CMC-TC Basic CMC DK

Similar documents
CMC-TC Processing Unit II Assembly, Installation and Operation Manual

CMC-TC Processing Unit II DK

IndigoVision Alarm Panel. User Guide

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Innovative Circuit Technology Ltd.

Model 135 Reference Document

Innovative Circuit Technology Ltd.

HPE Modular Cooling System 200 User Guide

Diagnostics and Monitoring System WEB Tool 2. User Manual

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

TELSEC MINI PRO User Guide

Instruction Manual Environmental Monitoring Unit with Output Relay

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Laptop / PC Programming Manual

Products no longer available

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Installation, Configuration and User Manual

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Added password for IP setup page : Password must be in IP format!

Room Alert. Room Alert 32E, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Alarm module for leak detection with webserver

HikCentral Web Client. User Manual

the Comprehensive Control Solution

Using ANM Mobile CHAPTER

600 Range Dialer Installation Manual. Version 1.0

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

CAN unit for Analog Sensors

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Simplex Panel Interface Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Outdoor Temperature Sensor

MultiSite Manager. Setup Guide

Typical applications include the vibration detector. Detection of vibrations and shocks

HikCentral Web Client. User Manual

Proliphix. NT10e & NT20e. Configuration Guide

D-TECT 3 IP. GJD260 IP Motion Detector

CMC- Top Concept A redefinition of rack security

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx.

MiNi Server environment MoNitoriNg SySteM

AirFlow Sensor for Dry Contact connection

Room Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

GPS or DCF 77. DTS Masterclock

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

AK-CS On Board Guide

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

User Manual. Dryer Controller M720

Sentient. Downloader Manual D4854

NetGuardian BSM and BSM-G2

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Configuration and Operation Manual for the Unipos

Advisor Advanced Mobile Application User Manual

Avigilon Control Center 5 System Integration Guide

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Daikin ENVi Thermostat installation overview

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

RAy SNMP. Application notes.

Dryer Controller M720

READ AND SAVE THESE INSTRUCTIONS

HERCULES 6 GRAPHICS SYSTEM

Internet enabled RTU/Data loggers. ilog-gsm/edm: Tutorial Vers /2.0 August 2006

D-TECT 2 IP. GJD230 IP Motion Detector

LineGuard 2300 Program User Manual (FloBoss 107)

PowerLogic ION Setup Meter Configuration Software Configuration Guide

idware Idware Remote Site Monitoring Solution

Patriot Systems Limited

RACK MONITORING SYSTEM RAMOS Ultra

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

Version 1.03 January-2002 USER S MANUAL

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

FCD-wire Contents. List of Figures

User Guide UTI-IQCP. Control panel for setting and monitoring of UTI-INV internal temperature regulator. v EN

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

SCAN200E USER S MANUAL

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Operations Manual TS400. Test Station for G450/G460 Gas Detector

3D_ISS. Integrated Software System. User Guide Manual

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

GLOBAL. InstallatIon & operation manual

COMMUNICATOR ET08 / ET081

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

IntesisBox BACnet/IP Server - Notifier ID3000 series

OPERATOR INSTRUCTIONS FOR DM3000

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Memcom Emergency Telephone

Transcription:

CMC-TC DK 7320. Assembly, Installation and Operation A36569 05IT 74

Microsoft Windows is a registered trademark of Microsoft Corporation. Acrobat Reader is a registered trademark of Adobe Systems Incorporated.

Contents Notes on the documentation...5. Associated documents... 5.2 CE labelling... 5.3 Retention of documents... 5.4 Used symbols... 5 2 Safety notes...5 3 Device description...6 3. Housing... 6 3.2 Power supply... 6 3.3 Network characteristics... 6 3.4 Connectable sensors... 7 3.5 System prerequisites... 7 3.6 Scope of supply... 7 3.7 Accessories... 8 3.7. Required accessories... 8 3.7.2 Optional accessories... 9 3.8 Proper usage... 9 4 Assembly...0 4. Assembly instructions... 0 4.2 Assembly of the... 0 5 Installation... 5. Safety and other notes... 5.2 Connecting the power supply... 5.3 Establishing the network connection. 5.4 Establishing the sensor connection.. 2 5.4. Connecting the sensor... 2 5.5 Connecting the alarm relay... 2 5.6 Connecting the extension unit... 2 5.7 Connecting the programming interface... 3 6 Commissioning...4 7 Operation...6 7. Becoming familiar with the menu structure... 6 7.2 Operating notes... 7 7.3 Setting the base configuration... 7 7.3. Network configuration... 7 7.3.2 Configuring the trap receiver... 7 7.3.3 Configuring SNMPv access... 7 7.3.4 Configuring the read/write community... 8 7.3.5 Configuring the authentication traps. 8 7.3.6 Changing the SNMP version... 8 7.3.7 Configuring NTP... 8 7.3.8 Configuring PPP... 9 7.3.9 Configuring the sending of e-mails... 20 Notes on the documentation 7.3.0 Configuring Syslog... 20 7.3. Configuring system name, contact and location... 20 7.3.2 Configuring passwords... 20 7.3.3 Changing the HTTP port... 2 7.3.4 HTTPS (SSL) function... 2 7.3.5 Configuring FTP access... 2 7.3.6 SFTP access... 2 7.3.7 Configuring the timeout window... 2 7.3.8 Configuring Telnet access... 2 7.3.9 Activating restart... 22 7.3.20 Configuring connected sensors... 22 7.3.2 General configuration of the Basic CMC... 22 7.3.22 Configuring SMS notification (GSM unit)... 23 7.3.23 Configuring SMS notification (ISDN unit)... 23 7.3.24 Entering the telephone numbers for SMS notification... 23 7.3.25 Calling the information page... 23 7.3.26 Resetting all settings in the main menu 23 7.3.27 Manual search for sensors... 24 7.4 Transferring files using the serial interface... 24 7.5 Saving files using the serial interface 24 7.6 Access using a browser... 24 7.6. Login... 24 7.6.2 Main page view... 24 7.6.3 Main settings... 26 7.6.4 Configuring the scheduler... 26 7.6.5 Configuring the GSM unit... 26 7.6.6 Configuring the ISDN unit... 27 7.6.7 Configuring the sending of e-mails... 27 7.6.8 Viewing the log file... 28 7.6.9 Administration... 28 7.7 Configuring the sensors... 29 7.7. General overview (status window)... 29 7.7.2 Sensor overview... 30 7.7.3 General overview (sensor configuration)... 30 7.7.4 Configuring the temperature sensor. 32 7.7.5 Configuring the humidity sensor... 32 7.7.6 Configuring the analogue sensor input module... 33 7.7.7 Configuring the access sensor... 34 7.7.8 Configuring the vandalism sensor... 34 7.7.9 Configuring the air flow sensor... 35 7.7.0 Configuring the smoke detector... 35 3

Notes on the documentation 7.7. Configuring the motion sensor...36 7.7.2 Configuring the digital input module..36 7.7.3 Configuring the digital relay output module...38 7.7.4 Configuring the switching combinations for the digital relay output module...38 7.7.5 Configuring the voltage monitor...39 7.7.6 Configuring the voltage monitoring for the voltage monitor with IEC switching output...40 7.7.7 Configuring the switching output for the voltage monitor with IEC switching output...40 7.7.8 Configuring the switching combinations for the voltage monitor with IEC switching output...4 7.7.9 Configuring the voltage monitoring for the voltage monitor with 6 A switching output...4 7.7.20 Configuring the switching output for the voltage monitor with 6 A switching output...42 7.7.2 Configuring the switching combinations for the voltage monitor with 6 A switching output...43 7.7.22 Configuring the 48 V voltage monitor 43 7.7.23 Configuring the leak sensor...43 7.7.24 Configuring the acoustic sensor...45 7.8 Access using Telnet...45 7.8. Login using Telnet...45 7.8.2 Telnet main menu...45 7.9 Perform a software update...46 7.0 Error messages...46 7. Structural layout of the MIB of the Basic CMC...47 7.2 Saving and transferring the configuration files...48 8 Maintenance and cleaning...49 8.. Cleaning...49 9 Storage and disposal...49 9.. Storage...49 9..2 Disposal...49 0 Changes from software version 5.6 50 0. Language selection for the browser interface...50 0.2 Extended options under Combinations...50 0.3 New functions for the alarm and event log...50 0.4 Test functions for traps, e-mail, SMS and pings...50 0.5 Scaling of the 4...20 ma sensor inputs of the input module... 5 0.6 Server shutdown function... 5 0.7 Configuration of automatic door opening... 52 0.8 Delayed alarms... 52 0.9 Protection against cross-site scripting (XSS)... 53 Customer service... 53 2 Technical specifications... 54 3 Technical terms... 55 4 Declaration of conformity... 56 4

Notes on the documentation Notes on the documentation This manual is targeted at technical personnel familiar with the assembly, installation and operation of the. You must read this operating guide before the commissioning and store it for further use at an accessible location. Rittal cannot accept any liability for damage and operational faults that result from the nonobservance of this manual. The manual applies to software release as of Version 5.40 of the.. Associated documents In conjunction with this manual, the manuals for other CMC-TC components and their safety notes, etc. also apply. This manual is also available as file on the accompanying CD-ROM: German: 7320VXXd.pdf English: 7320VXXe.pdf To view the manual, you require the Acrobat Reader program that can be downloaded from www.adobe.com..2 CE labelling The conformance declaration is contained in the Appendix..3 Retention of documents These instructions and all associated documents shall constitute an integral part of the product. They must be supplied to the device operator. The device operator shall be responsible for storage of the documents, to ensure that they are readily available when needed..4 Used symbols Please observe the following safety instructions and other notes in this guide: Symbol for an instructed action: The bullet point indicates that you should perform an action. Safety and other instructions: Danger! Immediate danger to life and limb! 2 Safety notes Please observe the following general safety notes for the installation and operation of the unit: The assembly and installation of the Basic CMC, in particular for the cabling of enclosures with mains voltage, may only be made by a specialised electrician. Other tasks in conjunction with the, such as assembly and installation of system components with tested standard plug connections, and the operation and configuration of the, may be performed only by instructed personnel. Observe the valid regulations for the electrical installation for the country in which the device will be installed and operated, and their national regulations for accident prevention. Also observe the company-internal regulations (work, operating and safety regulations). Before commencing work on the CMC-TC system, it must be disconnected from the mains and prevented from being switched on again. Use only original or recommended products and accessories (see Section 3.7 Accessories). The use of other parts can void the liability for any resulting consequences. Do not make any changes to the other than those described in these instructions or associated instructions. The operational safety of the device is guaranteed only when used correctly. The limit values specified in the technical data (see Chapter 2 Technical specifications) may not be exceeded under any circumstances. In particular, this concerns the permitted ambient temperature range and the permitted IP protection category. If used with a higher required IP protection category, the Rittal CMC-TC must be installed in the housing or enclosure with a higher IP protection category. The CMC-TC system must not be operated in direct contact with water, aggressive materials or inflammable gases and vapours. Other than these safety notes, also observe the special safety notes contained in the individual sections for the particular tasks. Warning! Potential threat to the product and its environment! Note! Useful information and special features. 5

3 Device description 3 Device description The Basic Computer Multi Control (subsequently called ) is an "intelligent" enclosure monitoring system. Installed in its own housing on the enclosure, it uses a wide range of connected sensors to perform the complete physical monitoring of the enclosure, i.e. temperature, humidity, vibration, smoke, voltage, etc. All this information is transferred using SNMP to a management station where it can be administered. The supplied CD-ROM contains software (CMC-TC Manager, as of V.5) that can be used to monitor and administer one or more s. The associated current version of the CMC-TC Manager is available at www.rimatrix5.com. 3. Housing The is installed in a dedicated housing that can be fastened to the inner side of the side panel, to the punched sections with mounting flanges or to shelves of the enclosure using supplied Velcro straps. Mounting units (see Section 3.7. Required accessories) can also be used to mount the housing. 2 3 4 5 I0I0I 2 3 4 Fig. front side Key: Confirm key (C key) 2 Status LED 3 Network LED 4 Serial interface (RS-232 connection) 2 3 4 5 6 2 4 3 P-I 2 C I0I0I Power 24 VDC max. 2,5 A Fig. 2 rear side Key: Sensor connections (-4) 2 P-I²C connection 3 Alarm relay output (floating changeover contact) 4 Serial interface (IOIOI) 5 Network connection 6 Power supply connection (Power) 3.2 Power supply The is supplied with power using an external power pack. The connection cable for the external power pack is available as accessory in various country variants. Select the connection cable as appropriate for the country-specific regulations. A selection of various connection cables is contained in Section 3.7 Accessories. All connected sensors are supplied with power from the. The has an integrated alarm relay equipped with a floating changeover contact. It is used to provide an optical or acoustic alarm. A connection with a serial interface that can be used for various sensor units and extended units is also available. 3.3 Network characteristics The provides an Ethernet 0/00BaseT network connection that supports the following protocols: RS232 serial interface: e.g. Hyperterminal In the Ethernet network: e.g. TELNET SNMPv, compatible with common management systems SNMPv3, HTTP, HTTPS FTP, SFTP NTP (Network Time Protocol) SSH (Secure Shell) SSL 3.0 (Secure Socket Layer) DHCP (Dynamic Host Configuration Protocol) SMTP Optionally, the can also communicate using a Master Unit II as of V 2.2 or using an ISDN or GSM unit. Associated information is available at the Rittal homepage (www.rittal.com) or in Cata- 6

logue 32. Detailed documentation for the GSM and the ISDN unit is also available at www.rimatrix5.com The network connection is made using a suitable network cable with RJ-45 plug in the existing Ethernet network structure. The communication is made using a standard browser and so is independent of the operating system. Any number of Rittal s can be connected in the network, provided sufficient free IP addresses are available in the network. In addition, up to 0 s can be administered from the Rittal CMC-TC Master. Network protocols are used for the communication (password query, switching commands, status queries and alarms) between the Rittal, the administrators and users in the network (network/internet/intranet). The SNMP functionality is also independent of the operating system, the network management protocol must, however, support SNMP V.0 or V3.0. The also supports the Standard MIB II. The private MIB is part of the scope of supply. Further information is contained on the supplied CD-ROM (" II v_x.mib"). The associated current version of the MIB is available in the internet at www.rimatrix5.com The private MIB is required for integration in a building management software. It decodes the transferred trap messages to produce unique messages. Sensor Device description 3 Connectable sensors Model number Temperature sensor DK 7320.500 Humidity sensor DK 7320.50 Analogue sensor input module "4-20 ma" DK 7320.520 Access sensor DK 7320.530 Vandalism sensor DK 7320.540 Airflow monitor DK 7320.550 Smoke detector DK 7320.560 Motion sensor DK 7320.570 Digital input module DK 7320.580 Digital relay output module DK 7320.590 Voltage monitor DK 7320.600 Voltage monitor with 0 A switching output Voltage monitor with 6 A switching output DK 7320.60 DK 7320.6 48 V voltage monitor DK 7320.620 Leak sensor DK 7320.630 Leak sensor 5 m DK 7320.63 Acoustic sensor DK 7320.640 Tab. Connectable sensors A maximum of four sensors can be connected to a. 3.5 System prerequisites Hardware: PC with serial interface and 0/00 MBit network card. Software: Operating system (Linux or Windows), Browser (IE 6.0 or equivalent). 3.6 Scope of supply The unit is supplied in a packaging unit in a fully assembled state. Please check the delivery for completeness. Check the packaging carefully for any signs of damage. 3.4 7

3 Device description Qty. Description with network interface RJ-45 socket (0/00 BaseT) 2 Self-adhesive Velcro strips 90 x 5 mm CD-ROM with software and operating manual Checklist for the commissioning (German/English) Tab. 2 Scope of supply 3.7 Accessories 3.7. Required accessories Depending on the country-specific regulations, you require an appropriate connection cable for the power pack of the. Power supply Description Assembly power pack 24 V IEC 00-230 V AC, UL-approval, 3 A SELV Assembly power pack 24 V IEC 48 V DC Pac ks of Model no. Accessories Required Yes, depending 7320.425 on the power supply 7320.435 Connection cable for power pack IEC plug connection cable Country variant (D) IEC plug connection cable Country variant (GB) 7200.20 7200.2 IEC plug connection cable Country variant (F/B) IEC plug connection cable Country variant (CH) Yes, once for the power pack 7200.20 7200.23 IEC plug connection cable Country variant (USA/CDN), UL approval FT/VW 7200.24 Extension cable, IEC plug and socket 7200.25 Assembly U mounting unit U single mounting unit with strain relief Optional 7320.440 7320.450 Programming cable Programming cable, D-Sub 9 to RJ Yes, max. unit 7200.22 Tab. 3 Required accessories 8

3.7.2 Optional accessories Accessories Max. required number of items Model no. Device description 3 CMC-TC GSM unit CMC-TC ISDN unit RJ2 extension cable; 5.0 m RJ2 extension cable;.0 m Extension cable RJ2; 5.0 m Extension cable voltage DK 7320.820 DK 7320.830 - DK 7200.450 - DK 7320.84 - DK 7200.430 2 DK 7200.520 Tab. 4 Optional accessories 3.8 Proper usage The Rittal is used as an enclosure monitoring system for the monitoring and the administration of various enclosure parameters. Any use other than that described here shall be deemed improper. Rittal cannot accept any liability for damages associated with failure to observe this manual. Where applicable, the instructions for any accessories used shall also apply. 9

4 Assembly 4 Assembly 4. Assembly instructions Install the in an enclosure or in a suitable housing system so that it is also protected from external effects. Also take account of the permitted ambient temperature and humidity operational ranges, and the application-related required IP degree of protection (see Chapter 2 on page 54). 3 2,4,5 4.2 Assembly of the Fig. 5 Assembly with the U mounting unit. Remove the upper two screws from the trim panel. 2. Remove the trim panel. 3. Move the to the retaining plate of the mounting unit. Ensure that the retaining plate sits between the guide rails of the Basic CMC. 4. Replace the trim panel on the mounting unit. 5. Screw the trim panel back on the U mounting unit. Fig. 3 Assembly with mounting module Move the to the retaining plate of the mounting module. Ensure that the retaining plate sits between the guide rails of the. Fig. 4 Assembly with Velcro fasteners Take the self-adhesive Velcro fasteners from the supplied equipment and remove the protective foil from the Velcro fasteners. Ensure that the adhesive surfaces are free of grease and dust. Attach the Velcro fasteners to the housing and position the at the required mounting location. 0

5 Installation Danger! Assembly and installation may only be performed by properly trained specialists. 5. Safety and other notes The Rittal may only be operated with connected protective conductor. The protective conductor connection is made by inserting the IEC connection cable. This requires that the IEC connection cable is connected with the protective conductor at the mains side. The electrical connection voltage and frequency must match the rated values shown on the housing rear side or in the technical data (see page 54). Before commencing work on the Rittal Basic CMC, it must be disconnected from the mains and prevented from being switched on again. Attach the connection cables to the used housing or enclosure using cable ties. To prevent losses caused by unnecessary cable, the used cable lengths may not exceed the lengths specified in the technical data (see Chapter 2 on page 54). 5.2 Connecting the power supply Power Installation 5 To remove the connection plug, draw back the movable ring on the plug and remove the complete plug from the socket. 2 3 Fig. 7 Pin assignment (plug, viewed from the front) Key: Pin : Gnd 2 Pin 2: not assigned 3 Pin 3: +24V 5.3 Establishing the network connection 2 4 3 P-I 2 C I0I0I Power 24 VDC max. 2,5 A Fig. 8 Establishing the network connection Key: Network connection Use the RJ45 network cable to connect the Basic CMC with the existing Ethernet network structure. 2 4 3 P-I 2 C I0I0I 24 VDC max. 2,5 A 5 Fig. 6 Connecting the power supply Key: Power supply connection You must connect the to the power supply using the power packs specified in Section 3.7. Required accessories. Insert the power pack plug in the "Power" socket of the. Ensure that the marking arrow points to the "Power" socket designation. The plug latches itself. After connecting the power supply, the automatically starts the boot process that lasts approximately three minutes. The Alarm LED illuminates green when the boot process has completed. I0I0I 2 3 4 Fig. 9 Checking the network connection Key: Network LED The network connection exists when the Link LED illuminates green or orange. The Link LED on the front side also begins to flash when data is being exchanged over the network: Flash green: 0 Mbit transfer Flash orange: 00 Mbit transfer

5 Installation 5.4 Establishing the sensor connection 5.4. Connecting the sensor 5.5 Connecting the alarm relay The alarm relay is connected using the floating changeover contact. Power Caution! Damage danger! Observe the technical specification of the alarm relay contained in the technical data. The non-observance can damage the alarm relay. 2 4 3 P-I 2 C I0I0I 24 VDC max. 2,5 A Fig. 0 Establishing the sensor connection Key: Sensor connections (-4) Insert the connection plug of the sensors in any of the four connections (max. four sensors). The detects automatically the connected sensors. 2 5 I0I0I 2 3 4 2 4 3 P-I 2 C I0I0I Power 24 VDC max. 2,5 A Fig. 2 Connecting the alarm relay Key: Alarm relay output (floating changeover contact) Connect the alarm relay at the RJ-2 sockets using an RJ-2 plug. After the alarm relay has been connected, it must be configured using software (see 7.3.2 General configuration of the ). Details for the internal circuitry of the alarm relay are shown below: Fig. Checking the sensor connection Key: Confirm key (C key) 2 Status LED Once the sensors have be connected and detected, an acoustic signal sounds and the Status LED of the connection flashes orange. Press the C button to confirm the connection of the sensor. The acoustic signal ends and the Status LED changes from orange to green. The continually polls the ports of the sensors. Configuration changes that affect sensors will be detected and signalled automatically. The acoustic signal and the Status LEDs indicate such a change. Fig. 3 Power circuit of the alarm relay 5.6 Connecting the extension unit You can use the P-I²C connection (RJ 45 socket) to connect a maximum of two extension units (3- phases, DK 7200.520) to the. Further details are contained in the operating guide of the extension unit. 2

Commissioning 6 Power 2 4 3 P-I 2 C I0I0I 24 VDC max. 2,5 A Fig. 4 P-I 2 C connection Key: Extension unit connection (P-I²C connection) - Use the DIP switch at the extension unit as follows to address the extension unit: Switch setting DIP switch at DIP switch at 2 Addressing First connected extension unit Second connected extension unit Tab. 5 Addressing - Use an RJ45 cable to establish the connection between the extension unit and the P-I²C connection of the. 5.7 Connecting the programming interface To configure the, for example, using a notebook, you can connect both using the serial interface. The RS-232 interface of the is provided as RJ-0 front socket. 5 I0I0I 2 3 4 Fig. 5 RS-232 connection Key: Serial interface (RS-232 connection as RJ-0 front socket) Connect the programming cable (DK 7200.22) with the RJ-0 front socket and the serial interface of your PC. 3

6 Commissioning 6 Commissioning Once you have assembled the and installed all connections, you must now configure the. You can do this using the serial interface (see 5.7 Connecting the programming interface), the network connection with an internet browser (see 7.6 Access using a browser) or Telnet (see 7.8 Access using Telnet). You must first establish the connection to the Basic CMC. This is shown below using the HyperTerminal program, part of the Microsoft Windows 2000 operating system, as example. The procedure for other operating systems is similar. To start HyperTerminal, click <Programs> - <Accessories> - <Communication> - <HyperTerminal>. Fig. 8 COM port properties Enter the following parameters: Transmission rate: 9600 bits per second Data bits: 8 Parity: None Stop bits: Protocol: None The standard level range must be observed for the RS-232 interface, otherwise it is possible that the data will be transferred incorrectly. The HyperTerminal login window appears. Fig. 6 Enter a name and select a connection Enter name. Assign the icon for the connection. Fig. 9 Login You must enter your login name (CMC-TC login) and your password here. The default factory setting for both is "cmc". You must enter your login name (CMC-TC login) and your password. You can change your password later (see 7.3.2 Configuring passwords). Fig. 7 Build connection Select the connection using COM port. Click OK. The properties of the selected COM port are requested once. 4

Operation 7 Fig. 20 HyperTerminal start window If you have been able to establish the connection to the, the HyperTerminal configuration window appears with the configuration menu of the. You can now make the settings of the appropriate for your local conditions. 5

7 Operation 7 Operation 7. Becoming familiar with the menu structure The menu structure of the terminal program has the following form: Network Configuration. IP Configuration.4.2 IP Addr. CMC (DialIn).. IP Address.4.3 IP Addr. Client (DialIn)..2 IP Subnet Mask.4.4 Username (DialIn)..3 IP Def. Gateway.4.5 Password (DialIn)..4 Enable/Disable DHCP.4.6 Callback No. (DialIn)..5 Ethernet Port Settings.4.7 Enable PPP (Dialout).2 SNMP Configuration.4.8 IP Addr. CMC (Dialout).2. Trap Receiver Configuration 6.4.9 IP Addr. Client (Dialout).2.. IP Trap Receiver.4.A Username (Dialout).2..2 Enable/Disable.4.B Password (Dialout).2..3 IP Trap Receiver.4.C Phone Number (Dialout).2..4 Enable/Disable.4.D Modem Type.2..5 IP Trap Receiver.4.E MSN (for ISDN).2..6 Enable/Disable.4.F Modem Baudrate.2..7 IP Trap Receiver.5 SMTP (email) Configuration.2..8 Enable/Disable.5. IP Addr. SMTP Server.2.2 SNMPv IP Access.5.2 SMTP Server Authentication.2.2. SNMPv Manager.5.3 SMTP Server Username.2.2.2 SNMPv Manager.5.4 SMTP Server Password.2.2.3 SNMPv Manager.5.5 email Sender Name.2.2.4 SNMPv Manager.5.6 email Reply to.2.2.5 SNMPv Manager.5.7 email upon Unit Messages.2.2.6 SNMPv Manager.5.8 email Address.2.2.7 SNMPv Manager.5.8. email Address.2.2.8 SNMPv Manager.5.8.2 email Address.2.2.9 SNMPv Manager.5.8.3 email Address.2.2.A SNMPv Manager.2.2.B SNMPv Manager.2.2.C SNMPv Manager.5.8.4 email Address.6 Syslog Configuration.6. IP Addr. Syslog Server.2.3 Read Community.6.2 IP Addr. Syslog Server.2.4 Write Community.6.3 Syslog Facility.2.5 Enable Auth. Traps.6.4 Enable Syslog.2.6 Change SNMP Version.7 System Name.2.7 Default SNMPv3 User Name.2.8 Default SNMPv3 Password.2.9 Confirm SNMPv3 usmuser/passw.8 System Contact.9 System Location.3 NTP Configuration.A Security.3. Enable NTP.A. Change Password User cmc.3.2 IP Addr. NTP Server.A.2 Change Password User admin.3.3 IP Addr. NTP Server 2.A.3 Change HTTP Port.3.4 NTP Offset to UTC.A.4 Enable SSL.3.5 NTP Update Frequency (h).a.5 Change HTTPs Port.3.6 Dayl. Saving Time, Begin.B Enable FTP.3.7 Dayl. Saving Time, End.C Cons./Teln. Timeout Minutes.4 PPP Configuration.D Enable/Disable Telnet.4. Enable PPP (DialIn).E Activate Actual Values 2 Sensors 2. Sensors 2...C Trap Receiver 4/Log 2.. e.g. Temperature Sensor 2...D Alarm Reset 2... Status 2...E Send SMS 2...2 Value 2...F Send email 2...3 High Setpoint 2..2 e.g. Humidity Sensor 2...4 Warning Setpoint 2..3 not available 2...5 Low Setpoint 2..4 not available 2...6 Message Text 2..5 Sensor Unit Name 2...7 Alarm Relay 2..4 Status of Unit 2...8 Beeper 2.2 Unit 2 not available 2...9 Trap Receiver 2.3 Unit 3 not available 2...A Trap Receiver 2 2...B Trap Receiver 3 3 General Configuration 2.4 Unit 4 not available 3. Temperature Unit 3.9.2 SMS Service Number 3.2 Beeper 3.9.3 ISDN MSN 3.3 Quit Alarm Relay 3.9.4 ISDN Pre-Dial Number 3.4 Alarm Relay Options 3.9.5 ISDN Command 3.5 Web Access 3.9.6 SMS upon Unit Message 3.6 Actual Date 3.9.7 SMS Phone Numbers 3.7 Actual Time 3.9.7. SMS Phone Number 3.8 Check Link 3.9.7.2 SMS Phone Number 3.9 SMS Configuration 3.9.7.3 SMS Phone Number 3.9. GSM Card PIN 3.9.7.4 SMS Phone Number 4 Info Page 5 Default, New Config. Of Sensor Units, File Transfer 5. Set General Configuration to Default 5.3. Send File to CMC 5.2 Sensor Unit Detection 5.3.2 Receive File from CMC 5.3 Serial File Transfer (ZModem) Fig. 2 Menu structure

7.2 Operating notes The following sections list all configuration parameters of the as tables. The basic operation is always the same: Use the "up" and "down" arrow keys to navigate within the menu structure. Use the "left" and "right" arrow keys to scroll within fields that have several default values. Enter from the keyboard any required data in fields for text or numeric information. The "Esc" key can be used to cancel your inputs. Press "Return" or "Enter" to confirm all inputs. 7.3 Setting the base configuration You only need to set the network configuration, the alarm relay and the trap receiver for the base configuration. You can make further settings from a browser or using Telnet. 7.3. Network configuration You can use this menu to change your network settings. Main menu Network Configuration IP Configuration IP Address IP Subnet Mask IP Def. Gateway Enable/Disable DHCP Ethernet Port Settings Enter your IP address (factory setting 92.68.0.90). Enter your IP subnet mask address (factory setting 255.255.255.0). Enter the IP for the router (factory setting 0.0.0.0). Set whether the is to obtain the IP address automatically: Enable or disable the function. Configure the network interface of the on your network. Possible settings: Auto, 00/Half, 00/Full, 0/Half, 0/Full Operation 7 A restart must be performed to save the settings: Main menu Network Configuration D Activate Actual Values Activate Actual Values Activate new values: Select "Yes" and press the Return key to perform a restart. If DHCP is enabled, a connection to a DHCP server present in the network will be established during the restart and an IP address obtained from it. If no IP address can be obtained from the DHCP server, the last valid IP address or default address will be used. A restart is also required for disabling DHCP. 7.3.2 Configuring the trap receiver To obtain messages and notifications, so-called trap messages, of the, the IP address of the console on which the management software package (e.g. HP OpenView) is installed, must be entered. The management software must support the SNMP protocol. Main menu Network Configuration 2 SNMP Configuration Trap Receiver Configuration IP Trap Receiver Enable/Disable Enter the IP address of the messages recipient (factory setting 0.0.0.0). Enable or disable the receiving at the receiver located above. Enter any other required receivers (maximum four) in the lines available below. 7.3.3 Configuring SNMPv access Management software that supports SNMP (e.g. HP OpenView or CMC-TC Manager V.5) can access the from the network. To restrict access, you can permit access for specified IP addresses (max. 2). Access is then blocked for all other IP addresses that have not been entered. If no IP address has been entered, any management software in the network has access to the. 7

7 Operation Main menu Network Configuration 2 SNMPv IP Access SNMPv Manager Set the IP address for the PC with the SNMP management software that may access the. 7.3.4 Configuring the read/write community To make the settings for a management software on the, you must set the community of the and the management software. Main menu Network Configuration 2 SNMP Configuration 3 Read Community / 4 Write Community 3 Read Community 4 Write Community Set the Read Community for the trap handling. Press the Backspace key to clear the factory setting and enter the new name. Set the Write Community for the trap handling. Press the Backspace key to clear the factory setting and enter the new name. 7.3.5 Configuring the authentication traps For an SNMP query (read or write) to the Basic CMC with invalid Read/Write Community, the Basic CMC will send an authentication trap to all enabled trap receivers. Main menu Network Configuration 2 SNMP Configuration 5 Enable Auth. Traps Enable Auth. Traps Use the and arrow keys to enable or disable FTP. 7.3.6 Changing the SNMP version As of software version 2.45, the supports two types of SNMP. SNMPv and SNMPv3 are available. SNMPv3 provides more security than SNMPv. An authentication is required for SNMPv3. Main menu Network Configuration 2 SNMP Configuration 6 Change SNMP Version 7 Default SNMPv3 User Name 8 Default SNMPv3 Password Confirm SNMPv3 usmuser/passw Use the and arrow keys to set the SNMPv and SNMPv3. Set the username for cmc SNMPv3 access (max. 20 characters). Press the Backspace key to clear the factory setting and enter the new username. Set the password for cmc SNMPv3 access (max. 20 characters). Press the Backspace key to clear the factory setting and enter the new password. Use the and arrow keys to confirm the SNMPv3 authentication. 7.3.7 Configuring NTP The Network Time Protocol (NTP) is a standard for the time synchronisation of the internal clock over the network. The NTP function synchronises the local, internal clock of the using external time signals obtained from an NTP server. To use this function in the, the network connection to an NTP server must be possible. The IP addresses for two NTP servers (primary and secondary server) can be entered. The time information from the NTP server uses the coordinated world time (UTC) as reference time. The times in the various time zones of the world are derived from this time. For this reason, the current time zone must be set in the menu. The current date and the current time are then represented with the current value taking account of the time zone and the daylight saving setting. Because the begin and end of the daylight saving period differ in the various time zones, these two values can also be set in the. 8

Main menu Network Configuration 3 NTP Configuration Enable NTP Use the and arrow keys to enable or disable NTP. 2 IP Addr. NTP Server 3 IP Addr. NTP Server 2 4 NTP Offset to UTC 5 NTP Update Frequency (h) 6 Dayl. Saving Time, Begin 7 Dayl. Saving Time, End Set the first IP address of the NTP server. Press the Backspace key to clear the factory setting and enter the IP address of the first NTP server. Set the second IP address of the NTP server. Press the Backspace key to clear the factory setting and enter the IP address of the second NTP server. Use the and arrow keys to set your country's time zone. Set the interval how often the should query the NTP server for the current date and clock time. The values must be entered in hours. Press the Backspace key to clear the factory setting and enter the interval time. Enter the begin of the daylight saving period. Press the Backspace key to clear the factory setting and enter the new entry in the following format: m = month (...2) n = week of the month ( = first week, 5 = last week of the month) d = day (0 = Sunday, 6 = Saturday) Enter the end of the daylight saving period. Press the Backspace key to clear the factory setting and enter the new entry in the following format: m = month (...2) n = week of the month ( = first week, 5 = last week of the month) d = day (0 = Sunday, 6 = Saturday) Operation 7 7.3.8 Configuring PPP You can administer the from a remote location using an analogue modem. To do this, connect the modem to the serial interface of the Basic CMC. Main menu Network Configuration 4 PPP Configuration Enable PPP (DialIn) 2 IP Addr. CMC (DialIn) 3 IP Addr. Client (DialIn) 4 Username (DialIn) 5 Password (DialIn) 6 Callback No. (DialIn) 7 Enable PPP (Dialout) 8 IP Addr. CMC (Dialout) 9 IP Addr. Client (Dialout) A Username (Dialout) B Password (Dialout) C Phone Number (Dialout) D Modem Type Use the and arrow keys to enable or disable PPP. Set the IP address of the Basic CMCs to establish a connection from a client to the. Set the IP address of the client to dial-in to the. Set an arbitrary username used for login to the (max. 20 characters). Set an arbitrary username for password used for login to the (max. 20 characters). Enter the telephone number to which the should call back. Use the and arrow keys to enable or disable PPP. Enter the IP address of the for dial-in to the client. Enter the IP address of the client for dial-in to the client. Enter a username as authentication on the client. Note: The username must be entered as user account in the client (max. 20 characters). Enter the password used as authentication on the client. Note: The password must be identical with the password of the user account (max. 20 characters). Enter the telephone number to which the should call in order to send a trap. Select the modem type Analogue, ISDN, GSM (note when a GSM unit is used as modem, the SIM card may not have any 9

7 Operation E MSN (for ISDN) F Modem Baud Rate PIN number). When an ISDN modem is used, the MSN number must be entered. The bit rate used by the serial interface to communicate with the external modem (for an analogue modem). 2 IP Addr. Syslog Server 3 Syslog Facility 4 Enable Syslog Syslog Server 2 to which all alarm and event logs are sent. Specifies the origin of the log message (Local0..Local7). Serves as differentiation when several systems are used. Enables or disables the Syslog function. The default value is "disabled". 7.3.9 Configuring the sending of e-mails As of software version 5.40, the can send alarm messages as e-mail using an SMTP server. 20 Main menu Network Configuration 5 SMTP (email) Configuration IP Addr. SMTP Server 2 SMTP Server Authentication 3 SMTP Server Username 4 SMTP Server Password 5 email Sender Name 6 email Reply to 7 email upon Unit Messages 8 email Address Enter the IP address of the SMTP server. Use the and arrow keys for an authentication (Yes) or (No) on the SMTP server. Enter the username for the SMTP server. Enter the password for the SMTP server. 7.3.0 Configuring Syslog Enter the sender address of the. When a user answers this a- larm message, the response mail will be sent to the entered address. For a timeout, etc. on a unit, an e-mail can be sent as notification. Use the and arrow keys to set "Yes" or "No". Enter up to four different e-mail addresses. Main menu Network Configuration 6 Syslog Configuration IP Addr. Syslog Server Syslog Server to which all alarm and event logs are sent. 7.3. Configuring system name, contact and location A unique name, a contact address (e-mail) and an installation location can be entered for the Basic CMC. Main menu Network Configuration 6 System Name 7 System Contact 8 System Location An arbitrary name can be assigned for the. Press the Backspace key to clear the factory setting and enter the new name. Set the contact address (e.g. xyz@rittal.de). Press the Backspace key to clear the factory setting and enter the new contact address. Enter the name of the installation location. Press the Backspace key to clear the factory setting and enter the new installation location. 7.3.2 Configuring passwords You can change the passwords of the as required. The string length must not exceed 20 characters. Special characters are not permitted. Main menu Network Configuration 9 Security Change Password User cmc Set the password for the cmc user (max. 20 characters). Press the Backspace key to clear the factory setting and enter the new password. To verify the new password, it must be re-entered a second

Operation 7 2 Change Password User admin time. Set the password for the admin user (max. 20 characters). Press the Backspace key to clear the factory setting and enter the new password. To verify the new password, it must be re-entered a second time. Main menu Network Configuration A Enable FTP A Enable FTP Use the and arrow keys to enable or disable FTP. 7.3.3 Changing the HTTP port For some networks, the standard http port is not set to port 80. You can change the port number to meet your needs. Main menu Network Configuration 9 Security 3 Change http Port Set the http port 80-0000 (factory setting: 80). Press the Backspace key to clear the factory setting and enter the new port. 7.3.4 HTTPS (SSL) function For security, the supports SSL encryption. This is used for the secure data exchange between the and the workstation. Main menu Network Configuration 9 Security 4 Enable SSL Use the and arrow keys to enable or disable SSL. 5 Change https Port Set the https port 80-0000 (factory setting: 443). Press the Backspace key to clear the factory setting and enter the new port. 7.3.5 Configuring FTP access The FTP access is used exclusively for downloading software updates, log files and configuration files. It can remain deactivated for normal use. 7.3.6 SFTP access The secure FTP access includes the SSH data encryption. The function is always active and cannot be disabled. SFTP can be used as alternative to FTP. 7.3.7 Configuring the timeout window The console and Telnet timeout window is used for the automatic logout after the set time. If a user, for example, has not performed any work on the Basic CMC within five minutes, he/she will be logged off automatically. Main menu Network Configuration B Cons./Teln. Timeout Minutes B Cons./Teln. Timeout Minutes Set the Timeout function in minutes. 0 = no timeout 5 = when no changes have been made within the previous five minutes. Press the Backspace key to clear the factory setting and enter the new time. 7.3.8 Configuring Telnet access When you use Telnet, you have the same administrative rights as for the serial interface. If access is not to be made using Telnet, you can deactivate it. Main menu Network Configuration C Enable/Disable Telnet C Enable / Disable Telnet Use the and arrow keys to enable or disable Telnet. 2

7 Operation 22 Note! In addition to access using Telnet, an encrypted access to the configuration using an SSH client (e.g. Putty) is possible. In contrast to Telnet access, the SSH access cannot be disabled. 7.3.9 Activating restart You can use this menu item to reboot the Basic CMC after a software crash. Main menu Network Configuration D Activate Actual Values D Activate Actual Values Use the and arrow keys to perform a restart (Yes) or not (No). 7.3.20 Configuring connected sensors The sensors can be configured using Hyperterminal. This method of operation is necessary only when the browser setting has been set to view mode. Main menu 2 Sensor Units -4 connected units Access to the connected units with the installed sensors. 7.3.2 General configuration of the Basic CMC The main configuration of the is used to parameterise the hardware and the sensor units. You can also parameterise the date and time, temperature unit, alarm relay, etc. Main menu 3 General Configuration Temperature Unit Use the and arrow keys to set Celsius or Fahrenheit as unit. 2 Beeper Use the and arrow keys to set the alarm beeper on or off. 3 Quit Alarm Relay Use the and arrow keys to set the alarm relay confirmation. 4 Alarm Relay Options In case of alarm, the "C" key can be used to reset the alarm relay on the. Disabled = the alarm relay will be reset automatically after an alarm. Enabled = the alarm relay will be reset after an alarm by pressing the "C" key. Use the and arrow keys to set the alarm relay function. Close = alarm relay contact is closed. Open = alarm relay contact is open. Off = alarm relay is disabled. 5 Web Access Use the and arrow keys to set the web access. Full = full access. All current values can be displayed and settings changed on the Basic CMC. View = display. Only the current values are displayed. Changes to the settings cannot be made. No = block web access. The can no longer be called from the web. 6 Actual Date Set the current date. Press the Backspace key to clear the factory setting and enter the current date. Date format: dd.mm.yyyy 7 Actual Time Set the current time. Press the Backspace key to clear the factory setting and enter the current time. Time format: hh:mm:ss 8 Check Link The reachability of the individual trap receivers can be tested. Press the Backspace key to clear the factory setting and enter the number of the trap receiver. 9 SMS Configuration True only for connected ISDN or GSM unit.

7.3.22 Configuring SMS notification (GSM unit) This function is active only for connected GSM unit. Main menu 3 General Configuration 9 SMS Configuration GSM Card PIN 2 SMS Service Number 6 SMS upon Unit Messages Set the 4-digit PIN number of the GSM card. Set the SMS service number. The specified format must be used, e.g. +4970760000 A notification SMS can be sent when a timeout, etc., occurs on a unit. Use the and arrow keys to set to "Yes" or "No". 7.3.23 Configuring SMS notification (ISDN unit) This function is active only for connected GSM unit. Main menu 3 General Configuration 9 SMS Configuration 3 ISDN MSN Set the MSN number of your ISDN connection. The number must be entered in the following format: +49/2772/23456 4 ISDN Pre- Dial Number 5 ISDN Command 6 SMS upon Unit Messages Set the telephone number to obtain an external line. This is necessary when the ISDN unit is connected to a telephone system. Set the SMS command for sending an SMS over the telephone fixed-line network. For example, "8888 ANMELD" for the T-Com network. Or "09003266900" for the Arcor German network. A notification SMS can be sent when a timeout, etc., occurs on a unit. Use the and arrow keys to set to "Yes" or "No". Operation 7 7.3.24 Entering the telephone numbers for SMS notification This function is active only for connected ISDN or GSM unit. Main menu 3 General Configuration 9 SMS Configuration 7 SMS Phone Numbers - 4 SMS Phone Number Set the SMS destination telephone number. For example: +492772505234 7.3.25 Calling the information page To display the current information for the Basic CMC, you can display an information page about the. This page displays all settings for the network connection, the software and hardware version, etc. Main menu 4 Info Page 4 Info Page The CMC Info Page shows a complete overview of the configuration of the. 7.3.26 Resetting all settings in the main menu You can reset all your sensor settings. Passwords and network settings will not be reset. Main menu 5 Default, New Config. of Sensor Units, File Transfer Set General Configuration to Default Use the and arrow keys to activate (Yes) or not activate (No) the sensor settings. 23

7 Operation 7.3.27 Manual search for sensors Under some circumstances, the sensors will not be detected immediately. In this case, you can activate a manual search for the sensors. Main menu 5 Default, New Config. of Sensor Units, File Transfer 2 Sensor Unit Detection Use the and arrow keys to activate (Yes) or not activate (No) the sensor detection. 7.4 Transferring files using the serial interface You can use the serial interface to transfer individual files to the. Main menu 5 Default, New Config. of Sensor Units, File Transfer 3 Serial File Transfer (ZModem) Send File to CMC Use the and arrow keys to start (Yes) or not start (No) the Zmodem. 7.6 Access using a browser Call your web browser as usual. Enter the IP address of the in the address bar and call the page. 7.6. Login 2 3 Fig. 22 Login window Key: Username 2 Password 3 Login or Clear button In the login window, enter the http user name and the http password of the. Factory setting: Username: admin Password: admin To confirm the input, click the Login button. To clear the input, click the Clear button. You will now be requested to specify the path for the file to be transferred. To do this, click "Search" and search for the file. Select Zmodem as protocol and click "Send". Once the file has been transferred, press the Esc key several times to return to the main menu and to save the setting. 7.5 Saving files using the serial interface You can save individual files on your PC. 7.6.2 Main page view 2 3 4 5 6 7 8 Main menu 5 Default, New Config. of Sensor Units, File Transfer 3 Serial File Transfer (ZModem) 2 Receive File from CMC Enter the name of the Basic CMC file that you want to save on your computer. Now use the Search icon to select a destination folder for the file to be saved. Remove ZModem as receive protocol and click "Receive" to confirm your input. Fig. 23 Main page view Key: Status window As shown above 2 IP address of the 3 Link to the main page view 4 Setup link 5 Alarm and event logging link 6 Administration link 7 Username 8 User logout 24

The following buttons are provided to simplify the navigation between the individual pages: Setup button: Links from the overview page (main or units overview) to the setup pages of the associated unit. Overview button: Links from the main overview page to the units overview page. Back button: This button can be used to go back one page from any page. Home button: Links directly to the main page from any units overview page or from the setup pages. 7.6.3 Operation 7 25

7 Operation 2 3 4 5 6 7 8 9 26 Main settings Fig. 24 Main settings Key: General This link can be used to make fundamental settings on the (name, location, contact name, temperature unit, beeper, alarm relay confirmation, alarm relay options, background colour, date and time). 2 Timer function (see 7.6.4 Configuring the scheduler). 3 SMS unit (see 7.6.5 GSM Unit or 7.6.6 Configuring ISDN Unit). 4 email (SMTP). 5 Event Logging (see 7.6.8 Viewing the log file). 6 Administration linked to the user administration provided you are logged in as administrator. Otherwise you can only change your own password. 7 Date and time of the last alarm/warning status change. 8 Current status of the alarms and warnings. 9 Logged in user. 7.6.4 Configuring the scheduler You can program a maximum of eight timers.. Specify whether the timer is to be active or inactive. 2. Select the day or days on which the timer is to be active. 3. Specify the time window (format: hh:mm). 4. Specify what the timer is to perform during this time. The following functions can be selected from item 4: Description Disable Trap Receiver Disable SMS (General) Alarm Scheduler Function No alarms are sent to the trap receiver. Deactivates the SMS notification function. Deactivates the alarms configured for "Scheduled Alarm off" in the sensor configuration. Disable SMS Receiver Disable e-mail Rec. Status e-mail to Rec. Deactivates the SMS notification function for a specific recipient. Deactivates the e-mail notification function for a specific receiver. Sends a status e-mail to a recipient. A maximum of 50 messages are transferred for each status mail. If more than 50 messages are present, only the most recent 50 will be sent in the e-mail. 7.6.5 Configuring the GSM unit 2 3 4 5 Fig. 25 Setup for SMS unit Key: GSM Card PIN Enter here the PIN for your GSM card. 2 GSM Service Centre Set the service centre number. This differs depending on the mobile telephone system provider. Observe the notation (e.g. +4970760000). 3 Unit Messages Set whether for a unit error, e.g. timeout or configuration change, an SMS is to be sent. 4 Enter the destination telephone numbers (max. four destination telephone numbers, e.g. +492772505234). 5 Accept or Reset button Accept or reset the settings.

Operation 7 7.6.6 Configuring the ISDN unit 2 3 4 5 6 Fig. 26 Setup for ISDN unit Key: ISDN MSN Enter here the MSN number of the ISDN connection. The MSN number must be entered in the following format: +49/2772/23456 2 ISDN Pre Dial If the ISDN unit is to be connected to a telephone system, you must, for example, enter a "0" to obtain an external line. 3 ISDN Command Specify the SMS command so that an SMS can be sent over the fixed-line network (for example, the following command must be specified for T-Com: "8888 ANMELD"). 4 Unit Messages Set whether for a unit error, e.g. timeout or configuration change, an SMS is to be sent. 5 Phone Number - 4 Enter here the destination telephone numbers that are to receive an SMS should an alarm occur; the following format must be used: +49277223456. 6 Accept or Reset button Accept or reset the settings. 7.6.7 Configuring the sending of e-mails If you have not yet used Hyperterminal to enter the e-mail addresses of the alarm recipients, you can do this here. Proceed as follows. 2 3 4 5 6 7 8 Fig. 27 Setup for sending e-mails 27

7 Operation Key: SMTP Server IP Enter here the IP address of the SMTP server. 2 SMTP Authent. If your SMTP server requires a username and password for authentication, click "Yes". 3 Server Username Enter the username for authentication. 4 Server Password Enter the password of the server used for authentication and repeat the input in the Retype field. 5 Sender Name Enter a sender name. This name is then specified as sender in the alarm mail. 6 Reply to If a reply to the alarm mail is required, you can specify an e-mail address to which recipient the response mail is to be forwarded. 7 Unit Messages If the individual units are to display an error message (configuration change, timeout), you can send this alarm as mail. To do this, click "Yes". 8 E-Mail Address -4 Enter here a maximum of four different e-mail addresses. Click the "Accept" button to accept and save the settings. 7.6.8 Viewing the log file Two different types of logging are performed. The first is the "Alarm Log". This displays all alarms that the logged-in user is allowed to view. Fig. 28 28 Alarm Log The other is the "Event Log". This displays which user logged in and logged out at what time, when an update occurred, when a file was uploaded or downloaded, and various other events. Fig. 29 Event Log A maximum of 00 messages are recorded. If the memory is full with 00 messages and a new message arrives, the oldest message will be deleted. 7.6.9 Administration Login as administrator on the login page (see 7.6. Login). 2 3 4 5 6 7 8 9 0 2 Fig. 30 User administration Key: Page title 2 User page A maximum of 6 different users or user groups can be defined (max. 20 characters; special characters are not permitted). 3 Username Enter the username or group name. Maximum number of characters: 20 characters (special characters are not permitted). 4 Password Password input: Up to 20 characters permitted (special characters are not permitted). 5 with 4 sensors / voltage cards The access rights are defined on the individual units for each user or user group. No Access: The user has no access to the unit. Read: The user receives only read rights. Settings cannot be changed. Read/Write: The user receives read and write rights, and has access to the unit, and can read and change the settings but not switch the unit 4. Read/Write/Switch: The user receives read, write and switching rights. Connected power socket strips and digital and analogue inputs/outputs can be used by the user. 6 General Setup No Access: The user has no access to the unit. Read: The user receives only read rights. Settings cannot be changed. Read/Write: The user receives read and write rights, and has access to the associated setup web page, and can read and change the settings. 7 Timer Functions No Access: The user has no access to the unit. Read: The user receives only read rights. Settings cannot be changed. Read/Write: The user receives read and write rights, and has access to the timer web page, and can read and change the settings.

8 SMS Setup No Access: The user has no access to the SMS Setup web page. Read: The user receives only read rights. Settings cannot be changed. Read/Write: The user receives read and write rights, and has access to the web page, and can read and change the settings. 9 Alarm Logs No Access: The user has no access to the Alarm Logging page. Own alarms: If a user has only access to one or more units, the user will see only the alarm messages of the associated assigned units. All alarms: The logged in user can view all alarm messages. 0 Timeout If a user does not perform any activity in the browser window for an extended period of time, the user will be logged off from the system after the specified time. Login Status If you are logged in as administrator, you can log off logged-in users. 2 Accept/Reset button Accept button: Settings will be accepted. Reset button: Settings will not be accepted. Operation 7 Key: Number and type of the I/O unit / Voltage unit. 2 Name of the sensor unit: Click to switch to the sensor overview (7.7.2) of the I/O unit. 3 Warning or alarm status of the sensor Green: no warning/alarm Yellow: warning Red: alarm (malfunction) Unit detected: new extension unit has been connected to the Configuration changed: new sensor has been registered on the or configuration change of a sensor. 4 Acknowledge events Click the Clear button to confirm timeouts and configuration changes. This requeries the and updates the web page. 5 Refresh Forces the immediate update of the web page. The overview will also be updated automatically every ten seconds. Note! If you are logged in as user, you can only change your password in the Administration window. Logged-in users can only change their own password. 7.7 Configuring the sensors You can make various settings for each sensor. The has four connections. One sensor can be connected to each connection. 7.7. General overview (status window) 2 3 4 5 Fig. 3 I/O units overview 29

7 Operation 7.7.2 Sensor overview 2 3 4 5 6 Fig. 32 Sensors overview on the Key: Connection number and sensor type. 2 Message text of the sensor. Can be selected freely using the sensor configuration (7.7.3). 3 Status or measured value of the sensor. The font colour indicates the status of the sensor. For analogue values, an arrow also indicates the over- or undershooting of the alarm or warning thresholds. 4 Acknowledge events Click the Clear button to confirm timeouts and configuration changes. This requeries the and updates the web page. 5 Refresh Forces the immediate update of the web page. The sensor overview is also updated automatically every ten seconds. 6 Warning or alarm status of the sensors (overall) Green: no warning/alarm Yellow: warning Red: alarm (malfunction) 7.7.3 General overview (sensor configuration) You can individually set the connected sensors. The structure of the configuration overview is generally always identical and shown here as example. To reach this page, click the message text of the sensor or the tool icon on the general overview (status window) of the. 2 3 4 5 6 7 8 9 0 2 3 4 5 30 Fig. 33 Configuring sensor overview

Operation 7 Key: Connected sensor type 2 Current status of the connected sensor 3 This information text will also be transferred when a warning/alarm message is sent; it also serves as information for the recipient of the message to identify the sensor. You can delete the specified text and add your own information text (e.g. TempSensorRack). 7 You can set for each sensor whether (enable) or not (disable) the alarm relay should be switched when an alarm occurs. 8 You can set for each sensor whether (enable) or not (disable) the integrated alarm beeper should be activated when an alarm occurs. 9 You can set for each sensor type whether after a warning or alarm status the should be acknowledged automatically (Auto) or be acknowledged manually by the administrator (Manual). 0 You can click the individual option fields to specify to which of the entered trap receiver the traps for this sensor will be sent. Click the individual option fields to set which alarm configuration is to be activated or deactivated. You can specify the individual functions from the "Setup Timer" menu item and assign the associated schedulers. 2 You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS- Unit; each number is separated with an ampersand 3 You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand "&", e.g. &2&3&4. 4 Accept all changes. 5 Reset all settings to the default values. The following buttons are provided to simplify the navigation between the individual pages: Back button: This button can be used to go back one page from any page. Home button: Links directly to the main page from any units overview page or from the setup pages. 3

7 Operation 7.7.4 Configuring the temperature sensor The temperature sensor (DK 7320.500) is configured as follows: 32 Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text High Setpoint Warning Setpoint Low Setpoint Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Sensor type. Will be detected automatically. Measured temperature and sensor status. Green = OK, yellow = warning, red = alarm Message text also transferred when a warning/alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "TempSensor Rack0". Temperature limit which when exceeded causes an alarm message to be issued. Temperature limit which when exceeded causes a warning message to be issued. Temperature limit which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued. Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile Send email Accept Reset telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.5 Configuring the humidity sensor The humidity sensor (DK 7320.50) is configured as follows: The humidity is specified as relative humidity (% rh). Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text High Setpoint Warning Setpoint Low Setpoint Relay Alarm Beeper Alarm Sensor type. Will be detected automatically. Measured humidity and sensor status. Green = OK, yellow = warning, red = alarm Message text also transferred when a warning/alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Humidity Rack0". Humidity limit which when exceeded causes an alarm message to be issued. Humidity limit which when exceeded causes a warning message to be issued. Humidity limit which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued.

Operation 7 Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Reset Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.6 Configuring the analogue sensor input module The analogue sensor input module (DK 7320.520) is configured as follows: The individual values are specified as percentage. Main menu Setup Click sensor name n Connection number of the sensor. High Setpoint Warning Setpoint Low Setpoint Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email tion that uniquely identifies your sensor, e.g. "Analogue sensor Rack". Input current limit which when exceeded causes an alarm message to be issued. Input current limit which when exceeded causes a warning message to be issued. Input current limit which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued. Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Type Sensor Status Sensor type. Will be detected automatically. Measured input current as percentage and sensor status. Green = OK, yellow = warning, red = alarm Accept Reset Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. Message Text Message text also transferred when a warning/alarm message is sent. Enter here a designa- 33

7 Operation 7.7.7 Configuring the access sensor The access sensor (DK 7320.530) is configured as follows: 34 Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor type. Will be detected automatically. Sensor Status Access sensor status. Green = OK, red = alarm Message Text Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Message text also transferred when a warning/alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Access sensor Rack ". a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued. Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset Reset all settings to the lastsaved values; changes are not accepted. 7.7.8 Configuring the vandalism sensor The vandalism sensor (DK 7320.540) is configured as follows: The individual values are specified as pulses. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text High Setpoint Warning Setpoint Low Setpoint Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Sensor type. Will be detected automatically. Measured pulses and sensor status. Green = OK, yellow = warning, red = alarm Message text also transferred when a warning/alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Vandalism Rack ". Pulse limit which when exceeded causes an alarm message to be issued. Pulse limit which when exceeded causes a warning message to be issued. Pulse limit which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued. Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration

Alarm Off Send SMS Send email Accept Reset should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.9 Configuring the air flow sensor The air flow sensor (DK 7320.550) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Sensor type. Will be detected automatically. Air flow status and sensor status. Green = OK, red = alarm Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Airflow Rack0". an alarm should switch an alarm relay. an alarm should cause a signal to be issued. Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the alarm messages Scheduled Alarm Off Send SMS Send email Accept Reset Operation 7 should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.0 Configuring the smoke detector The smoke detector (DK 7320.560) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text Relay Alarm Beeper Alarm Sensor type. Will be detected automatically. Smoke detector status and sensor status. Green = OK, red = alarm Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Smoke detector Rack0". an alarm should switch an alarm relay. an alarm should cause a signal to be issued. 35

7 Operation Reset Alarm Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). 36 Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Reset Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7. Configuring the motion sensor The motion sensor (DK 7320.570) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text Sensor type. Will be detected automatically. Motion sensor status and sensor status. Green = OK, red = alarm Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Motion sensor Rack0". Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Reset an alarm should switch an alarm relay. an alarm should cause a signal to be issued. Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.2 Configuring the digital input module The digital input module (DK 7320.580) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor type. Will be detected automatically.

Operation 7 Sensor Status Input status and sensor status. Green = OK, red = alarm 7.7.3 Message Text Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Dig. input Rack0". Relay Alarm an alarm should switch an alarm relay. Beeper Alarm an alarm should cause a signal to be issued. Reset Alarm Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Trap Receiver Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Scheduled Alarm Off Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. Send SMS You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand Send email You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept Accept the changes. Reset Reset all settings to the lastsaved values; changes are not accepted. 37

7 Operation Configuring the digital relay output module The digital relay output module (DK 7320.590) is configured as follows: Only the status of the sensor is specified. 38 Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor type. Will be detected automatically. Output Status Relay output status; enabled = on, disabled = off Message Text Delay Timeout Trap Receiver Send SMS Send email Combinations Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Dig. output Rack0". Delay time before switching on or off again. 0 s = no initiation time; 999 s = 999 seconds initiation time. Module behaviour in case of failure of the provided the module itself is still supplied with power: stay = after expiration of the time, return to the original state; switch off = after expiration of the time, the output will be switched off; switch on = after expiration of the time, the relay will be switched on. Set to which of the entered trap receivers the status messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Switch Output Accept Reset Configure the switching combinations (see 7.7.4 Configuring switching combinations for the digital relay output module). Manual switch on (On) or switch off (Off). Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.4 Configuring the switching combinations for the digital relay output module The switching combination for the digital relay output module (DK 7320.590) is configured as follows: Various switching combinations can be set. Main menu Setup Click sensor name Switching combinations If status of is and/or status of is Then...output Accept Reset Select the first sensor for the switching combination. Select the first sensor state for a switching operation. Select an "and" or "or" operation Select the second sensor for the switching combination. Select the second sensor state for a switching operation. Select the switching state when the switching combination is satisfied. Switch off = disable relay output; switch on = enable relay output. Accept the changes. Reset all settings to the lastsaved values; changes are not accepted.

Operation 7 7.7.5 Configuring the voltage monitor The voltage monitor (DK 7320.600) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Sensor type. Will be detected automatically. Input state and sensor status. Green = OK, red = alarm Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Volt.Rack0". an alarm should switch an alarm relay. an alarm should cause a signal to be issued. Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. 39

7 Operation Reset Reset all settings to the lastsaved values; changes are not accepted. 7.7.6 Configuring the voltage monitoring for the voltage monitor with IEC switching output The voltage monitor with IEC switching output (DK 7320.60) is configured as follows: The individual values are specified in volts. 40 Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text High Setpoint Warning Setpoint Low Setpoint Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Sensor type. Will be detected automatically. Measured voltage and sensor status. Green = OK, red = a- larm Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Volt.Rack0". Voltage limit which when exceeded causes an alarm message to be issued. Voltage limit which when exceeded causes a warning message to be issued. Voltage limit which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued. Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Scheduled Alarm Off Send SMS Send email Accept Reset Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.7 Configuring the switching output for the voltage monitor with IEC switching output The switching output for the voltage monitor with IEC switching output (DK 7320.60) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor type. Will be detected automatically. Output Status Relay output status; enabled = on, disabled = off Message Text Delay Timeout Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Volt.Rack0". Delay time before switching on or off again. 0 s = no initiation time; 999 s = 999 seconds initiation time. Module behaviour in case of failure of the provided the module itself is still supplied with power: stay = after expiration of the

Trap Receiver Send SMS Send email Combinations Switch Output Accept Reset time, return to the original state; switch off = after expiration of the time, the output will be switched off; switch on = after expiration of the time, the relay will be switched on. Set to which of the entered trap receivers the status messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Configure the switching combinations (see 7.7.8 Configuring switching combinations for the voltage monitor with IEC switching output). Manual switch on (On) or switch off (Off). Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.8 Configuring the switching combinations for the voltage monitor with IEC switching output The switching combination for the voltage monitor with IEC switching output (DK 7320.60) is configured as follows: Various switching combinations can be set. Main menu Setup Click sensor name Switching combinations If status of is Select the first sensor for the switching combination. Select the first sensor state for a switching operation. and/or status of is Then...output Accept Reset Operation 7 Select an "and" or "or" operation Select the second sensor for the switching combination. Select the second sensor state for a switching operation. Select the switching state when the switching combination is satisfied. switch off = disable switching output; switch on = enable switching output. Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.9 Configuring the voltage monitoring for the voltage monitor with 6 A switching output The voltage monitor with 6 A switching output (DK 7320.6) is configured as follows: The individual values are specified in volts. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text High Setpoint Warning Setpoint Low Setpoint Relay Alarm Sensor type. Will be detected automatically. Measured voltage and sensor status. Green = OK, yellow = warning, red = alarm Message text also transferred when a warning/alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Volt.Rack0". Voltage limit which when exceeded causes an alarm message to be issued. Voltage limit which when exceeded causes a warning message to be issued. Voltage limit which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. 4

7 Operation Beeper Alarm a warning/alarm should cause a signal to be issued. Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Reset Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.20 Configuring the switching output for the voltage monitor with 6 A switching output The switching output for the voltage monitor with 6 A switching output (DK 7320.6) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor type. Will be detected automatically. Output Status Relay output status; enabled = on, disabled = off. Message Text Delay Timeout Trap Receiver Send SMS Send email Combinations Switch Output Accept Reset Message text also transferred when a status message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Volt.Rack0". Delay time before switching on or off again. 0 s = no initiation time; 999 s = 999 seconds initiation time. Module behaviour in case of failure of the provided the module itself is still supplied with power: stay = after expiration of the time, return to the original state; switch off = after expiration of the time, the output will be switched off; switch on = after expiration of the time, the relay will be switched on. Set at which of the entered trap receivers, the status messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Configure the switching combinations (see 7.7.2 Configuring switching combinations for the voltage monitor with 6 A switching output). Manual switch on (On) or switch off (Off). Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 42

7.7.2 Configuring the switching combinations for the voltage monitor with 6 A switching output The switching combination for the voltage monitor with 6 A switching output (DK 7320.6) is configured as follows: Various switching combinations can be set. Main menu Setup Click sensor name Switching combinations If status of is and/or status of is Then...output Accept Reset Select the first sensor for the switching combination. Select the first sensor state for a switching operation. Select an "and" or "or" operation. Select the second sensor for the switching combination. Select the second sensor state for a switching operation. Select the switching state when the switching combination is satisfied. switch off = disable switching output; switch on = enable switching output. Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.22 Configuring the 48 V voltage monitor The 48 V voltage monitor (DK 7320.620) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text Sensor type. Will detected automatically. 48 V voltage monitor state and sensor status. Green = OK, red = alarm. Message text also transferred when a warning/alarm message Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Reset Operation 7 is sent. Enter here a designation that uniquely identifies your sensor, e.g. "48 V Volt. Rack0". an alarm should switch an alarm relay. an alarm should cause a signal to be issued. Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.23 Configuring the leak sensor The leak sensor (DK 7320.630) is configured as follows: Only the status of the sensor is specified. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor type. Will be detected 43

7 Operation Sensor Status Message Text Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Send email Accept Reset automatically. Leak sensor state and sensor status. Green = OK, red = a- larm. Message text also transferred when an alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Leak Rack0". an alarm should switch an alarm relay. an alarm should cause a signal to be issued. Whether or not an alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.7.24 44

Configuring the acoustic sensor The acoustic sensor (DK 7320.640) is configured as follows: Various limit values can be specified as percentage. Main menu Setup Click sensor name n Connection number of the sensor. Type Sensor Status Message Text High Setpoint Warning Setpoint Low Setpoint Relay Alarm Beeper Alarm Reset Alarm Trap Receiver Scheduled Alarm Off Send SMS Sensor type. Will be detected automatically. Measured noise level as percentage and sensor status. Green = OK, yellow = warning, red = alarm Message text also transferred when a warning/alarm message is sent. Enter here a designation that uniquely identifies your sensor, e.g. "Acoustic Rack0". Noise level limit as percentage which when exceeded causes an alarm message to be issued. Noise level limit as percentage which when exceeded causes a warning message to be issued. Noise level limit as percentage which when undershot causes an alarm message to be issued. a warning/alarm should switch an alarm relay. a warning/alarm should cause a signal to be issued. Whether or not a warning/alarm should be acknowledged automatically (Auto) or must be acknowledged by the administrator (Manual). Set to which of the entered trap receivers the warning/alarm messages should be sent. Enter the trap receivers at 7.3.2 Configuring the trap receiver. Set which alarm configuration should be enabled or disabled. The individual functions can be specified from the "Setup Timer" menu item. You can enter up to four mobile telephone numbers that you Send email Accept Reset Operation 7 have entered previously from Setup SMS-Unit; each number is separated with an ampersand You can enter up to four e-mail addresses that you have entered previously from Setup email (SMTP); each address is separated with an ampersand Accept the changes. Reset all settings to the lastsaved values; changes are not accepted. 7.8 Access using Telnet You can also configure the s using Telnet. This requires that you are permitted to have access with the terminal program using Telnet (see 7.3.8 Configuring Telnet access). 7.8. Login using Telnet This section describes access using Telnet with Windows. a. Open the command prompt and enter the following command: telnet <IP-address> b. Press "Return" or "Enter" to confirm. c. Enter for "login" the Telnet login (factory setting: cmc ). Press "Return" or "Enter" to confirm. d. Enter for "Password" the Telnet password (factory setting: `cmc`). Press "Return" or "Enter" to confirm. 7.8.2 Telnet main menu After login using Telnet, the same main menu as for access using Hyperterminal appears. Because the procedure is similar, consult Section 7.. Note! In addition to access using Telnet, an encrypted access to the configuration using an SSH client (e.g. Putty) is possible. In contrast to Telnet access, the SSH access cannot be disabled. 45

7 Operation 7.9 Perform a software update. Download from the www.rimatrix5.com (Security) internet page in the download area, the software update for the to your PC. Unpack the file into a separate folder, e.g. with the name: basicupdate Note! The update takes approximately ten minutes. Also refer to the update guidelines that the update makes available for download in the internet. Caution! The update must not be interrupted, because otherwise a complete failure of the can result. Open the command prompt and navigate to the folder that contains the unpacked software update. Enter the following command: update <IPaddress> (e.g. update 92.68.0.30). The must be reachable in the network using the entered IP address. The file will now be sent to the. This is displayed with several #-characters in the command prompt window. The automatically performs two restarts during the update process. The process takes several minutes. Do not change anything on the CMC- TC. Do not disconnect the from the mains. Wait until the Operation LED illuminates again and the message described in the Update guide appears. 7.0 Error messages Operation/Alarm LED off Cause Power pack not connected Power pack defective Missing power supply booting Rectification Connect power pack. Replace the defective power pack with an operational one. Establish the power supply. Wait several minutes until the LED illuminates. 46

Link/Traffic LED off Cause Network connection missing Incorrect IP address Incorrect subnet mask Incorrect gateway address Rectification Connect RJ-45 network cable. Check the IP address. Check the subnet mask. Check the gateway address. No access authorisation using Telnet Cause Telnet access blocked for the Incorrect IP address entered Incorrect username entered Incorrect password entered Rectification Activate Telnet access using Hyperterminal. Check the IP address. Check the username. Check the password. Operation 7 SNMP does not send (or traps do not arrive) Cause The read and write community entries are not set correctly Trap receivers have not been entered Rectification Use Hyperterminal or Telnet to compare the read and write authorisation with that of the management software. Check the trap receivers. Sensor not detected or not displayed Cause Sensor not contained in the software Sensor defect Sensor not connected Rectification Perform a software update. Replace sensor. Connect sensor; possibly remove and reinsert the sensor several times. In seldom cases, it can help short-term to insert another sensor and then change back to the first sensor. No access authorisation using the browser Cause Incorrect username entered Incorrect password entered Rectification Check the username. Check the password. No access authorisation using Hyperterminal Cause Incorrect username entered Incorrect password entered Rectification Check the username. Check the password. No setting capability using the browser Cause Web access set only to read authorisation Rectification Set the access authorisation using Hyperterminal or Telnet in the Web access menu item. Alternatively, the administrator must set the appropriate rights for the user in the web interface. 7. Structural layout of the MIB of the Only the device-typical part of the MIB of the Basic CMC (CMC-TC.MIB) is described briefly here. This area of the MIB, in particular, must take account of the system concept of the CMC-TC system. For this reason, the related information that applies to the sensors/actuators and the CMC 7200.520 expansion unit is shown, mainly in table structure. Depending on the sensor / CMC 7320.520 expansion unit, a table for the sensors, the outputs/actuators and the messages is provided. A maximum of four sensors and two CMC extension units (7320.520) can be connected to the Basic CMC. The number of table rows differs depending on the table type and depends on the maximum number of sensor unit ports that can be assigned. Note that the number of possible sensors, outputs and messages is stored in a dedicated MIB variable. 47

7 Operation Sensors: Outputs: Note! The numbers in column 2 correspond to the port numbers of the sensor port. The sensors are assigned in accordance with their physical connection. Outputs are not displayed in this table, refer to the following table. 7.2 Saving and transferring the configuration files This function can be used to save the configuration and, if necessary, restore it on the system later. The configuration can also be transferred to other s that are wired and structured identically. Note! This function may be used only when the s are identical with regard to: - Sensor types and the used ports - Sensor units, and the used ports and addresses - Software versions No sensors / sensor units may be missing or connected in a different order. If this restriction is not observed, the Basic CMC system will not accept the configuration. Messages: Note! The numbers in column 2 correspond to the port numbers of the sensor port. The displayed outputs correspond to their physical connection on the port. Note! The numbers in column 2 correspond to the port numbers of the sensor port. The displayed table entries correspond to the current status and the configuration settings for the port. Representation of the general setup table and sample table entries Another table shows the general setup settings shown below. Saving configuration files: When the commissioning, installation and the setting of all text, limit values, links, network setting, etc., has been completed, this information will be saved on an external system (network PC). The FTP or SFTP protocol can be used to establish an access to the Download directory in the Basic CMC. The three files can be loaded there and saved on the network PC. cmc.cfg (not editable) system data cmc.user (not editable) data of the user administration net.cfg (editable) network settings The changes are accepted immediately after the file has been transferred. The correctness of the acceptance can be seen in the event log. Note! When the net.cfg file is edited, under no circumstances may the format or the file structure be changed. The nonobservance can cause a complete system failure. Transferring configuration files: Prerequisite -> The three configuration files have been saved previously. The FTP or SFTP protocol can be used to establish an access to the Upload directory in the Basic CMC. 48

Maintenance and cleaning 8 The following configuration files are transferred to the target device: cmc.cfg (not editable) installation data cmc.user (not editable) data of the user administration net.cfg (editable) network settings 8 Maintenance and cleaning The Rittal does not require any maintenance. The housing does not need to be opened during the installation or during operation. Note! Opening the housing or the accessory components voids any warranty or liability claims. 9 Storage and disposal 9.. Storage If the device is not being used over a longer period, we recommend that it be removed from the power supply and protected from humidity and dust. Further information concerning the operating conditions is contained in the technical specifications. 9..2 Disposal Because the consists mainly of the housing and circuit board components, the device should be sent for disposal to the electronic recycling when it is no longer required. 8.. Cleaning Caution! Danger of damage! Do not use any aggressive materials, such as white spirits, acid, etc., for cleaning because they can damage the device. Use a lightly dampened cloth for cleaning the housing. 49

0 Changes from software version 5.6 0 Changes from software version 5.6 A number of changes and new functions have been implemented in various areas of the from software version 5.6. These amendments are documented in this chapter. 0. Language selection for the browser interface The menu item Setup > General > Language (German: Einstellung > Allgemein > Sprache) permits you to switch between the English and German versions of the browser interface. This language setting is used not only for the browser interface, but also for log files, e-mail texts, SMS texts and the display output. Key Group : Combination of the first two sensors. The sensors and logic operation can be chosen freely using any of the connected sensors. 2 Group 2: Combination of sensors 3 and 4. The sensors and logic operation can be chosen freely using any of the connected sensors. 3 Combination of the two groups (AND/OR operation). The final result then controls triggering of the action. In this example, the door is unlocked. 0.3 New functions for the alarm and event log Two new functions have been added to the alarm and event log (see Chapter 7.6.8): Delete and Refresh. 0.2 Extended options under Combinations Switching combinations, e.g. for the digital relay output module (see Chapter 7.7.4), were in the past limited to combinations of two sensor values. From software version 5.6, it is possible to define logical combinations of up to four sensors. To this end, the sensors are first configured in two groups of two sensors each. These groups can then be combined by way of a further AND or OR operation. 2 Fig. 35 Alarm and event log Key Delete button: Deletes all entries from the log. 2 Refresh button: Refreshes the log page and displays the latest log entries. 2 0.4 Test functions for traps, e-mail, SMS and pings The alarm simulation menu is called via the menu item Administration > Admin > Simulation. It is here possible to test the e-mail, SMS and trap functions, and to send a ping to a specified IP address. 3 Fig. 34 Extended Combinations configuration 2 3 4 Fig. 36 Alarm simulation menu 50

Changes from software version 5.6 0 Key Sends a test e-mail to all e-mail addresses entered under Setup > Email 2 Sends a test SMS to all telephone numbers entered under Setup > SMS-Unit 3 Sends a test trap to all entered and enabled trap receivers (see Chapter 7.3.2) 4 Sends a ping to the specified IP address 2 3 0.5 Scaling of the 4...20 ma sensor inputs of the input module In the settings for the analog sensor input module 7320.520, it is now possible to define start and end values for automatic scaling of the output. In other words, you can specify which measurement values are to correspond to an input of 4 ma or 20 ma. During operation, the then converts the current input value accordingly before outputting the corresponding measurement value. It is furthermore possible to specify the unit to be displayed with the measurement values. This serves to simplify evaluation and improves display clarity when using this universal sensor option. 4 5 Fig. 37 Server shutdown configuration 6 0.6 Server shutdown function The function Setup > Shutdown can be used to shut servers down conditionally via the. The prerequisite is that an RCCMD client must be installed on the target servers. Note! The installation file for the RCCMD client can be downloaded from www.rimatrix5.com under Service&Support > Downloads. A 30-day test licence is also available there. Key Tabs for the 4 server groups. Each group controls up to 0 servers. 2 Group : Combination of the first two sensors. The sensors and logic operation can be chosen freely using any of the connected sensors. 3 Group 2: Combination of sensors 3 and 4. The sensors and logic operation can be chosen freely using any of the connected sensors. 4 Combination of the two groups (AND/OR operation). The final result then triggers the shutdown of the server group. 5 Each line contains settings for one server. Server Name: Freely chosen server name. IP Address: IP address of the server. Port: Port used to communicate with the RCCMD client (default: 6003). Delay: Delay in seconds before the shutdown command is sent to the server when the switching conditions are met (point 4). Enable: If this check box is marked, the server is shut down if the switching conditions are met (point 4). In addition, the connection to this server will be tested when the Test button (point 6) is clicked. 6 Test button to test the connections to the servers. 5

0 Changes from software version 5.6 Note! The Test button does not send shutdown commands to the servers! It merely checks whether communication with the specified servers is possible. This test is performed for all the servers on all four tabs for which the Enable check box is marked. 0.8 Delayed alarms To prevent a warning or alarm being issued in case of insignificant short-time fluctuations, it is possible to define a delay time for each sensor. A maximum of four sensor values, configured in two groups as for the general switching combinations (see chapter 0.2), can be used to shut the servers down on the basis of defined conditions. The tabs to 4 permit the configuration of four server groups. Within each group, up to 0 servers can be sent a shutdown command on the basis of the specified sensor conditions. The conditions must be defined individually for each server group. 0.7 Configuration of automatic door opening Fig. 38 shows the configuration screen for the Automatic Door Opening Control Unit 7320.790. Observe also the instructions given in the user manual enclosed with the unit. 2 3 4 Fig. 38 52 Configuration of automatic door opening Key Current status of the door control. 2 Time for which the contact remains open upon opening before switching back to the status closed. 3 Timeout response of the door control. Stay: Current status is maintained Open: Door control opens Close: Door control closes 4 Manual switching of the door control. It is necessary to confirm the action by clicking on Accept Fig. 39 Configuration of delayed alarms Key Alarm Delay: Delay between exceeding of the threshold value and actual issuing of an alarm. The time must be specified in seconds (between 0 and 999 seconds). The Alarm Delay value defines how long a threshold value must be exceeded before the corresponding warning or alarm is issued. Example of a temperature sensor: If the alarm delay is set to 20 seconds and the threshold for a warning is set to 50 C, an increase in temperature to 55 C will only result in a warning being issued if this excess temperature is measured for at least 20 seconds. If the measurement falls back below 50 C after 60 seconds, for example, no warning will be issued, despite the fact that the temperature was for a time above the defined threshold value. Note! It is not possible to enter Alarm Delay values for ActivePSM busbars/modules.