pipe should be clear of building materials and wiring. 14 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER BATH 8 REMOTE MOUNTING OF OPTIONAL THERAPIES (TUB ONLY) ELECTRICAL CONNECTIONS See page 16 for electrical diagram. A : WarmTouchShell B: Chromatherapy (LED) C : DOT WarmTouchShell D : DOT Chromatherapy E : AromaCloud D B A C E C DOT WarmTouchShell (WTS) D Junction box Canada TO GFCI Outlet United States Junction box Canada TO GFCI Outlet United States DOT Chromatherapy (DEL) www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 15

PARTS REMOTE & TOOLS MOUNTING REQUIRED OF TURBINE WITH ACCESS UNDER BATH ELECTRICAL DIAGRAM 20A THERMOMASSEUR et 15A THERAPY 20A CIRCUIT 15A CIRCUIT NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS JUNCTION BOX JUNCTION BOX Flexible Overflow Piping (Factory installed) N L N L N L N L TURBINE WITH GEYSAIR (FOR MIAPLUS, MIAMULTI ) AROMACLOUD (AROMATHERAPY) INMIX MODULE (CHROMATHERAPY) AIRSTREME (WARMTOUCHSHELL ) 16 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

PARTS REMOTE & TOOLS MOUNTING REQUIRED OF TURBINE WITHOUT ACCESS UNDER BATH 1 PLUMBING - ISLAND TUB DRAIN INSTALLATION HELPFUL TIP: Carefully place the tub on its side, on a blanket or a corrugated cardboard. Anchor M Refer to supplied instructions for Island Tub Drain installation. Island Tub Drain Measure & Align (2x) OPTIONAL PARTS - PLUMBING ( DESCRIPTION QTY F Tee Brass drain shoe 1 G 6 in. brass tailpiece 1 H Nylon conic shaped seal for drain 1 I Brass nut 1 J Nylon flat seal with flange 1 K Nylon flat seal with flange 1 L 1-1/2 male threaded adaptor 1 F Flexible Overflow Piping (Factory installed) L K J I H G www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 17

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ) PASSAGE FOR THE ELECTRICAL WIRING OF OPTIONAL THERAPIES IF THE AIR PIPING CONNECTIONS AND POWER SUPPLY OF THERAPEUTIC OPTIONS HAVE TO BE AT FLOOR LEVEL, YOU MUST MAKE AN OPENING ON ONE SIDE OF THE BATH, AS CLOSE AS POSSIBLE TO TURBINE AND CONTROLS. Do not drill through the interior shell. The size of the opening must be large enough to allow wires and pipes to go through. TOOLS REQUIRED Drill 1/4 in. drill bit Jig saw with fine cut blade OPALIA 6938 Air pipe* Geysair Electric cables (Optional therapies) (*) : Location of air pipe can differ from drawing. 18 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 2 TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ) Geysair Hose and Back Flow Preventer 1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX» FLEXIBLE PVC) Hot Water Supply 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») & Fittings (not included) TURBINE REMOTE MOUNTING SEE STEP 7 page 13 Access to Geysair backflow preventer is necessary for cleaning of the filter. Baths from Opalia collection cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. Geysair component cannot be remote mounted. It must stay at original position, attached to bath. Must never be unplugged. 3 ELECTRICAL WIRING OF OPTIONAL COMPONENTS REMOTE MOUNTING of CONTROL MODULES SEE STEP 8 page 14 www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 19

REMOTE PARTS & MOUNTING TOOLS REQUIRED OF TURBINE WITHOUT ACCESS UNDER BATH 4 BATH INSTALLATION OPALIA WITH ISLAND TUB DRAIN HELPFUL TIPS: Carefully place the tub on its side, on a blanket or a corrugated cardboard. To easily manipulate the bathtub in a safe way during installation, we recommend using moving straps. Anchor M Measure & Align (2x) Be sure the floor is leveled. Use shims as needed. Do not remove the protective plastic film on the tub and place a drop-cloth in the tub during installation to protect the acrylic. Apply a bead of silicone around the perimeter of the bath once on the floor. Connect the drain. Install bath on anchors «M» previously screwed to the floor. Remove exceeding silicone. Connect the drain. Fix bath to floor by using washers «O» and nuts «N». Install the bath on anchors «M» previously screwed to floor. Remove exceeding silicone. Place cover seals «Q» over openings. N O Q M 20 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

REMOTE MOUNTING OF TURBINE WITHOUT ACCESS UNDER BATH 4 BATH INSTALLATION DRAIN CONNECTION WITH ISLAND TUB DRAIN (ITD) - INFORMATION Refer to supplied instructions for ISLAND TUB DRAIN installation. ISLAND TUB DRAIN Floor surface Use the 6 in. (15 cm) tail piece supplied with Island Tub Drain www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 21

PARTS REMOTE & TOOLS MOUNTING REQUIRED OF TURBINE WITHOUT ACCESS UNDER BATH FOR THE NEXT STEPS, SEE SECTION : REMOTE MOUNTING OF TURBINE WITH ACCESS UNDER THE BATH 5 ELECTRONIC CONTROL INSTALLATION MIAPLUS & MIAMULTI (OPTION)...11 5 ELECTRONIC CONTROL INSTALLATION DOT (THERAPIES)...11 6 REMOTE MOUNTING OF TURBINE...12 7 REMOTE MOUNTING OF TURBINE AIR PIPE (THERMOMASSEUR )...13 7 REMOTE MOUNTING OF TURBINE ELECTRICAL CONNECTIONS (THERMOMASSEUR ))...13 8 REMOTE MOUNTING OF TURBINE ELECTRICAL CONNECTIONS OF OPTIONAL THERAPIES...14 8 REMOTE MOUNTING OF OPTIONAL THERAPIES ELECTRICAL CONNECTIONS...15 ELECTRICAL DIAGRAM - THERMOMASSEUR & THERAPIES...16 22 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655

OPALIA CUTTING TEMPLATES / GABARITS DE PERÇAGE OPALIA CUTTING TEMPLATES / GABARITS DE PERÇAGE Cut-out for MiaMulti infrared Trou pour infrarouge MiaMulti 1.625" [4.1 cm] 5.125"±0.04" [13.0 cm±0.1 cm] 0.875" [2.2 cm] 1.125" [2.9 cm] 1.625"±0.04" [4.1 cm±0.1 cm] MIAPLUS & MIAMULTI 2.165" [5.5 cm] 1.375" [3.5 cm] R0.125" [R0.3 cm] 5.591" [14.2 cm] Control cut-out Trou du contrôle Control outline Contour du contrôle R0.250" [R0.6 cm] 1.063" [2.7 cm] 11.313" [28.7 cm] AIR INTAKE - OPENING PRISE D'AIR - OUVERTURE 11.063" [28.1 cm] 0.813" [2.1 cm] R0.125" [R0.3 cm] CUTTING TEMPLATES / GABARITS DE PERÇAGE www.bainultra.com Du lundi au jeudi, De 8 h à 20 h (HE). Vendredi de 8 h à 17 h (HE) 24 Printed in Canada. Copyright March 2017 BainUltra Inc. All rights reserved. 45200655 Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. 25 Imprimé au Canada. Copyright mars 2017 BainUltra inc. Tous droits réservés. Certains produits, spécifications et services mentionnés dans le présent manuel sont décrits dans des demandes de brevets en instance ou protégés par des brevets.