Traditional Rigid Riser With Eight Inch Rose

Similar documents
METRO BATH FILLER MOUNTED CHR

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

X A M G3/4 G3/

METRO BASIN MONO MIXER CHR

MBSN114P+ BASIN MINI MONOBLOC WITH CLICK CLACK WASTE

INSTALLATION INSTRUCTIONS

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

COX714DC. Dual Control Sensor Kitchen Mixer chrome

MBST110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

Beautifully Traditional

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Beautifully Traditional

Beautifully Traditional

Beautifully Traditional

Thermostatic Bar Valve

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS

Express Thermo Shower Mixer Set With Handset THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

THE QUALIFICATIONS INSTALLATION INSTRUCTIONS NEW SQUARE EXPOSED THERMOSTATIC SHOWER VALVE CHR

Beautifully Traditional

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

INSTALLATION INSTRUCTIONS

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Thermostatic Concealed Shower Valve

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

Telo Shower Mixing Valve TL10016CP

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

THAMES. Dual Control. Installation and Operating Instructions. Thermostatic built-in mixer shower

Installation Instructions Flute Tap Range

Dart Eco concentric thermostatic mixer shower

Plus Bath Shower Mixing Valve CP and PL30020CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Deluge Shower Mixing Valve 10045CP

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Varsity Concealed Shower System

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Puro Mini Dual Control Shower Mixer PU90010CP

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Thermostatic Bar Valves

Leona thermostatic bar mixer shower pole Installation and operating instructions

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Thames thermostatic bar mixer with diverter Installation and operating instructions

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Varsity Exposed Shower Systems

Inta City Shower Mixing Valve CT20010CP

HW3 Handwash Installation and Operating Instructions

Enzo Concealed Shower Mixing Valve

ELINA concentric exposed thermostatic mixer valve

Kiko Bath Shower Mixing Valve KK90015CP

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Mio Concealed Shower Mixing Valve MI40010CP

Self-help Temperature Adjustment

Deluge Concealed Shower Mixing Valve DL40010CP

Franke Specialist Range Pilatus Tap

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

AIRE NENE TYNE EXE. Installation and Operating Instructions. bar mixer showers thermostatic. bar mixer shower pressure compensating

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Installation, Operating and Maintenance Guide

Installation Instructions

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

BELLISIMO concentric exposed thermostatic mixer shower

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

ECO EDEN Concentric Thermostatic Mixer Shower

RAMOR Shower Tower Thermostatic mixer Installation and Operating Instructions

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

WE RECOMMEND INSTALLATION BY A QUALIFIED PLUMBER ONLY

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

DART concentric exposed thermostatic mixer shower with fixed showerhead Installation and operating instructions

ASANA mini exposed sequential thermostatic mixer shower

Cinnamon Kitchen Sink Tap

THAMES mini exposed sequential thermostatic mixer shower Installation and operating instructions

Leona thermostatic bar mixer shower pole Installation and operating instructions

Installation Instructions. Starck

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

Installation Instructions. Hansgrohe S 15721XXX

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

HART concentric mixer shower

Sema thermostatic bar mixer Installation and operating instructions

Transcription:

Traditional Rigid Riser With Eight Inch Rose BS20007013035 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3. Should the installation be completed by a non-qualified person then the guarantee may be considered invalid. For a claim made under our warranty written certification of your installers credentials can be required. For further information or to find a qualified installer in your area please visit the Institute of Plumbers website - www.iphe.org.uk THE QUALIFICATIONS At present, to be a plumber you need to follow the National Vocational Qualification(NVQ) route (Scottish National Vocational Qualification - SNVQ - in Scotland). These qualifications are made up of theory and practical work in the classroom/purpose built training facility and work based experience with a working plumber. Colleges should help students find a work placement, although many students organise it themselves. The S/NVQ qualification works in levels. All recently qualified plumbers should hold S/NVQ Level 2 as basic with Level 3 as the preferred level. Level 2 will give you the foundation you need for a career in plumbing and teach you domestic plumbing to a satisfactory level. Level 3 is more comprehensive and deals with domestic, commercial and industrial plumbing along with aspects such as gas - if you want to one day set up your own business, this is the level to reach. The Institute of Plumbing and Heating Engineering, and the industry as a whole recommends that all plumbers reach a minimum of Level 3. Reaching Level 3 has other advantages. The Institute runs a Master Plumber Certificate, which only those attaining Level 3 or equivalent can reach as long as they have the relevant experience as well. Those with S/NVQ Level 3 can (once in membership with the Institute for five years as a Member MIPHE) gain Engineering Technician EngTech status with the Engineering Council (UK). INSTRUCTIONS A For any further information please contact Bathstore on: 0845 873 8843 Or visit our web-site at www.bathstore.com The manufacturer reserves the right to make technical modifications without prior notice.

IMPORTANT - Please read before installation Please read these instructions carefully before starting installation and keep in a safe place for future reference. Check the contents of the pack carefully before installation. Bathstore will not be held responsible for any de-fit / re-fit costs where faulty product has been fitted. If any fault is found with the product, it must be reported immediately to the customer service. We do not accept responsibility for any problems that may occur through incorrect installation. The success of the installation is, of course, dependant on the alignment and construction of the walls to which fixing is to be carried out. The working pressure of this product is 0.5Bar~6.0Bar. The best water pressure is 2.0Bar~5.0Bar. Warning! Please check for any hidden pipes or cables before drilling holes in the wall. When using power tools always follow the manufacturers user instructions. TOOLS and equipment needed Drill, 6mm Masonry drill bit, Philips screwdriver, Spirit level, Pencil,Inner hexangular spanner. 1019mm 6mm 1. 2. 3. Make sure the shower head has the sealed washer inside. 4. 5. 6. CARE AND CLEANING A Do not use solvents or abrasive material or chemicals to clean the shower rail. Only clean using soapy water and a soft cloth, rinse thoroughly afterwards.

20007013110 INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future reference. General Installation Requirements The installation must comply with regulations of the Local Water Authority as contained in their bylaws. All of the taps in this range are single flow (the hot and cold water mix in the body) and should therefore be supplied with hot and cold water at balanced pressures, both from the tank or both from the mains (via a combination boiler for example). If the taps are not supplied at balanced pressures then the mixer will not function correctly. It will also be necessary to fit non-return valves on both hot and cold feeds. It is very important that all pipe work is flushed thoroughly after installation to avoid damaging the ceramic discs. Minimum/Maximum working pressure These taps are suitable for high and low pressure installations they are fitted with a ceramic disc cartridge which provides a good flow rate with very smooth movement. To ensure that the mixer works adequately under low pressure, the cold water storage tank should be at least 2 metres above the highest installed position. The maximum water pressure is 10 bar (note: mains cold water is normally supplied at between 2 and 3 bar). For installations where the mains pressure exceeds 5 bar a pressure reducing valve should be fitted. Approvals All products are manufactured using materials tested and approved under the Water Bylaws Scheme and comply with requirements of British Standard 5412: 1996 where applicable. Preparation and bylaw requirements These taps are single flow so the hot and cold water mix in the body. Water bylaws require that where the hot water is supplied from a tank and cold from the mains, non return valves are fitted on both hot and cold pipes as close as possible to the tap. These are not supplied. Where combination boilers are fitted it is only necessary to shut off the incoming mains and turn the boiler off, non return valves are not required. WARNING Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any remaining swarf, solder or other impurities. Failure to carry out this simple procedure could cause problems or damage to the workings of the mixer. These hints have been prepared for your guidance, you must exercise due care at all times. We do not accept responsibility for any problems that may occur through incorrect installation. 150 74 82 160.5 30 G1/2 110 113 62 NOTE: ALL DIMENSIONS IN MILLIMETRES 1 2 Thermostatic Shower Valve A.indd 3-4 6/7/09 09:15:19

20007013110 150mm COLD INLET First shut off your water heating system then, with your mains stop cock closed, open the lowest hot and cold taps in the house and allow to run until the cold storage tank and pipes are empty (the hot water storage cylinder always remains full). Where combination boilers are fitted it is only necessary to turn off the boiler and shut off the incoming mains. Fitting isolating valves to the inlet feeds is recommended for ease of maintenance. HOT INLET FIG. 1 PREPARING INLET CONNECTIONS & BACK PLATE COLD INLET PIPE BACK PLATE COVER PLATE NUT GRUB SCREW HOT INLET PIPE BACK PLATE OLIVE RISER OUTLET BACK PLATE SCREWS COLD INLET Remember to turn off the mains water supply before connecting to any existing pipe work. Warning! Please check for any hidden pipes and cables before drilling holes in the wall. Preparation. Prepare the supply pipes (hot on the left and cold on the right) at the required height with a width of 150mm centres, making the ends of the pipes 25mm out from the face of the wall, see fig 1. Remove the nuts and olives and place the valve over pipes, mark the position of the back plate and remove. Remove the back plate from the valve by loosening the grub screw underneath, position the back plate onto the wall with the grub screw at the bottom and mark the position of the 3 holes. Drill the 3 x 6mm holes to a depth of 40mm and insert the wall plugs. Fix the back plate to the wall with the supplied screws Valve. Slide the cover plates onto the nuts and position on each pipe with the cover plate against the wall, slide an olive onto each pipe. Push the valve over each pipe and into the back plate, tighten the 2 nuts onto hot and cold inlet, and then the grub screw underneath the valve. Finally connect the valve the riser. Note: There is the option to fit the valve as described and then move the stopper from bottom outlet to the top. This will allow for a flexible hose to be used. Having first checked all new connections, turn on the mains stop cock, close all taps except the new valves and as the system starts to refill check for leaks. Once you have satisfied yourself that there are no leaks, switch on the water heating. COVER PLATE NUT OLIVE HOT INLET BOTTOM OUTLET FLOW CONTROL HANDLE OPERATION Turn the Flow control handle to turn on and off and to increase/decrease the flow of water. Turn the Temperature control handle to increase/decrease the temperature. To change the set temperature see section on page 5 Temperature setting. FLOW CONTROL HANDLE 3 4 Thermostatic Shower Valve A.indd 5-6 6/7/09 09:15:20

20007013110 SETTING REFITTING HANDLES The control handles on this product are factory set and should require no adjustment. However, if for any reason the handles and/or the mixing cartridge is removed it is important the following procedure is employed to ensure trouble-free use. 1 3 1 FLOW CONTROL CONTROL Turn flow control anti-clockwise to maximum flow position, and temperature control anticlockwise until it contacts the internal limit stop. Temporarily refit the temperature control handle until it just engages on the splines of the spindle. Turn on the water. Slowly turn the handle in the required direction until the discharge temperature is achieved. Remove the handle when finished. 4 SLOT IN BODY Wash the cartridge with clean running water, dry and lightly grease the seal. Fit cartridge in body ensuring location lug engages with lower slot on body, Push the cartridge firmly into the body as far as it will go. 2 4 Allow water temperature to stabilise (about 3 minutes) and check temperature. Proceed if temperature is NOT 43 C. STOP END FACE Fit the flow control stop ring over the four lugs on the front of the cartridge, with the stop end face in the desired position (at the bottom vertical). 5 LIMIT STOP FACE A STOP RING 2 FACE B LIMIT STOP Without rotating the temperature spindle, replace the handle so that Face A is directly adjacent to Face B. Refit and tighten the screw. Refit the decorative handle cover. Screw on the cartridge retaining ring, hand tight only. A light tap with a punch on one of the ring projections will ensure the ring remains tight. 3 Screw the front cover shroud onto the cartridge retaining ring, as far as it will go, ensuring the flow control stop ring is firmly held in position. 6 WASHER Shut off the water flow. Unscrew the decorative cover on the temperature control handle. Unscrew and remove the handle retaining screw and keep in a safe place. Pull off the handle and note the position of the internal limit stop. HANDLE STOP END FACE STOP END FACE Turn on water supply. Place flow control handle over large spline and slowly turn clockwise until water flow stops. Tighten handle a further 1/8 of a turn, then remove handle. 5 Thermostatic Shower Valve A.indd 7-8 Without rotating, position the flow control handle and washer over the large spline so that the edge of the screw is adjacent to the stop end face. Tighten the screw on to the splines and fit decorative lever. Refit the temperature control handle and cover. 6 6/7/09 09:15:25