TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

Similar documents
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

INSTALLATION INSTRUCTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE. AFFINITY MODELS: PS8*DH GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW/HORIZONTAL FURNACES STANDARD & Low NOx DESCRIPTION WARRANTY

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

TECHNICAL SPECIFICATIONS

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

TECHNICAL GUIDE MODELS: GY9F*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 95% AFUE DESCRIPTION WARRANTY FEATURES YTG-B-0907

HIGH EFFICIENCY AIR HANDLER

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

TECHNICAL GUIDE AFFINITY MODELS: PS9*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% TO 94% AFUE

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION ECM AIR HANDLERS MODELS: AHV SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

HIGH EFFICIENCY AIR HANDLER

36,000-62,000 BTUH Nominal Capacity

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ruud Standard Efficiency Air Handler

AIR HANDLERS AIR HANDLERS

TECHNICAL GUIDE MODELS: GM9S*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES BTG-A-0407

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Ruud Standard Efficiency Air Handler

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

Rheem Standard Efficiency Air Handler

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC

Rheem High Efficiency Air Handler

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

SPLIT SYSTEM HEAT PUMPS "ERC" Series

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

TECHNICAL SPECIFICATIONS

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

TECHNICAL SPECIFICATIONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500)

Rheem High Efficiency Air Handler

INSTALLATION MANUAL WARNING STANDARD PSC MODULAR MULTI-POSITION AIR HANDLERS MODELS: MP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Product Data. Convertible Air Handlers 1 1/2 5Ton

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

TECHNICAL GUIDE MODELS: GM9S*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW/HORIZONTAL FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES

Ruud High Efficiency Air Handler

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES

Vertical Upflow Horizontal Left Air Handlers

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Product Data. Convertible Air Handlers 1 1/2 5Ton

MERIT SERIES Up Flow / Horizontal

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 2 1/2 Ton

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Transcription:

TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact cabinets along with return air options in both the upflow and horizontal positions allow this unit to fit into tight spaces such as attics, crawl spaces, and closets. NOTE: For matching condensing units and performance data, refer to condenser technical guides. FEATURES ABINET -The compact and sturdy cabinet is protected with a durable, attractive finish to prevent rust. The cabinet is also insulated to prevent cabinet sweating. F6FP models have 3/4 insulation. BLOWERS - Blowers are sized to circulate air both quietly and efficiently. The direct-drive, multi-speed, efficient X-13 motors provide a selection of air volume to match any application. Motor speeds may be selected via quick connect terminal at the motor. Slide-out blower/motor assemblies provide for easy servicing. OILS - The rifled tube coil/aluminum fin coils produce high performance ratings and provide long lasting quality. The coils are capable of bottom return air in the upflow position, and right or left end return air in the horizontal position. FLEX-OILS - For added application flexibility, an orifice metering device or R-22 or R-410A TXV should be installed on Flexcoils in the field to meet the required refrigerant choice. ELETRI HEATERS - providing up to 25kW of heat are available as field installed accessories. Electric heaters are available in both single and three phase. EAS INSTALLATION - These fan coil units are designed to provide the lowest total installation cost. Accessible color coded control wiring, top and side power wiring knockouts, easy to install drain connections and electric heaters all combine to minimize installed cost on every job. ONTROL BOARD - The control board is equipped with low voltage terminal strips for easy installation. The control board is also equipped with plug-in receptacles for the auxiliary heaters. ISO 9001 ertified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org. FOR DISTRIBUTION USE ONL - NOT TO BE USED AT POINT OF RETAIL SALE

DIMENSIONS ALL DIMENSIONS ARE IN INHES AND ARE SUBJET TO HANE WITHOUT NOTIE. ERTIFIED DIMENSIONS WILL BE PROVIDED UPON REQUEST. SHIPPIN BRAKET* 10-3/8 REMOVE PRIOR 21-19/32 TO INSTALLATION F (2 SREWS) 10-3/8 3/4 F 4-1/8 J J DRAIN ONNETIONS FOR HORIZONTAL APPLIATIONS 4 VAPOR OPENIN LIQUID OPENIN D K A REAR 10-3/8 7-1/2 =DRAIN PAN FOOTPRINT MAX. FILTER LENTH (21 INHES) MAX. FILTER WIDTH (B MINUS 1-1/2 INHES) 3/4 3/4 K 61 23-1/2 2 DRAIN ONNETIONS FOR UPFLOW APPLIATIONS B FILTER AESS 018-048 E 18-3/8 BOTTOM VIEW 24-1/2 Model 060 21.5 20-1/4 BOTTOM OPENIN Dimensions Model 1 F6FP018H06T** 40-3/4 18 1. All models only available with factory installed horizontal drain pan. 2. Actual conduit size is shown in parenthesis. Dimensions Wiring K.O.s 2 A B J K D E F Height Width Depth Power ontrol 14-7/8 16-1/2 Refrigerant onnections Line Size F6FP024H06T** 40-3/4 18 14-7/8 16-1/2 7/8 (1/2) 3/4 12-1/8 F6FP030H06T** 40-3/4 21-1/2 18-3/8 20 1-3/8 (1) 3/4 22 F6FP036H06T** 40-3/4 21-1/2 18-3/8 20 7/8 (1/2) 3/8 7/8 F6FP042H06T** 50-3/4 24 20-7/8 22-1/2 7/8 7/8 (1/2) F6FP048H06T** 50-3/4 24 17-3/8 20-7/8 22-1/2 1-3/8 (1) 7/8 1-23/32 F6FP060H06T** 61 24-1/2 21-1/2 23-1/2 21-19/32 7/8 Liquid Vapor 5/8 2 Johnson ontrols Unitary Products

OIL TEHNIAL DATA Application Refrigerant onnection Type Face Area (Sq. Ft.) Deep Rows Fins Per Inch oil Slab Size H W Tube eometry Tube Dia. 432328-UT-B-0409 Fin. Type Metering Device F6FP018H06T** A/ & HP Sweat 3.40 2 14 14 17.5 1 x.886 3/8 Enhanced Field Installed F6FP024H06T** A/ & HP Sweat 3.89 2 14 16 17.5 1 x.886 3/8 Enhanced Field Installed F6FP030H06T** A/ & HP Sweat 3.89 3 11 16 17.5 1 x.886 3/8 Enhanced Field Installed F6FP036H06T** A/ & HP Sweat 3.89 3 11 16 17.5 1 x.886 3/8 Enhanced Field Installed F6FP042H06T** A/ & HP Sweat 5.35 3 12 22 17.5 1 x.886 3/8 Enhanced Field Installed F6FP048H06T** A/ & HP Sweat 5.83 3 12 24 17.5 1 x.886 3/8 Enhanced Field Installed F6FP060H06T** A/ & HP Sweat 6.80 3 12 28 17.5 1 x.886 3/8 Enhanced Field Installed OOLIN APAIT Blower Model Rated FM F6FP018H06T** 615 F6FP024H06T** 830 F6FP030H06T** 1050 F6FP036H06T** 1185 F6FP042H06T** 1400 F6FP048H06T** 1600 F6FP060H06T** 1850 Entering Air F MBH @ Evaporator Temperature and orresponding Pressure F / PSI (Dry / Wet Bulb) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 Upflow / Horizontal Positions Only 85 / 72 36.3 33.0 29.5 25.6 80 / 67 33.4 30.2 26.7 23.1 75 / 62 27.4 24.3 21.0 17.7 70 / 57 22.2 19.3 16.2 12.6 85 / 72 41.5 37.8 33.7 29.5 80 / 67 36.2 32.4 28.6 24.5 75 / 62 29.1 25.3 24.0 19.2 70 / 57 24.1 21.5 18.7 15.8 85 / 72 88.4 76.0 63.3 50.0 80 / 67 70.8 59.4 48.4 37.0 75 / 62 55.2 43.9 35.8 29.9 70 / 57 47.4 41.5 35.8 29.9 85 / 72 88.4 76.0 63.3 50.0 80 / 67 70.8 59.4 48.4 37.0 75 / 62 55.2 43.9 35.9 29.9 70 / 57 47.4 41.5 35.8 29.9 85 / 72 100.5 86.4 72.0 56.8 80 / 67 80.4 67.5 55.0 42.1 75 / 62 62.7 49.9 40.7 34.0 70 / 57 53.9 47.2 40.7 34.0 85 / 72 119.9 101.0 82.0 62.2 80 / 67 96.0 79.2 62.6 45.8 75 / 62 74.8 58.6 46.2 37.0 70 / 57 64.3 55.4 46.2 37.0 85 / 72 119.9 101.0 82.0 62.2 80 / 67 96.0 79.2 62.6 45.8 75 / 62 74.8 58.6 46.2 37.0 70 / 57 64.3 55.4 46.2 37.0 Johnson ontrols Unitary Products 3

AESSORIES Refer to Price Manual for specific model numbers. VERTIAL SUSPENSION KIT - The suspension kit is designed to be used with all sizes of fan coil units whenever the application requires vertical suspension of the unit. ELETRI HEATERS - shown under Electrical Data include sequencers and temperature dual limit switches for safe, efficient operation. ircuit breakers are provided where shown. BOLT-ON THERMAL EXPANSION VALVE - R-22 and R-410A TXV kits are available for enhanced efficiency. EXTERNAL FILTER RAK - The F6FP air handler requires an external filter rack be used, as there are no provisions for internally installed filter. For multi-position applications, specify filter rack assembly 1FR0824, which includes a 1 permanent filter. For horizontal applications, use filter rack 1RF0724. LIMITATIONS These units must be wired and installed in accordance with all national and local safety codes. Voltage limits are as follows: Normal Operating voltage Range 1 1. Utilization range A in accordance with ARI Std. 110. 187-253 Air flow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units: Entering Air Temperature Limits Wet Bulb Temp. ºF Dry Bulb Temp. ºF Min. Max. Min. Max. 57 72 65 95 EXTENDED AIRFLOW DATA 1 FOR 230 VOLT - HEAT PUMP MODELS Blower Motor Speed 230 Volt FM @ External Static Pressure - IW 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 High-1 1160 1123 1091 1056 1019 995 956 893 819 697 Med-High-2 1044 1010 975 936 898 863 825 794 740 635 F6FP018H06T** Medium-3 852 816 773 744 699 667 628 580 554 521 Med-Low-4 630 613 564 524 487 436 391 356 310 267 Low-5 680 523 455 415 372 339 287 247 208 High-1 1257 1218 1182 1141 1116 1080 1041 1003 956 871 Med-High-2 1116 1077 1044 1003 975 930 896 851 809 777 F6FP024H06T** Medium-3 858 834 784 755 710 664 621 584 558 533 Med-Low-4 734 698 621 589 541 468 457 392 348 252 Low-5 762 677 593 518 473 415 377 333 226 201 High-1 1154 1118 1091 1045 1011 972 900 856 843 645 Med-High-2 1013 999 955 918 893 854 817 785 624 587 F6FP030H06T** Medium-3 837 798 761 719 663 637 585 554 469 453 Med-Low-4 616 576 526 473 428 375 326 251 203 Low-5 526 466 417 355 290 252 High-1 1565 1539 1501 1474 1441 1406 1341 1257 1179 1112 Med-High-2 1383 1352 1317 1289 1256 1218 1179 1143 1090 1018 F6FP036H06T** Medium-3 1215 1185 1151 1119 1087 1049 1010 970 932 877 Med-Low-4 1012 971 930 892 850 808 772 713 672 616 Low-5 879 842 793 753 701 661 618 558 521 471 High-1 1922 1895 1876 1841 1812 1788 1760 1732 1707 1682 Med-High-2 1704 1677 1648 1615 1582 1555 1524 1495 1467 1439 F6FP042H06T** Medium-3 1445 1414 1375 1336 1298 1265 1229 1196 1164 1132 Med-Low-4 1303 1263 1220 1166 1136 1094 1055 1018 985 949 Low-5 1116 1054 996 953 907 859 818 779 740 703 High-1 2026 2006 1971 1937 1902 1866 1830 1801 1770 1692 Med-High-2 1799 1777 1753 1715 1671 1636 1590 1553 1521 1482 F6FP048H06T** Medium-3 1618 1583 1547 1498 1455 1411 1376 1340 1303 1238 Med-Low-4 1395 1355 1297 1245 1211 1175 1112 1056 1018 972 Low-5 1201 1112 1056 1012 958 912 876 814 763 732 High-1 2130 2090 2052 1983 1917 1801 1715 1610 1487 1332 Med-High-2 1902 1859 1824 1795 1756 1718 1649 1557 1450 1326 F6FP060H06T** Medium-3 1699 1666 1616 1593 1547 1518 1481 1451 1354 1250 Med-Low-4 1474 1425 1392 1353 1314 1282 1236 1226 1182 1137 Low-5 1255 1213 1174 1135 1098 1051 1004 954 839 798 NOTE: Air flow data shown above 1/2 w.c. external static pressure is for REFERENE ONL. Maximum allowable external static when electric heat is used is limited to 1/2 w.c. Maximum allowable external static pressure may also be limited by minimum FM requirements for proper Heat Pump operation. 1. Includes Return Air Filter and Largest Electric Heater. All F*FP series air handler units are UL Listed up to 1/2" w.c. external static pressure, including air filter, wet coil, and largest kw size heater. 4 Johnson ontrols Unitary Products

EXTENDED AIR FLOW DATA 1 FOR 208 VOLT - HEAT PUMP MODELS F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Blower Motor Speed 208 Volt FM @ External Static Pressure - IW 1. Includes Return Air Filter and Largest Electric Heater. All F*FP series air handler units are UL Listed up to 1/2" w.c. external static pressure, including air filter, wet coil, and largest kw size heater. 432328-UT-B-0409 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 High-1 1102 1067 1036 1003 968 945 908 848 778 662 Med-High-2 992 960 926 889 853 820 784 754 703 603 Medium-3 809 775 734 707 664 634 597 551 526 495 Med-Low-4 599 582 536 498 463 414 371 338 295 254 Low-5 646 497 432 394 353 322 273 235 High-1 1194 1157 1123 1084 1060 1026 989 953 908 827 Med-High-2 1060 1023 992 953 926 884 851 808 769 738 Medium-3 815 792 745 717 675 631 590 555 530 506 Med-Low-4 697 663 590 560 514 445 434 372 331 239 Low-5 724 643 563 492 449 394 358 316 215 High-1 1096 1062 1036 993 960 923 855 813 801 613 Med-High-2 962 949 907 872 848 811 774 746 593 558 Medium-3 795 758 723 683 630 605 556 526 446 430 Med-Low-4 585 547 500 449 407 356 310 238 Low-5 500 443 396 337 276 239 High-1 1487 1462 1426 1400 1369 1336 1274 1194 1120 1056 Med-High-2 1314 1284 1251 1225 1193 1157 1120 1086 1036 967 Medium-3 1154 1126 1093 1063 1033 997 960 922 885 833 Med-Low-4 961 922 884 847 808 768 733 677 638 585 Low-5 835 800 753 715 666 628 587 530 495 447 High-1 1925 1906 1872 1840 1807 1773 1739 1711 1682 1607 Med-High-2 1709 1688 1665 1629 1587 1554 1511 1475 1445 1408 Medium-3 1537 1504 1470 1423 1382 1340 1307 1273 1238 1176 Med-Low-4 1325 1287 1232 1183 1150 1116 1056 1003 967 923 Low-5 1141 1056 1003 961 910 866 832 773 725 695 High-1 1925 1906 1872 1840 1807 1773 1739 1711 1682 1607 Med-High-2 1709 1688 1665 1629 1587 1554 1511 1475 1445 1408 Medium-3 1537 1504 1470 1423 1382 1340 1307 1273 1238 1176 Med-Low-4 1325 1287 1232 1183 1150 1116 1056 1003 967 923 Low-5 1141 1056 1003 961 910 866 832 773 725 695 High-1 2024 1986 1949 1884 1821 1711 1629 1530 1413 1265 Med-High-2 1807 1766 1733 1705 1668 1632 1567 1479 1378 1260 Medium-3 1614 1583 1535 1513 1470 1442 1407 1378 1286 1188 Med-Low-4 1400 1354 1322 1285 1248 1218 1174 1165 1123 1080 Low-5 1192 1152 1115 1078 1043 998 954 906 797 758 NOTE: Air flow data shown above 1/2 w.c. external static pressure is for REFERENE ONL. Maximum allowable external static when electric heat is used is limited to 1/2 w.c. Maximum allowable external static pressure may also be limited by minimum FM requirements for proper Heat Pump operation. APPLIATION FATORS-RELATED FM VS. ATUAL FM % Of Rated Airflow 80% 90% RATED FM 110% 120% apacity Factor 0.96 0.98 1.00 1.02 1.03 Johnson ontrols Unitary Products 5

Physical and Electrical Data MODEL F6FP018H06T** F6FP240H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Blower - Diameter Width 10x6 10x8 10x8 10x8 11x10 11x10 11x10 Motor HP 1/3 1/3 1/3 1/2 3/4 3/4 3/4 Nominal RPM 1050 1050 1050 1050 1050 1050 1050 Voltage 208/230 208/230 Amps Full Load 2.8 2.8 2.8 4.1 6.0 6.0 7.0 Type Disposable/Permanent Filter 1 Size 16x20x1 16x20x1 20x20x1 20x20x1 20x20x1 22x20x1 24x20x1 Permanent Type Kit 1PF0601BK 1PF0601BK 1PF0602BK 1PF0601BK 1PF0602BK 1PF0603BK 1PF0604BK Shipping/Operating Weight (lbs.) 98/93 105/100 121/115 121/115 150/144 150/144 153/147 1. Field Supplied. ELETRIAL DATA - ooling Only Minimum ircuit Total Motor Amps ampacity 208V 230V 208V 230V 1. O..P. = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay Fuse. Max. O..P. 1 Amps/ Type Minimum Wire Size A.W.. F6FP018H06T** 2.8 2.8 3.5 3.5 15 14 F6FP024H06T** 2.8 2.8 3.5 3.5 15 14 F6FP030H06T** 2.8 2.8 3.5 3.5 15 14 F6FP036H06T** 4.1 4.1 5.1 5.1 15 14 F6FP042H06T** 6.0 6.0 7.5 7.5 15 14 F6FP048H06T** 6.0 6.0 7.5 7.5 15 14 F6FP060H06T** 6.0 6.0 7.5 7.5 15 14 KW & MBH ONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT FOR 230V OPERATION MULTIPL 240V TABULATED KW & MBH B.918 6 Johnson ontrols Unitary Products

ELETRIAL DATA - 1-208/230-1-60 F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Heater 1 Model 2HK*6500506B MAX. STATI & MIN. FM 1. 0 or as follows: 0 = No Breaker, 1 = Breaker. 2. See onversion Table below: 3. If first stage heat or 66 is connected to W1, otherwise refer to this table. Total Heat 2 KW Staging 3 432328-UT-B-0409 KW MBH W1 Only W2 Only W1 + W2 Static Tap 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK*6500806B 0.5 Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 2HK*6501006B Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 2HK*6500506B Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK*6500806B 0.5 Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 2HK*6501006B Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 2HK*6500506B Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK*6500806B Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 0.5 2HK*6501006B Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 2HK16501506B Medium 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 2HK*6500506B Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK*6500806B Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 0.5 2HK*6501006B Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 2HK16501506B Medium 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 2HK*6500506B Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK*6500806B Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 0.5 2HK*6501006B Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 2HK16501506B Low 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 2HK16500506B Med-Low 3.8 5.0 13.0 17.1 3.8 5.0 3.8 5.0 3.8 5.0 2HK16500806B Med-Low 5.6 7.5 19.1 25.6 3.8 5.0 5.6 7.5 5.6 7.5 2HK*6501006B Med-Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 10.0 7.5 10.0 0.5 2HK16501506B Med-Low 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 2HK16502006B Med-Low 15.0 20.0 51.2 68.3 3.8 5.0 11.3 10.0 15.0 20.0 2HK16502506B Med-Low 18.8 25.0 64.2 85.3 3.8 5.0 11.3 15.0 18.8 25.0 4HK*6500506 Medium 3.6 4.8 12.3 16.4 3.6 4.8 3.6 4.8 3.6 4.8 4HK*6500806 Medium 5.6 7.5 19.2 25.6 2.8 3.75 5.6 7.5 5.6 7.5 4HK*6501006 Medium 7.2 9.6 24.6 32.8 3.6 4.8 7.2 9.6 7.2 9.6 4HK16501506 0.5 Medium 10.8 14.4 36.9 49.1 3.6 4.8 7.2 9.6 10.8 14.4 4HK16501806 Medium 13.2 17.6 45.1 60.1 3.3 4.4 6.6 8.8 13.2 17.6 4HK16502006 Medium 14.4 19.2 49.2 65.5 3.6 4.8 7.2 9.6 14.4 19.2 4HK16502506 Medium 18.0 24.0 61.5 81.9 3.6 4.8 10.8 14.4 18.0 24 NOTE: All models available with factory installed horizontal drain pan. Johnson ontrols Unitary Products 7

ELETRIAL DATA - 1 (SINLE SOURE POWER SUPPL) - OPPER WIRE F6FP018H06T** F6FP024H06T** F6FP030H06T** F6FP036H06T** F6FP042H06T** F6FP048H06T** F6FP060H06T** Heater Model 1 Heater Amps 240V Min. ircuit Ampacity 1. 0 or 1 as follows: 0 = No Breaker, 1 = Breaker 2. OP = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay fuse. Field Wiring Max. O..P. 2 Amps/Type 75 Wire Size - AW 208V 230V 208V 230V 208V 230V 2HK*6500506B 20.8 26.0 29.5 30 30 10 10 2HK*6500806B 31.3 37.4 42.6 40 45 8 8 2HK*6501006B 41.7 48.7 55.6 50 60 8 6 2HK*6500506B 20.8 26.0 29.5 30 30 10 10 2HK*6500806B 31.3 37.4 42.6 40 45 8 8 2HK*6501006B 41.7 48.7 55.6 50 60 8 6 2HK*6500506B 20.8 26.0 29.5 30 30 10 10 2HK*6500806B 31.3 37.4 42.6 40 45 8 8 2HK*6501006B 41.7 48.7 55.6 50 60 8 6 2HK16501506B 62.5 71.2 81.6 80 90 4 3 2HK*6500506B 20.8 27.7 31.1 30 35 10 10 2HK*6500806B 31.3 39.0 44.3 40 45 8 8 2HK*6501006B 41.7 50.3 57.3 50 60 8 6 2HK16501506B 62.5 72.8 83.3 80 90 4 3 2HK*6500506B 20.8 30.0 33.5 30 35 10 8 2HK*6500806B 31.3 41.4 46.6 40 50 8 8 2HK*6501006B 41.7 52.7 59.6 60 60 6 6 2HK16501506B 62.5 75.2 85.6 80 90 4 3 2HK*6500506B 20.8 30.0 33.5 35 35 8 8 2HK*6500806B 31.3 41.4 46.6 45 50 8 8 2HK*6501006B 41.7 52.7 59.6 60 60 6 4 2HK16501506B 62.5 75.2 85.6 80 90 4 3 2HK16502006B 83.3 97.7 111.6 100 125 2 1 2HK16502506B 104.2 120.4 137.8 125 150 1 1/0 4HK*6500506 20.0 29.29 31.88 30 35 10 8 4HK*6500806 31.3 41.48 46.00 45 50 8 8 4HK*6501006 40.0 53.08 58.75 60 60 6 6 4HK16501506 60.0 74.75 83.75 90 90 3 3 4HK16501806 73.3 89.19 100.38 90 110 3 2 4HK16502006 80.0 96.42 108.75 100 125 3 1 4HK16502506 100.0 118.08 133.75 125 150 1 1/0 8 Johnson ontrols Unitary Products

ELETRIAL DATA - 1 Ø (MULTI-SOURE POWER SUPPL) - OPPER WIRE Min. ircuit Ampacity Max. O..P. 1 Amps/Type 75 Wire Size - AW Heater Model ircuit ircuit ircuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V F6FP030H06T** 2HK16501506B 26.2/29.3 45.1/52.1 30/30 50/60 10/10 8/6 F6FP036H06T** 2HK16501506B 27.2/30.1 45.1/52.1 30/30 50/60 10/10 8/6 2HK16501506B 28.8/31.7 45.1/52.1 30/30 50/60 10/10 8/6 F6FP042H06T** 2HK16501506B 30.1/33.0 45.1/52.1 30/35 50/60 10/8 8/6 2HK16501506B 30.8/33.6 45.1/52.1 35/40 50/60 8/8 8/6 F6FP048H06T** 2HK16502006B 53.3/59.6 45.1/52.1 60/70 50/60 6/4 8/6 2HK16502506B 31.8/33.6 45.1/52.1 45.1/52.1 35/40 50/60 50/60 8/8 8/6 8/6 4HK16501506 53.1 / 58.8 21.7 / 25.0 60 / 60 25 / 25 6 / 6 10 / 10 F6FP060H06T** 4HK16501806 49.5 / 54.6 39.7 / 45.8 50 / 60 40 / 50 8 / 6 8 / 8 4HK16502006 53.1 / 58.8 43.3 / 50.0 60 / 60 45 / 50 6 / 6 8 / 8 4HK16502506 49.3 / 56.5 43.3 / 50.0 21.7 / 25.0 50 / 60 45 / 50 25 / 25 8 / 6 8 / 8 10 / 10 1. OP = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay fuse. ELETRIAL DATA - 3 Ø - 208/230-3-60 MAX. STATI Total Heat 1 KW Staging 2 Heater Model & MIN. FM KW MBH W1 Only W2 Only W1 + W2 Static Tap 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V F6FP018H06T** 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 F6FP024H06T** 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 F6FP030H06T** 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 2HK06501525B 0.5 High 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 F6FP036H06T** 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 2HK06501525B 0.5 High 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 F6FP042H06T** 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 2HK06501525B 0.5 Low 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 F6FP048H06T** 2HK06501025B 0.5 Med Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 2HK06501525B 0.5 Med Low 11.3 15.0 38.6 51.2 3.8 5.0 7.5 10.0 11.3 15.0 4HK06501025 0.5 Medium 7.2 9.6 24.6 32.8 7.2 9.6 7.2 9.6 7.2 9.6 F6FP060H06T** 4HK06501525 0.5 Medium 10.8 14.4 36.9 49.1 10.8 14.4 10.8 14.4 10.8 14.4 4HK16502525 0.5 Medium 18.0 24.0 61.4 81.4 9.0 12.0 18.0 24.0 18.0 24.0 1. See onversion Table below. 2. If first stage heat is connected to W1/66, otherwise refer to Table below. ELETRIAL DATA - 3 - (SINLE SOURE POWERSUPPL) - OPPER WIRE Field Wiring Heater Min. ircuit Ampacity Max. O..P. 1 Amps 75 Wire Size - AW 208V 230V 208V 230V 208V 230V F6FP018H06T** 2HK06501015B 44.0 48.1 45 50 8 8 F6FP024H06T** 2HK06501025B 44.0 48.1 45 50 8 8 F6FP030H06T** 2HK06501025B 45.0 48.0 45 50 8 8 2HK06501525B 44.0 48.0 45 50 8 8 F6FP036H06T** 2HK06501025B 44.1 49.6 45 50 8 8 2HK06501525B 44.1 49.6 45 50 8 8 F6FP042H06T** 2HK06501025B 46.2 51.6 50 60 8 6 2HK06501525B 46.2 51.6 50 60 8 6 F6FP048H06T** 2HK06501025B 46.3 51.9 50 60 8 6 2HK06501525B 46.3 51.9 50 60 8 6 4HK06501025 34.8 37.6 35 40 8 8 F6FP060H06T** 4HK06501525 47.3 52.1 50 60 8 6 4HK16502525 72.3 81.0 80 90 4 3 1. O..P. = Over urrent Protection device, must be HAR type ircuit Breaker or Time Delay fuse. Johnson ontrols Unitary Products 9

FIELD WIRIN ONNETION - OOLIN ONL FIELD WIRIN ONNETION - WITH HEATER KIT THERMOSTAT R W OUTDOOR UNIT THERMOSTAT R W * OUTDOOR UNIT FAN OIL UNIT R W2 W1 O FAN OIL UNIT R W2 W1 O * NOTREQUIREDON2OR5KW FIELD WIRIN ONNETIONS - OOLIN MODELS WITH ELETRI HEAT WIRIN Air Handler ontrol Wiring Typical A/ - ooling only Applications THERMOSTAT AIR HANDLER BOARD 1-STAE AIR ONDITIONIN R R Air Handler ontrol Wiring Typical A/ with Electric Heat Applications AIR HANDLER THERMOSTAT BOARD 1-STAE AIR ONDITIONIN R R /2 /2 W1 1 1 W2 W2 W2 W2 W1 HUMIDISTAT* W1 W1 HUMIDISTAT* O O HUM HUM X/L X/L OM OM * Dehumidification control connection ( Humidistat jumper on FM selection board must be removed). FIELD WIRIN ONNETIONS - SINLE STAE HEAT PUMP ONTROL WIRIN - Air Handler And Newer UP Single Stage HP Systems Single Stage H/P with Standard Demand Defrost ontrol Board THERMOSTAT AIR HANDLER BOARD HEAT PUMP R R R /2 1 W2 W2 ** E W1 W1 66 W/W1 O O W O HUM HUMIDISTAT* X/L X/L X/L OM * Dehumidification control connection ( Humidistat jumper on FM selection board must be removed). NOTES: 1. Terminal on Air Handler ontrol Board must be connected for full FM and applications requiring 60 second Blower Off Delay for SEER enhancement. 2. Optional Dehumidification Humidistat contacts open on rise. 3. For F4FV model - Remove Humidistat Jumper on FM Selection Board - if used. 4. For F4FV model - For Heat Pump Applications - Remove Heat Pump Jumper on FM Selection Board. 5. To change quantity of heat during HP defrost cycle - Reverse connections at W1 and W2 on Air Handler ontrol Board. 10 Johnson ontrols Unitary Products

TPIAL INSTALLATION POWER WIRIN TO MAIN POWER SOURE SUPPL AIR POWER WIRIN ONTROL WIRIN REFRIERANT LINES THERMOSTAT TO ONDENSATE DRAIN FILTER AESS LOUVERED ELETRI HOT WATER HEATER (Must comply with water heater installation instructions) TPIAL APPLIATIONS UPFLOW HORIZONTAL RIHT HAND APPLIATION LEFT HAND APPLIATION Johnson ontrols Unitary Products 11

Subject to change without notice. Printed in U.S.A. opyright 2009 by Johnson ontrols, Inc. All rights reserved. Johnson ontrols Unitary Products 5005 ork Drive Norman, OK 73069 432328-UT-B-0409 Supersedes: 432328-UT-A-0109