UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

MODEL: FA007C FA008C STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD WRENCH FLAT

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Numbers

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Sprinkler Identification Numbers

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Submittal Packages Detailed with Items and Reviewers

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model/Sprinkler Identification Numbers

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Sprinkler Identification Number (SIN)

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

DISCONTINUED PRODUCT

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

TECHNICAL DATA vk470 (K3.0)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

STANDARD/quick. Sprinkler 42o. August 8, 2011

freedom residential pendent sprinkler vk466 (K5.2)

Norminal Sprinkler Temperature Rating

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

microfast sr/qr extended coverage pendent sprinkler

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

The Series LFII (TY3596) Residential

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

Transcription:

UPRIGHT SPRINKLERS AND PENDENT SPRINKLERS MODEL: BZ003 / BZ004 / BZ005 / BZ006 STANDARD SPRAY, STANDARD / QUICK RESPONSE, 5 / 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD GENERAL DESCRIPTION The BZ003/BZ004 Standard/Quick Response Upright and BZ005/BZ006 Standard/Quick Response Pendent Sprinklers (Ref. Figure A) are automatic sprinklers of the frangible bulb type. They are standard/quick response standard orifice spray sprinkler intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The Upright, Pendent Sprinklers all produce a hemispherical water distribution pattern below the deflector. SPRINKLER OPERATION During a fire conditions, the thermal-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the button and spring seal assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA13 standards. FIGURE A : MODEL BZ003/BZ004 UPRIGHT & MODEL BZ005/BZ006 PENDENT SPRINKLERS

TECHNICAL SPECIFICATIONS Model & Sprinkler I.D. No. BZ003 BZ004 BZ005 BZ006 Style Upright Pendent Bulb Nominal Dia. & Response Ø5mm, Standard Ø3mm, Quick Ø5mm, Standard Ø3mm, Quick Response Response Response Response Thread Size [Optional] NPT1/2 or R1 2 Nominal Orifice Size 1/2 Inch Nominal K-Factor 5.6 (U.S.) 80 (metric) Max. Working Pressure 175 psig 1.2 MPa (12 bar) Factory Hydrostatic Test 100% @ 500psig (3.4 MPa) Min. Operating Pressure 7 psig 0.048 MPa (0.48 bar) Sprinkler Finish [Optional] Natural Brass or Chrome Plated Escutcheon Finish Chrome Plated or Color Coated In Any Color Listings and Approvals UL(United States) ULC(Canada) AVAILABLE TEMPERATURE RATING Temp. Classification Ordinary Ordinary Intermediate Intermediate Nominal Temp. Rating 135 F 57 C 155 F 68 C 175 F 79 C 200 F 93 C Max. Ambient Temp. Allowed 5 115 F 46 C 135 F 57 C 155 F 68 C 180 F 82 C Max. Recommended Ambient Temp. 6 100 F 38 C 100 F 38 C 150 F 65 C 150 F 65 C Glass Bulb Color 7 Orange Red Yellow Green Footnotes: 1 Sprinkler I.D. Nos. and nominal U.S. K-factors provided in accordance with the 2002 edition of NFPA 13. 2 The pipe thread connections accord with ISO7/1. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 UL and ULC Listed for both Light-Hazard and Ordinary-Hazard occupancies. 5 Based on National Fire Prevention and Control Administration Contract No. 7-34860. 6 Based on NFPA 13. Other limits may apply depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 7 The temperature rating is stamped on the deflector or adjacent to orifice seat on frame. SPRINKLER MATERIALS Frame Deflector Glass Bulb Set Screw Button Spring Seal Standard Escutcheon (Type E-1) Bronze Forging UNS-C87400 or Casting DZR Brass UNS-28000 Glass with Glycerin Solution, JOB G5 or Day-Impex-937 for BZ003/ BZ005 JOB F3 0r Day-Impex-941 for BZ004/ BZ006 Brass UNS-28000 Brass UNS-28000 Stainless Steel Teflon Tape Cold Rolled Steel ACCESSORIES Standard Escutcheon Type E-1 Installation Wrench Type T-1 DISCHARGE COEFFICIENT Model BZ003/BZ004 Upright and Model BZ005/BZ006 Pendent Sprinklers are rated for use at a maximum service pressure of 175 psig (12 bar). The nominal discharge curve plotted in Figure B represents the flow Q in GPM (LPM) as determined by the following formula: Q=K(P) 0.5

Where: DISCHARGE IN U.S. GALLONS PER MINUTE (GPM) 70 65 60 55 50 45 40 35 30 25 20 15 10 5 PRESSURE IN POUNDS PER SQUARE INCH (PSIG) 10 30 50 70 90 110 130 150 170 280 PARTIAL CURVE ONLY MAX. PRESSURE 175 PSIG 260 240 ü NOMINAL K=5.6 ý NOMINAL K=80 PARTIAL CURVE ONLY MAX. PRESSURE 1.2 MPA 220 200 180 160 140 120 100 80 60 40 20 DISCHARGE IN LITERS PER MINUTE (LPM) 0 0.2 0.4 0.6 0.8 1.0 1.2 PRESSURE IN MPA FIGURE B : NOMINAL DISCHARGE CURVE Q Flow, GPM (LPM) K Discharge Coefficient, K=5.6 (80) P Discharge Pressure, psig (bar) Listing standards permit the actual value of K to vary from 5.3 to 5.8 (76,4 to 83,6); however, for hydraulic calculations, a K-factor of 5.6 (80,7) is to be applied.

WARNING The Model BZ003/BZ004 Upright Sprinklers and Model BZ005/BZ006 Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. sprinkler inlet with consequent leakage or impairment of the sprinkler. INSTALLATION NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontal, a small air bubble should be present. FIGURE C : MODEL BZ005/BZ006 PENDENT SPRINKLER INSTALLED WITH A STANDARD ESCUTCHEON The Model BZ003/BZ004 Upright Sprinklers and Model BZ005/BZ006 Pendent Sprinklers must be installed in accordance with the following instructions. 1. Prior to installing the sprinklers, if applicable, verify that the face of the sprinkler fitting is within the proper range of distance, which can be accommodated by the type of escutcheon being used. 2. With pipe thread sealant applied to the pipe threads and after installing standard escutcheon, over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. 3. Refer to Figure D and select the appropriate Sprinkler Wrench for tightening the sprinkler into the sprinkler fitting. NOTES A leak tight 1/2 pipe thread sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9.5 to 19.0 Nm). A maximum of 21 ft.lbs. (28.5 Nm) of torque is to be used to install the sprinkler. Higher levels of torque may distort the FIGURE D: SPRINKLER WRENCH SELECTION & USE Push on the Sprinkler Wrench, while it is being turned, to ensure that the Wrench recess stays fully engaged with the sprinkler wrench flats. Carefully remove the Sprinkler Wrench by disengaging it from the sprinkler wrench flats, and then lowering it down over the sprinkler deflector. CARE AND MAINTENANCE Automatic sprinklers must never be shipped or stored where their temperatures will exceed

100 F/38 C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers both before and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage or the like, and must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). NOTES Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection system control valve for maintenance work on the fire protection system, which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. It is recommended that automatic sprinkler systems be inspected quarterly by a qualified Inspection Service. ORDERING PROCEDURE A Product Symbol Number (PSN) shall be specified when ordering sprinklers. And it is suggested that a color chip be provided when ordering special color coated Escutcheons. Otherwise, responsibility for duplication cannot be accepted. Contact your local distributor for availability. Sprinkler Assemblies: Specify: 1/2" orifice, (specify temperature rating), Model BZ003/BZ004 Upright Sprinklers with (specify type of finish), PSN (specify as follows). BZ003/BZ004 Standard/Quick Response Upright Sprinklers : PSN 012 X 1 13 X 2 X 3 X 1 Response Frame 1 Standard Response UNS-C87400 2 Quick Response,UNS-C87400 3 Standard Response DZR 4 Quick Response DZR X 2 Class Bulb and Nominal Temperature Rating 1 Job,135 F 57 C 2 Job,155 F 68 C 3 Job,175 F 79 C 4 Job,200 F 93 C 5 Day-Impex,135 F 57 C 6 Day-Impex,155 F 68 C 7 Day-Impex,175 F 79 C 8 Day-Impex,200 F 93 C X 3 Thread Size and Sprinkler Finish 1 NPT1/2 Natural Brass 2 NPT1/2 Chrome Plated 3 R1 2 per ISO 7/1 Natural Brass 4 R1 2 per ISO 7/1 Chrome Plated BZ005/BZ006 Standard/Quick Response Pendent Sprinklers : PSN 012 X 1 23 X 2 X 3 X 1 Response and Frame 1 Standard Response UNS-C87400 2 Quick Response,UNS-C87400 3 Standard Response DZR 4 Quick Response DZR X 2 Class Bulb and Nominal Temperature Rating 1 Job,135 F 57 C 2 Job,155 F 68 C 3 Job, 175 F 79 C 4 Job, 200 F 93 C 5 Day-Impex, 135 F 57 C 6 Day-Impex, 155 F 68 C 7 Day-Impex, 75 F 79 C 8 Day-Impex, 200 F 93 C X 3 Thread Size and Sprinkler Finish 1 NPT1/2 Natural Brass 2 NPT1/2 Chrome Plated 3 R1 2 per ISO 7/1 Natural Brass 4 R1 2 per ISO 7/1 Chrome Plated Accessories: Order the following accessories, as applicable:

Type E-1 1/2" Standard Escutcheon with chromate finishes: PSN 0608 111 Type E-1 1/2" Standard Escutcheon with white painted finish: PSN 0608 112 Type T-1 Wrench: PSN0109 WEIGHT The nominal weights are as follows. 1/2" Orifice Model BZ003/ BZ004 Upright 2.8 ozs. (80 g) 1/2" Orifice Model BZ005/ BZ006 Pendent 2.8 ozs. (80 g) E-1 Standard Escutcheon 0.6 ozs. (18 g) T-1 Sprinkler Wrench 18 ozs. (510 g) CONVERSION TABLE Name of Unit Unit Conversion Symbol Factor Millimeter mm 1 in.=25.4 mm Square meter m 2 1 ft 2 =0.0929 m 2 Liter L 1 gal=3.785 L Cubic decimeter dm 3 1 gal=3.785 dm 3 Cubic meter m 3 1 ft 3 =0.0283 m 3 Kilogram kg 1 lb=16 ozs.=0.4536 kg Kilograms per cubic meter Kg/m 3 1 lb/ft 3 =16.0183kg/m 3 Pascal Pa 1 psi=6895 Pa Bar bar 1 psi=0.0689 bar Newton meter N m 1 ft lbs=1.355 N m! WARNING

This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. We reserve the right to change product specifications, designs and standard equipment without notice and without incurring obligations. If you have any questions about the safe installation and use of this device, contact Ponmani International India Private Limited., No.33, Jeenis Raod, Saidapet, Chennai 600 033. INDIA