How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Similar documents
A DESCRIPTION OF THE PROBABILISTIC AND DETERMINISTIC MODELLING USED IN FIRECAM

How design fires can be used in fire hazard analysis

Modelling Concepts for the Risk-cost Assessment Model FIRECAMTM and its Application to a Canadian Government Office Building

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

Considerations in the Design of Smoke Management Systems for Atriums

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

Case Study of Underground Car Park. Team Japan

Case Study 1 Underground Car Park

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

and SUMMARY current building code provisions, and alternative

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

Design of Fire safety in Multi Occupancy Residential Accommodation

ECONOMIC JUSTIFICATION FOR SPRINKLER SYSTEMS

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

Development of Seismic-induced Fire Risk Assessment Method for a Building

The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex:

This document is a preview generated by EVS

Comparative Evaluation Method for Fire Safety Design of Large Storage Spaces

( )

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

Simulation study of evacuation in high-rise buildings

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia

Gothenburg dance hall, Sweden, 1998

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Unit 2 Fire Safety (Zone 1)

Patrick D. Gallagher, Under Secretary of Commerce for Standards and Technology and Director

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Research Needs for the Fire Safety Engineering Profession

An experimental study of the impact of tunnel suppression on tunnel ventilation

Sprinklers Modeling for Tunnel Road Fire Fighting

Building Research Note

Test One: The Uncontrolled Compartment Fire

22A Belvedere Avenue, Parry Sound Sprinkler System Consulting Review

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

The Singapore Fire safety Engineering Guidelines (SFEG)

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

Y. ORMIERES. Fire risk analysis method for nuclear installations

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Simulation of Full-scale Smoke Control in Atrium

Virtual Compartment: An Alternative Approach to Means of Egress Design in Airport Pedestrian Tunnel

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

A New Zealand Case Study Building Design 11 th International Conference on Performance

CFD Analysis of Fire Characteristics on Subway Junction Station

Tunnel Fire Dynamics and Evacuation Simulations

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

SURVEY ON FIRE SERVICE INSTALLATIONS FOR OFFICE BUILDINGS IN HONG KONG

Principles of Fire Risk Assessment in Buildings

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

Recent BRANZFIRE enhancements and validation

The Definition of Scenarios for the CESARE-RISK Model

Development of an Environmental and Economic Assessment Tool (Enveco Tool) Francine Amon, Jonatan Gehandler, Selim Stahl

Fire Hazard Analysis of Technical Area 53 Building 1

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

Figure 1. Structure Used For the Simulations.

technical specification smoke venting systems

Date: Place: Technical University of Denmark. Knowledge FOr Resilient society

Uncertainty Analysis For Input Parameters Of Electrical Cabinet Fire Simulation By Coupling Latin Hypercube Sampling And CFAST

Fire Safety Design when Normal Limits Don t Apply

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

Questions for the HFD regarding Bill 69, Evaluation Worksheet for High-Rise Residential Buildings User s Guide ( New User s Guide or NUG )

Case Study 1 Underground car park

Date and Time of Incident. March 10, 1975

Smoke Management in High-Rise Structures

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Probabilistic-deterministic modelling of fire spread

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

Design Occupant Groups Concept Applied to Fire Safety Engineering Human Behaviour Studies

Fire Engineering in High Rise 15 November 2013

Chapter 1 Introduction 1.1 Research Focus This study tries to develop a procedure by which the architecture plans for egress systems can be compared

DEALING WITH FIRE SAFETY

EVACUATION MODELING DEPENDENCE ON INPUT PARAMETERS

Applying the New Zealand Performance Based Design Fire Framework to Buildings Designed in Accordance with NFPA5000

ASSESSING FIRE SAFETY PROVISIONS FOR SATISFYING GREEN OR SUSTAINABLE BUILDING DESIGN CRITERIA: PRELIMINARY SUGGESTIONS

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

SHOULD SMOKE MANAGEMENT SYSTEM BE PROVIDED IN KARAOKE ESTABLISHMENTS?

Mathematical Modeling of Fires

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

Canadian Association of Fire Chiefs Steve Thurlow Dillon Consulting Limited. September 21, 2015

Residential Fire Injury and Death Rates in British Columbia

Transcription:

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs 1 ABSTRACT Noureddine Benichou and Ahmed H. Kashef * Institute for Research in Construction National Research Council of Canada Ottawa, Canada K1A R6 Performance-based regulations allow the designers and building officials the freedom to come up with innovative designs that will provide a level of safety that satisfies the objectives established by the regulations. Such innovative designs often lead to lower fire protection costs. The implementation of performance-based building regulations can be facilitated by the development of engineering tools that can help assess the overall fire safety performance of a building. This paper presents two fire risk assessment models, FIERAsystem and FiRECAM, which can be used as equivalency and performance-compliance design tools for cost-effective fire safety designs. The paper also describes two case studies using these tools in order to demonstrate their utility in evaluating performance-based designs. 2 INTRODUCTION In the event of a fire occurring in a building, the occupants would normally attempt, if possible, to evacuate the building. If, however, the fire and smoke conditions in the building are such that it is not possible to evacuate, then the occupants may have no choice but to return to their respective compartments and wait for the firefighters to arrive at the fire scene to suppress the fire and to rescue them. To help the occupants evacuate the building before the building becomes untenable, building regulations typically require that fire safety measures, such as fire detection, fire suppression, smoke control, and fire resistance systems, are in place to prevent the spread of fire and smoke and to provide occupants with adequate time to evacuate. The level of fire safety that is provided to the occupants depends on how well the fire safety systems work. To help ensure that the required level of fire safety is provided to the occupants, many countries in the world have introduced, or are planning to introduce in the near future, performance-based regulations. In these regulations, the performance of fire safety systems is specified, whereas in the existing prescriptive regulations, only the installation and maintenance of certain fire safety systems are specified. Performance-based regulations allow the designers and building officials the freedom to develop innovative designs that will provide a level of safety that satisfies the objectives established by the regulations. Such innovative designs can often lead to lower fire protection costs. The implementation of performance-based building regulations can be facilitated by the availability of engineering tools that can help assess the overall fire safety performance of a building. To provide tools that can assess the overall fire safety performance of a building, the National Research Council of Canada (NRC) has been developing two risk-cost assessment models called FiRECAM (Fire Risk Evaluation and Cost Assessment Model) and FIERAsystem (FIre Evaluation and Risk Assessment system). FiRECAM can assess both the expected risks to life of the occupants in a building, as well as the expected costs of fire protection and fire losses in the building. Therefore, the model can be used to identify cost-effective fire safety designs that provide the level of safety that is required by the code, or alternative designs that provide a level of safety that is equivalent to that of a code-compliant design. FIERAsystem, a computer model to evaluate fire protection systems for light industrial buildings, is based on a framework that allows designers to establish objectives, select possible fire scenarios, and evaluate the impact of each scenario on life safety and property protection. Australia is the only other country developing a tool, called CESARE-RISK (1998), that is similar to NRC s tools. First, this paper briefly outlines the frameworks for FIERAsystem and FiRECAM and their main submodels. Then, in order to show the utility of FIERAsystem and FiRECAM in evaluating performance- Noureddine Benichou and Ahmed Kashef are research officers at the National Research Council of Canada, Ottawa, ON, Canada K1A R6. 1

based designs, two case studies are presented. The first case shows the compliance with a set of objectives, for various fire safety design options, inside a building using FIERAsystem. For the purpose of this study, a 3-storey building is used as the basis for all analyses. Evaluation of the objectives is based on fire development, fire and smoke spread in the building, and the evacuation of occupants through corridors and stairs to safety at ground level. The second case deals with evaluating equivalency in designing buildings. For this, FiRECAM is used to show how the impact of different fire safety design options on life safety can be assessed. An 8-storey building is used to demonstrate how the model works. Based on the results, the designer could choose the option that provides high safety with low cost. 3 DESCRIPTION OF FIERASYSTEM FIERAsystem uses time-dependent deterministic and probabilistic models to evaluate the impact of selected fire scenarios on life, property and business interruption. FIERAsystem allows the user to perform a number of fire protection engineering calculations using standard engineering correlations, individual sub-models, hazard analysis, or risk analysis in order to evaluate fire protection systems in industrial buildings. The standard engineering correlations model is a collection of relatively simple equations and models that can be used to quickly perform simple fire protection engineering calculations. The main FIERAsystem models include fire development, smoke movement, fire detection, building element failure, suppression effectiveness, fire department response and effectiveness, occupant response and evacuation, life hazard, expected number of deaths, economics, and downtime. Detailed information on the sub-models can be found in Benichou et al. (22). Hazard analysis is the process of running all pertinent sub-models to calculate the number of deaths and property losses in a building for a specified fire scenario. Risk analysis consists of performing hazard analysis of a number of fire scenarios, and then calculating the risk using the probability of the scenarios considered. In addition, FIERAsystem can be used to evaluate whether or not a fire protection system for a building will satisfy specific fire safety objectives. The design of FIERAsystem was made flexible to allow its use by designers of different types of buildings, since modifications can be made to individual sub-models, without having to change the rest of the system model. 3.1 Calculation Process in FIERAsystem Following the approach of performance-based codes, FIERAsystem is based on a framework that allows designers to establish objectives, select fire scenarios and evaluate the impact of each of the selected scenarios on life safety, property protection and business interruption. The FIERAsystem framework leads the user through a series of steps in setting up the problem: Define building characteristics. Define occupant characteristics. Identify fire safety objectives and performance criteria. Identify potential fire scenarios. Select fire protection options, including passive and active fire protection systems. Select calculation procedures such as using standard engineering correlations, running individual sub-models, or conducting a hazard or risk analysis. As the case study in this paper focuses on the fire safety objectives and performance criteria, and how FIERAsystem evaluates their compliance, in the following section, the methodology to evaluate fire safety objectives is explained in detail. 3.2 Process of Satisfying the Objectives Once the applicable objectives are defined, the system will execute the appropriate sub-models to determine whether the specified designs satisfy the acceptance criteria. The following paragraphs explain how the objectives and criteria are evaluated. Fire development: FIERAsystem compares the fire size calculated by the fire development and suppression effectiveness sub-models, in order to evaluate compliance with the objective based on fire size. In addition, FIERAsystem compares the time to flashover calculated by the fire development, 2

suppression effectiveness, and smoke movement sub-models, or the standard engineering correlation module in order to evaluate compliance with the objective based on time to flashover. Life safety: The objective of no critical conditions being reached in the fire compartment, escape routes, and areas of refuge before a period of time is evaluated, based on information from the fire development, smoke movement, and the life hazard sub-models. The objective of no occupants subjected to critical conditions is evaluated based on information from the fire development, smoke movement, occupant response and evacuation, and the life hazard sub-models. Using the time to reach untenable conditions in the escape routes and the time for occupants to respond and evacuate, FIERAsystem can evaluate whether occupants have successfully escaped to a safe place without being impacted by critical conditions. Critical conditions are performance measures of the levels of heat and toxic species in the escape routes and building compartments. Smoke spread: The smoke movement objective is evaluated by the smoke movement sub-model. Given the information on the temperature and thickness of smoke layers and species concentrations in the adjacent compartments, FIERAsystem can evaluate whether smoke has spread, and thus gives a pass/fail flag to the user. Fire spread: The objectives related to limiting fire spread within the building, are evaluated by comparing the time calculated by the boundary element failure and the time of critical radiation levels calculated by the smoke movement sub-models to the established acceptance criteria. Fire spread to adjacent buildings is also evaluated by the radiation to adjacent buildings and fire department response sub-models. Economics: Business interruption is estimated using the expected number of days of interruption due to the size of fire, a flashover event, heat fluxes and smoke concentration. The total number of days of interruption is then compared to the acceptance criterion. Damages to the building and its contents are estimated by the economic sub-model based on the selected fire scenarios. These damage estimates can then be used along with the cost information to estimate the value of the property loss to the building and its contents. The estimates are then compared to the acceptance criteria. 4 DESCRIPTION OF FIRECAM FiRECAM can assess both the expected risks to life of the occupants in a building, as well as the expected costs of fire protection and fire losses in the building. The separation of life risks and protection costs in FiRECAM avoids the difficulty of assigning a monetary value to human life and allows the comparison of risks and costs, separately. The expected risks to life (ERL) value can be used for performance compliance or code equivalency consideration, whereas the expected costs of fire value can be used for cost-effectiveness considerations. Therefore, the model can be used to identify cost-effective fire safety designs that provide a level of safety that is required by the code, or alternative designs that provide a level of safety that is equivalent to that of a code-compliant design. To undertake the evaluation of fire risks and losses, FiRECAM simulates the ignition of a fire in various locations in a building, the development of the fire, smoke and fire spread, occupant response and evacuation, and fire department response. These calculations are performed by a number of sub-models interacting with each other as shown in Figure 1. FiRECAM is a comprehensive model that includes the probability of fire spread in a building, the response of the fire department and the estimate of fire costs, in addition to the typical modelling of fire growth, smoke spread and evacuation. FiRECAM uses statistical data to predict the probability of occurrence of fire scenarios, such as the type of fire that may occur or the reliability of fire detectors. Mathematical models are used to predict the time-dependent development of fire scenarios, such as the development and spread of a fire and the evacuation of occupants in a building. The life hazard posed to the occupants by a fire scenario is calculated based on how quickly the fire develops and how quickly the occupants evacuate the building for that scenario. The life hazard calculated for a scenario multiplied by the probability of that scenario gives the risk to life from that scenario. The overall expected risk to life to the occupants is the cumulative sum of all risks from all probable fire scenarios that may occur in a building. Similarly, the overall expected fire cost is the sum of fire protection costs (both capital and maintenance) and the cumulative sum of all fire 3

losses from all probable fire scenarios in a building. Details of the model can be found in Yung et al. (1999). Legend Models Run Once at Beginning Models Run for each Scenario Data Flow Direction 1 OPTIONAL SUBMODELS Building Evaluation 5 Design Fire 2 3 Fire Department Response Economic 6 7 8 Fire Growth Occupant Response Smoke Spread 4 Boundary Failure 9 Occupant Evacuation 1 Fire Department Action/Effectiveness 11 Fire Spread 14 FINAL REPORTS Expected Risk to Life 12 Expected Number of Deaths 13 Property Loss 15 Fire Cost Expectation Yes Finished all Scenarios? No Figure 1: FiRECAM flowchart 5 CASE STUDY USING FIERASYSTEM COMPLYING WITH A SET OF OBJECTIVES This case study is a demonstration of the compliance with a set of objectives, for various fire safety design options, inside a building. For the purpose of this case, a 3-storey building is used as the basis for all analyses, chosen because it represents a typical building found in many Canadian cities (see Figure 2). The evaluation of the objectives is based on the fire development, fire and smoke spread in the building, and the evacuation of occupants through corridors and stairs to safety at ground level. The building is of concrete construction and has a square shape with a total area of 4 m 2 (2 m by 2 m). The first level has three compartments representing a restaurant and a bookstore, separated by a 2.5-m corridor. The restaurant has 2 separate compartments, a kitchen and a seating area. On the second level, there is a dentist s office and a medical laboratory. The area of the compartments on the first and second floors is 35 m 2 (for each floor). The third level is an open space software engineering office and is assumed to have an area of 4 m 2. The building has two stair shafts at the two ends of the corridor. 5.1 Definition of Occupant Load and Characteristics The number of occupants varies with the location. The total number of occupants in the building is 112, representing about 1 person per 1 m 2. Table 1 shows the occupant load in each compartment along with their characteristics. The occupants are assumed to evacuate through the stairs. If the stairs become untenable, they are assumed to stay in their compartment units waiting to be rescued by firefighters when they arrive. 4

2 m 2.5 m Restaurant Kitchen 4 m 2 m Bookstore Ground floor Dental office Medical lab Second floor Software engineering office Third floor Figure 2. Floor plan of the 3-storey model building TABLE 1. Occupant load and characteristics Compartment Maximum Special Children Seniors Adults Occupant load needs Restaurant Seating Area 47 1 5 14 27 Kitchen 5 5 Bookstore 2 6 2 12 Dentist s Office 15 3 3 9 Medical Laboratory 5 5 Engineering Office 2 2 5.2 Identify Fire Safety Objectives and Appropriate Performance Criteria 1. No flashover in the room of fire origin before complete evacuation of occupants not intimate with the fire. 2. No occupants subjected to critical conditions. 3. No fire spread to adjacent compartments before fire department intervention. 4. No fire spread to adjacent buildings before fire department intervention. 5. No interruption of adjacent businesses before fire department intervention. 5

5.3 Identify Potential Fire Scenarios The potential design t 2 fire scenarios have the fire development characteristics shown in Table 2. For the analysis, only the worst-case scenario will be used, which in this case is likely to be the scenario in the restaurant kitchen. TABLE 2. Fire development characteristics Compartment α (1) (kw/s 2 ) Maximum HR (2) (MW) Restaurant Seating area.469 (Fast) 6 Kitchen.469 (Fast) 6 Bookstore.469 (Fast) 6 Dentist s Office.469 (Fast) 6 Medical Laboratory.469 (Fast) 6 Engineering Office.117 (Medium) 6 Note: (1) α fire growth coefficient (2) HR heat release 5.4 Fire Protection Options Three different fire safety design options were considered for analysis and are summarized in Table 3. TABLE 3. Fire safety design options considered Option 1 2 3 Sprinkler system No No Yes Smoke detection Throughout Throughout Throughout Alarm Central Central Central Fire compartment door conditions Open (1% open) Open with self closing device (5% open) Open (1% open) Fire resistance rating (min) 6 6 6 5.5 Results and Discussion 5.5.1 Results with fire in restaurant kitchen for design option 1 To carry out the analysis, the scenarios listed in Table 2 were considered and the results were compared. Due to space limit, only the results for the fast t 2 fire scenario that occurs in the restaurant kitchen, for design Option 1, will be shown in this paper. For this option, however, this scenario was found to be the worst-case scenario, and will provide the worst fire conditions in the building compared to the other scenarios. To show the dynamic interaction between the development of heat and smoke in the compartment of fire origin and the egress of the occupants, the results for the restaurant scenario, for Option 1, are shown in Figures 3 and 4. Figure 3 shows the heat release rate vs. time in the restaurant kitchen and the software engineering office (for illustration only), as predicted by the fire development model with a maximum heat release rate of 6 MW. In the kitchen, the fire reached a peak heat release rate of 6 MW at a time of 36 s and the flashover occurred at 27 s. The fire development in the engineering office shows a slower growth rate than the kitchen and reaches the maximum 6MW at around 72s. Figure 4 shows the smoke movement model predictions in terms of the temperature and depth of the hot layer, and CO and CO 2 productions with time in the room of fire origin (kitchen). The temperature increases rapidly for 2 s up to about 3 C, after which it drops to 25 C at 25 s. This drop corresponds to the time when the kitchen glass breaks and the cooling effect from it. After 25 s, the temperature starts increasing again and reaches 73 C at the end of the simulation. The temperature in the staircase is much lower than that in the kitchen because the gases generated from the fire in the kitchen cool down as they move through the seating area and corridor. The depth of the hot layer in the kitchen increases from zero at the ceiling, at ambient temperature, to 2.84 m at 1 s. The layer reaches a depth of 1.5 m (1.5 m from the floor level) at about 15 s, which represents the untenable depth to occupants in the restaurant kitchen. The depth of the layer (cold) in the staircase starts almost flat up to 17 s, then increases rapidly to 8.5 m (from the staircase ceiling) in 35 s, where it stays until the end of the simulation. The predictions of CO and CO 2 concentrations in the kitchen indicate a rapid increase in 6

CO and CO 2 at the start of the fire for about 4 s and then a plateau at a concentration of 24 ppm of CO and 1% of CO 2 after about 5 s. As in the case of the hot layer temperature in the kitchen, the CO drops from 145 ppm at 2 s to 1 ppm at 25 s, then starts increasing, due to glass breakage in the kitchen and dilution of CO with fresh air. 7 6 HRR (kw) 5 4 3 2 Detection Flashover in Restaurant Restaurant Kitchen (Fast) 1 Software Engineering Office (Medium) 1 2 3 4 5 6 7 8 9 1 Time (s) Figure 3. Heat release curves for the restaurant kitchen and engineering office 1 9 Upper Layer Temperature in Restaurant Kitchen ( C) Upper Layer Temperature in South Stairwell ( C) 1 9 5 45 1 9 8 Interface Height Restaurant Kitchen (m) Interface Height South Stairwell (m) 8 4 CO (ppm) 8 Temperature ( C) 7 6 5 4 3 2 1 Detection Flashover Fire Department Response Fire Department Intervention 7 6 5 4 3 2 1 Interface Height (m) Concentration (ppm) 35 3 25 2 15 1 5 Detection Flashover Fire Department Response CO2 (%kg/kg) Fire Department Intervention 7 6 5 4 3 2 1 Concentration (% kg/kg) 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 Time (s) Time (s) Figure 4. The build-up of smoke and heat in the kitchen and staircase 5.5.2 Evaluation of the objectives FIERAsystem was used to evaluate compliance with the objectives for all scenarios and design options shown in Tables 2 and 3, respectively. For the purpose of this case study, the objectives were evaluated using the stand-alone sub-models. Table 4 shows a summary of the results of the analysis for different events for the design options. Performance solution for Option 1: Option 1 has a central alarm, smoke detection, 6 min Fire Resistance Rating (FRR), and the doors of the restaurant, bookstore and one staircase to the 1 st floor corridor are open at all times. For this option, the fire was detected at 22 s, and flashover occurred at 27 s, while complete evacuation occurred at 272 s; thus Objective 1 was not achievable. The difference of 2 s may seem very small, but when safety factors are applied to the evacuation time, this difference becomes more significant. On the first floor, lethal conditions happened very fast because of flashover and spread of hot and toxic gases. On the other floors, lethal conditions did not occur during the simulation, because the doors were closed to these levels. The time required for complete evacuation was 272 s while untenable conditions in the staircase occurred at 41 s. This allowed all occupants to make it to a safe location; therefore Objective 2 was satisfied. Fire spread to adjacent compartments, adjacent businesses and adjacent buildings could occur at the earliest at 75 min. The fire department response and intervention were 495 s and 795 s, respectively, and therefore much shorter than the fire spread. This concludes that Objectives 3, 4, and 5 were satisfied. To be compliant with the established objectives, the designer should 7

upgrade the fire safety system to allow occupants to evacuate faster and untenable conditions to occur more slowly. Performance solution for Option 2: Option 2 is the same as Option 1 but with doors with self-closing devices, which were assessed to be open 5% of the time. This option slows down the migration of toxic and hot gases to the other locations, giving a better chance to occupants to evacuate before untenable conditions are reached. The detection and flashover times are the same as Option 1. Although this option limited the door opening, it satisfied all objectives but the first one that required complete evacuation (occurred at 272 s) before flashover (occurred at 27 s). TABLE 4. Results of analysis Option 1 Option 2 Option 3 Detection time 22 s 22 s 22 s Time to flashover in kitchen 27 s 27 s No flashover Time required to evacuate 272 s 272 s 31 s Fire department response 495 s 495 s 482 s Fire department intervention 795 s 795 s 782 s Time to reach untenable conditions in staircase 41 s 525 s 54 s Time for fire spread to adjacent compartments No spread No spread No spread Time for fire spread to adjacent businesses No spread No spread No spread Time for fire spread to adjacent buildings No spread No spread No spread Objective 1: No flashover in the kitchen before complete No No Yes evacuation of occupants not intimate with the fire. Objective 2: No occupants subjected to critical conditions. Yes Yes Yes Objective 3: No fire spread to adjacent compartments Yes Yes Yes before fire department intervention. Objective 4: No fire spread to adjacent buildings before Yes Yes Yes fire department intervention. Objective 5: No interruption of adjacent businesses before fire department intervention. Yes Yes Yes Performance solution for Option 3: Option 3 has the same fire protection as Option 1 with an added sprinkler system. The results show that all objectives are satisfied for Option 3. This is expected since an installed sprinkler system will control the fire within the compartment of fire origin, and prevent the occurrence of flashover, hence smoke and fire spread. The required time to evacuate is higher (31 s) for this option because people respond later, as the fire does not reach flashover. The installation of sprinklers will add to the capital and maintenance costs of the fire safety systems; however, this will be offset with the low damage to building and contents. The economic analysis, however, was not done for this study. 6 CASE STUDY USING FIRECAM FiRECAM was used to assess the fire safety performance of an 8-storey court building. The existing fire protection systems in this building were being re-evaluated to see how they could be upgraded to meet the current building code requirements. The building has a typical floor area of approximately 3,1 m 2, with the 7 th and 8 th floors having smaller floor plates. The building also has two basement levels that are used for underground parking. The building does not have the required sprinkler protection, except in the basement levels and on the 7 th and 8 th floors. The building also does not have the required number of exit stairwells. In addition, the central core of the building has an open escalator that runs from the ground floor to the 6 th floor, which allows smoke to spread easily throughout these floors in case of a fire. Figure 5 shows the layout of the stairwells. There are 4 existing corner stairwells and one centre stairwell. In the model, the single centre core stairwell was used to represent the combination of the existing centre core escalator and the stairwell. The 3 stairwells on the side of the building represent proposed new stairwells to meet the exit requirement. One of the difficulties with this building is that it has a heavy schedule of court proceedings and therefore any upgrade work needs to be carefully planned so as to minimize the impact on these 8

proceedings. In addition, the building structure has asbestos insulation, which makes it difficult to retrofit a new sprinkler system. The objective of this study was to provide an assessment of the risk-to-life reduction of upgrades to sprinkler protection, additional stairwells and/or centre core smoke control for such a court building either individually or in combination. This allows the owners and fire consultants to plan their upgrade work in stages, in case not all of the upgrade requirements can be carried out at the same time. The results of the assessment would help them to determine which requirements to do first and which can provide the highest reduction in risk without causing a major inconvenience in the use of the building. The remaining requirements could be completed later. Table 5 shows the options that were assessed, which included the code-compliant option, the current option (existing fire protection system) and six other cases of individual and combination upgrades of sprinkler protection, additional stairwells and centre core smoke control. Figure 5. Layout of the existing 5 stairwells (solid line) and the proposed 3 new stairwells (dotted line). TABLE 5. Fire safety design options for the court building Options Sprinklers No. of Stairs Centre Core Stairwell Pressurization Code Yes 8 Yes Current No 5 No Case 1 Yes 5 No Case 2 No 8 No Case 3 No 5 Yes Case 4 Yes 8 No Case 5 No 8 Yes Case 6 Yes 5 Yes The expected risk to life predicted for the 8 options, normalized by the Code Option for relative comparisons, is plotted in Figure 6. The Code Option is the code-compliant option, which has a relative expected risk to life value of 1. The Current Option has a high relative risk value of 134, when compared to the Code Option. This is because the Current Option has no sprinkler protection, only 5 stairwells and a high probability of smoke spread through the centre core. Cases 1 to 3 represent different improvements to the Current Option. Case 1 lowers the relative risk value to 13 with the installation of sprinkler protection. Case 2 lowers the relative risk value to 53 with the construction of 3 more stairwells. Case 3 lowers the relative risk value to 58 with the addition of the centre core stairwell pressurization. Cases 4 to 6 represent further improvements to the Current Option with various combinations of Cases 1, 2, and 3. Case 4 lowers the relative risk value to 5 with the installation of sprinkler protection and the construction of 3 more stairwells. Case 5 lowers the relative risk value to 1 with the construction of 3 more stairwells and the addition of the centre core stairwell pressurization. Case 6 lowers the relative risk 9

value to 6 with the installation of sprinkler protection and the addition of the centre core stairwell pressurization. 14 134 12 Relative Expected Risk to Life 1 8 6 4 53 58 2 1. Code Spkr 8 Stairs Stairwell Current No Spkr 5 Stairs No C. Core 13 Case 1 Spkr 5 Stairs No C. Core Case 2 No Spkr 8 Stairs No C. Core Case 3 No Spkr 5 Stairs Stairwell 5 Case 4 Spkr 8 Stairs No C. Core 1 Case 5 No Spkr 8 Stairs Stairwell 6 Case 6 Spkr 5 Stairs Stairwell Figure 6. Relative expected risk to life values for the 8 design options for the court building. 7 SUMMARY AND CONCLUSION To conduct performance-based fire safety designs, the fire community needs fire safety-engineering tools that will allow to evaluate designs and to determine whether they satisfy the established objectives. Two such tools are FIERAsystem and FiRECAM, computer models being developed at the National Research Council of Canada. FIERAsystem and FiRECAM provide information on the safety and associated cost of candidate fire protection systems, and are expected to assist engineers and building officials in evaluating fire protection systems in buildings and in determining compliance with a set of objectives for buildings. In this study, FIERAsystem was used to assess different fire safety design options to determine whether they satisfy a set of user-defined objectives in a 3-storey typical building. Three different design options were considered. Two of the options did not satisfy all established objectives. One option was found to be acceptable based on the set objectives. FiRECAM was presented as a tool that can be used for assessing the impact of design options on life safety and for evaluating equivalency and performance-based design. In this paper, FiRECAM was used to show how the impact of different fire safety design options on life safety could be assessed. An 8-storey building was used to demonstrate how the model works. Based on the results of the analysis, it was shown that the designer could choose the option that provides high safety with low cost. 8 ACKNOWLEDGEMENT The development of the FIERAsystem and FiRECAM was carried out in collaboration with Public Works and Government Services Canada and the Department of National Defence of Canada and their financial support is gratefully acknowledged. 9 REFERENCES Beck, V. R. 1998. "CESARE-RISK: A Tool for Performance-Based Fire Engineering Design", Proceedings of 2 nd International Conference on Performance-Based Codes and Fire Safety Design Methods, Maui, Hawaii, May 3-9, pp. 319-33. Bénichou, N., Kashef, A., Torvi, D.A., Hadjisophocleous, G.V., and Reid, I. 22. FIERAsystem: A Fire Risk Assessment Model for Light Industrial Building Fire Safety Evaluation, Research Report 12, Institute for Research in Construction, National Research Council Canada, pp. 28. 1

Yung, D., Hadjisophocleous, G.V., and Proulx, G. 1999. "A Description of the probabilistic and deterministic modelling used in FiRECAM," International Journal on Engineering Performance- Based Fire Codes, 1, (1), pp. 18-26. 11