Manual for QX0201 Push Button

Explosion-proof Immersion Heater Type D-8660

manual addendum DELPHI Ex

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Manual Power relay SR853

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Operating Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Flameproof Manual Call Points Series MCP

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Certificate of Conformity

Certificate of Compliance

Certificate of Compliance

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Certificate of Compliance

TYPE APPROVAL CERTIFICATE

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Fan Heaters Type VLEx

Flameproof Manual Call Points

ExPolar Heating System

High bay LED lighting fixture

Flameproof Manual Call Points Series MCP

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL (ATEX / IECEx)

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

XLFE-4/1. Borosilicate glass globe

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

LICO HDL3 & HDL5, certified EN54-5-Heat- & Fire-Detectors

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

805QS Pressure Switch-Transmitter

Limit Switch Box YT-870/875 SERIES

Explosion Proof Manual Call Points Series MCP

IECEx Certificate of Conformity

INSTRUCTION & SERVICE MANUAL

OPTIBAR DP 7060 Supplementary Instructions

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Explosion Proof Combination Signal db (A) / 5 Joule

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

OPTIWAVE X500 Supplementary Instructions

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Operating Manual Distribution box

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Easy installation Certified for zones 1 and 21 High IP degree of protection

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Main switch current K: with main switch (optional)

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

BKA-EN Fire Damper. Additional operating instructions according to

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Illumination unit For sight glass level indicator Model LGI

IECEx Certificate of Conformity

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

ATEX Enclosures. Safety in an explosive atmosphere

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Quick Start Guide For the

ATM Lighting sp. z o.o

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

BSK-RPR Fire Damper. Additional operating instructions according to

Inductive slot sensor

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Translation of the assembly instructions with operating instructions and technical appendix

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

HR Powder Feed Hopper

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Ex LED light fittings

Certification Supplement Manual

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

IECEx Certificate of Conformity

Approved by: Document no.: EGT

The sealless FLUX F 424

Sinus Jevi (Explosion-Proof) Condens Heaters

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Technical Information OUSTF10

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

ATM Lighting sp. z o.o

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Supplementary Installation and Operating Instructions. Category II2G

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Transcription:

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl

Purpose of these instructions - Working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. - Assembly and maintenance staff working on installations therefore have a particular responsibility. They require precise knowledge of the applicable standards and regulations. - These instructions give a brief summary of the most important safety measures. It supplements the corresponding regulations which the staff must study. SAFETY INSTRUCTIONS - Use the explosion-proof cable gland only for its intended purpose. - Explosion-proof cable glands are not suitable for Zone 0 hazardous areas! - Incorrect or impermissible use or non-compliance with these instructions invalidates our warranty provision. - No changes to the device impairing its explosion protection are permitted. - Use the explosion-proof cable gland only if they are clean and undamaged. - Any damage can invalidate the Ex-protection. - Observe the following during installation and operation: - National safety regulations; - National accident prevention regulations; - National installation regulations (e.g. IEC 60079-14); - Generally recognized technical regulations; - Safety guidelines in these operating instructions; Conformity to standards The explosion-proof cable gland is designed and manufactured according to standard of ISO 9001. The explosion-proof cable glands is conformity to the directive 94/9/EC, ATEX and the following standards: EN 60079-0 : 2009 EN60079-1 : 2007 EN 60079-7 : 2007 EN60079-31 : 2008 Applicable scope The series product can be used in zone 1, 2, 21 and zone 22. -1-

Technical data Ex mark: I/II 2G / Ex d I/IIC Gb I/II 2G / Ex e I/IIC Gb III 2D / Ex tb IIIC Db IP66 Test certificate ISSeP 10 ATEX 035U Reduced marking - Locknuts, shrouds and earth tags are only marked with Ex Ambient temparature - With EPDM o-rings and shrouds or Nylon gaskets -40 C to 100 C, with Silicone materials -70 C to 220 C Accessories / Spare parts Use only original spare parts as well as original accessories produceed by INDEX ELEKTRO BV. Maintenance / repairs - Observe the relevant national regulations for your country. - Only parts from our company that can be used to replace or maintenance and the operation should be carried out by professional staf. - The following points must be checked during maintenance: * Compliance with permitted temperatures of the enclosures * Check if the product has been fixed reliably. * Check if the product is damaged. Disposal / recycling The respective valid national regulations for waste disposal shall be observed when disposing products. We are pleased to answer any questions. In this case you can contact INDEX ELEKTRO BV. -2-

Model and implication Explosion-proof Reducers / Adapters / Couplings / Wiring nipples I x B = Brass / N = Nickel Plated / S = Stainless Steel 316 1. 2. Female thread Male thread Type of product AD RED NIPP KOP W 1. 2. = Adapter = Reducer = Nipple = Coupling = Wiring nipple Productcode of Index Elektro BV Explosion-proof Plugs / Locknuts / Shrouds / Earth tags / Wiring nipples I B = Brass / N = Nickel Plated / S = Stainless Steel 316 Male thread Type of product 1. 2. PLUG E33 EART HR GAS W = Plug = Locknut = Earthing tag = Schroud = Gasket = Wiring nipple Productcode of Index Elektro BV -3-

Operation/installation - Transport and storage in original packaging only. National safety and installations regulations and the generally accepted rules of engineering practice must be observed when mounting and using this equipment. - Explosion-proof cable gland is suitable for use in hazardous areas, zones 1, 2, 21 and 22. - The choice, application and mounting of the products must be at all times in accordance with the EN IEC 60079 part 14 Mounting equipment 1. Screw the products for Ex d or Ex e applications into the box or device For Ex d applications at least 5 windings 2. Equipment for Ex e applications may be mounted with a locknut -4-