QW SERIES WALL SLEEVE (THROUGH WINDOW OPENING) INSTALLATION INSTRUCTIONS. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Similar documents
INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS HIGH EFFICIENCY PACKAGED AIR CONDITIONER

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES EHWA02-AXD EHWA02-AXH EHWA03-AXH EHWA03-AXK EHWA05-AXH EHWA05-AXK

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

Q-TEC QC-Series Chilled Water Air Conditioner

Performance Rating of Unit Ventilators

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

Q-Tec TM QC-Series Chilled Water Air Conditioner

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

QW SERIES GEOTHERMAL R-410A STAGED CAPACITY PACKAGED HEAT PUMP INSTALLATION INSTRUCTIONS QW2S1 QW3S1 QW4S1 QW5S1. Models:

Q-TEC Q24A-Q60A Air Conditioners

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST

INSTALLATION INSTRUCTIONS

MODELS B1PA024, 030 AND 036

CHAPTER 6 [CE] REFERENCED STANDARDS

Performance Rating of Refrigerant Pressure Regulating Valves

WG242DA WG242DB WG243DC WG302DA WG302DB WG303DC WG362DA WG362DB WG363DC WG423DA WG423DB WG424DC WG482DA WG482DB WG483DC WG602DA WG602DB WG603DC

1997 STANDARD for APPLICATION OF SOUND RATING LEVELS OF OUTDOOR UNITARY EQUIPMENT. Standard NORTH FAIRFAX DRIVE! ARLINGTON, VIRGINIA 22203

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

WARNING READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION.

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

LV CONTROLLER

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS & LOW VOLTAGE CONTROL CIRCUIT WIRING MODELS J18H2 J24H2 J30H2 J36H2 J42H2 J48H2 J60H2

WARNING READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION.

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 3-1/2 thru 5 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

INSTALLATION INSTRUCTIONS

QTEC SERIES PACKAGED HEAT PUMP Models: Q24H1 Q30H1 Q36H1 Q42H1 Q48H1 Q60H1 INSTALLATION INSTRUCTIONS

Bard Air Conditioning System

NISSAN FRONTIER INSTALLATION INSTRUCTIONS

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

INSTALLATION INSTRUCTIONS

REPLACEMENT PARTS MANUAL

Installation & Maintenance Data IM Contents

Performance Rating of Heat Pump Pool Heaters

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MCE4 Series. Electric Cooling Package Unit. Save these instructions for future reference

INSTALLATION AND SERVICE INSTRUCTIONS

Standard for 2006 Performance Rating Of Positive Displacement Ammonia Compressors and Compressor Units

51AKS I S O OWNER S MANUAL

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

REPLACEMENT PARTS MANUAL

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

ENGINEERED PRODUCT GUIDE /////////////// ENGINEERED PRODUCTS FOR YOUR APPLICATION. SCHOOL MODULAR DEHUMIDIFICATION VENTILATION OPTIONS

INSTALLATION INSTRUCTIONS

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

51AKB / 51 AKC OWNER S MANUAL

Installation Instructions

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Performance Rating of Heat Pump Pool Heaters

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

IMPORTANT: Read and save these instructions.

QTEC SERIES PACKAGED AIR CONDITIONER Models: Q24A1D Q30A1D Q36A1D Q42A1D Q48A1D Q60A1D INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL LIST OF SECTIONS. 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5

PROPOSED REGULATION OF THE STATE PUBLIC WORKS BOARD. LCB File No. R102-11

INSTALLATION AND SERVICE INSTRUCTIONS REPLACEMENT PARTS MANUAL

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

REPLACEMENT PARTS MANUAL

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Viking Installation Guide

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

WALL MOUNTED PACKAGED HEAT PUMP INSTALLATION INSTRUCTIONS. Models: WH301, WH361. Bard Manufacturing Company Bryan, Ohio 43506

INSTALLATION INSTRUCTIONS

SWIMMING POOL & SPA HEATER D-2

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

Installation Instructions

INSTALLATION INSTRUCTIONS FOR RCQD COILS

Installation Instructions

AHRI Guideline N Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

Discharge Air Nozzle Kits

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

Specifications for Fluorocarbon Refrigerants

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Transcription:

INSTALLATION INSTRUCTIONS QW SERIES WALL SLEEVE (THROUGH WINDOW OPENING) Model: QWVSR42 MIS-1828 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-433B Supersedes: 2100-433A File: Vol. II Tab 14 Date: 03-28-12

CONTENTS Getting Other Information and Publications...1 Shipping Damage...2 General...2 Installation of Wall Sleeve...2 Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Sleeve Dimensions...3 Placement of Unit to Wall...4 Wall Sleeve Mounting Bracket Detail...5 Silicone Sealing of Wall Sleeve...6 Mounting Sleeve Angles to Blank Off Board...7 Page 2 of 9

Getting Other Information and Publications These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard. Standard for the Installation... ANSI/NFPA 90A of Air Conditioning and Ventilating Systems For more information, contact these publishers: ACCA Air Conditioning Contractors of America 1712 New Hampshire Avenue, NW Washington, DC 20009 Telephone: (202) 483-9370 Fax: (202) 234-4721 Standard for Warm Air... ANSI/NFPA 90B Heating and Air Conditioning Systems ANSI American National Standards Institute 11 West Street, 13th Floor New York, NY 10036 Telephone: (212) 642-4900 Fax: (212) 302-1286 QW Installation Instruction Manual...Bard/2100-381 ASHRAE American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. 1791 Tullie Circle, N.E. Atlanta, GA 30329-2305 Telephone: (404) 636-8400 Fax: (404) 321-5478 BARD Bard Manufacturing Company 1914 Randolph Drive Bryan, OH 43506 Telephone: (419) 636-1194 Fax: (419) 636-2640 Page 3 of 9

SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier s agent. GENERAL The QWVSR42 Wall Sleeve is designed for use with QW Series Water to Air Heat Pumps for an application through a window opening. The equipment covered in this manual is to be installed by trained service and installation technicians. These instructions explain the recommended method to install the wall sleeve. These instructions and any instructions packaged with any separate equipment required to make the entire air conditioning system should be carefully read before beginning the installation. While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made. Installation of Wall sleeve See Figure 2 for general placement of unit to wall. Maximum windowsill height for use of the QWVSR42 as measured from the floor inside of the building where the QW unit is setting is 42 inches. Unlock the rollers on the QW unit and roll the unit near the window. The wall sleeve will be attached to the unit with two mounting brackets that are provided. (See Figure 3.) Attach the brackets to the wall sleeve by driving the screws from the inside out. Position sleeve to unit and measure from the floor up 32-3/8 inches. Drill six (6) 1/8" diameter holes in the cabinet through the brackets and attach with screws. Twelve (12) screws are provided. Roll the unit up to the window; center on blank off board; and mark around the mounting flanges of the sleeve. Pull the unit away from the window and cut the opening 1 inch smaller on all four sides. The bottom of the sleeve is located below the windowsill so any rainwater that enters the sleeve must be drained into the building drain system. There is a drain connection provided in the right side of the wall sleeve. The connection size is a 3/4" pipe coupling. At this point you may chose to attach the drain. If a flexible connection is to be used, a P trap is not required. Apply a bead of silicone around the mounting flange of the sleeve that will mate up to the window blank off board. (See Figure 4.) Roll unit up to the window and attach with field-supplied screws. There are four sheet metal angles provided to cover the raw edge of the opening in the window blank off board. They are to be attached to the window blank off board with field-supplied screws. Seal these angles to the sleeve with silicone. (See Figure 5.) The wall mounting brackets that are supplied to attach the QW unit to the wall are not long enough for this type of installation. They will need to be modified or field-fabricated. Attach outdoor louver grille with the (4) 1½" long screws provided with this sleeve. Discard side trim pieces supplied with the QW unit. Install side extension kit model QSTX42A-V for platinum vinyl or QSTX42XA-4 for gray paint. These extension kits are purchased separately. Page 4 of 9

FIGURE 1 sleeve dimensions 29 1/8" 31" 40 3/8" 34" 35 13/16" All dimensions reference outside finish. 6 3/16" 13 1/4" MIS-1828 Page 5 of 9

FIGURE 2 Placement of Unit to Wall OUTSIDE WALL WATER LINES INSIDE FLANGE OF SLEEVE WINDOW SLEEVE GRILLE UNIT 42" MAX. WINDOW SILL DRAIN FOR SLEEVE 42 1/2" TO BOTTOM OF GRILLE FLOOR FLOOR LEVEL MIS-1829 Page 6 of 9

FIGURE 3 wall sleeve mounting bracket detail 33 3/8" 20 1/8" 13 3/8" UNIT SLEEVE SIDE 73 3/4" BRACKET 44 5/8" 32 3/8" MIS-1831 Page 7 of 9

FIGURE 4 Silicone sealing of Wall Sleeve SEAL ALL (4) FLANGES SEAL NOTCHES IN ALL (4) CORNERS MIS-1830 Page 8 of 9

FIGURE 5 Mounting sleeve angles to blank off board BLANK OFF BOARD SLEEVE SECURE (4) SLEEVE ANGLES TO BLANK OFF BOARD WITH SCREWS MIS-1832 Page 9 of 9