LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Similar documents
LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Operating Manual VMD420

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

CMD420 / CMD421 Series

Bender GmbH & Co. KG. All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives

VME420 Voltage and frequency monitor

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

VME421H Voltage and frequency monitor

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Operating Manual RCM420

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Insulation fault evaluator EDS460-DG

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

RCMA423. Residual current monitor for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software-Version: D330 V1.0x.

LINETRAXX RCMS460-D/-L RCMS490-D/-L

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

RCMA423-DM1C Residual current monitor

Remote alarm indicator and test combination MK2430

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

TM800. Remote alarm indicator and operator panels

Process Alarm Module RTA 421

IT system floor-standing distribution

ISOMETER IRDH265 IRDH365

Monitoring Devices 11/1

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Parameterisable compact fault annunciator with permanent display

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Universal fault annunciator for panel mounting

BENDER A-ISOMETER IRDH265 IRDH365

DOCUMENTATION IPS640

DOCUMENTATION IPS640

SCHMIDT LED Measured Value Display MD Instructions for Use

PolyGard 2-channel Gas Controller MGC-03

Documentation guide to get your plant on the positive list (Category A1/A2)

Multi-Gas-Controller MGC2

AO Annunciator Module

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

ISIS SAFETY SYSTEM Installation guide

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Power Supply Display Module PSDM. Installation and Operation Manual

Operating Manual TR600

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter Centrifugal Pump Soft Starter Series

EasyTronic III MANUAL SERVICE

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

DTA. Motor thermistor relay. Benefits. Description

MSM - Expansion modules

TCM-2 Thyristor Control Module DATA SHEET

Line Isolation Monitor (LIM) LIM2000plus

Operating Manual MSF220V(VU)

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

Operating Manual MS220KA and MSR220KA

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Panel Mounted Fault Annunciator Series

T M. User Manual LIM2010. Line Isolation Monitor

Panel Mounted Fault Annunciator Series

Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

02/11/2015

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

CTT8 TEMPERATURE MONITOR DEVICE

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

ANEMOMETER 4403-RF-BAT

MO n : 12JMC rév A

Instruction Manual August sitrans CU 02

Interface and EOL Modules 8

Table of Contents. Protective Relays

Ordering Key. Dielectric strength

ENDA EHTC HUMIDITY AND TEMPERATURE CONTROLLER. Thank you for choosing ENDA EHTC Relative Humidity and Temperature Controller devices.

Transcription:

LINETRAXX VMD420 Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry VMD420_D00137_02_D_XXEN/06.2016

LINETRAXX VMD420 Multi-functional voltage relay for frequency, overvoltage, undervoltage, phase sequence, phase failure and asymmetry monitoring in 3(N)AC systems Product description The multi-functional VMD420 series voltage relay is designed to monitor the frequency, undervoltage and overvoltage and the voltage between two threshold values in 3(N)AC systems. The voltages are measured as r.m.s. values. The currently measured value is continuously shown on the LC display. The measured value required to trigger the alarm relay is stored. Due to adjustable response times, installation-specific characteristics, such as device-specific start-up procedures, short-time voltage fluctuations, etc. can be considered. The devices require an external supply voltage. LINETRAXX VMD420 Device features Undervoltage, overvoltage and frequency monitoring in 3(N)AC systems 0 500 V Asymmetry, phase failure and phase sequence monitoring Various monitoring functions selectable < U, > U, < f, > f Start-up delay, response delay and delay on release Adjustable switching hysteresis r.m.s. value measurement (AC+DC) Digital measured value display via multi-functional LC display Preset function (automatic setting of basic parameters) LEDs: Power On, Alarm 1, Alarm 2 Measured value memory for operating value Continuous self monitoring Internal test/reset button Two separate alarm relays (one changeover contact each) N/C or N/O operation and fault memory behaviour selectable Password protection for device setting Sealable transparent cover Two-module enclosure (36 mm) Push-wire terminal (two terminals per connection) RoHS compliant Typical applications Monitoring of voltage-sensitive machines and electrical installations Switching machinery and equipment on and off at a certain voltage level Monitoring of stand-by and emergency supply systems Supply voltage monitoring of portable loads Protection of three-phase motors against phase failure and phase open-circuit Transformer protection, asymmetrical load can be recognised Function Once the supply voltage is applied, the start-up delay t begins. Measured voltage and frequency values changing during this time do not influence the switching state of the alarm relays. The devices feature two separately adjustable measuring channels (overvoltage/undervoltage). When the measuring quantity exceeds the response value ( Alarm 1 ) or falls below the response value ( Alarm 2 ), the time of the response delays t on1/2 begins. Once the response delay has elapsed, the alarm relays switch and the alarm LEDs light up. When the measuring value exceeds or falls below the release value (response value plus hysteresis) after the alarm relays have switched, the selected release time t off begins. When t off has elapsed, the alarm relays switch back to their initial position. When the fault memory is activated, the alarm relays remain in alarm position until the reset button R is pressed. When the fault memory is set to continuous mode, the alarm parameters remain stored, even on failure of the supply voltage. Preset function After connecting the device for the first time, the nominal system voltage will be determined (PrE run), and the response values for overvoltage and undervoltage as well as for underfrequency and overfrequency will automatically be set. When no voltage is determined within a nominal system voltage range (PrE run), the response values will be set to the minimum or maximum voltage. In this case, the message AL not SET appears on the display. As long as no button is pressed, a nominal system voltage is being searched cyclically (PrE run). If a button is pressed, the search will be interrupted and the message AL not SET disappears. In this case, the appropriate response values have to be set in the menu. When activating the frequency monitoring function, the preset frequency will automatically be stored. Approvals 2 VMD420_D00137_02_D_XXEN/06.2016

Three-phase voltage and frequency monitor LINETRAXX VMD420 Operating elements Wiring diagram 1 2 3 5 1 U S 5 4 2 5 6 7 1 - Power On LED ON (green); lights when supply voltage is applied and flashes in the event of system fault alarm 2 - Alarm LED AL1 (yellow), lights when the set response value >U/<f/>f >f/asy/phs is exceeded and flashes in the event of system fault alarm 3 - Alarm LED AL2 (yellow), lights when the set response value >U/<f/>f >f/asy/phs is exceeded and flashes in the event of system fault alarm 4 - Multi-functional LC display 5 - Test button T : Arrow up button: to change the measured value display, move upwards in the menu or to change parameters To call up the self test: press the button T >1.5 s 6 - Reset button R : Arrow down button: to change the measured value display, move downwards in the menu or to change parameters To delete stored alarms: press the button T >1.5 s 7 - MENU button: Enter button: to confirm the measured value indication or to confirm changed parameters To call up the menu system, press the button T >1.5 s Press the ESC button >1.5 s to abort an action or to return to the previous menu level When the menu item LEd is activated, the alarm LED AL1 indicates that K1 is in the alarm state. When AL2 lights up, K2 is in the alarm position. 1 - Connection to the system/load to be monitored 2 - Supply voltage U S (see ordering information) 3 - Alarm relay K1 : Configurable for <U/>U/<f/>f/Asy/PHS/ERROR 4 - Alarm relay K2 : Configurable for <U/>U/<f/>f/Asy/PHS/ERROR 5 - Fuse as line protection. 6 A fuse recommended. If being supplied from an IT system, both lines have to be protected by a fuse. 3 4 VMD420_D00137_02_D_XXEN/06.2016 3

Three-phase voltage and frequency monitor LINETRAXX VMD420 Ordering information Supply voltage 1) US AC DC Type Art. No. 16 72 V, 15 460 Hz 9,6 94 V VMD420-D-1 B 7301 0005 70 300 V, 15 460 Hz 70 300 V VMD420-D-2 B 7301 0006 Device version with screw terminals on request. 1) Absolut values Accessories Dimension diagram XM420 Type designation Mounting clip for screw mounting (1 piece per device) Art. No. B 9806 0008 Dimensions in mm Open the front plate cover in direction of arrow! Screw mounting Note: The upper mounting clip must be ordered separately (see ordering information). 4 VMD420_D00137_02_D_XXEN/06.2016

Three-phase voltage and frequency monitor LINETRAXX VMD420 Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated insulation voltage 400 V Rated impulse voltage/pollution degree 4 kv/3 Overvoltage category III Protective separation (reinforced insulation) between (A1, A2) - (N, L1, L2, L3) - (11, 12, 14) - (21, 22, 24) Voltage test acc. to IEC 61010-1: (N, L1, L2, L3) - (A1, A2), (11, 12, 14) 3.32 kv (N, L1, L2, L3) - (21, 22, 24) 2.21 kv (A1, A2) - (11, 12, 14) - (21, 22, 24) 2.21 kv Supply voltage VMD420-D-1: Supply voltage US Frequency range US VMD420-D-2: Supply voltage US Frequency range US Power consumption AC 16 72 V/DC 9.6 94 V 15 460 Hz AC/DC 70 300 V 15 460 Hz 4 VA Measuring circuit Measuring range (r.m.s. value) (L-N) AC 0 288 V Measuring range (r.m.s. value) (L-L) AC 0 500 V Rated frequency fn 15 460 Hz Frequency display range 10 500 Hz Response values Type of distribution system 3(N)AC/3AC (3AC)* Undervoltage < U (Alarm 2) (measurement method: AC 6 500/6 288 V Overvoltage > U (Alarm 1) (measurement method: 3Ph/3n) AC 6 500/6 288 V Resolution of setting U 1 V Preset function for 3AC measurement: Undervoltage < U (0.85 Un)* for U n = 400/208 V 340/177 V Overvoltage > U (1.1 Un)* for U n = 400/208 V 440/229 V Preset function for 3(N)AC measurement: Undervoltage < U (0.85 Un)* for Un = 230/120 V 196/102 V Overvoltage > U (1.1 Un)* for U n = 230/120 V 253/132 V Asymmetry 5 30 % (30 %)* Phase failure by setting the asymmetry Phase sequence clockwise/anticlockwise rotation (off)* Relative uncertainty, voltage at 50/60 Hz ± 1.5 %, ± 2 digits Relative uncertainty, voltage in the range 15 460 Hz ± 3 %, ± 2 digits Hysteresis U 1 40 % (5 %)* Underfrequency < Hz 10 500 Hz** Overfrequency > Hz 10 500 Hz** Resolution of setting f (10.0 99.9 Hz) 0.1 Hz Resolution of setting f (100 500 Hz) 1 Hz Preset function: Underfrequency for fn = 400/60/50/16.7 Hz 399/59/49/15.7 Hz Overfrequency for fn = 400/60/50/16.7 Hz 401/61/51/17.7 Hz Hysteresis, frequency Hys Hz 0.1 2 Hz (0.2 Hz)* Relative uncertainty, frequency range 15 460 Hz ± 0.2 %, ± 1 digit Time response Start-up delay t Response delay ton1/2 Delay on release toff Resolution of setting t, ton1/2, toff (0 10 s) Resolution of setting t, ton1/2, toff (10 99 s) Resolution of setting t, ton1/2, toff (100 300 s) Operating time, voltage tae Operating time, frequency tae Response time tan Recovery time tb 0 300 s (0 s)* 0 300 s (0 s)* 0 300 s (0.5 s)* 0.1 s 1 s 10 s 140 ms 335 ms tan = tae + ton1/2 300 ms Displays, memory Display LC display, multifunctional, not illuminated Display range measured value AC/DC 0 500 V Operating uncertainty, voltage at 50 Hz/60 Hz 1.5 %, 2 digits Operating uncertainty voltage in the range of 15 460 Hz ± 3 %, ± 2 digits Operating uncertainty, frequency in the range of 15 460 Hz ± 0.2 %, ± 1 digit History memory (HiS) for the first alarm value data record measured values Password off/0 999 (off/ 0)* Fault memory (M) alarm relay on/off/con (on)* Switching elements Number 2 x 1 changeover contacts (K1, K2) Operating principle N/C operation n.c. or N/O operation n.o. K2: Err, < U, > U, Asy, < Hz, > Hz, PHS, S.AL (undervoltage < U, asymmetry Asy, N/C operation n.c.)* K1: Err, < U, > U, Asy, < Hz, > Hz, PHS, S.AL (overvoltage >U, asymmetry Asy, N/O operation n.o.)* Electrical endurance, number of cycles 10000 Contact data acc. to IEC 60947-5-1: Utilisation category AC 13 AC 14 DC-12 DC-12 DC-12 Rated operational voltage 230 V 230 V 24 V 110 V 220 V Rated operational current 5 A 3 A 1 A 0.2 A 0.1 A Minimum contact rating 1 ma at AC/DC 10 V Environment/EMC EMC IEC61326-1 Operating temperature -25 +55 C Classification of climatic conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3K5 (no condensation, no formation of ice) Transport (IEC 60721-3-2) 2K3 Long-term storage (IEC 60721-3-1) 1K4 Classification of mechanical conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M2 Long-term storage (IEC 60721-3-1) 1M3 Connection Connection type Connection properties rigid flexible without ferrule flexible with ferrule Stripping length Opening force Test opening, diameter push-wire terminals 0.2 2.5 mm² (AWG 24 14) 0.75 2.5 mm² (AWG 19 14) 0.2 1.5 mm² (AWG 24 16) 10 mm 50 N 2.1 mm Other Operating mode continuous operation Mounting any position Degree of protection, internal components (DIN EN 60529) IP30 Degree of protection, terminals (DIN EN 60529 IP20 Enclosure material polycarbonate Screw mounting 2 x M4 with mounting clip DIN rail mounting acc. to IEC 60715 Flammability class UL94 V-0 Documentation number D00137 Weight 150 g ( )* = factory setting ** = The technical data can only be ensured in the operating range of the nominal frequency 15 460 Hz. VMD420_D00137_02_D_XXEN/06.2016 5

Bender GmbH & Co. KG P.O. Box 1161 35301 Gruenberg Germany Londorfer Strasse 65 35305 Gruenberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender.de www.bender.de BENDER Group VMD420_D00137_02_D_XXEN / 06.2016 / pdf / Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the version that was valid at the time of printing.