SMP 19160, SMP 29160

Similar documents
TARN 1370, TARN No /00 E. Cold Storage Controller. Technical Manual. Software Version

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

User manual. KNXgal. version

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

UV - Monitor UVT 16. Use. Description

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

D-TECT 3 IP. GJD260 IP Motion Detector

User Manual. Dryer Controller M720

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

DOCUMENTATION IPS640

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

HRX Technical Manual. Version 1.2

GLOBAL. InstallatIon & operation manual

P2267 NETWORK INTERFACE

ME 3011C / Alarm Indication / Quick Reference Guide

Danfoss gas detection units

Dryer Controller M720

OVEN INDUSTRIES, INC.

D-TECT 2 IP. GJD230 IP Motion Detector

Laptop / PC Programming Manual

CBI-064. User Manual. Caddx to KNX-BUS Interface

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

DOCUMENTATION IPS640

SCR100 User Manual. Version:1.1 Date:Dec 2009

Multi-Gas-Controller MGC2

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

RAEGuard 2 PID. User Guide

Configuration and Operation Manual for the Unipos

PBI Manual. Paradox to KNX-BUS Interface

QIAcube HT Unpacking and Installation Instructions

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

Annunciator Unit SACO 16 D1. Product Guide

Oxygen (O2) Single-Point Gas Detection System

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

INSTALLATION INSTRUCTIONS

CLEANROOM MONITOR CR3A Network - Installation Instructions

Pioneer-R16 Gas Monitor Operator s Manual

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

Remote alarm indicator and test combination MK2430

Operating instructions 2-channel code lock. Item No

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Alarm module for leak detection with webserver

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

ModBus DE-1 INSTALLATION AND USER MANUAL

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Panel Mounted Fault Annunciator Series

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Danfoss gas detection units

1.7. Insulation fault evaluators EDS460/490 EDS461/491

FIREYE YZ300 and YZ320 INTERLOCK ANNUNCIATOR For use with the Fireye BurnerLogix Control

Metasys Integrator Vilter Application

Two-Channel Gas Controller

Product Manual SZ1144

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

20 Light Remote Annunciator

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Operations Manual TS400. Test Station for G450/G460 Gas Detector

rvm4c Installation Guide Remote Video Module

REPEATER FS5200R INSTRUCTION MANUAL

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

Installation Manual Premier 412/816/832. Issue 10

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Annunciator unit. Application

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Operating Manual MS220DA

Universal fault annunciator for panel mounting

Parameterisable compact fault annunciator with permanent display

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010

compact office 24V compact office 24V Lux

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

ND4000 Manual Marine Hydraulics

WeatherLink for Alarm Output Addendum

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

FX FIRE DETECTION SYSTEM

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

MO n : 12JMC rév A

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Installing ProSeries 2005

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

PTE0705 Electric Fence Monitor

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Declaration of Conformity no. 56/2012

725B Configuration Software Manual

System Galaxy Quick Guide

Transcription:

ELEKTROISCHE REGELUGE GMBH Technical Manual Alarm Message Module D- Hockenheim Schwetzinger Str. 0 SMP 90, SMP 90 phone (+9) (0) 0 / 009-0 fax (+9) (0) 0 / 0099 o. 0-0/0 E Softw.Vers. 990 Brief Description The Alarm Message Module SMP-x90 is qualified for monitoring any alarm messages coming with a mains voltage signal. Machine states can be monitored, displayed and forwarded by potential free contacts or by a data interface. All states of the module can be read via data interface. The module comes with factory set characteristics (described below), but can be configurated by a PC-configuration software via interface. The module contains the following features: - Alarm Relay - Operating Relay - Data Interface LED's for Operation Ready and any alarm messages Available Types: SMP 90...0V, SMP 90...V Functional Description of the factory set characteristics Stand-by operation If all mains voltage signals (related to pin d) are available, the module signalizes state of readiness, the green LED is O and the operation relay and the alarm relay are activated. Capture an alarm message If a disturbance occurs (mains voltage at an input) the green LED goes OFF and the red LED of the corresponding input lights up, both relays will be de-activated without delay (see table next page). If the disturbance is removed, the operation relay will be activated again, but the state of the alarm relay and the display remains until the module will be reset. Technical Data Supply Voltage SMP 90... 0V / 0-0 Hz, max. VA SMP 90... V / 0 Hz, max. VA Ambient Temperature... 0...+0 C Message Inputs... 0V, ma max. Relay Outputs... 0A cos phi=, A ind. Interface... x RS Software-Protocol... E-Link, max. controller units Lenght of data wire... max. 000 m Display... LED, mm, color selectable by softw. Construction / Connection... 9 -module, TE, connector F By removing a jumper the characteristic can be changed. Jumper J open: The operation relay can be activated only if the disturbance is removed. Jumper J set: If the disturbance is removed, the operation relay will be activated automatically. Reset Occured disturbances remain stored. The alarm relay, the LEDdisplay and the internal buzzer can be reset first if the disturbance is removed. Reset process - Push key 'LT/RST' (LED test at the same time) or - connect mains voltage-signal to the external reset input (LED test at the same time) - via interface by a PC These functions can be changed by the PC-program "SMP_cfg" via the data interface.

page Technical Manual Alarm Module SMP 90 pin OK colour input time delay Priority o. (Rel =operation Rel =alarm) Factory Settings input red yell. green activ pas- 0...0 OFF Rel Rel Rel Op- Dissiv minutes + erat. play (Standard: z0 X X 0' X all LED's z X X 0' X unlabelled) z X X 0' X z X X 0' X z X X 0' X z0 X X 0' X z X X 0' X Your Settings z0 z z z z z0 z Alarm relay passive, no buzzer Operation time counter : Adress: passive + buzzer Operation time counter : Baudrate: Alarm relay aktive, no buzzer Operation time counter : Operation Relay AutoO: Alarmrelais aktive + buzzer Operation time counter : Jumper J: Factory settings: Alarm relay: passive, no buzzer, electronic counters: not assigned to an OK-input, Adress:, Baudrate 900, Operation relay AutoO: 0, Jumper J: set. Installation - Connect both - pins (for power supply / alarm messages) - Connect -pin (z ). - Unused alarm message inputs must be connected to mains voltage or must be disabled by software configuration. etworking of Alarm Message Modules All SMP-moduls can be networked together with other controller units by their built-in RS--interface and can be controlled by a host. Mostly this is a PC with a remote/recording software. Remote operation from the Message Unit SMZ is possible too. Because all modules are connected parallel on the data wire (party-line), a network adress must be assigned to each module, to ensure a specific data transfer. So it is possible to read and process data from selected modules. shielding Pay attention to polarity! cm max. (.0 inch) connections as short as possible!!

Technical Manual Alarm Module SMP 90 page Runup in a network The SMP-module itself offers no option to select a network adress. To set an adress, the MS-Windows-program "SMP_CFG"- must be used, which runs on your Laptop or PC. You can download SMP_CFG from our website - www.elreha.de. You will find it under "service / download", additionally it is a part of our Info-CD. Hardware-Conditions PC with integrated RS--interface or PC/Laptop with interfaceconverter SSC-0. Preparation Mount and wire all modules, test function. Connect data interface, start PC and the program "SMP_CFG". Take up connection PC -> SMP. Choose "Option / Interface". Select the interface at the PC where the module to configure resp. the interface converter is connected. Choose if an interface converter or an SMZalarm message module connects PC and SMP. Select adress. Choose "SMP / Assign Adress". Enter an adress which is not used till now. Click on "Programming" As a result the LED's of all SMP's in the network are flashing in groups of.. ow push the 'LT/RST'-key of the module which should get the new adress. ow flashing stops, the module has taken over the adress. The other modules are not affected.. After all modules stop flashing after 0 seconds, repeat this procedure for further modules from step (.). Configuration of the module by PC-Software The module will be delivered with the characteristics described above, but the great advantage of this module is that the behavior of inputs and outputs can be changed by the PC-program "SMP_CFG". The standard settings can be restored at any time. Preparation and hardware conditions like above. The Main Menu The program 'SMP_CFG' runs under MS-Windows 9/9. Configurations will be stored as files. While the software setup, the configuration-files of the most important SMP-types will be copied to your harddisk. Start program After the start of the program you get an empty form and you can begin to create a new configuration. Alternatively you can open an existing configuration by "File/Open". File ew... Empty form, create new configuration Open... Open existing configuration Save... Save configuration Save as... Save configuration with a new name Exit... Close, exit SMP_CFG SMP Programming... Transfer configuration to a SMP Read... Read data from a SMP Assign Adress... Select an adress for a SMP Change Baudrate... Change data transfer speed Option Interface... Choose PC-interface for the connection Language... Select smp_cfg- language Help Info... Software Version

page Technical Manual Alarm Module SMP 90 In this example we have loaded the standard-configuration of the SMP-90. A click on a LED shows a colour assortment. The selected colour lights up at the module later. This LED will be assigned to that OK-input or function. Unused inputs can be disabled. umber of switching processes and the operation hours of this input. Two electronic, software readable operation time counters can be assigned to this inputs. The power switch of the module. (click to change) Tabs for OK-inputs. Output/Priority which should forward the message. OFF: Input affects no message Relay +: If an alarm occurs, the operation relay will be de-activated immediately, the alarm relay will be de-activated first after the time delay. Relay : The operation relay switches after the time delay is run down. Relay : The alarm relay switches after the time delay is run down. Operation: Optical indicator only, relays does not switch. Display: Input active = alarm state : mains voltage Input passive = alarm state : 0V Optical indicator + failure message via PC-software. Relay does not switch, after the end of an alarm the LED must be reset. Time delay for this input. If a delay is selected and an alarm occurs, the LED flashes as long as the timer is running down. After that the LED's light permanently and the relay switches. The alarm relay will be switched that way:: (passive: de-activated when an alarm occurs, active: activated when an alarm occurs) - active, no buzzer - passive, no buzzer - active + buzzer - passive + buzzer After this time is run down, the operation relay will be reset automatically. Transfer configuration to the SMP "SMP/Programming" opens this dialog box. Enter the adress of the unit to configure and click "Start". ow the created or changed configuration will be transfered to the selected unit. Please save the configuration before by "File/Save As" and a matching name. Change data transfer speed: Depending on your application, it can be necessary to change the factory set data transfer speed. Open "SMP/Change Baudrate", choose adress of the unit and baudrate and click on "Change". Read a configuration from a SMP-unit: Read the actual configuration of a SMP-module with "SMP/ Read". Enter the adress of the unit to read before. Change Program Language Open "Option/Language" and select desired language. Restart the program. ow 'SMP_cfg' runs in the choosen language.

Technical Manual Alarm Module SMP 90 page Dimensions / Connection, (TE),, SMP-9" J J 9 LT/RST ELREHA interface PC pol. 0 OUT I RTS GD Jumper optional cabinet interface PC 9 pol. 0 9 RI RI GD z z0 z z z0 z 9 Ground 9 out in L RS RS TxD RxD RTS GD SMP 90 SMP 90 The connection is possible optional by the SUB-D connector or the screw terminals Data connection to a PC/Laptop with serial COM-interface (RS-). Here an interface converter SSC 0 is used. Wiring diagram show a connector equal to DI "F", rear view. The terminal numbers are used in ELREHA pre-wired subracks. d 0 0 0 LT/RST P Input ext. LT/RST Input Input Input Input Input Input operationrelay alarmrelay RS- L 0 0 0 z 9 0 Attention! Low Voltage

page Technical Manual Alarm Module SMP 90 EG-Statement of Conformity We state the following: When operated in accordance with the technical manual, the criteria have been met that are outlined in the guidelines of the council for alignment of statutory orders of the member states on electro-magnetic consistency ( 9//EWG ). This declaration is valid for those products covered by the technical manual which itself is part of the declaration. Following standards were consulted for the confirmity testing with regard to electromagnetic consistency : IEC 000--, IEC 000--, IEC 000--*, IEC 000--, IEC 000--, E 0 B, E 00, part and ; E 00, part and, E 00 part, E 00-/A part /A This statement is made from the manufacturer / importer by: ELREHA Elektronische Regelungen GmbH Klaus Birkner, Developement and Hockenheim and leader of the EMC-Laboratory (ame / Anschrift / name / adress) Hockenheim..999... Ort/city Datum/date Unterschrift/sign *The conformity with IEC 000-- is derived from the IEC 000-- and IEC 000-- test results. The correlation with IEC 000-- is based on test results which are located on site at the manufacturer. This manual, which is part of the product, has been set up with care and our best knowledge, but mistakes are still possible. If you have any problems, difficulties or questions please don't hesitate asking our technical support. Technical details can be changed without notice, especially the software. Please note that the described functions are only valid for units containing the software with the version-number shown on page of this manual. set-up:..0, tkd/jr checked:..0, ek/ha approved:..0, mv/sha