What is a Secondary Pressure Drainer?

Similar documents
Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Steam: Yesterday, Today and Tomorrow The Use of Steam as an Efficient Heat Source

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

MFP14 Automatic pumps for condensate and other industrial fluids

MFP14 Automatic pumps. for condensate and other industrial fluids

Documento Descargado desde:

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Pump & Trap Combinations

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

CRU-S Series Stainless Steel Condensate Recovery Unit

PIP PNE00004 Steam Trap Guidelines

HEAT EXCHANGER FORMULAS & EXAMPLE

Efficient Steam System Design

Economical and simplified solutions that offer quality and optimum steam trap service.

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

Hoffman Specialty General Catalog

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc.

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

CRU 200 and 500 Series Condensate Recovery Units

Silhouette. Feedwater Heater. Boiler Feedwater

Fundamentals of Hydronic Design

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

CHAPTER 3 BASIC STEAM CYCLE

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Industrial Processing Solutions

To improve steam system efficiency and reliability,

SERIES 8796 SELF PRIMING PROCESS PUMPS ENGINEERING DATA

Series 1140 and 1141 Temperature Regulators

TANKLESS WATER HEATER HEATING SOLUTIONS

100 years of boiler technology leadership.

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

TECHNICAL. Series 18. Pump Packages

Introduction to Supermarket Vacuum Condensate Drainage Systems by AcornVac, Inc.

MaxiCoking Technology Breakthrough Technology for Improved Existing Delayed Coker Performance

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

InterSeptor Centrifugal Separators Operating & Maintenance Manual

spiraxsarco.com/uk Condensate recovery in industrial steam systems

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

SECTION STEAM CONDENSATE PUMPS

GIRTON CABINET WASHER MODEL 794A

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

STEAM AND TRAP FUNDAMENTALS

1.1 This section applies to air handling units for HVAC Systems.

WATER HAMMER something that never should occur in a steam system

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

- Pamphlet A2404 TLV. ertrap a ic I Pump & Pump/Trap. GP Series GT Series

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Strategies in Optimizing Condensate Return

BuildingName The Description of the Project P DOCUMENTS

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

ThermoMax Steam System Efficient. Reliable. Consistent.

Improving Dryer Efficiency

STEAM SYSTEMS TOP SAFETY ITEMS FOR STEAM OPERATIONS. July, 2018

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Boiler Basics. Design and operation

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

SUNOCO Heat Transfer Fluids

T F E

So far, we have covered the basic concepts of heat transfer and properties.

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Heat Recovery Units. Heat Recovery 1

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Steam System Best Practices Document No. 11

GESTRA Information A 1.7

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

The. Steam ONE-PIPE STEAM SYSTEMS

PVE SERIES POWER VENTER SYSTEM MANUAL

Transcription:

What is a Secondary Pressure Drainer? Written by Steve Kortheuer, Cam Spence, Mike Sneary, and the Fluid Controls Institute Secondary Pressure Drainer Section The Fluid Controls Institute (FCI) defines a Secondary Pressure Drainer (SPD) as A vessel which collects and discharges liquid by alternately pressurizing and depressurizing through a given valve arrangement, utilizing a secondary compatible vapor or gas pressure as the motive source. Collection and discharge of liquid is accomplished using an operating mechanism, which FCI defines as a sensing and valving arrangement of the SPD that alternately provides and relieves pressure from a secondary motive source in accordance with predetermined fluid levels within the SPD. (for a glossary of terms, see Appendix A) Another way to describe a Secondary Pressure Drainer is to say it consists of a vessel (tank), inlet and outlet check valves to control the direction of fluid flow, a liquid level sensing device, and a valve arrangement that allows for entrance and exhaust of a motive pressure into and out of the vessel. The purpose of an SPD is to transfer a liquid from point A to point B using a vapor such as steam, air, or a compatible inert gas under positive pressure to push the liquid out of the vessel and into the discharge line. Steam is the preferred motive medium due to its suitability over a wide range of applications. While steam is used most often as the motive medium, other compatible inert media may be used. It is important that manufacturers be consulted in such cases. Secondary Pressure Drainers can be used on either vented or non-vented systems, with the most common use being the collection and pumping of steam condensate. There are two types of SPD's, Type 1 (see Figures A-E) and Type 2 (see Figure F) which incorporates an automatic discharge valve. As steam gives up its heat energy, it turns into condensate, which should ultimately flow to a condensate return station. Secondary Pressure Drainers (SPDs) are one method of returning condensate, often replacing electric centrifugal pumps. This discussion focuses on the use of steam as the motive medium to pump steam condensate. How Does a Secondary Pressure Drainer Work? A complete SPD cycle comprises three stages, as follows: comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 1 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Fill Stage (See Figure A) Condensate flows by gravity from the receiver, through the inlet check valve, into the SPD. During this stage the motive pressure valve is closed and the vent valve is open to permit equalization of pressure between the receiver and SPD, which allows condensate to fill the SPD. The outlet check valve is generally held closed by the condensate return system pressure (or atmospheric pressure in cases where SPD is draining a vacuum system). The fill stage ends once the condensate level reaches the predetermined high level and the level sensing device activates the motive and exhaust valve arrangement simultaneously. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 2 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Discharge Stage (See Figure B) When the motive pressure valve opens and the exhaust valve simultaneously closes, motive pressure to enable discharge enters the vessel and builds. Once the motive pressure in the SPD exceeds the condensate return line pressure, the condensate in the SPD is discharged into the return line through the outlet check valve. The inlet check valve is held closed by the motive pressure. Condensate will continue to be discharged until the predetermined low condensate level is reached. The discharge stage ends once the condensate reaches the predetermined low level, and the level sensing device activates the motive and exhaust valve arrangement. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 3 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Equalization Stage (See Figure C) Activation of the motive and exhaust valve mechanism simultaneously closes the motive pressure valve and opens the exhaust valve, allowing the vessel pressure to equalize with the receiver. Once the pressure in the SPD is equalized with the receiver, the equalization stage ends allowing the complete SPD cycle to repeat itself. NOTE: The equalization and fill stages occur with the motive pressure and exhaust valves in the same position. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 4 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Types of Systems Tech Sheet #SPD 201 Atmospheric If the condensate is coming from multiple units of steam using equipment having varying steam pressures, normally the SPD and its receiver will be vented to atmosphere. The system must be designed such that all steam using equipment can drain by gravity to the receiver (see Figure D). If the sizing of the atmospheric receiver and vent pipe are correct, the condensate in the receiver will freely flash out and the maximum pressure in the vessel will be zero psig. However, if the vent line is too small and/or the receiver is too small, flash steam can build-up within the SPD vessel leading to condensate back-up, back up into the steam using This can cause wide temperature fluctuations, frozen steam coils, water hammer, thermal shock, erosion and/or corrosion of the steam using equipment and downstream piping, and an array of other problems. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 5 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Non-Atmospheric The SPD can be closed to atmosphere under the correct set of conditions. This would allow the condensate to be returned at a higher temperature, requiring less energy to reheat the condensate to boiler saturation temperature, and would eliminate venting flash steam to atmosphere. If condensate is coming from multiple units of steam using equipment having varying steam pressures, then a non-atmospheric system is not the best choice for optimum equipment performance. In such a case, the reservoir will stabilize at a positive pressure that may be higher than the lowest supply pressure to one of the units of steam using It is generally preferable to have steam traps between the steam using equipment and the SPD if multiple units of steam using equipment are being collected in the non-atmospheric reservoir. Non-Atmospheric installations require consideration of what is happening downstream of the SPD. If the condensate return line (discharge) pressure will always be higher than the supply steam pressure to the steam using equipment, the installation could utilize a Type I SPD arranged similar to Figure E. The equalization line from the SPD would connect to the reservoir. The equipment equalization line connects the reservoir to the steam using equipment to provide free flowing vapor space. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 6 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

If the condensate return line (discharge) pressure could be less than the supply steam pressure to the heat exchanger, the installation could utilize a Type II SPD arranged similar to Figure F. In this example, a separate automatic discharge valve is installed at the outlet of the SPD. The valve can be installed either internal or external to the SPD. The automatic discharge valve is designed to allow only liquid to discharge and to prevent loss of steam. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 7 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Installation Considerations Fill velocity of incoming condensate is increased by the distance the receiver/reservoir is above the SPD. This is known as fill head. The pumping capacity of an SPD will change as the fill head changes. If all other factors remain the same, the higher the receiver is above the SPD, the faster it will fill. This will increase the maximum pumping capacity of the SPD. There is a limit as to the maximum fill head before no appreciable additional increase in capacity is achieved. While the SPD is discharging condensate, and since the inlet check valve is held closed at this time, the SPD cannot accept additional condensate during the discharge stage. However, more condensate may be generated during this stage, and this condensate must be collected, necessitating a receiver/reservoir of a size sufficient to handle this volume. This receiver/reservoir will keep the condensate out of the steam using equipment (such as a heat comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 8 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

exchanger), allowing for the best possible heat transfer. Further eliminating condensate backup minimizes water hammer, corrosion, thermal shock, etc. Check valves are critical system components, and the selection of appropriate check valves is essential for proper operation of SPDs. Always use manufacturer s recommended check valves to ensure proper operation. Future articles will discuss the advantages of Secondary Pressure Drainers and typical applications. For typical use of Type 1 and Type 2 SPDs, refer to the following chart: SPD Selection Guide Chart Application SPD Type Condensate Recovery Type 1 Equipment Drainage Stall 150 psig Type 2 Stall > 150 psig Consult Manufacturer No Stall Type 1 comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 9 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

Appendix A Tech Sheet #SPD 201 Glossary of Terms The term receiver refers to a properly sized fabricated tank or pipe used to collect condensate in atmospheric systems. The term reservoir refers to a properly sized fabricated tank or pipe used to collect condensate in non-atmospheric systems. Atmospheric vent pipe refers to a properly sized and designed vent to handle flash steam. Automatic air vent refers to an automatic valve to discharge air. Stall is a condition in steam using equipment where the pressure differential from the steam using equipment outlet to the condensate return line has become negative. For further discussion of stall, see FCI Tech Sheet # SPD 202 comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 10 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

SECONDARY PRESSURE DRAINER SECTION MEMBERS and WEBSITES ARMSTRONG INTERNATIONAL, INC. ITT HOFFMAN KADANT JOHNSON MEPCO SPENCE ENGINEERING/NICHOLSON STEAM TRAP SPIRAX SARCO, INC. TLV CORPORATION WATSON MCDANIEL CO. comprising the leading manufacturers of fluid control and conditioning FCI Tech Sheets are information tools and should not be used as 7/20/10 Page 11 of 11 This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.

SPD vs. Electric Centrifugal Condensate Pumps Comparison Topics Electric Centrifugal Pumps SPD Type The following items are important system characteristics to compare when selecting from a choice of condensate drainage, pumping, or recovery product options 1750 3500 SPD I Pumps SPD II Pump / Traps DESIGN Sizing Requirements 2-3x 2-3x 1x 1x Less sensitive to TDH variation Less filling height / static head required Relatively less sensitive to NPSHA Easily used in wet, hazardous & explosive external environments Sump Applications Hot condensate sump application Most can operate without electricity Most can operate during localized electrical outages. Readily self adjusts to variations in back pressure. May require 240 / 480 volt electricity Many units temperature limited to less than 200 O F Standard models capable of operating 212 O F & above INSTALLATION Generally single building trade required Can be insulated Flexibility in application/sizing Utilizes steam, air and inert gas less expensive than electricity No seals, no motors, no impellers or electric components which frequently fail. Long life less maintenance required. Can easily drain heat exchangers in a non-flash (closed loop) system. Lower spare part inventory required. Minimal assemblies required for spare parts lower maintenance costs. Handles flash condensate easier Suitable motive pressure may not be available Discharge piping may require installing back pressure valve

Comparison Topics Electric Centrifugal Pumps 1750 RPM 3500 RPM Pumps Pumps SPD I Pumps SPD Type SPD II Pump / Traps MAINTENANCE & OPERATION Efficient operation through recycling of motive energy Generally low profile when properly installed Installed low cost option Very accepted in industries High level of repair knowledge required (high maintenance required) Low NPSH pumps Replacement impellers Requires sufficient NPSH Extremely NPSH sensitive Extremely TDH sensitive Extensive requirements for NEMA VII / XII environments Special requirements for high temperature environments Requires sufficient fill height for gravity drainage Additional cooling may be required Flash tank is always required Requires two building trades minimum Don't insulate pump/receiver Sized for specific narrow range of specific conditions (less flexibility) Generally higher maintenance required * Check valves are critical system components related to capacity ratings, and the selection of appropriate check valves is essential for proper operation of SPDs. Always use manufacturer s recommended check valves to ensure proper operation.