SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

Similar documents
EUROBOX SERIES TYPES CM...N SM...N MM...N

EUROFLAT SERIES TYPES C... S... M...

Forced draught gas burner

MICROFLAT SERIES TYPES C.../U T X

EUROBOX SERIES TYPES CM... SM... MM...

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

Gas burner automatic safety control MMI / 811.1

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Light oil burners. One stage operation

Forced draught gas burner

DATASHEET. Burner control unit FDA 601x

Gas Flare & Rail Burners Gas Flare & Rail Burners Installation Instructions

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

USE AND INSTALLATION HANDBOOK

Flame Safeguards LFE10. Building Technologies HVAC Products

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

UV Flame Supervision System

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

en Direct oil-fired space heaters HD... Operator's manual

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

MBCE-110/230UV Flame Sensor Module

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

LGA... Gas Burner Controls. Building Technologies Division

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

1. GENERAL SAFETY RULES

Interrupted Ignition Series Oil Primary Control

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

MBCE-110/230FR Flame Sensor Module

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

USERS MANUAL FOR GAS BOILERS

C Note! LGI16... Burner Controls. Building Technologies

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

AHE S -12 VDC AHE S - 24 VDC

ELIMINOSTAT DC-ESR-CL-S2

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

Eclipse Self-Check UV Scanner

PCH Heating Condensing Module for Air Handling and Roof Top Units

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Electronic Ignition Water Heater

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Indirect gas-fired air heater

Far-infrared Oil Heater Owner's manual

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Propane Flame Projector Safety instructions and operating manual

MBCE-110/230FR Flame Sensor Module

AUTOMATIC SLICING MACHINE

INSTRUCTION MANUAL. PLASTIC MENDER mod. ITA

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

Design Manual Installation Operation Maintenance

UV - flame detector dual fuel burners for intermittent burner operations

Operating instructions

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

MMI (40-34) Gas burner safty control

Oil burners Brûleurs fioul Stookoliebranders

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

ST 40 Oil Burner. Installation & Maintenance Manual

Installation & Maintenance Manual

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

< Apparecchiatura di controllo di fiamma > RIVELAZIONE FIAMMA MONO - BI ELETTRODO. SAITEK srl

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Instructions for the fan motor control system, SILVER C

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Operator: Save these instructions for future use!

KEROSENE FORCED AIR HEATER

MOD. 605 E. Made in Italy INSTRUCTION MANUAL

Drying Ovens for Fluxes Models F100 F200 - F400

LFL Series Burner Flame Safeguard Control

Installation, Operation & Service Manual

Gas Fire Patio Heater Q9

FAR INFRARED RAYS HEATER

Light oil - kerosene burner

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

GAZ - FIRED AIR HEATERS TECHNICAL NOTICE AND INSTRUCTIONS FOR MONTAGE ACGH 16/20/28/35/45/55/75/95 ACGC 20/28/35/45/55/75/95 ACGV 26/28/36/45/55/75/95

Old documentation - Only for your information! Product is not available anymore!

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

MP920 SALT CHLORINATOR

Read installation manual prior to installation of this appliance! Read user manual before putting this unit in operation!

Program module for burner control LME71.000

Drying Ovens Models F3 - F6 - F9

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

03.03.mmm REV.2 09/01

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Operating Instruction

Transcription:

Serie < Automatic burner control unit > MONO DOUBLE ELECTRODE FLAME DETECTION SAITEK srl www.saitek.it info@saitek.it Casalgrande (RE) ITALY Tel. +39 0522 848211 Fax +39 0522 849070

NOTE. AUTOMATIC BURNER CONTROL UNIT C F 5 SERIES MONO DOUBLE ELECTRODE FLAME DETECTION Questo documento è di proprietà di Saitek S.r.l. con divieto di riproduzione e/o divulgazione a terzi senza la propria autorizzazione. Saitek S.r.l. si riserva inoltre di modificare il presente documento in qualsiasi momento senza preavviso.

BURNER FLAME CONTROL C F 5 SERIES page 1 of 4 DOUBLE ELECTRODE FLAME DETECTION INSTRUCTIONS FOR USE. Read carefully and preserve this use and maintenance reference manual. ATTENTION!!! Any indication and operation indicated in the present manual shall be carried out only by authorized and qualified personnel in charge. Improper and incorrect assembly, adjustment, modification, use or maintenance can cause serious damages and accidents to persons and things. Read carefully the instructions before installing the appliance. The assembly shall be in compliance with the regulations in force. In order to prevent accidental electrocutions it is recommended you disconnect the electric current before opening the appliance. Before supplying power check the value reported on the tag. CONFORMITY. The manufacturer declares that: - The CF5 has been designed, realized and tested in compliance with the European Rule EN298 relative to Control and safety automatic systems for gas burners and gas appliances with or without fan. - The CF5 is conform to the essential requirements provided for by Directive 90/396/EEC for gas applications (E.D. 90/396/EEC art. 1 paragraph 2). Classification according to EN 298: B M R L X N APPLICATIONS. The CF5 flame control appliance directly lights and controls intermittent gas burners, or rather burners that shall be turned off at least once in the 24 hours. The burner is checked by an ionization electrode. For grounded grids. With a single restart due to flame put out. The CF5 can be applied directly to the burner in industrial thermal processes for metals, glass, ceramic, plastic, chemical, etc..., where there is no need of a preventilation before turning it on. Besides it can be applied on atmospheric burners for general heating. ATTENTION Avoid presence of condensation inside the box and on the card surface. TECHNICAL SPECIFICATIONS. - For data relative to power supply specifications (V /Hz/W), working temperature ( C), IP protection class, waiting time before starting (Wt), discharge times (lg T), safety (Sc) and threshold of detection (Sens.) refer to the tag. - The load tension shall be the same of the power supply. - Double spark plug detection by electrodes, if request mono electrode or UV lamp - Possibility of using ignition transformers both electronic and standard wound. - LED display: on, block, discharge and detection. - Alarm contact in exchange: NC closed when blocked, NA closed when in detection. This document is property of Saitek Srl. Copying it and/or spreading the contents to third parties without authorization is forbidden. Saitek Srl reserves the right to modify the present document at any moment without prior notice

BURNER FLAME CONTROL C F 5 SERIES page 2 of 4 DOUBLE ELECTRODE FLAME DETECTION DISPLAY CARD. The CF5 flame control device can be supplied with the additional display card STK035 (optional extra), which enables an effective and immediate check of the appliance s functionality. This is possible thanks to the four LEDs of the flame level display, the LED of the safety systems control and the LED of the release control by remote switch, which is on when the main switch is on 0 position in order to signal the voltage presence. (N.B: it can only be used by authorized personnel, keeping the burner to be lighted under strict control). CABLES RECOMMENDED. - IONIZATION: max. length 10 m. with section 1 mm. Place far from interference sources, avoid external electric influences. - IGNITION: like from specific of the constructor of the ignition transformer. Suggested conductor diameter 1 mm. Place singularly far from metal parts. WIRING. Disconnect the plant. In three-phase plants use the same phase on the inputs. No power shall be present on the solenoid valve outlet. ASSEMBLY. - Assembly position at will. - Assembly of the fixed back side by 4 holes formed beforehand, removable by pressure. - Arranged to attack on tube - The CF5 is usually equipped with cable, if not make the necessary holes only in the back side and use fairlead ensuring at least the same protection degree IP (40) The CF5 enabling control deriving from the safety sequence ( main controls device for safety such as thermostats, GAS min., Gas max., seal control, pre-washing, etc...) shall be contacts without tension. Do not invert phase and neutral wire. The outlet power for the solenoid valve and the ignition transformer (usually included in CF5) and the inlet power are the same. The max. current of solenoid valve and ignition transformer is 1A. Alarm contact max 1A 230 Vac not protected by inner fuse. For a correct operating, carry out a good connection of the CF5 earth to the burner ground. This document is property of Saitek Srl. Copying it and/or spreading the contents to third parties without authorization is forbidden. Saitek Srl reserves the right to modify the present document at any moment without prior notice

BURNER FLAME CONTROL C F 5 SERIES page 3 of 4 DOUBLE ELECTRODE FLAME DETECTION COMMISSIONING. 1. Open the gas valve 2. Turn on the plant. 3. Supply power to the CF5 4. Press the IGNITION push-button (power green LED on) 5. Supply power to the enabling terminal in order to start the cycle 6. Waiting time before starting about 5 secs. 7. After this time the CF5 will carry out the ignition cycle. The gas solenoid valve will be driven and at the same time the discharge is carried out (yellow discharge LED on). At the end of the discharge the presence of the flame will be controlled. the manufacturer for a complete overhauling. After the replacement of the safety device, check its operation: - Turn off the main gas valve and check that the appliance does not start. If the safety device works correctly and the wiring is in good order but the appliance starts the burner, send it to the manufacturer for an inspection. OPERATING MODES GRAPHS. Ta => waiting time before starting Partenza senza fiamma 8. In case of flame the appliance goes to the operative mode, turning on the green detection LED and supplying power to the solenoid valve. 9. Differently the CF5 blocks (the gas solenoid valve power will be cut off, the alarm contact will shut and the block red LED will light). It will be necessary to turn off the appliance by means of the ON button in order to reset and restart it. Ta Partenza normale con fiamma t N.B. The terminal shall never be used. This terminal has the unblock function from remote switch and shall be used only by authorized personnel keeping under strict control the burner to be re-lighted. OPERATION CHECK. Ta t 1. During the operating remove the detection pipe 2. The CF5 will try to restart only one time, then it will block because of an anomaly (the solenoid valve power will be cut off, the alarm contact will close and the red LED will light). 3. The burner flame shall die down. 4. In case of different operation, check the wirings and if the problem is not solved disassemble CF5 and send it to Riavvio dopo mancanza fiamma This document is property of Saitek Srl. Copying it and/or spreading the contents to third parties without authorization is forbidden. Saitek Srl reserves the right to modify the present document at any moment without prior notice t

RECTIFICATION OF FAULTS. op CAUTION!!! Danger of death due to shocks! Before intervening on the appliance cut off the tension to any cable. The elimination of breakdowns can be carried out by authorized personnel only. In case of improper repairs or incorrect electrical connections, the good running of the appliance is not granted. The release at distance can be carried out only by authorized personnel keeping under strict control the burner to be lighted? < TROUBLE>! <CAUSE > * <REMEDY>? THE IGNITION SPARK DOES NOT APPEAR.! The distance between the electrode and the burner body is too great. * Set a distance of max. 2 mm.! The igniter cable does not make contact with the pipe. * re-screw the pipe tightly.! The igniter cable has a leakage on the earth. * Check the laying of the cable, clean the ignition electrode.! The ignition voltage is too low. * use an ignition transformer with power > 5 KV! The ignition cable is too long. * Shorten its length to 1 m. (max. 5 m.)! The igniter cable does not make contact. * Screw it tightly on the ignition transformer.? THE GAS DOES NOT REACH IT! The gas solenoid valve does not open * Check the solenoid valve connection.! There is still presence of air in the gas hosepipe. * Make many ignition attempts in order to fill completely the gas hosepipe. BURNER FLAME CONTROL C F 5 SERIES page 4 of 4 DOUBLE ELECTRODE FLAME DETECTION? THE GAS DOES NOT REACH IT AND THE IGNITION SPARK DOES NOT APPEAR, THE CF3 DOES NOT START.! Short circuit in the ignition or in the solenoid valve outlet. * Check the wiring - in case of short circuit in outlets eliminate it and change the inner fuse (2,5 A). Or send the appliance to the manufacturer.? THERE IS THE FLAME BUT THE DETECTION LED IS OFF.! The detection electrode is in short circuit because of dirt, soot or damp.! The detection electrode is not in a correct position as to the flame.! The combustion air/gas ratio is incorrect.! The flame makes no contact with the burner body because air and/or gas pressure is too high.! The burner or CF5 are not earthed correctly.! Short circuit or detection cable interruption.! Phase and neutral wire inverted. * Eliminate the defect.? THE APPLIANCE DOES NOT PERFORM THE IGNITION CYCLE AND GOES IMMEDIATELY IN DETECTION.! Anomaly on the detection (flame simulation) * Eliminate the cause of the flame anomaly.! Anomaly of the flame detection circuit. * Send the appliance to the manufacturer for its replacement.? THE APPLIANCE DOES NOT START EVEN IF ALL THE TROUBLES HAVE BEEN ELIMINATED AND THE MAIN SWITCH HAS BEEN PRESSED. * Send the appliance to the manufacturer for the functional inspection. This document is property of Saitek Srl. Copying it and/or spreading the contents to third parties without authorization is forbidden. Saitek Srl reserves the right to modify the present document at any moment without prior notice

NOTE. AUTOMATIC BURNER CONTROL UNIT C F 5 SERIES MONO DOUBLE ELECTRODE FLAME DETECTION Questo documento è di proprietà di Saitek S.r.l. con divieto di riproduzione e/o divulgazione a terzi senza la propria autorizzazione. Saitek S.r.l. si riserva inoltre di modificare il presente documento in qualsiasi momento senza preavviso.

03/2011 WARRANTY. Saitek Co. Ltd warrants these appliances to be free from defects in material and workmanship for 12 months from the date of their installation up to a maximum of 18 months from the date of their original purchase by a consumer, provided that the appliances are properly used in accordance with their operating instructions and applications. SAITEK srl Via IV Novembre n 4 42013 Casalgrande (RE) ITALY http://www.saitek.it e-mail info@saitek.it Tel. +39 0522.848211 fax +39 0522.849070