Automatic smoke barriers Supercoil Moducoil Stripecoil Smokeshield-S Fixed smoke barriers Supercoil fix Moducoil fix

Similar documents
Textile fire protection closures EI 30/90

International Customer Edition Date: June 2014

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

The national standards bodies of:

This document is a preview generated by EVS


This document is a preview generated by EVS

This document is a preview generated by EVS

Sýnishorn Maintenance - Qualification of maintenance personnel

Telematics Services. Vodafone Power to you. Vehicle Security and Remote Management in the palm of your hand. automotive.vodafone.

Founding - Magnetic particle testing

This document is a preview generated by EVS

Sýnishorn Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

CEN/TC 256 Overview. Presentation to ISCC January C Cork Chair CEN/TC CEN all rights reserved

Sýnishorn Windows and doors - Watertightness - Test method

SOUTH AFRICAN NATIONAL STANDARD

This document is a preview generated by EVS

This document is a preview generated by EVS

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

This document is a preview generated by EVS

Pillow Plate Heat Exchanger SYNOTHERM

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts

ILNAS-EN ISO :2017

English Version. This Technical Report was approved by CEN on 11 December It has been drawn up by the Technical Committee CEN/TC 135.

This document is a preview generated by EVS

Certificate of constancy of performance,

This document is a preview generated by EVS

This document is a preview generated by EVS

CEN/TR :2017. Framework for standardization of signatures - Extended structure including electronic identification and authentication

This document is a preview generated by EVS

ILNAS-EN ISO 23640:2015

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

This document is a preview generated by EVS

DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM PRODUCTS IRISH STANDARD I.S. EN 15102:2007. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

Pillow Plate Heat Exchanger SYNOTHERM

CRA24-B3 controlled residential ventilation

This document is a preview generated by EVS

Sýnishorn Safety of machinery - Permanent means of access to machinesry - Part 3: Stairs, stepladders and guard-rails

National foreword. Compliance with a British Standard cannot confer immunity from legal obligations.

Beckhoff short profile

This document is a preview generated by EVS

Gas meters - Additional functionalities

Sýnishorn Railway applications - Fire protection of railway vehicles - Part 2: Requirements for fire behaviour of materials and components

ErP 2009/125/CE. Directives Eco design Energy labelling

StolenVehicle Tracking

This document is a preview generated by EVS

Resilient, textile and laminate floor coverings - Classification (ISO 10874:2009)

Sýnishorn Specifications for patient handling equipment used in road ambulances - Part 1: General stretcher systems and patient handling equipment

Contents. EN :2012 (E) Issue 5 ( ) Page

This document is a preview generated by EVS

SOUTH AFRICAN NATIONAL STANDARD

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Sýnishorn Safety of woodworking machines - One side thickness planing machines

Porsche Classic Vehicle Tracking System FAQs

L-force Drive-based Safety. Safe, scaleable and above all integrated

English Version. Daylight of buildings

Sýnishorn ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 3: Standard penetration test

This document is a preview generated by EVS

Paper and board - Determination of grammage (ISO 536:2012)

Sýnishorn Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals

National foreword. Text affected

This document is a preview generated by EVS

English version. Alarm systems Terms and definitions

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

Fire classification of construction products and building elements

This document is a preview generated by EVS

Bathroom September 2010

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

This document is a preview generated by EVS

The winning formats in CEE Planet Retail Ltd October 2010

The advantages of closed heating systems. White paper

Log fired heating system

This document is a preview generated by EVS

This document is a preview generated by EVS

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Glass for home appliances and

PTG, SWT Series. Heat Recovery Systems

ISO INTERNATIONAL STANDARD

Cylindrical helical springs made from round wire and bar - Calculation and design - Part 1 : Compression springs

Porsche Classic Vehicle Tracking System FAQs

Heating with pellets kw

EN ISO Welding coordination Tasks and responsibilities. Schweißaufsicht Aufgaben und Verantwortung (ISO 14731:2006)

ISO INTERNATIONAL STANDARD. Steel cord conveyor belts Part 4: Vulcanized belt joints

Sýnishorn Specification for mortar for masonry - Part 2: Masonry mortar

Operation of electrical installations -- Part 1: General requirements

Foreword. A completely revised report for quicker and easier access to key information

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 1: General

Hexagon regular nuts (style 1) - Product grades A and B (ISO 4032:2012)

AutoM Click to go to the page. AutoM Auto Shaker Filter

This document is a preview generated by EVS

This document is a preview generated by EVS

Sýnishorn General requirements for components used in drains and sewers

Bathroom July Topics

Transcription:

Automatic smoke barriers Supercoil Moducoil Stripecoil Smokeshield-S Fixed smoke barriers Supercoil fix Moducoil fix

Certificate for the usability CE-label: A certificate for the usability according to the EN 20- is required. Classical, first class, automatic smoke barrier Classical, first class, automatic smoke barrier: Approval according to the Building Supervision for the characteristics of the complete smoke barrier in case of fire: Provided that basic demands from the valid product standard are missing, additional certificates become necessary. Smoke barriers always ask for an official approval document. According to the test standard EN 20- the following tests are necessary: Fire test, cycle test and a test for the tightness of the fabric Classification according to EN 20-: Temperature/time-classifications Modular automatic smoke barrier Class Temp. ( C) time (minutes) class Temp. ( C) time (minutes) D 30 600 30 DH 30 STTC 30 D 60 600 60 DH 60 STTC 60 D 90 600 90 DH 90 STTC 90 D 20 600 20 DH 20 STTC 20 DA 600 > 20 achieved time DHA STTC > 20 achieved time Application with higher temperatures STTC = Standard-Time-Temperature - Curve according to EN 363- Different drive units for a secure closing: Typ ASB Gravity Fail System Motorized closing (with batteries and fire resistant cables) Alarm position 2,5 m from floor V = 0,06 0,5 m/sec. Alarm position > 2,5 m from floor V = 0,06 0,3 m/sec. ASB 2 ASB 3 ASB 4 Automatic smoke barrier with the feasibility to pass through Required quality surveillance to achieve the CE -label according to the product standard EN 20-: Internal surveillance of the production according to the standard External surveillance by the MPA-BS (certificate ÜZ-3/358/97) 900:2000 by the VdS (certificate S 896002) Additional performance features due to 30 years of experience by Stöbich the specialist: Automatic smoke barrier to create rooms Innovation leader: many patents, e.g. Gravigen drive unit many awards, e.g. Award for Architectural Product Innovations large variety of control units Long time experience: more than 500 projects have been settled Premium quality: STTC 900 certification since 996 Highest expertise for the fabrics In-house development, in-house production of the fabrics, in-house coating and handling of the fabrics Static smoke barrier

Challenges & protection targets 90% of all victims die from smoke 70% of physical damages are caused by smoke The source of the fire as well as further sources of danger can not be detected by the fire brigade Safe escape routes due to adapted smoke protection classifications according to leakages, temperature loads and time classifications. Extinction of the fire by the fire brigade becomes easier as they can detect the origin of the fire. This is possible due to the smoke compartments avoid a spread of smoke to the complete room. Smoke barriers can increase the effectiveness of SHEV systems, i.e. the higher the smoke layer, the smaller the openings for exhaust air as well as for the fresh air intake openings. Smoke barriers serve to separate rooms for the mechanical smoke exhaust. Therefore the rating and the linked investment for exhaust fans can be reduced. A controlled flow of the smoke can be achieved by smoke barriers even with cross streams which may have a negative influence on the entrainment of the smoke especially in high rooms. Invisible smoke barriers do not only comply with highest architectural demands, but do also not limit the view. The Stripecoil system offers corresponding characteristics in case that in disadvantageous building structures escape routes have to be combined with smoke barriers. Even large numbers of persons (depending on the width of the system up to approx. 200 persons) can pass through the system. Fixed smoke barriers have the advantage of being very light weighted approx. kg/m² and offer an easy sealing of continuing pipes, ducts or cable trays.

Definition of the smoke exhaust concept and the linked requirements to the smoke barrier can be done according to the DIN 8232-2 and -5, calculation or a small scale test Remaining opening within the overlapping area Do you have to avoid any remaining opening? Supercoil offers smoke barriers with 50 m in one piece - therefore 0 % leakage within the overlapping area Remaining openings within the boundary area Do you have to avoid remaining openings caused by pressure load in boundary areas? Leakages caused by a missing guiding of the fabric Special side guides with rods sguarantee for a positive fitting in the boundary area for the complete height therefore 0 % leakage in the boundary area even in case of a pressure load. Remaining opening caused by deflection Is the deflection and the involved leakage a problem (a weight of the bottom bar of approximately 2 kg/m is common). bottom bar Stöbich System Supercoil offers a remarkably lower deflection due to the high weight of the bottom bars between 4,6 to 3,5 kg. bottom bar Demand for space Is the available space limited? Provided you do not like to have a drive unit for each element + number of drive units choose the Stöbich Supercoil system with corresponding control unit and large drive capacity independent from the drop length and up to 30 m widths. Closing of a ceiling and closing direction Do you require a clean sealing of a ceiling even for large dimensions? Do you have a fire protection concept which can not be achieved by using vertical smoke barriers? Stöbich Supercoil system offers an optical more significant design e.g. by the self levelling bottom bar. Supercoil offers various closing directions and adjusts to your protection concept. shadow gap self levelling bottom bar Reaction time and drop length Which drop length has to be achieved within 60 seconds? (standard is 4.800mm/60sec. according to EN 20-) Do you require an extreme drop length? (standard is 8,5 meters) 4800 mm 8,5 m in 60 sec. Alarm position Stöbich Supercoil system offers closing velocities to achieve a drop length of 8.500 mm within 60 seconds. Stöbich System Supercoil offers drop length of up to 20 meters. Alarm position 8500 mm 20 m in 60 sec. Temperature classification Is your protection concept asking for a higher temperature classification? 000 K - D type up to 600 C K D type up to 600 C 500 0 30 60 90 20 min t Stöbich Supercoil system can be supplied in different temperature classifications. - 000 DH type (STTC) up to.200 C 500 t 0 30 60 90 20 min

CE-label 076 - CPD 0060 Characteristics of the complete smoke barrier during a fire are corresponding to the approval no. Z-PA-III 4.935 The traditional automatic smoke barrier to match highest demands and large dimensions Without side guides With side guides Smoke barrier Supercoil made of one piece up to 50 m width and 9,5 m drop for highest time classifications in case of fire load D = up to 600 C and DH (STTC) no remaining openings within the casing area only drive unit is necessary, therefore reduced complexity for the installation using side guides achieves 0% leakage in reference to the total smoke barrier highest variability concerning engineering and design standard drive system Gravigen, that is closing without auxiliary energy, no fire resistant cables are necessary high number of cycles of the motor = 0.000 Dimensions Length of the system d Design with side guides Design without side guides width Bottom bar Length of the system d Length of the system Drop length d (mm) h (mm) Design with side guides Design without side guides width < 50 m < 3,5 m 90 200 < 50 m > 3,5 m 6 m 90 250 < 50 m > 6 m 9 m 235 290 * > 9 m 2 m 255 320 * Dimensions of the area which has to be sealed shall not be larger than 475 m 2. Bottom bar a = side guide b = gap without side guide

Range of casings Bottom bars Standard fixed bearing Standard floating bearing Range of special constructions Standard bottom bar 4,6 type Heavy bottom bar 9,6 type Self levelling bottom bar Range of side guides Side guide 05 R type 80 S type 05 R type 05 E type 05 E type 80 N type 80 E type 05 N type CE-classification Patented tubular motor with Gravity Fail Safe technology DH type (STTC) D type up to 600 C Labelling EN 20- Automatic smoke barrier Stöbich Supercoil system ASB / ASB 3 type, closing without electric power Temperature classification D60 DH20 (600 C / 60 min.) (.00 C / 20 min.) Closing speed (depends on the drive) Gap casing (a-f) Gap edges (g) embrasure Gap joint (h) Max. permeability of the smoke barrier fabric (max. 25m³/m²/h) from 0,5 m/sec. to 0,30 m/sec. e.g. drop length 9 m = within 60s in the closed position 0 mm g = 0 mm with side guides g = 5 mm + 30 mm for fixed bearing without side guide g = 30 mm + 30 mm for floating bearing without side guide 0 mm (standard ceiling installation) < m³/m²/h Test temperature at ambient temperature and at 200 C Free area casing Free area edges Free area joints = length of the casing x gap casing = Lx0= 0 mm² = D x gap edges = D x gap joint x number of joints EC conformity certificate = 076 CPD 0060 General approval from the Building Authority for the Z-56.429-96 fabric D = Drop length of the smoke barrier Joint Casing Edges

CE-label no. 076 CPD - 0076 Characteristics of the complete smoke barrier during a fire are corresponding to the approval no. Z-PA-III 4.936 The standard smoke barrier in a modular design Automatic smoke barrier Moducoil pre-manufactured single elements will be assembled to create one complete unit up to any width standard drop length of up to 8,65 m designed for the time classification and temperature loads D = 600 C standard drive system Gravigen, that is closing without auxiliary energy, therefore no fire resistant cables are necessary robust drive unit, applicable for a high number of cycles (up to 0.000 cycles), with approved hold open unit modular installation of the casings side by side or on top of each other connected bottom bar across all elements can be combined with a self levelling bottom bar alternatively with side guides Single element Length of the system Single element Design with side guides Design without side guides width Drop length Single elements up to 6m width Drop length d h t 2 h 2 (mm) (mm) (mm) (mm) 4,5 250 50 50 50 Bottom bar Length of the system Single element Single element Single element Design with side guides Design without side guides >4,8-8,5 m 290 65 65 65 a = side guide b = gap without side guide drop length 8500 drop length 8500 Bottom bar

Range of casings Bottom bar Single smoke barrier-wall Modular smoke barrier-wall (standard) Single smoke barrier-ceiling Modular smoke barrier-ceiling Range of side guides Wall Embrasure Niche CE-classification Patented tubular motor with Gravity Fail Safe technology D type up to 600 C Labelling EN 20- Automatic smoke barrier Stöbich Moducoil system ASB / ASB 3 type, closing without electric power Temperature classification D20 DH90 (600 C / 20 min.) (.00 C / 90 min.) Closing speed (depends on the drive) Gap casing (a-f) Gap edges (g) embrasure Gap joint (h) Max. permeability of the smoke barrier fabric (max. 25m³/m²/h) approx 0,5m/sec. e.g. drop length 9 m = within 60s in the closed position 0 mm g = 0 mm with side guides g = 20 mm + 20 mm without side guides 7 mm (standard ceiling installation) 0 mm (standard wall installation) < m³/m²/h Test temperature at ambient temperature and at 200 C Free area casing Free area edges Free area joints = length of the casing x gap casing = Lx0= 0 mm² = D x gap edges = D x gap joint x number of joints EC conformity certificate = 076 CPD 0076 General approval from the Building Authority for the Z-56.429-96 fabric D = Drop length of the smoke barrier Joint Casing Edges

Automatic smoke barrier Stripecoil CE-label no. 076 CPD - 0077 Characteristics of the complete smoke barrier during a fire are corresponding to the approval no. Z-PA - III 4.937 Smoke barrier with the feasibility to walk through although closing to the floor level creation of smoke compartments in alleyways respectively in escape routes with a passage of persons double-coil system with unlimited width drop length up to 3,5 m designed for the time classification and temperature load D = 600 C and DH up to 30 minutes passage of up to 300 persons per minute at a width of 3 m is possible standard drive system Gravigen, that is closing without auxiliary energy, no fire resistant cables are necessary translucent fabric to optimize the visibility in the area of the passage little demand for space for the casing, therefore no limitations in the height of the passage soft, elastic and interrupted bottom bar to avoid any injuries protected bottom bar against damages and vandalism Dimensions Length of the system Drop length 3,5 m

Range of casings Bottom bar Installation to the ceiling Lateral gaps Installation to the wall Elastic bottom bar with a tear proof fabric Lateral gap standard Lateral false gap CE-classification Patented tubular motor with Gravity Fail Safe technology DH type (STTC) D type up to 600 C Labelling EN 20- Automatic smoke barrier Stöbich Stripecoil system ASB / ASB 3 type, closing without electric power Temperature classification D60 DH30 (600 C / 60 min.) (.00 C / 30 min.) Closing speed (depends on the drive) Gap casing (a-f) Gap edges (g) embrasure Gap joint (h) Max. permeability of the smoke barrier fabric (max. 25m³/m²/h) approx 0,5m/sec. e.g. drop length 3,5 m = within 24s in the closed position 0 mm g = 0 mm g = 0 mm + 0mm 0 mm < m³/m²/h Test temperature at ambient temperature and at 200 C Free area casing Free area edges Free area joints = length of the casing x gap casing = Lx0= 0mm² = D x gap edges = D x gap joint x number of joints EC conformity certificate 076 - CPD - 0077 General approval from the Building Authority for the Z-56.429-96 fabric D = Drop length of the smoke barrier Joint Casing Edges

Automatic smoke barrier Smokeshield-S The automatic smoke barrier which creates sections and matches highest demands: rectangular or polygon shaped base area of the smoke barrier outer dimensions up to 6m and drop lengths of up to 6 m designed for a high time classification and temperature load D = 600 C and DH (STTC) no remaining openings neither in the upper area nor at the corners pillars are not necessary, although complete tightness even in case of high pressure small height of the casing approx. 50 mm standard drive system Gravigen, that is closing without auxiliary energy, no fire resistant cables are necessary redundant drive system as crash protection Dimensions Range of different runs of the smoke barrier Clear width Clear height

Range of casings Bottom bar Circumference of the system Drop length D mm H mm < 50 m < 3,5 m 400 25 < 50 m > 3,5 m < 6 m 400 225 At least 2 drive units and one additional drive unit for each 0 m over 20 m circumference CE-classification Patented tubular motor with Gravity Fail Safe technology DH type (STTC) D type up to 600 C Labelling EN 20- Automatic smoke barrier Stöbich Smokeshield-S system ASB / ASB 3 type, closing without electric power Temperature classification D60 DH20 (600 C / 60min.) (.00 C / 20 min.) Closing speed (depends on the drive) Gap casing (a-f) Gap edges (g) embrasure Gap joint (h) Max. permeability of the smoke barrier fabric (max. 25m³/m²/h) from 0,5m/sec. up to approx 0,30s/m e.g. drop length 9 m = within 60s in the closed position 0 mm g = 0 mm 0 mm < m³/m²/h Test temperature at ambient temperature and at 200 C Free area casing Free area edges Free area joints EC conformity certificate = length of the casing x gap casing = Lx0= 0 mm² = D x gap edges = D x gap joint x number of joints is applied for General approval from the Building Authority for the Z-56.429-96 fabric D = Drop length of the smoke barrier Joint Casing Edges

Fixed smoke barriers CE-no. 076 - CPD - 0076 / -0060 Characteristics of the complete smoke barrier during a fire are corresponding to the approval no. Z-PA-III 4.935 / Z-PA-III 4.936 The fixed smoke barrier is a cost saving solution provided that an automatic smoke barrier is not necessary. large dimensions are possible, unlimited widths heights depend on the wind pressure which may occur pending fixing or fixing at the lateral and lower area designed for the time classification and temperature load D = 600 C and DH (STTC) extremely small static load to the building structure, weight of the fabric between 0,4 and 0,7 kg/m² very easy sealing of systems which pass through the fixed barrier, e.g. pipes, ventilation lines, ducts, cable trays Dimensions Width of the fixed smoke barrier Height of the fixed smoke barrier

Range of fixings Bottom bar Range of lateral fixings CE-classification DH type (STTC) D type up to 600 C Labelling EN 20- Fixed smoke barrier Stöbich Moducoil fix / Supercoil fix elastic material Temperature classification D60 DH20 (600 C / 60 min.) (.00 C / 20 min.) Gap edges (g) embrasure Gap joint (h) Max. permeability of the smoke barrier fabric (max. 25m³/m²/h) 0 mm 0 mm g = 0 mm Test temperature at ambient temperature and at 200 C Free area edges Free area joints = D x gap edges = D x gap joint x number of joints EC conformity certificate 076 - CPD - 0076/-0060 General approval from the Building Authority for the fabric D = Drop length of the smoke barrier Z-56.429-96 / Z-PA-III 4.935 / Z-PA-III 4.936 Joint Casing Edges

Control units Central fire monitoring Static control of the smoke barriers by release of the detection loop detection line 4 push button, orange, behind glass release signal provided from site detection line 4 detection line 4 Stöbich fire protection central RZ 3, 7, 8 Central fire monitoring 3 or 3 for extended application AM for extended application AM 3 3 3 3 tubular motor am-i trigger unit tubular motor am-i trigger unit Central fire monitoring Static control of the smoke barriers by release of the detection loop release fire compartment release fire compartment 2 release fire compartment 3 Stöbich MC/REL Evaluation control Logic via hardware possible up to 3 detector groups tubular motor tubular motor tubular motor tubular motor tubular motor tubular motor tubular motor tubular motor tubular motor smoke section smoke section smoke section Static control of the smoke barriers by a release signal from the detection loop Central fire monitoring release fire compartment release fire compartment 2 release fire compartment 3 release fire compartment 4 up to 6 release groups free programmable for up are possible RS-Modul 5 RS-Modul 5 RS-Modul 5 RS-Modul 5 Rz7 - OP tubular motor tubular motor 2 tubular motor 3 tubular motor 4 tubular motor 5 tubular motor 6 Logic via CAN-BUS is free programmable for up to 6 detector groups Re-opening of the smoke barriers for the fire brigade / extinction and evacuation Controlled, motor-driven re-opening despite of fire alarm building control central fire alarm system AM SB 3 2 safe power supply tubular motor detection line 4 fire protection central RZ AM 3 tubular motor Re-opening of the smoke barriers for the fire brigade / extinction and evacuation central fire alarm system SB 2 safe power supply detection line 4 fire protection central RZ AM 3 tubular motor Re-opening of the smoke barriers central fire alarm system for short time opening of the escape route push button for manual re-opening timer defines the hold-open time SB 2 safe power supply caption = Ölflex 3G-0,75 mm² 2 = Ölflex 3G-,5 mm² 3 = Ölflex 9G-,5 mm² 4 = fire alarm cable J-Y(St)Y-BMK-2x2,0x0,8 mm² 5 = BUS cable J-Y(St)Y-2x2,0x0,8 mm² Tubular motor Stöbich Gravigen type Standard optional zu externen Modulen Connection cable Limit switch Gravigen Hold open unit 24V Drive motor Powerpack Power supply Trigger unit am functional integrity is not necessary adjustable stop at end pos. wearless and patented control of the closing velocity quality surveillance by the VdS range of power from 2 Nm up to 20 Nm complete functional integration in case of power failure, hold open time up to 0 min power-saving mains adaptor 230/24V/2VA control of the hold open unit

Installation situations Design for the steel components Fabric reaction to fire Coated Galvanised Stainless steel Polished Circle matt finished Grinded K 240 The Stöbich Supercoil system offers various options in refference to colours, surfaces and individual shapes. Germany: A2 classification approval no: Z-56.429-96 For fabrics: Protex 600. A2 Protex 700. A2 Modutex 600 A2 Ecotex 00 A2 B classification approval no: PZ-05366-3 For fabrics: Protex 600 P Protex 700 P Modutex 600 P Ecotex 00 P Europe: Test standard: DIN EN ISO 3823 + 476 Classification norm: EN 350- Test report: no. KB - 072 A2 - s, d0 For fabrics: Protex 600. A2 Protex 600 2S A2 Protex 00. A2 Modutex 600 A2 Ecotex 00 A2 Ecotex 00 SA2 Selection of fabrics for smoke barriers Temperature classification D = 600 C Temperature classification DH = STTC PROTEX 600 A2 PROTEX 00 A2

History of the Hidden Champion Simply Stöbich world market leader in the sector of invisible fire protection For more than 25 years we - Stöbich Brandschutz GmbH - actively work on developing fire protection engineering. We know: 90 % of all fire victims die from smoke and 70 % of all property damages are caused by smoke. Smoke barriers are one of our core competences. We, as a medium-sized-family business from Goslar, Germany are very proud on having achieved the position of the world market leader of different segments within the fire protection market. In recent decades we have invested an extensive amount of capital into research and development. Numerous national and international awards for innovations as well as patents proof the high level of our developments and of our products Made in Germany. We went in various directions for our R&D. Our primary vision was, to create smoke barriers which are adjustable to multiple architectural shapes and situations. Therefore we offer modular systems, which adapt almost to any protection concept. Through the complete value added chain Weaving Coating Processing of the fabrics within the Stöbich Group of Companies we have intensively analysed the use of new materials and we introduced successfully new product lines to the market. Those are once more the proof for our integral way of thinking. From practice, for practice, for our customer all over the world. This brochure gives you detailed information about protection concepts, protection targets and finally which solution respectively which product we offer correspondingly. Temperature classification DH = STTC Temperature classification D = 600 C PROTEX 00 A2 PROTEX 600 A2

cope of agreements for individual cases 40 consultants in Germany Safety for the planning and construction phase all projects are completed cope the test and approval processes ISO 900:2000 certified by the VdS Stöbich school in everything from one source solving problems due to special constructions Safety due to quality numerous patents substantial knowledge data base quality department safe maintenance processes participation in German Norm Committees Safety due to competence in research and knowledge participation in European Norm Committees choose the original, not a copy Safety means to have the best solution resulting from our innovation and experience safety by mature and intensively tested systems due to our innovation power we introduced 8 successful novelties to the market customer-specific developments the innovations were multiple awarded high investments into innovations You 5 years guarantee in combination with a contract for the maintenance supply of spare parts is guaranteed increasing turnover constant growth of the company Safety for future due to the solidity of the company existing since 980 service our own fabric manufacture our own fabric conversion many special constructions safe manufacturing process due to a large depth of the added value more than 0.000 systems are installed our own drive systems most experiences worldwide Safety due to experience more than 7.000 (approx. 50%) regular customers development and production of innovative control units as well as emergency power back up systems Award for innovations Invisible fire protection! Bauen im Bestand from the Federal Ministry MDR award for the TV series simply ingenious Certificate mips 2005, Moscow German Award of Innovation Headquarter Stöbich Brandschutz GmbH Pracherstieg 6 38644 Goslar, Germany Phone +49 (0) 53 2-57 08-0 Fax +49 (0) 53 2-5708 -99 Affiliate South Stöbich Brandschutz GmbH Gewerbehof 8 7344 Bopfingen, Germany Phone +49 (0) 73 62-96 4-0 Fax +49 (0) 73 62-96 4-50 Affiliate East Stöbich Brandschutz GmbH Geltestraße 2 0688 Landsberg, Germany Phone +49 (0) 3 46 02-5 52-0 Fax +49 (0) 3 46 02-5 52-50 Affiliate West Stöbich Brandschutz GmbH Max-Planck-Straße 3 59423 Unna, Germany Phone +49 (0) 23 03-9 86 89-0 Fax +49 (0) 23 03-9 86 89-50 International Representatives Australia Austria Belarus Belgium Bosnia and Herzegovina Bulgaria Croatia Cyprus Czechia Denmark Estonia Finland France Greece Great Britain Hong Kong Hungary Ireland Italy Latvia Liechtenstein Lithuania Luxembourg Macedonia Netherlands New Zealand Norway Poland Portugal Romania Russia Sweden Switzerland Serbia and Montenegro Slovacia Slovenia Spain Turkey Ukraine UAE USA 0/2008