AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO MANUEL D INSTALLATION INSTALLATIONS-HANDBUCH

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

E S F I P D G DB A(1) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

FH052EAMT FH070EAMT E S F I P D G R DB A(2) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH RUSSIAN E HNIKA

OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG π Ã

Function Controller MCM-A100

OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES GEBRAUCHSANWEISUNG

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

Wireless Remote Controller

E S F I P D G R A DB A(3) E HNIKA RUSSIAN

Outdoor unit MH18AP1(P2)X MH19AP1(P2)X MH24AP1(P2)X MH26AP1(P2)X

UH175GCM UH175GZM. Ventiltype Klimaanlage (Kühlen und Wärmen) KÏÈÌ ÙÈÛÙÈÎfi T appleô AÂÚ ÁˆÁÔ (æ ÍË Î È ÚÌ ÓÛË )

Type ACH1800E ACH2400E CH18ZA CH24ZA CH18CA CH24CA

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH

Air Conditioner. user installation & manual manual. imagine the possibilities

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INVERTER SPLIT - TYPE

Safety Precautions WARNING INSTALLING THE UNIT POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

[FLARE CONNECTION TYPE] ATTENTION

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

Split-type Room Air Conditioner (Cool) Aire acondicionado doméstico sistema Split (Refrigeración) Climatiseur de type Séparé (Refroidissement)

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Installation manual for room air conditioner

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

ROOM AIR CONDITIONER INSTALLATION MANUAL

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Choosing the installation site. Installation. 07 Choosing the installation site

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

AIR CONDITIONER (MULTI-SPLIT TYPE)

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

42PHW / 42PHQ 42PHQ...K

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

INSTALLATION MANUAL. R410A Split Series. Models ARX20GV1B ARX25GV1B ARX35GV1B ARX20JV1B ARX25JV1B ARX35JV1B. Installation manual R410A Split series

Installation Instructions

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

INSTALLATION INSTRUCTIONS

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

R410A SPLIT SERIES DC INVERTER

SPLIT-TYPE ROOM AIR CONDITIONER

INSTALLATION MANUAL. R-410A Split Series. Models. Installation manual R-410A Split series. Installationsanleitung Split-Baureihe R-410A

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

1. BEFORE INSTALLATION

Split-type Air-Conditioner

Split-type Air-Conditioner

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E. For OUTDOOR USE only.

DAIKIN AIR CONDITIONER

Notices for installation

Saunier Duval Clima, S.A.

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

1. BEFORE INSTALLATION

INSTALLATION MANUAL. R410A Split Series. Models ATX20J2V1B ATX25J2V1B ATX35J2V1B. Installation manual R410A Split series

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

SPLIT -TYPE ROOM AIR CONDITIONER

Installation Manual Forest Series All Model Numbers

Split-type Air-Conditioner

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

GMZ3-24H-S GMZ4-28H-S GMZ4-36H-S

SPLIT WALL-MOUNTED AIR CONDITIONER

Installation Instructions

Window-Type Air Conditioner

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

MODELS DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL FTXN50KV1B FTXN60KV1B. R410A Split Series

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

INSTALLATION MANUAL. R410A Split Series

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Saunier Duval Clima, S.A.

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

1. BEFORE INSTALLATION

UltraV Series Outdoor Units

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E. Model name: Slim Duct Type.

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Mini-Split Air Conditioner

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

INSTALLATION MANUAL. R410A Split Series. Models RN60E3V1B. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

High Wall Split Air Conditioners 53QHCT KHCT

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Installation Instructions

Transcription:

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION MANUALE D INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH E XEIPI IO E KATA TA H Indoor unit AQ07P8GE AQ07PBGE AQ07S8GE AQ07SBGE SH07ZPG SH07ZPGA SH07ZS8 AQ09P8GE AQ09PBGE AQ09S8GE AQ09SBGE SH09ZPG SH09ZPGA SH09ZS8 AQ12PBGE AQ12SBGE AQ12PGGB AQ12PGGE AQ12SGGB AQ12SGGE SH12ZPG SH12ZPGA SH12ZSG Outdoor unit UQ07P8GE UQ07PBGE UQ07S8GE UQ07SBGE SH07ZPGX SH07ZPGAX SH07ZS8X UQ09P8GE UQ09PBGE UQ09S8GE UQ09SBGE SH09ZPGX SH09ZPGAX SH09ZS8X UQ12PBGE UQ12SBGE UQ12PGGB UQ12PGGE UQ12SGGB UQ12SGGE SH12ZPGX SH12ZPGAX SH12ZSGX Split-type Room Air Conditioner (Cool and Heat) Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción) Climatiseur de type Séparé (Refroidissement et Chauffage) Condizionatore d aria per ambienti ad unità Separate (Raffreddamento e Riscaldamento) Aparelho de ar condicionado tipo Split (Refrigeração e Aquecimento) Geteilte raumklimaanlage (Kühlen und Wärmen) IAIPOYMENO K IMATI TIKO ømatioy(æ ÍË Î È ÚÌ ÓÛË) DEUTSCH PORTUGUÊS ITALIANO FRANÇAIS ESPAÑOL ENGLISH E HNIKA E S F I P D G DB98-07972A(7)

Safety Precautions WARNING Do not attempt to install this air conditioner by yourself. Install according to this installation instruction strictly. Install the unit securely in a place which can bear the weight of the unit. Use the attached accessories parts and specified parts for installation. For electrical work, follow the local national wiring standard, regulation. Do not use intermediate connection of the power cord or the extension cord and do not share the single outlet with other electrical. Check that the refrigerant gas do not leak after installation has completed. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle. CAUTION This equipment must be earthed. Do not connect the earth a gas pipe, water pipe, lighting rod or telephone earth. Do not install the unit in a place where an inflammable gas leaks. Perform the drainage / piping work securely according to the installation manual. Fasten a flare nut with a torque wrench as specified in this manual. E-2

ENGLISH Contents PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner... 4 Air Conditioner and Accessories... 6 INSTALLING THE UNIT Fixing the Installation Plate... 7 Purging the Unit... 7 Connecting the Assembly Cable... 8 Installing and Connecting the Indoor Unit Drain Hose... 9 Installing and Connecting the Outdoor Unit Drain Hose... 9 Installing and Connecting the Indoor Unit Assembly Piping... 10 Cutting/Extending the Piping... 11 COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit... 12 Performing Leak Tests... 13 Placing the Indoor Unit in Position... 13 Fixing the Outdoor Unit in Position... 14 Checking and Testing Operations... 14 Explaining Operations to the Owner... 15 TECHNICAL SPECIFICATIONS E-3

PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: Combustible gases Saline air Machine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions, first consult your dealer. Indoor Unit There must be no obstacles near the air inlet and outlet. Install the indoor unit on a surface that can support its weight. Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the recommended length of 5 metres to be respected (15 metres maximum). Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance. Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite. Make sure that the water dripping from the drain hose runs away correctly and safely. Install the indoor unit on the wall which is far from the floor by more than 2.5meters. Outdoor Unit The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the cooling circuit and seriously damage the unit. Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds. Do not block any passageways or thoroughfares. Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours. Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended length of 5 metres to be respected (15 metres maximum). Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary noise and vibration. Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit. Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite. If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height is 7metres. Make sure that the water dripping from the drain hose runs away correctly and safely. CAUTION You have just purchased a split-type room air conditioner and it has been installed by your installation specialist. This device must be installed according to the national electrical rules. Max input power & current is measured according to IEC standard and input power & current is measured according to ISO standard. E-4

PREPARING THE INSTALLATION ENGLISH Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. 300 mm or more 125 mm or more 125 mm or more Wrap the refrigerant pipes and the drain hose up in the absorbent pad and the vinyl tape, refer to page 13. 300 mm minimum 600 mm minimum 15metres maximum 300 mm minimum 7metres maximum 600 mm minimum The appearance of the unit may be different from the diagram depending on the model. E-5

Climatiseur de type séparé Geteilte raumklimaanlage Climatiseur de type séparé Geteilte raumklimaanlage PREPARING THE INSTALLATION Air Conditioner and Accessories The following accessories are supplied with the air conditioner. The quantities are indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Batteries for Remote Control (2) Owner s Instruction Booklet (1) Installation Manual (1) OWNER'S INSTRUCTIONS MANUAL DE INSTRUCCIONES ISTRUZIONI PER L'USO MANUAL DE INSTRUÇÕES MANUEL D'UTILISATION GEBRAUCHSANWEISUNG OWNER'S INSTRUCTIONS MANUAL DE INSTRUCCIONES ISTRUZIONI PER L'USO MANUAL DE INSTRUÇÕES MANUEL D'UTILISATION GEBRAUCHSANWEISUNG Splut-type Room Air Conditioner Aire acondicionado doméstico sistema Split Condizionatore d'aria per ambienti ad unità Separate Aparelho de ar condicionado tipo Split Splut-type Room Air Conditioner Aire acondicionado doméstico sistema Split Condizionatore d'aria per ambienti ad unità Separate Aparelho de ar condicionado tipo Split Accessories in the Outdoor Unit Case 5-wire Assembly Cable (1) Drain Plug (1) Rubber Leg (4) The flare nuts are attached to the end of each evaporator in/out pipe or service valve. Use the nuts when connecting the pipe. The 5-wire assembly cable is depending on the option. If they are not supplied, Using the standard cable. The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly piping illustrated below. The following connection accessories may be supplied, depending on the option. If they are not supplied, it is recommended that you collect them together before starting to install the air conditioner. Assembly Piping, Ø6.35mm by 5m (1) Assembly Piping, Ø9.52mm by 5m (1) ( 07/09 ) Assembly Piping, Ø12.70mm by 5m (1) ( 12 ) PE T3 Foam Tube Insulation (1) Vinyl Tape, Width 50mm (1) Drain Plug (1) Rubber LEG (4) Pipe Clamps A (3) Pipe Clamps B (3) M3.8 x 20 Screws for Wood (10) M4 x 16 Tapped Screws (10) Drain Hose, length 2m (1) Putty 100g (1) If these accessories are supplied, they are located in the accessory box. E-6

INSTALLING THE UNIT Fixing the Installation Plate Before fixing the installation plate to a wall or window frame, you must determine the position of the 65 mm hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit. When facing the air conditioner in position on the wall, the piping and cable can be connected from the: Right Left Rear (right or left) 1 Determine the position of the pipe and drain hose hole using the right figure and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards. 2 If you are fixing the indoor unit to a... Then follow Steps... Wall 3. Pipe hole (Ø65mm) 07/09 (Unit : mm) Installation plate 30mm ENGLISH Window frame 4 to 6. 3 Fix the installation plate to the wall in a manner appropriate to the weight of the indoor unit. If you are mounting the plate on a concrete wall with anchor bolts, the anchor bolts must not project by more than 20 mm. 12 (Unit : mm) 100 158 19 4 Determine the positions of the wooden uprights to be attached to the window frame. 5 Attach the wooden uprights to the window frame in a manner appropriate to the weight of the indoor unit. 6 Using tapped screws, attach the installation plate to the wooden uprights, as illustrated in the last figure opposite. 90 165 45 Purging the Unit On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. Unscrew the caps at the end of each pipe. Result: All inert gas escapes from the indoor unit. To prevent dirt or foreign objects from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the piping. E-7

INSTALLING THE UNIT Connecting the Assembly Cable The outdoor unit is powered from the indoor unit via the assembly cable. If the outdoor unit is more than five metres away from the indoor unit, the cable must first be extended to a maximum of 15 metres. 1 Extend the assembly cable if necessary. 2 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit. 3 Remove the screw securing the connector cover. N1 1 2 3 N1 N1 1 1 N1 1 2 2 3 2 3 3 Indoor unit E E Outdoor unit 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals as shown in the figure. Each wire is labeled with the corresponding terminal number. 5 Pass the other end of the cable through the 65 mm hole in the wall. 6 Replace the connector cover, carefully tightening the screw. 7 Close the front grille. 8 Remove the terminal board cover on the side of the outdoor unit. 9 Connect the cables to terminals as shown in the figure. Each wire is labeled with the corresponding terminal number. 10 Connect the earth wires to the earth terminals. The designs and shape are subject to change according to the model. 11 Replace the terminal board cover, carefully tightening the screw. 12 Connect the power cable with the indoor unit. Power cable specification Model 07/09/12 Power supply AC 220-240V, 50HZ Power cable 3G, 1.0mm 2, 10/16A H05VV-F Interconnection cable 5G, 1.0mm 2 H07RN-F Power plug or circuit breaker Power plug with earth pole. (More than 10A) Connect the power cable to the auxiliary circuit breaker. An all pole disconnection from the power supply must be incorporated in the fixed wiring( 3mm). E-8

INSTALLING THE UNIT Installing and Connecting the Indoor Unit Drain Hose Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through the 65 mm hole drilled in the wall, check that none of the following situations occur. ENGLISH 5 cm less Ditch The hose must NOT slope upwards. The end of the drain hose must NOT be placed in water. Do NOT bend the hose in different directions. Keep a clearance of at least 5 cm between the end of the hose and the ground. Do NOT place the end of the drain hose in a hollow. To install the drain hose, proceed as follows. 1 If necessary, connect the 2-metre extension to the drain hose. 2 If you are using the extension, insulate the inside part of the extension drain hose with a shield. 3 Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight. 4 Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as shown in the illustrations above. Shield Drain hose Extension drain hose The hose will be fixed permanently into position once the whole installation has been tested for gas leaks; refer to page 12 for further details. Installing and Connecting the Outdoor Unit Drain Hose When using the air conditioner in the heating mode, ice may accumulate. During de-icing, the condensed water must be drained off safely. Consequently, you must install a drain hose on the outdoor unit, following the instructions below. 1 Insert the drain plug into the drain hole on the underside of the outdoor unit. Drain hole 2 Connect the drain hose to the drain plug. 3 Ensure that the drained water runs off correctly and safely. E-9

INSTALLING THE UNIT Installing and Connecting the Indoor Unit Assembly Piping There are two refrigerant pipes of different diameters: A smaller one for the liquid refrigerant A larger one for the gas refrigerant A short length of piping is already fitted to the air conditioner. You must extend this piping using assembly piping (optionally supplied). The connection procedure for the refrigerant piping varies according to the exit position of the piping from the indoor unit, as seen when facing the air conditioner in position on the wall: Right (A) Left (B) Rear 1 With a knife, cut out the appropriate knock-out piece on the rear of the indoor unit (unless you are connecting directly from the rear). B A 2 Smooth the cut edges. 3 Remove the protection caps on the pipes and connect the assembly piping to each pipe, tightening the nuts, first manually and then with a wrench, applying the following torque. Outer Diameter Torque (kg cm) 6.35 mm 144~176 9.52 mm 333~407 12.70 mm 504~616 If the piping must be shortened or extended, refer to page 11. 4 Cut off any excess foam insulation. 5 If necessary, bend the pipe round, along the bottom of the indoor unit and out through the appropriate hole, taking care to ensure that: The piping does not jut out from the rear of the indoor unit The bending radius is 100 mm or more 6 Pass the piping through the hole in the wall. 7 For further details on how to connect up to the outdoor unit and purge the circuit, refer to page 12. The piping will be insulated and fixed permanently into position once the whole installation has been tested for gas leaks; refer to page 13 for further details. E-10

INSTALLING THE UNIT Cutting/Extending the Piping ENGLISH Five metres of piping is supplied with the air conditioner(optional). This length can if necessary be: Extended to a maximum of 15metres Shortened as required If more than five metres of piping is required: The assembly cable must also be extended Refrigerant must be added to the circuit by an approved installer; otherwise, the indoor unit may freeze 1 Make sure that you have the required tools available (pipe cutter, reamer, flaring tool and pipe holder). 2 If you wish to shorten the piping, cut it using a pipe cutter, taking care to ensure that the cut edge remains at a 90 angle with the side of the pipe, and referring to the illustrations below for examples of edges cut correctly and incorrectly. Oblique Rough Burr 90 O O x x x 3 To prevent any gas from leaking out, remove all burrs at the cut end of the pipe, using a reamer. 4 Slide a flare nut on to the pipe and modify the flare. Outer Diameter (D) Depth (A) 6.35 mm 1.3 mm 9.52 mm 1.8 mm 12.70 mm 2.0 mm 5 Check that the flaring is correct, referring to the illustrations below for examples of incorrect flaring. x x x x Inclined Damaged Surface Cracked Uneven Thickness 6 Align the pipes to be connected and tighten the flare nuts first manually and then with a wrench, applying the following torque. Outer Diameter Torque (kg cm) 6.35 mm 144~176 9.52 mm 333~407 12.70 mm 504~616 7 For further details on how to connect up to the outdoor unit and purge the circuit, refer to page 12. E-11

COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit The outdoor unit is loaded with sufficient R22 refrigerant for 5 metres of piping. The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling/heating capacity and could lead to a malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as shown at the figure. Outdoor unit A B Indoor unit Gas pipe side C Liquid pipe side D 1 Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut. 2 Referring to the illustration opposite, tighten the flare nut first manually and then with a wrench, applying the following torque. Outer Diameter Torque (kg cm) 6.35 mm 144~176 9.52 mm 333~407 12.70 mm 504~616 3 Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port as shown at the figure. 4 Open the valve of the low pressure side of manifold gauge counterclockwise. 5 Purge the air from the system using vacuum pump for about 10 minutes. - Close the valve of the low pressure side of manifold gauge clockwise. - Make sure that pressure gauge show -0.1MPa(-76cmHg) after about - 10minutes. - This procedure is very important in order to avoid gas leak. - Turn off the vacuum pump - Remove the hose of the low pressure side of manifold gauge. Vacuum Pump The designs and shape are subject to change according to the model. 6 Set valve cork of both liquid side and gas side of packed valve to the open position. 7 Mount the valve stem nuts and the service port cap to the valve, and tighten them at the torque of 18N m with a torque wrench. Valve stem Stem cap B (liquid) A (gas) 8 Check for gas leakage. - At this time, especially check for gas leakage from the 3-way valve s stem nuts, and from the service port cap. Adding Refrigerant Refrigerant must be added if the piping measures more than 5 metres in length. This operation can only be performed by a qualified refrigeration specialist. If you have used... Then... Model 07/09 AQ12S SH12ZS AQ12P SH12ZP A 7.5 5.0 7.5 B 20 30 30 More than A metres of piping Less than A metres of piping B g of refrigerant (R22) must be added for each extra metre. The purge time is normal. Refer to the Service Manual for more details on this operation. E-12

COMPLETING THE INSTALLATION Performing Leak Tests Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks. C D ENGLISH To check for gas leaks on the... Indoor unit Then, using a leak detector, check the... Flare nuts at the end of sections C and D. Outdoor unit Valves on sections A and B. A B The designs and shape are subject to change according to the model. Placing the Indoor Unit in Position Once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate. 1 To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit. 2 Wrap the refrigerant pipes and the drain hose located at the rear of the indoor unit up in the absorbent pad. Triply wind the pipes and hose to the end of the indoor unit with the absorbent pad (make intervals of 20mm). 3 Wind insulating tape around the pipes, assembly cable and drain hose. 4 Place the resulting bundle carefully in the lower part of the indoor unit, making sure that it does not jut out from the rear of the indoor unit. 5 Hook the indoor unit on to the installation plate and move the unit to the right and left until you are sure that it is securely in place. Installation plate 6 Finish wrapping vinyl tape around the rest of the piping leading to the outdoor unit. 7 Using clamps (optionally supplied), attach the piping to the wall wherever possible. E-13

COMPLETING THE INSTALLATION Fixing the Outdoor Unit in Position Y mm X mm The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground). Model AQ P8 AQ S8 SH S8 AQ SG AQ PG SH SG SH PG(A) AQ SB AQ PB Rubber leg X 457 489 506 Y 254 300 252 1 Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit. 2 Attach the outdoor unit to the appropriate support using anchor bolts. 3 If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit, so that the fan can operate correctly. Certainly fix up its rubber leg, in order to prevent its vibration and noise. Checking and Testing Operations To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly. 1 Review all the following elements in the installation: Installation site strength Piping connection tightness to detect any gas leakages Connection wiring Heat-resistant insulation of the piping Drainage Earthing wire connection Correct operations (follow the steps below) 2 Press the / button. Result: The indicator lights on the indoor unit flash at half-second intervals. While the indoor unit opens, the indoor unit fan runs to start. 3 Press the / button. Result: The outdoor unit operates in cooling or heating mode as following the room temperature. 4 Air flow direction Press the / button and check that the air flow blades work properly. E-14

COMPLETING THE INSTALLATION Explaining Operations to the Owner Before leaving the premises on which you have installed the air conditioner, you should explain the following operations to the owner, making reference to the appropriate pages in the owner s instruction booklet. ENGLISH 1 How to start and stop the air conditioner. 2 How to select the operating mode and adjust the temperature and fan settings. 3 How to adjust the air flow direction. 4 How to set the timers. 5 How to remove and clean the filters. Once the owner is happy with the basic operations, hand over the owner s instruction booklet and this installation manual for storage in a handy and safe place. Technical Specifications Model Indoor unit AQ07P8GE AQ07PBGE AQ07S8GE AQ07SBGE SH07ZPG SH07ZPGA SH07ZS8 AQ09P8GE AQ09PBGE AQ09S8GE AQ09SBGE SH09ZPG SH09ZPGA SH09ZS8 AQ12PBGE AQ12SBGE AQ12PGGE AQ12SGGE SH12ZPG SH12ZPGA SH12ZSG AQ12PGGB AQ12SGGB Power Supply 220-240V~, 50Hz 220V~, 60Hz E-15

THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H Y KEYH KATA KEYA THKE A O: ELECTRONICS