Beck. The differential pressure transmitter for air

Similar documents
Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Analog Room Pressure Monitor RPC Series

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

Differential pressure sensors

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

DP86 Constant Voltage with Fitting

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

86BSD Digital Output

CLEANROOM MONITOR CR3A Network - Installation Instructions

Gas cylinder scale Model GCS-1

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

86BSD Digital Output

Dräger Polytron 8700 IR Detection of flammable gases and vapors

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Dräger Polytron 8310 IR Detection of flammable gases and vapour

HVAC Sensors Catalogue

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Standard SPECIFICATIONS FEATURES APPLICATIONS

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Force Sensors Line Guide

Sub psi SPECIFICATIONS

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Oxygen (O2) Single-Point Gas Detection System

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

P125 High Pressure Sensor

Dräger Polytron 8700 IR Detection of flammable gases and vapors

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

89BSD Digital Output

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

86BSD Digital Output

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

SCHMIDT LED Measured Value Display MD Instructions for Use

MS4525 SPECIFICATIONS

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Dräger Polytron 8720 IR Detection of carbon dioxide

Dissolved Oxygen Measurement liquisys M COM 223 / 253

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

Measurement Solutions for Refrigeration Technology.

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

Hygro/hygrothermal transducers (hygrometric)

Selecting Honeywell Board Mount Pressure Sensors

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Ultrasonic Proximity Sensor

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Dräger Polytron 5720 IR Toxic Gas Detection

Automatic Isokinetic Sampler ST5

Dräger Polytron 5720 IR Detection of carbon dioxide

D5100 Industrial Differential Pressure Transducer

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

CMT MANUAL 6. NMC SENSORS

FAST RESPONSE TEMPERATURE SENSORS 42.11a

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Product data sheet AIRWIN BO-FK-120J Humidity sensors

Hygro/hygrothermal transducers (hygrometric)

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Model D12-IR. Digital Gas Transmitter...

I/A Series 716C 1/16 DIN Temperature Controller

Accuracy by Design Products for the HVAC Professional

M7100 Pressure Transducer

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

U5700 Submersible Liquid Level Pressure Transducer

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Board Mount Pressure Sensors Line Guide

PolyGard 2-channel Gas Controller MGC-03

Datasheet: K-22 LO Sensor

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Measurement Solutions for Refrigeration Technology.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Installation Manual Tracker 221

Transcription:

Beck. The differential pressure transmitter for air

Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure, overpressure and vacuum. They provide up to 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch. Applications Monitoring of gaseous, non-combustible and non-aggressive media. Possible usage areas are: Building automation and air conditioning systems Overpressure measurement in clean rooms and laboratories Measurement of constant pressure in VAV applications Dynamic filter and ventilator monitoring Configurable pressure range For an optimum adaptation to the application, the transmitter can be switched between various pressure ranges. The factory setting is the most sensitive range. For the series 984M and 984A the less sensitive second range will be selected by simply removing a jumper. For the series 984Q the available eight ranges can be selected by a rotary selector switch. Volume flow measurement (optional) The shape of the output signal can be switched from linear to square root using a jumper in order to measure the volume flow via a differential pressure. Switching output (optional, not available with 2-wire version) To give a switch signal at an user defined pressure level the transmitter has an adjustable transistor switching output (npn NO) with a maximum switching capacity of 30 Vdc/100 ma. Display (optional, not available with 2-wire version) In addition to the analogue output signal the pressure value can be read out on a red LED-display in Pascal or other pressure units. Measuring method Piezoresistive pressure transducer Mounting position Can be mounted in any position. The zero offset calibration eliminates any possible position error. Output signal selection The output signal of the 3-wire version can be changed between 0...10 Volt and 4... 20 ma by removing a jumper. The series 984M is also available in a 2-wire version with 4... 20 ma output signal. Configurable response time The response time of the output signal can be configured using a jumper. If the jumper is in place the response time is slow (factory setting), which is useful for suppressing brief pressure peaks. If the application requires a fast response time the jumper must be removed. Easy offset calibration The output signal of the 984M series can be calibrated to zero by pressing the M push-bottun in a pressureless state of the transmitter. The series 984A and 984Q perform an automated zero offset compensation.

Overview on technical data Series 984M 984M 984A 984Q Electrical connection 2-wire 3-wire 3-wire 3-wire Measuring method Supply voltage 18...30 VDC Piezoresistive pressure transducer 18...30 VAC / VDC 18 30 VAC / VDC 18 30 VAC / VDC Output signal selectable with jumper with jumper with jumper Output signal 0... 10 V Output signal 4... 20 ma Output signal 0... 5 V Output signal 0... 20 ma LED display, red, 4 digits Switching output for max 30 VDC / 100 ma Output signal selection from linear to square root Max. current draw without display VDC / VAC 21 / ma 50 / 140 ma 60 / 150 ma 60 / 150 ma Max. current draw with display VDC / VAC / 70 / 180 ma 80 / 190 ma 80 / 190 ma Load for 4... 20 ma output 20... 500 Ω Load for 0... 10 V output 1kΩ ( 10mA) 1kΩ ( 10mA) 1kΩ ( 10mA) Pressure medium Air, non-combustible and non-aggressive gases Configuration of pressure range with jumper with jumper with jumper with rotary switch Max. number of pressure range 2 2 2 8 Only one customized pressure range Manuel offset compensation Automated offset compensation Working temperature Storage temperature 0 +50 C -10 +70 C Linearity (incl. hysteresis and repeatability) Uncertainty (Total Error Band w/o long-term and temperature effects) ±0.5% FS, min. ±1 Pa ±1% FS, min. ±1 Pa Long-term stability ±1% FS ±1% FS n.r. n.r. Long-term stability with automatic zero-point adjustment Humidity n.r. 0... 95% rel, non-condensing Response time 0.1 s and 1 s (standard) Response time free selectable between 0.1 s and 20 s Process connection P1 and P2 Electrical connection Housing material Mounting Housing dimensions Hose connection with 6 mm outer diameter Screw terminal block for wires and strands up to 1.5 mm² Housing with process connection P2 ( ) made from ABS Base part with process connection P1 (+) made from POM Screw mounting with serrated screws Approx. Ø 85 x 58 mm Weight Approx. 120 gr Approx. 135 gr Approx. 150 gr Approx. 150 gr Protection class acc. to EN 60529 IP54 with protection cap or IP00 without protection cap CE Conformance acc. to EN 61326 RoHS Conformance acc. to 2011/65/EU Accuracy specifications according to EN 60770 based on the pressure measurement at 23 C standard equipment optional equipment

Differential pressure transmitter 984M with manual offset compensation and 2 pressure ranges Pressure ranges Model Range 1 Range 2 Overload capacity Bursting pressure 984M.3X3-50... 0... +50 Pa - 60 kpa 100 kpa ± 0.8 984M.3W3-100... 0... +100 Pa - 60 kpa 100 kpa ± 0.7 984M.323 0... 100 Pa 0... 250 Pa 60 kpa 100 kpa ± 0.7 984M.333 0... 250 Pa 0... 500 Pa 60 kpa 100 kpa ± 0.5 984M.343 0... 500 Pa 0... 1000 Pa 75 kpa 125 kpa ± 0.3 984M.353 0... 1 kpa 0... 2.5 kpa 85 kpa 135 kpa ± 0.3 984M.373 0... 5 kpa 0... 10 kpa 85 kpa 135 kpa ± 0.3 984M.393 0... 25 kpa 0... 50 kpa 200 kpa 400 kpa ± 0.3 984M.3A3 0... 50 kpa 0... 100 kpa 200 kpa 400 kpa ± 0.3 Further pressure ranges on request. Additional uncertainty with temperature [% FS/10K] Order matrix IP protection class IP 54 with cable conduit M20x1.5 IP 54 with cap nut conduit AF20 984M.3 5 Configurable pressure - 50... 0... +50 Pa (-0.5... 0... +0.5 mbar) X range - 100... 0... +100 Pa (-1.0... 0... +1.0 mbar) W 0... 100 Pa (1.0 mbar) 0... 250 Pa (2.5 mbar) 2 0... 250 Pa (2.5 mbar) 0... 500 Pa (5.0 mbar) 3 0... 500 Pa (5.0 mbar) 0... 1000 Pa (10 mbar) 4 0... 1 kpa (10 mbar) 0... 2,5 kpa (25 mbar) 5 0... 5 kpa (50 mbar) 0... 10 kpa (100 mbar) 7 0... 25 kpa (250 mbar) 0... 50 kpa (500 mbar) 9 0... 50 kpa (500 mbar) 0... 100 kpa (1.0 bar) A Pressure unit mbar 1 Pascal 3 Output signal and supply voltage 0... 10 V or 4... 20 ma, 3-wire, 24 VAC / VDC, with switching output 1 0... 10 V or 4... 20 ma, 3-wire, 24 VAC / VDC, without switching output 7 4... 20 ma or 0... 10 V, 3-wire, 24 VAC / VDC, with switching output 3 4... 20 ma or 0... 10 V, 3-wire, 24 VAC / VDC, without switching output D 4... 20 ma, 2-wire, 24 VDC 2 Display no display 0 with LED-display, 4 digits (only for 3-wire) 1 Electrical connection via screw terminal block 4b Factory settings printed in bold type. Terminal assignments 3-wire with switching output Screw terminal block, 4-pole 1 2 3 4 4 Switching output (SO) 3-wire without switching output 4 Not used 2-wire 2 Output signal (4 20 ma) 1 Supply voltage (18...30 VDC)

Differential pressure transmitter 984A with automated offset compensation and 2 pressure ranges Pressure ranges Model Range 1 Range 2 Overload capacity Bursting pressure 984A.3E3-25... 0... +25 Pa - 60 kpa 100 kpa ± 0.5 984A.3X3-50... 0... +50 Pa - 60 kpa 100 kpa ± 0.3 984A.3W3-100... 0... +100 Pa - 60 kpa 100 kpa ± 0.2 984A.303 0... 25 Pa 0... 50 Pa 60 kpa 100 kpa ± 0.5 984A.313 0... 50 Pa 0... 100 Pa 60 kpa 100 kpa ± 0.3 984A.323 0... 100 Pa 0... 250 Pa 60 kpa 100 kpa ± 0.2 984A.333 0... 250 Pa 0... 500 Pa 60 kpa 100 kpa n.r. 984A.343 0... 500 Pa 0... 1000 Pa 75 kpa 125 kpa n.r. 984A.353 0... 1 kpa 0... 2.5 kpa 85 kpa 135 kpa n.r. 984A.373 0... 5 kpa 0... 10 kpa 85 kpa 135 kpa n.r. 984A.393 0... 25 kpa 0... 50 kpa 200 kpa 400 kpa n.r. Further pressure ranges on request. Additional uncertainty with temperature [% FS/10K] Order matrix IP protection class IP 54 with cable conduit M20x1.5 IP 54 with cap nut conduit AF20 984A.3 5 Configurable pressure - 25... 0... +25 Pa (-0.25... 0... +0.25 mbar) E range - 50... 0... +50 Pa (-0.5... 0... +0.5 mbar) X - 100... 0... +100 Pa (-1.0... 0... +1.0 mbar) W 0... 25 Pa (0.25 mbar) 0... 50 Pa (0.5 mbar) 0 0... 50 Pa (0.5 mbar) 0... 100 Pa (1.0 mbar) 1 0... 100 Pa (1.0 mbar) 0... 250 Pa (2.5 mbar) 2 0... 250 Pa (2.5 mbar) 0... 500 Pa (5.0 mbar) 3 0... 500 Pa (5.0 mbar) 0...1000 Pa (10 mbar) 4 0... 1 kpa (10 mbar) 0... 2,5 kpa (25 mbar) 5 0... 5 kpa (50 mbar) 0... 10 kpa (100 mbar) 7 0... 25 kpa (250 mbar) 0... 50 kpa (500 mbar) 9 Pressure unit mbar 1 Pascal 3 Output signal and supply voltage 0... 10 V or 4... 20 ma, 3-wire, 24 VAC / VDC, with switching output 1 0... 10 V or 4... 20 ma, 3-wire, 24 VAC / VDC, without switching output 7 4... 20 ma or 0... 10 V, 3-wire, 24 VAC / VDC, with switching output 3 4... 20 ma or 0... 10 V, 3-wire, 24 VAC / VDC, without switching output D Display no display 0 with LED-display, 4 digits (only for 3-wire) 1 Electrical connection via screw terminal block 4b Factory settings printed in bold type. Terminal assignments 3-wire with switching output Screw terminal block, 4-pole 1 2 3 4 4 Switching output (SO) 3-wire without switching output 4 Not used

Differential pressure transmitter 984Q with automated offset compensation and 8 pressure ranges Pressure ranges Model Position Pressure range Overload capacity Bursting pressure 984Q.x43 1 0... 100 Pa 75 kpa 125 kpa ± 1.0 2 0... 250 Pa 75 kpa 125 kpa ± 0.3 3 0... 500 Pa 75 kpa 125 kpa n.r. 4 0... 1000 Pa 75 kpa 125 kpa n.r. 5-50... 0... +50 Pa 75 kpa 125 kpa ± 1.0 6-100... 0... +100 Pa 75 kpa 125 kpa ± 0.7 7-250... 0... +250 Pa 75 kpa 125 kpa n.r. 8-500... 0... +500 Pa 75 kpa 125 kpa n.r. 0 fixed output signal 0 V / 4 ma - - - 9 fixed output signal 10 V / 20 ma - - - 984Q.x53 1-100... 0... +100 Pa 85 kpa 135 kpa ± 1.0 2 0... 100 Pa 85 kpa 135 kpa ± 1.3 3 0... 200 Pa 85 kpa 135 kpa ± 1.0 4 0... 500 Pa 85 kpa 135 kpa ± 0.5 5 0... 1000 Pa 85 kpa 135 kpa ± 0.2 6 0... 1500 Pa 85 kpa 135 kpa n.r. 7 0... 2000 Pa 85 kpa 135 kpa n.r. 8 0... 2500 Pa 85 kpa 135 kpa n.r. 0 fixed output signal 0 V / 4 ma - - - 9 fixed output signal 10 V / 20 ma - - - Further pressure ranges on request. Additional uncertainty with temperature [% FS/10K] Order matrix IP protection class IP 54 with cable conduit M20x1.5 IP 54 with cap nut conduit AF20 984Q.3 5 Configurable pressure see pressure ranges range max. 1000 Pa (10 mbar) 4 max. 2500 Pa (25 mbar) 5 Pressure unit mbar 1 Output signal and supply voltage Pascal 3 0... 10 V or 4... 20 ma, 3-wire, 24 VAC / VDC, with switching output 1 0... 10 V or 4... 20 ma, 3-wire, 24 VAC / VDC, without switching output 7 4... 20 ma or 0... 10 V, 3-wire, 24 VAC / VDC, with switching output 3 4... 20 ma or 0... 10 V, 3-wire, 24 VAC / VDC, without switching output D Display no display 0 with LED-display, 4 digits (only for 3-wire) 1 Electrical connection via screw terminal block 4b Factory settings printed in bold type. Terminal assignments 3-wire with switching output Screw terminal block, 4-pole 1 2 3 4 Rotary Switch 4 Switching output (SO) 3-wire without switching output 4 Not used

Dimensional Drawings 984 with cap nut conduit AF20 Mounting bracket 6481 Mounting bracket 6482 Duct connection for Duct connection for Mounting bracket Mounting bracket Climaset 6550/6556 Climaset 6555/6557 6401 6402

Analog output signal Linear (Jumper 3 inserted) Square root (Jumper 3 opened) 0 10 V 0 10 V 4 20 ma 4 20 ma 984_data_english 02/2018 Technical data subject to change without prior notice. Copyright 2018 Beck GmbH Accessories Metal mounting bracket S-shaped Article No. 6402 Metal mounting bracket L-shaped Article No. 6401 Snap-on plastic bracket S-shaped Article No. 6482 Snap-on plastic bracket L-spaped Article No. 6481 Climaset consisting of 2m PVC hose and 2 plastic pipes Article No. 6555 Climaset consisting of 2m Silicone hose and 2 plastic pipes Article No. 6557 Climaset consisting of 2m PVC hose and 2 angled metal pipes Article No. 6550 Climaset consisting of 2m Silicone hose and 2 angled metal pipes Article No. 6556 Duct connecting pipe for Climaset 6555 Article No. 6551 Angled metal pipe for Climaset 6550 Article No. 6552 Rubber grommet for Climaset 6550 Article No. 6553 Roll with 100 m PVC hose Article No. 6424 Roll with 100 m Silicone hose Article No. 6425 Cap nut conduit AF20 with integrated cable strain relief Article No. 6562 M20x1.5 cable conduit including sealing and counter screw Article No. 6568 Folding box for individual packing (with accessories) Article No. 6428 Folding box for individual packing (with accessories) Article No. 6429