Combi B Alarm box. Mounting instructions

Similar documents
SCHMIDT LED Measured Value Display MD Instructions for Use

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

M2500 Engine Controller Installation Manual

Operating instructions 2-channel code lock. Item No

Fire Control Panel FS4000

PERMACONN PM1030 Includes DI300. Installation Manual

Auditcon 2 Series Commercial Safe Locks. Models 52/T52/252/552

DOLKPS1KB Programming & Installation Manual

600 Range Dialer Installation Manual. Version 1.0

IRIS Touch Firmware Enhancements and Additions from Version to Version

Interface and EOL Modules 8

FEC400 Series. Installation Manual

Sonos-SB Siren/Beacon

Installation, Operating and Maintenance Manual

EWR2 WIRELESS SIGNAL REPEATER

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Version 1.03 January-2002 USER S MANUAL

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

M1000 Alarm Annunciator

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

INSTRUCTION MANUAL A131 High Level Audible Warning System

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

Auditcon 2 Series Commercial Safe Locks Models 52 / T52 / 252/ 552

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Instruction manual. W440 AIS Sart Sniffer

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Control Panel User Guide

Technical Manual. Level Alarm Unit CARLA & WIDS

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

GUARDIAN : AUTOGUARD. User Manual

TW-8000 TAUT WIRE FENCE

Installation and Operating Instructions

AL800ULADA. NAC Power Extender. Installation Guide

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

User Manual. Security Systems Security System L208

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Interface Modules for SENTRI

WARNING FIRE DOOR CLOSING

INSTRUCTION MANUAL (ATEX / IECEx)

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

BX-MDI8 Input module for SecuriLine extended

M2000 Engine Controller

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

Building Technologies. FDUL221 en Line tester operating instructions for electricians

DOLKPL1KB DOLKPS1KB DOLKSF1KB

IGNIS 1520M AUTOMATIC FIRE EXTINGUISHING SYSTEM CONTROLLER

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Computer Room Guard Model VM Manual and Installation Instructions

SCR100 User Manual. Version:1.1 Date:Dec 2009

User Manual. Dryer Controller M720

Parameterisable compact fault annunciator with permanent display

ADE Gen4. Speech Dialler Engineering Information. Description. Features

XC10 Extinguishing control panels

Silent Alert Fire Safe System

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

General Purpose IO Technical Manual

Original operating instructions Safety switch with guard locking AC901S AC902S

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

ZM1 User Manual JVA TECHNOLOGIES.

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

Instructions manual. By-alarm. By-alarm Manager software

Orion ISS. Intrusion and Fire Alarm Panel. Signal-10. User s Manual

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Door Release Power Supply

AL600ULADA. NAC Power Extender. Installation Guide

Model 1104 Troubleshooting Guide

EVO192 v3.0 Fire and Burglary What s New

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Wireless Call Point ( )

Application, Installation, Operation & Maintenance Manual

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

CA60Plus. Installation manual

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

UNC100 Integra Manual

On the job around the clock 24/7: Fire detection systems

FP120-Z1 Power supply kit A (70 W) Technical Manual

GB-DAS. Installation and user manual DEVIreg 850 controller

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

LineGuard 2300 Program User Manual (FloBoss 107)

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

Wireless Keypads LKP(E)S8M Series

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

FIB_FGBS-001 Universal Binary Sensor

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Transcription:

Combi B Alarm box Mounting instructions EN

Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power supply... 3 3.2 Opening monitoring line... 3 3.3 Tamper line... 4 3.4 Lock monitoring line via the main bolt contact of the lock... 4 3.5 Input... 4 4 Installation... 5 4.1 Lock monitoring line via the main bolt contact of the lock... 5 4.2 Silent alarm... 6 4.3 Input... 6 5 Technical data... 7 5.1 Circuit diagram... 8 5.2 Connection diagram:... 9 Illustrations and tables Figure 1: Overall system... 3 Figure 2: Terminal strip... 5 Figure 3: Circuit diagram... 8 Figure 4: Connection diagram... 9 Figure 5: Layout diagram... 10 Table 1: Technical data... 7 Version 02-16-2016 Page 2 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G11065, G113066 1 Description To integrate the Combi B lock into a VdS-compliant intrusion detection system, the Combi B alarm box must be used. The box allows transmission of a threat alert (silent alarm) and of the status message of the bolt lock to an intrusion detection system. In addition, the operation of the lock can be disabled via an input. Finally, the box allows permanent power supply of the lock if a suitable supply by the IDS or a power pack is in place. 2 System overview Alarm box Alternatively: Omission alarm, OD/OST override or double code override Remote control disable Microswitch for bolt monitoring Silent alarm IDS (Optional) IDS 9-15 V, max 80 ma Permanent supply alternatively: via IDS alternatively: directly Figure 1: Overall system 3 Structure The alarm box makes the inputs and outputs of the lock available to an intrusion detection system (IDS) connected downstream. Installation and commissioning should be performed exclusively by authorized skilled personnel. The line resistors to be installed separately are not part of the scope of delivery and must be soldered in in accordance with the specifications of the manufacturer of the alarm technology. 3.1 Power supply Terminals: X1.1 (plus U on) and X1.2 (minus U on, or GND), see Figure 4 The power supply is 12V ±10% Maximum current consumption 80mA 3.2 Opening monitoring line Terminals: X1.3 to X1.8, see Figure 4 Line resistors, either R101, R103 or R104, see Figure 3 Depending on the structure and design of the secure storage unit, the door contacts, monitoring lines and tamper lines can be looped in or used as separate lines. Version 02-016-2016 Page 3 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 3.3 Tamper line Terminals: X1.9 to X1.12 and X2.1 and X2.2, see Figure 4 Line resistors, either R102 or R104, see Figure 3 An additional (external optional) tamper device can also be installed in the tamper line. The cover contact of the alarm box is part of the line. The cover contact is actuated by closing the alarm box. A connection to the opening monitoring line can also be provided as an option. 3.4 Lock monitoring line via the main bolt contact of the lock Terminals: X2.3 to X2.8, see Figure 4 Line resistors, either R105 or R106, see Figure 3 The main bolt contact of the lock forms part of the lock monitoring line. By alternative installation of a short-circuit bridge in R107 (see Figure 3), variant A or variant B, the contact can be used as NC or NO contact. Further possible connections for boltwork contacts or monitoring contacts can be incorporated in the line. 3.5 Input Terminals: X2.11 (plus U on) and X2.12 (minus U on, or GND), see Figure 4 U on = 12V ± 10% / I = 10mA +20% in as-delivered configuration Series resistor R110 for variant A or B, as desired / pre-configured for variant A with 1.2kΏ, see Figure 3 The lock has a signal input. This input is inactive ex works. Via the PC software (see PC Software Manual), the input can be configured as remote control disable, omission alarm, override of the opening delay / opening stand-by time or double code override (for details, see Combi B PC Software Manual). - If the remote control disable signal is active, the lock cannot be opened nor reprogrammed. In this case, each key press at the operating unit of the lock is acknowledged by the red LED flashing once. Notice: Opening by means of the emergency key is not blocked by the remote control disable. - An omission alarm is only triggered if prior to the code input no separate signal generator is pressed or no additional authorization is given. - The override function of the opening delay / opening stand-by time (OD/OST) has the effect that the opening delay time can be skipped when a switch is actuated (see above). - The double code override functions exactly as the OD/OW override, except that not the opening delay time is skipped, but the set double code is replaced by a simple code when a signal is active. Version 02-16-2016 Page 4 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G11065, G113066 4 Installation For installation, all components of the system (lock, input unit and alarm box) must be free of voltage. Please remove all connections of the lock and the batteries of the operating unit, if necessary. The alarm box must be provided with the required line resistors while de-energized. In the delivery state, the terminals X1 and X2 (see Figure 4) to the intrusion detection technology are in the close position. Open position Close Figure 2: Terminal strip To close the spring clamps, the white sliders are pushed toward the cable using a screwdriver (see Figure 2). The connected cable must then be checked for tight fit. Once the lock has been de-energized, the 8-pin interface cable of the alarm box is plugged into the "IN/OUT" socket at the Combi B lock. The 4-pin power cable of the alarm box is plugged into the "Power" socket at the Combi B lock. The Combi B alarm box must be supplied with power from an external voltage source. Either the KMH "Combi B alarm box power pack (article number 3002501230) or an alternative voltage source of the required specifications 9-15 volts DC, current consumption lock/box max. 80mA must be used, e.g. the supply of an IDS. The power pack or the alternative voltage source is connected to the two terminals X1.1 (U on) and X1.2 (GND, see Figure 4) of the alarm box. Despite the power supply of the lock by means of the alarm box ("Power" plug of the lock), the batteries must also be inserted again into the Combi B input unit. Without inserted batteries, a continuous undervoltage display will be shown at the lock (see operating instructions chapter 13.3)! 4.1 Lock monitoring line via the main bolt contact of the lock Terminals: X2.3 to X2.8, see Figure 4 Line resistors, either R105 or R106, see Figure 3 The main bolt contact of the lock forms part of the lock monitoring line. It does not have to be activated, but is always active. If variant A (see Figure 3) has been mounted, the main bolt contact will function as NC contact. However, if variant B (see Figure 3) has been mounted, the contact can be used as NO contact. Version 02-016-2016 Page 5 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 4.2 Silent alarm Terminals: X2.9 and X2.10, see Figure 4 Line resistor R108, see Figure 3 Short-circuit bridge for variant A or alternative B, as desired, on R109, see Figure 3 (variant A: switch contact normally closed; variant B: switch contact normally open) When the silent alarm is set at the lock for the first time, the output is switched once for four seconds for checking purposes (for the terminals and resistors, see above). To check the silent alarm later on in lock operation, an alarm code must entered at the lock. Unlike the actual opening code, the alarm code is entered with +/- 1 at the last digit (for more details on activating and entering an alarm code, please refer to the operating instructions Combi B chapters 9.5 and 10.4). If wired correctly, the appropriate alarm signal should arrive at the connected system (e.g. IDS). If this is not the case, the installation (see chapter 4.2) must be checked. Notice: If a master code has not yet been activated at the lock, but the installer code is still operating, no alarm will be triggered! More details can be found in the operating instructions chapter 8. Depending on the mounting position of the resistors in the box, the installer configures the silent alarm as NC contact (variant A, see Figure 3) or NO contact (variant B, see Figure 3) at the terminals of the box for the IDS. 4.3 Input Terminals: X2.11 and X2.12, see Figure 4 Series resistor R108 for variant A or B, as desired, see Figure 3 Depending on which functions are active (inactive ex works, others set via the PC software), the installation must be checked as follows: Notice: All functions must be checked under all circumstances with the storage unit open. To check the remote control disable, energizing must be carried out as described in chapter 4.3 and an opening intent must be carried out at the lock (see operating instructions chapters 8 and 10). If you receive a signal from the red LED each time a key is pressed, the disable function works correctly. If you can operate the lock as usual or even open or program it, the remote control disable does not work, and the installation must be checked. With the remote control disable functioning, you must also check whether it can be disabled again and whether the lock can be opened by means of the correct code. To test the omission alarm, the signal must be triggered (see chapter 4.3), a valid code must be entered at the lock and a check as to whether a silent alarm was triggered must be carried out. This must be followed by entering a valid code without triggering the signal prior to that and checking whether a silent alarm (duration 4 seconds) has now been triggered. If this is not the case, the installation and the setting of the lock must be checked by means of the PC software. Version 02-16-2016 Page 6 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G11065, G113066 To test the override of the opening delay/opening stand-by time, make sure that the opening delay/opening stand-by time at the lock is active (see operating instructions chapter 9.3). Now the signal must be triggered (see chapter 4.3) and a valid code must be entered at the lock. It should be possible to open the lock directly without starting the opening delay. If this is not the case, the installation and the setting of the lock must be checked. If the override is working, check whether the opening delay proceeds as programmed if the signal is not triggered. If the opening delay is not working properly, the opening delay programming of the lock must be checked (see operating instructions chapter 9.3). To test the double code (DC) override, make sure that the DC is active (see operating instructions chapter 9.4). Now the signal must be triggered (see chapter3.5) and a valid code must be entered at the lock. It should be possible to open the lock directly without expecting the second code. If this is not the case, the installation and the setting of the lock must be checked. If the override is working, check in a second step whether the DC is requested if the signal is not triggered. If no DC is requested, the DC programming of the lock must be checked (see operating instructions chapter 9.4). 5 Technical data Designation Data Remark Dimensions 85 mm x 85 mm x 26 mm Environmental class II Ingress protection IP 3X Bolt switching contact 30V DC/ < 0.1 A Tamper switch/cover contact 30V DC/ < 0.1 A Supply 12V DC +/-10% / max. 80mA Signal output Silent alarm 1A / 30V DC resistive load Switching capacity: 30W DC Alternative signal input Remote control disable 12V DC +/-10 % / 10 ma +20% incoming (only 1 Omission alarm 12V DC +/-10 % / 10 ma +20% signal possible OD/OST override 12V DC +/-10 % / 10 ma +20% at a time) Double code override 12V DC +/-10 % / 10 ma +20% Table 1: Technical data Version 02-016-2016 Page 7 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 5.1 Circuit diagram Figure 3: Circuit diagram Version 02-16-2016 Page 8 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G11065, G113066 5.2 Connection diagram: Figure 4: Connection diagram Version 02-016-2016 Page 9 of 10

Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Figure 5: Layout diagram Version 02-16-2016 Page 10 of 10