FDV BA- Lighting AS BA24-CL76-8WD

Similar documents
Technical Application Guide for UP-SHINE LED Downlight

Technical Application Guide for UP-SHINE LED Ceiling light

Technical Application Guide for UPSHINE LED Ceiling light

Technical Application LED Pendant Light LUZ-PL W-W

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Spotlight

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

Technical Application Guide for UP-SHINE LED Track Light

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S

LED Ceiling Light. Informations. Application notes. Application Areas PS-AL W(-D,-S) Indoor

Technical Application Guide for UP-SHINE LED Ceiling light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

Dimmable LED Retrofit Kit

Technical application guide

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Technical Application Guide for PHILIPS LED Lamps

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

TROFFER RETROFIT KIT (TRK)

Technical application guide

110 lm w STANDARD SERIES

LED ROUND MINI PANELS

Recessed and surface mounted LED downlight family

LED Panel Light E830J

Surelight. MR16 GU10 LED Bulbs

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

ENERGY EFFICIENT LED SOLUTIONS

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

IP65 Dimmable LED. Fire Rated, Low Profile Downlights VELA RANGE. Lighting

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

ClearAccent - Affordable recessed LED spot

LED Seamless VaporProof Fixture Installation Instruction

LED Edge-Lit Flat Panels

Corn Light. Applications. Key Features. General Usage. 5years

SUNIDEA CO.,LIMITED.

Liteharbor Lighting Technology Co., Ltd.

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

LED Lights & Parts. World of LED Lights. Product Catalogue 2017 Vol 2. STORE ADDRESS 3695 E 1st Ave, Vancouver, BC V5M 1C2

Philips Master LED MR16

Affordable and reliable energy saving LED Lighting Luminaires

Dublin airport - Dublin, Ireland

Dimmable LED Downlight SAA&C-TICK,CE&ROHS Pass

CoreLine Recessed Spot the clear choice for LED

CoreLine Recessed Spot the clear choice for LED

P5500 LED Architectural Downlighting

WARRANTY LED ECO PANEL.

The Inceptor Lighting Range is perfect for all types of installation...

LED Fire Rated Downlight

SL2989 Revo 26W Adjust LED Downlight RECESSED LED DOWNLIGHTS

Luna LED Downlights 1

littil = big difference 2018&19 PRODUCT CATALOGUE PART OF ECHO GROUP

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit

LED Outdoor Wall Light Series

LED Shoplight fixture

The Commercial LED Lighting Specialist

CoreLine Waterproof the clear choice for LED

HIGH LUMINOUS EFFICIENCY

Catalogue. Sales Contact: Andy LIU. Mob: E:

lumenalpha downlight Specification Sheet

LEDVANCE Downlight L DIM

LED SLIM DISKS PK613LED FIXED 3-LIGHT ROUND

Vaya Linear LP, White & Mono

CDL8 LED Architectural

Fortimo LED Line Gen2 Module

CoreLine Wall-mounted the clear choice for LED

LUXCOMFO TM LED Flood Light Datasheet

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

2018 NORTHERN LIGHTING PRODUCT CATALOGUE

Specifications. Dimension (mm) Color Temperature Warm White Natural White Day White Pure White

SL2832 LED Wedge Wall Light 7W ARCHITECTURAL LED WALL LIGHTS

ELLA ID. High CRI, High lm/w OptoDrive LED-module

LED Panels. We re excited to unveil our new LED Panels. These new LED panels are ideal for commercial use and fit into standard tile grid systems.

Reflector T2 and GU10 6,000 hours

IR UV. General Lighting indoor round. LED Lighting. Product description IP44. Compliances: Technical Data: Aura. Model No Wattage Nominal Voltage *(V)

LED Product Catalogue

Sylproof Superia LED G2

Urbanlite. We light your world IK08 IP

1. Key Features and Benefits

LED Tri-Proof. LED Tri-Proof. T: +44 (0) E:

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

Ledinaire Batten Simply great LED

OUTPUT RANGE: VIVID SERIES

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

SL2988 Scorpion 8x3W LED Downlight RECESSED LED DOWNLIGHTS

High Efficiency LED Panel Lights


Transcription:

FDV BA- Lighting AS BA24-CL76-8WD

Introduction BA- Lighting Mini downlight is specially designed for European market with standard cutout size of 8mm. 15 /24 /36 /6 beam angle provided, applicable for various lighting effect. Smart optical design with combination of COB LED and PC reflector, maximally reduces UGR down to 19 or even less. 25 degree flexible rotary head makes installation easier and better. Up to 7% energy saving compared to standard CFL Long lifetime of 5, hours Triac dim 15 /24 /36 /6 wide beam angle 82-88mm cutout CCT: 27K 3K 4K 5K No UV/IR light Environment friendly, without Mercury or any other hazardous substances 25 Application notes IP54 for indoor use only Professional electrician for installation only Switch off before installation Do not touch when in use Keep away from hot steam and corrosive gas Application Areas It is designed for general lighting applications in office, supermarket, shop, school, hotel, etc. It is also widely used for public areas, such as stairway, lobby, reception, corridors etc. Certificate

Product Information 55. Ø82. Ø95. Technical Specifications 52. Model Voltage Power Power Factor Driver data Sheet Lumen (±5%) Beam angle Driver data DIM Non dim Input rated Voltage AC23V AC23V Frequency 5Hz 5Hz Input Voltage AC2-24V AC2-24V Efficiency 75% 78% Total load Wattage 8W±.5W 8W±.5W Power Factor.9.85 Rated input current.5a.5a Full load output Voltage DC32-38V DC32-38V Rated output current 18mA 18mA Output current range 18mA±5% 18mA±5% Power tolerance ±5% ±5% Current output tolerance ±5% ±5% Dimming range 8%-1% CCT Lifespan CRI Dimmable Dimension BA-CL76-3-8W 23V 8W.85 52 15 /24 /36 /6 27K 5h 9 No Ø95*55mm cutout 82-88mm BA-CL76-3-8W 23V 8W.85 54 15 /24 /36 /6 3K 5h 9 No Ø95*55mm cutout 82-88mm BA-CL76-3-8W 23V 8W.85 565 15 /24 /36 /6 4K 5h 9 No Ø95*55mm cutout 82-88mm BA-CL76-3-8W 23V 8W.85 57 15 /24 /36 /6 5K 5h 9 No Ø95*55mm cutout 82-88mm BA-CL76-3-8W-D 23V 8W.9 52 15 /24 /36 /6 27K 5h 9 Yes Ø95*55mm cutout 82-88mm BA-CL76-3-8W-D 23V 8W.9 54 15 /24 /36 /6 3K 5h 9 Yes Ø95*55mm cutout 82-88mm BA-CL76-3-8W-D 23V 8W.9 565 15 /24 /36 /6 4K 5h 9 Yes Ø95*55mm cutout 82-88mm BA-CL76-3-8W-D 23V 8W.9 57 15 /24 /36 /6 5K 5h 9 Yes Ø95*55mm cutout 82-88mm Dimmer Triac dimmers Short circuit protection PASS PASS Over voltage protection PASS PASS Over temperature protection PASS PASS Withstand voltage AC375V AC375V Fixture Compatibility Rated Wattage Electrical Classification Ingress Protection Operating Temp Operating Humidity Storage Temp 8W Ⅱ IP54-2 o C~45 o C ~9% -2 o C~65 o C

Spectral Distribution 27K 3K.8 Max=1974 [1.=2] 3.36 SDCM F27K.8 Max=756 [1.=2] 3.2 SDCM F3K.7.7.6.6.5.4.3 x=.4577 y=.4133.5.4.3 x=.4371 y=.46.2.2.1.1. 38 5 6 7 8. 38 5 6 7 8 4K 5K.8 Max=7171 [1.=2] 2.12SDCM F4K.8 Max=7547 [1.=2] 3.88 SDCM F5K.7.7.6.6.5.4.3 x=.3841 y=.3816.5.4.3 x=.3511 y=.3588.2.2.1.1. 38 5 6 7 8. 38 5 6 7 8 Photometric Diagram 27K 3K -12-9 -/+18 12 9 15. 13.5 12. MH=1m C/18 C9/27 Flux out: 354. lm -12-9 -/+18 12 9 2 18 16 MH=1m C/18 C9/27 Flux out: 438.9 lm 3 1.5 4 14 6 9. 7.5 8 12 1 9 6. 12 8 12 4.5 16 6-3 15 3 3. 1.5-3 2 3 4 2 AVERAGE BEAM ANGLE(5%): 37.6 DEG -25-2 -15-1 -5 5 1 15 2 25 Height Eavg, Emax Angle: 37.58deg Diameter AVERAGE BEAM ANGLE(5%): 39.6 DEG -25-2 -15-1 -5 5 1 15 2 25 Height Eavg, Emax Angle: 39.6deg Diameter 4K 5K -/+18-12 12-9 9 17 34 51 68 85-3 3 AVERAGE BEAM ANGLE(5%): 39. DEG MH=1m 8.5 C/18 C9/27 7.65 6.8 5.95 5.1 4.25 3.4 2.55 1.7.85-25 -2-15 -1-5 5 1 15 2 25 Flux out: 355. lm 3.281ft 48.27, 75.56fc 3.38ft 1m 519.6, 813.3lx 92.61cm 6.562ft 12.7, 18.89fc 6.77ft 2m 129.9, 23.3lx 185.22cm 9.843ft 5.364, 8.395fc 9.115ft 3m 57.73, 9.37lx 277.82cm 13.12ft 3.17, 4.722fc 12.15ft 4m 32.48, 5.83lx 37.43cm 16.4ft 1.931, 3.22fc 15.19ft 5m 2.78, 32.53lx 463.4cm Height Eavg, Emax Angle: 39.69deg Diameter -/+18-12 12-9 9 18 36 54 72 9-3 3 AVERAGE BEAM ANGLE(5%): 39.5 DEG MH=1m 9. C/18 C9/27 8.1 7.2 6.3 5.4 4.5 3.6 2.7 1.8.9-25 -2-15 -1-5 5 1 15 2 25 Flux out: 478.8 lm Height Eavg, Emax Angle: 38.87deg Diameter

Polar Diagram Comparison -15 O -/+18 O 15 O -12 O 12 O -9 O 9 O -6 O 18 36 54 72 9 6 O -3 O 3 O O AVERAGE BEAM ANGLE (5%): 39.5 DEG C/18, 39.5 deg C3/21, 39.2 deg C6/24, 39.5 deg C9/27, 38.6 deg Driver lifetime & LED light decay rate Driver Lifetime LED Light Decay Rate 9 11%.4 Lifetime (hours) 8 7 6 5 4 3 2 1 65 o C 75 o C 85 o C 95 o C 15 o C Capacitor Tc ( o C) % Luminous Flux 15%.35 1%.3 95%.25 9%.2 85%.15 8% 75% FLUX.1.5 U'V' 7%. 1 2 3 4 5 6 7 8 9 1 LifeTime (hours) Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at 15 C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be 12 C The highest withstand temperature of LED junction temperature is 15 C 7 6 IC Temperature ( o C) 5 4 3 2 Capacitor MOS LED Fitting 1 Transformer Environmental temperature 14:34:57 14:46:53 14:58:53 15:1:53 15:22:53 15:34:53 15:46:53 15:58:53 16:1:53 Time 16:22:53 16:34:53 16:46:53 16:58:53 17:1:53 17:22:53 17:34:53 17:46:53 The driver lifespan is based on capacitor working temperature.

Installation Building material above fitting A-gap above the fitting Install requirements 25mm Building material or thermal insulation Building material B-gap to the building material 25mm C-gap to the thermal insulation 25mm Ceiling Opening Connect Power supply Spring Clips 1 2 A. Hold back spring clips Finish Spring Clips Ceiling B. Push downlight into position 3 4 Packaging Information SIZE(CM) N.W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 46*46*29.5.34 17 48 2'' standard container 4'' standard container CTNS Q'TY(PCS) VOLUME(CBM) 441 21168 28 882 42336 56 Tlf.: 37 16 4 Holthesvei 2, 4848 ARENDAL