Product Catalog VALVES

Similar documents
MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Thermostatic Expansion Valves Type TR 6

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

PULSE WIDTH MODULATING VALVES

Check valve Types NRV and NRVH

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Standard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP

Standard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

General information on refrigerant controllers

Thermostatic expansion valves for ammonia Type TEA

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Bulletin , March Electric Hot Gas Bypass Valves

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

64 66 Electronic Expansion Valve. 68 Q Series. 70 S Series T Series O Series R Series Four-Way Reversing Valve

These valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.

Filter Driers with Replaceable Core

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Liquid Distributor Type RD

LINE COMPONENTS VALVES

Tube-in-tube heat exchanger Type HE

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

PWM expansion valves 2028

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Energy Use in Refrigeration Systems

Emerson Superheat Control. The smart solution for your application

Tube-in-tube heat exchanger Type HE

M7100 Pressure Transducer

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Pressure switch KPU. Data sheet

T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.

y Small dimensions. Easy to install in refrigerated counters or cold rooms

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Air cooled industrial chillers

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Air Cooled Packaged Systems AIRAH Back to Basics

Fan speed controller Type Saginomiya XGE

Refrigerant Valves/Accessories

Sporlan Valve Division Parker Hannifan/CIC Group

REFRIGERATION PRODUCTS

JCseries EVAPORATIVE CONDENSER. engineering data

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

Call us today! (800)

Call us today! (800)

Call us today! (800)

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

DESIGN STANDARDS SECTION 15600

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Introduction of Hanbell and

Contour TM Screw Compressors

HERZ Differential Pressure Control Valve 4002

EC3-X33 Stand-alone Superheat Controller Technical Data

Installation Manual BCS2000/3000

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

13-1. Temperature Regulator

water to water heat pumps

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Condensate Drain Valves

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

REFRIGERATION PRODUCTS

Chapter-8 Capacity Control of Refrigeration Systems

Semi-hermetic GEA Bock Compressors. Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world

BALANCED PORT Q-VALVE

System Considerations for Refrigerant Blends with Temperature Glide

Head Pressure Control Valves

Easy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

OIL SEPARATORS APPLICATIONS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

M5200 Industrial Pressure Transducer

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

RQE Series Temperature Controllers

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

AHU Plus. DX Air Handling Units

Dual Pressure Controls

THERMOSTATIC EXPANSION VALVES

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Compressed air preparation Compressed air storage Moisture management. Catalog #1

ACMVTECH HIGH EFFICIENCY UNITARY AHU

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Transcription:

SUIKA CLIMATE Product Catalog VALVES CONTACT WEB Info@suikaclimate.com ADDRESS Fremont, CA, 94555 TELEPHONE +1 (800) 625 0589 +1 (510) 859 8003

Suika Climate Toeflex ABOUT US Suika Climate (US), Toeflex (non-us) is a well-established distributor and manufacturer specializing in HVAC-R components and customized end-toend solutions (commercial heat pumps, drying equipment etc.). Originally founded in South Africa in 1996, we have been headquartered in Chengdu, China since 2004. Starting as a supplier of refrigeration components for the local market, we have expanded into over 30 countries and are today internationally competitive in both commercial and residential HVAC-R applications. Our catalog of products are of high quality, follow key international standards and have necessary approvals and certifications. We pride ourselves in fast, clear and effective communication and believe in building a long-term relationships with customers that are mutually beneficial. We have served customers of all sizes and maintained decade long relationships with many of them. We sincerely appreciate the opportunity to serve you and hope to hear from you!

01 02 Solenoid Valve TXV PAGE 1-6 PAGE 7-19 03 eev 04 4-Way Reversing Valve PAGE 20-22 PAGE 23-29 05 Ball Valve 06 Check Valve PAGE 30-31 PAGE 32-35 07 Charge Valve PAGE 36-37 08 Service Valve PAGE 38-41

SOLENOID VALVE FDF SERIES (ANGLED) Application FDF Series solenoid valves are direct operated or pilot operated solenoid valves. They are mainly used in refrigerant control of various appliances such as refrigerating and freezing systems, air conditioners and heat pumps Features Specifications Low energy consumption Fully surrounded coil bracket, good operating performance and low temperature rise Great valve opening performance, high MOPD Highly reliable hard seal structure Applicable for various types of refrigerants Applicable for all common HCFC and HFC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507A Fluid temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 50 C / -22 to 122 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Insulation class: B Approvals: declaration according to PED or LVD, UL, and VDE Coil Parameters Model Code No. Voltage Frequency Power Voltage V Hz W Tolerance Insulation Class Enclosure Connection FDFX-046 320305003200 100 AC 85% to 110% FDFX-047 320305003300 110 AC 85% to 110% FDFX-048 320305003400 200 AC 50/60 7W / 5W 85% to 110% B IP54 Cable FDFX-049 320305003500 220 AC 85% to 110% FDFX-050 320305003600 230 AC 85% to 110% Note: Wire terminal, sheath, and length can be customized according to customer s requirement

Coil Please check our website for Coil Dimension Nominal Capacity Model R22 R134a R404a /R507 Capacity in [kw] Liquid Line Suction Gas Hot Gas R407C R410A R22 R134a R404a /R507 R407C R410A R22 R134a R404a /R507 R407C FDF2KA 1.0 0.9 0.7 0.9 1.1 0.1 0.1 0.1 0.1 0.1 0.5 0.4 0.4 0.4 0.5 FDF2A 1.6 1.5 1.1 1.5 1.7 0.2 0.1 0.2 0.2 0.2 0.7 0.6 0.6 0.7 0.9 FDF2.2A 2.6 2.4 1.8 2.4 2.7 0.3 0.2 0.3 0.3 0.4 1.2 0.9 1.0 1.2 1.4 FDF2.5A 4.0 3.7 2.8 3.7 4.2 0.5 0.3 0.4 0.4 0.5 1.8 1.5 1.5 1.8 2.1 FDF6A 11.2 10.3 7.8 10.5 11.8 1.3 0.9 1.1 1.2 1.5 5.1 4.1 4.2 5.0 6.0 R410A Valve Body Technical Parameters Model Version Actuation Port Size Flow Rate MOP Max OPD Min Connection Ød FDF2KA-002 Normally Opened mm inch m3/h gpm mpa psi mpa psi mpa psi mm inch 1.8 0.07 0.05 0.06 2.1 305 6.35 1/4 FDF2A-010 Direct 2.0 0.08 0.08 0.09 609 4.2-3.4 493 0 0 6.35 1/4 - FDF2.2A-010 Normally 2.2 0.09 0.13 0.15 4.5 2.1 305 6.35 1/4 652 FDF2.5A-010 Closed 2.5 0.10 0.20 0.23 2.1 305 6.35 1/4 FDF6A-010 Pilot 5.8 0.23 0.56 0.65 3.4 493 0.01 2 7.94 5/16

Style and Dimensions Dimensions Model Code No. Style E D A B G F mm inch mm inch mm inch mm inch mm inch mm inch FDF2KA-002 322705000300 B 10.9 0.43 54.0 2.13 36.0 1.42 36.0 1.42 17.0 0.67 11.0 0.43 FDF2A-010 322705000000 A 10.9 0.43 72.0 2.83 33.0 1.30 35.0 1.38 - - - - FDF2.2A-010 322706000100 A 10.9 0.43 72.0 2.83 33.0 1.30 35.0 1.38 - - - - FDF2.5A-010 322709000100 A 11.3 0.44 81.0 3.19 33.0 1.30 36.0 1.42 - - - - FDF6A-010 322713000300 A 11.3 0.44 80.0 3.15 33.0 1.30 35.6 1.40 - - - -

SOLENOID VALVE FDF SERIES (STRAIGHT) Application Features FDF Series solenoid valves are mainly used in refrigerant control of various appliances such as refrigerating and freezing systems, air conditioners and heat pumps Specifications Applicable in liquid, suction and hot gas pipe lines Available in various AC and DC electromagnetic valve coils Low energy consumption Great valve opening performance, high MOPD Special seal gasket Normally closed Applicable for all common HCFC and HFC refrigerants: R22, R134a, R404A, R407C, R410A, R507A Fluid temp range (C & F): -30 to 105 C / -22 to 221 F Ambient temp range: -40 to 55 C / -40 to 131 F Relative humidity: 0 to 95% RH Approvals: CQC, TUV, declaration according to LVD or PED Coil Parameters Model Code No. Voltage Frequency Voltage V Hz Tolerance FDFXQ-02 335101000204 220AC 50/60 85% to 110% FDFXQ-03 335101000304 110AC 50/60 85% to 110% FDFXQ-05 335101000504 24AC 50/60 85% to 110% FDFXQ-08 335101000804 12DC - 95% to 105% Insulation Class F Enclosure IP65 Connection FDFXQ-09 335101000904 24DC - 95% to 105% FDFXQ-03 335101001104 110AC 50/60 85% to 110% Cable with 0.15m DIN

Nominal Capacity Model R22 R134a R404a /R507 Capacity in [kw] Liquid Line Suction Gas Hot Gas R407C R410A R22 R134a R404a /R507 R407C R410A R22 R134a R404a /R507 FDF02 3.2 2.9 2.2 3.0 3.4 - - - - - 1.5 1.2 1.2 1.5 1.7 FDF03 5.4 5.0 3.8 5.1 5.8 - - - - - 2.5 2.0 2.0 2.4 3.0 FDF06 16 15 11 15 17 1.8 1.3 1.6 1.7 2.2 7.4 5.9 6.0 7.2 8.8 FDF10 38 35 27 36 40 4.3 3.1 3.9 4.0 5.3 18 14 14 17 21 FDF15 52 48 37 49 55 5.9 4.2 5.3 5.4 7.2 24 19 20 23 28.6 FDF20 116 107 80 109 121 13 9 12 12 15.4 53 43 44 52 56.1 FDF22 151 138 105 142 160 18 12 15 15 19 69 55 56 68 72.9 FDF25 201 186 141 189 215 23 16.3 20.4 21 27.8 92 73 75 90 110 FDF32 322 297 225 303 345 37 26.1 32.6 33.6 44.7 148 117 120 144 176 FDF40 503 464 351 473 535 57 40.8 51 52.4 69 231 183 188 224 275 R407C R410A (1) The working condition of liquid and suction gas rated cooling capacity: Evaporating Temp. Te=-10 C ; Liquid Temp. Before Valve: Tl=25 C ; Pressure Drop After The Valve ΔP=0.015 MPa. (2) The working condition of hot gas rated cooling capacity: Condensing Temp. Tc=40 C ; Pressure Drop Across The Valve ΔP=0.08 MPa; Hot Gas Temp. Th=65 C ; Subcooling ΔTsc=4K Please check our website for more detailed capacity and ordering information Valve Body Technical Parameters Model Flow Factor Kv (2) MOP (1) MOPD for liquid medium is about 0.1 MPa lower. (2) The Kv value is the water flow at a differential pressure of 0.1 MPa. Flow Unit: m3/h; Density: 1000 kg/m3. OPD Max. Pressure Difference [mpa] (1) (Gas) Max. Pressure Difference [psi] OPD Min Weight m3/h mpa psi AC DC AC DC mpa psi Kg Pound FDF02 0.16 0 0 0.4 0.9 FDF03 0.27 4.5 653 FDF06 0.8 0.6 1.3 FDF10 1.9 0.7 1.5 FDF15 2.6 0.02 2.9 1.0 2.2 3.1 1.8 450 261 FDF20 6.0 1.5 3.3 FDF22 8.0 1.5 3.3 4.2 609 FDF25 10.0 3.0 6.6 FDF32 16.0 0.03 4.4 4.3 9.5 FDF40 25.0 4.3 9.5

Styles Note: Please check our website for dimension details

THERMOSTATIC EXPANSION VALVE TA/TAE SERIES Application TA/TAE Series thermostatic expansion valves are used to adjust flow of refrigerant into the evaporator of smaller capacity refrigerations, heat pumps and air conditioning systems. The valve operates by controlling the refrigerant s superheat at the outlet of the evaporator. Features Specifications Supplied with both fixed and adjustable superheat setting Available with filter in the inlet tube Versions with and without external equalization, with and without bleed and with and without MOP Wide vaporizing temperature range Applicable refrigerants: R134a, R404A, R407C, R507A and R290 Max. bulb temperature: 120 C / 248 F Max. valve housing temerature: 150 C / 302 F Max. working pressure: 3.4 mpa / 493 psi Max. test pressure: 3.75 mpa / 544 psi Equalization connection: 6mm or 1/4 inch (solder ODF) Capillary tube length: 0.75m (30 inch) BP: 15% / 30% Approvals: UL, CE Standard and MOP Valves Evaporating Temperature Refrigerant -40 to 10 C -25 to 10 C -25 to 15 C -25 to 20 C Without MOP MOP 15 C MOP 20 C MOP 25 C R134a - 58 psig/ 5 bar 70 psig / 5.8 bar 83 psig / 6.7 bar R404A - 120 psig / 9.3 bar 140 psig / 10.7 bar 168 psig / 12.6 bar R290-93 psig / 7.4 bar 109 psig / 8.5 bar 123 psig / 9.5 bar R407C - 116 psig / 9 bar 136 psig / 10.4 bar 158 psig / 11.9 bar

Nominal Capacity Model R134a R407C R404A/R507C R290 TR kw TR kw TR kw TR kw TA/TAE 0 0.11 0.40 0.16 0.50 0.11 0.38 0.17 0.60 TA/TAE 1 0.25 0.90 0.30 1.10 0.21 0.70 0.32 1.20 TA/TAE 2 0.50 1.80 0.80 2.70 0.45 1.60 0.74 2.60 TA/TAE 3 0.78 2.70 1.10 3.80 0.60 2.10 1.10 3.90 TA/TAE 4 1.30 4.60 1.60 5.60 1.20 4.20 1.60 5.60 TA/TAE 5 1.90 6.70 2.50 8.60 1.70 6.00 2.40 8.40 TA/TAE 6 2.50 8.60 3.20 11.30 2.20 7.70 3.20 11.20 TA/TAE 7 3.00 10.50 4.90 16.70 2.60 9.10 4.70 16.50 The rated capacity is based on : 1. Evaporating Temperature Te=5 C ; 2. Liquid Temperature Tl=28 C; 3. Static Superheat SS=4K; 4. Opening Superheat OS=4K. Please check our website for more detail capacities Identification Example TAN/TAEN = Type(N=R134a,E=External Pressure Equalization) 0.78TR = Rated Capacity in Tons 2.7kW = Rated Capacity in kw R134a = Refrigerant MOP 20 = Max. Operation Pressure -25 ~15 C = Evaporating Temperature Range PS 34 bar = Max. Working Pressure BP 15 = Bleed 15% 430012301211 = Code Number BC0200001 = Date Marking Refrigerant R407C = Z R134a = N R404A/R507 = S R290 = P

Dimensions and Weight Angleway Non-Adjustable Size Weight Approx.: 0.19 kg Straightway Adjustable Size Weight Approx.: 0.22kg Note: Please check our website for ordering details

THERMOSTATIC EXPANSION VALVE TI/TIE SERIES Application TI/TIE series are used to control liquid flow into evaporators by sensing the refrigerant temperature at the evaporator outlet, where the bulb must be placed. This series is targeted for heat pumps, ice machines and beverage machines. Features Specifications Supplied with MOP (MOP15 C, MOP20 C) Interchangeable orifice assembly makes it easy to match capacity and storage For biflow systems, please contact us Applicable refrigerants: R134a, R404A, R407C, R507A Max. temperature: Bulb, when valve is installed: 100 C / 212 F Bulb, element not mounted: 60 C / 140 F Max. working pressure: 4.6 mpa / 667 psi Max. test pressure: 5.1 mpa / 740 psi Approvals: UL, CE Standard and MOP Valves Evaporating Temperature Refrigerant -40 to 10 C -40 to -5 C -40 to -15 C -60 to -25 C MOP 15 C MOP 0 C MOP -10 C MOP -20 C R404A/R507 8.3 bar 5.2 bar 3.4 bar 2.1 bar R407C 6.6 bar - - - R134a 3.8 bar 2.1 bar 1.0 bar - R410A 11.5 bar - - -

Orifice Assembly With Filter Nominal Capacity [TR] Nominal Capacity [kw] Orifice NO. R404A R404A R407C R134a R410A R407C R134a R410A R507 R507 Code NO. 0x 0.27 0.19 0.18 0.29 0.96 0.68 0.65 1.05 433900000001 0 0.53 0.34 0.37 0.6 1.87 1.2 1.3 2.08 433900000002 1 1.04 0.59 0.75 1.16 3.67 2.08 2.64 4.07 433900000003 2 1.41 0.73 1.05 1.57 4.96 2.55 3.7 5.52 433900000004 3 2.4 1.22 1.79 2.66 8.45 4.3 6.29 9.37 433900000005 4 3.67 1.82 2.83 4.04 12.9 6.4 9.97 14.27 433900000006 5 4.86 2.4 3.71 5.57 17.1 8.43 13.1 19.66 433900000007 6 5.82 2.87 4.42 6.55 20.5 10.1 15.6 23.05 433900000008 The rated capacity is based on: 1. Evaporating Temperature Te=4.4 C ; 2. Refrigerant Temperature Ahead of Valve Tl=37 C ; 3. Condensing Temperature Tc=38 C ; Please check our website for more detail capacities and instructions of selecting valve Identification TIES = Model (S: R404A) R404A = Refrigerant -40~+10 = Evaporation Temperature( C) MOP15 C = Max. Operation Pressure PS 46 bar = Max. Working Pressure 430002070801 = Code Number Refrigerant BC0300005 = Date Marking R407C = Z Inlet/Outlet Connections Flare Flare / Flare Solder Refrigerant R407C R134a R404A/R507 R410A Pressure Equalization Internal External Internal External Internal External Internal External R134a = N R404A/R507 = S R410A = L Capillary Tube Connection Inlet x Outlet [m] [in. in.] [mm mm] 1.5 3/8 1/2 10 12

Dimensions Note: Please check our website for dimension details Please click here for ordering detail

THERMOSTATIC EXPANSION VALVE TC SERIES Application TC series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant s superheat at the outlet of the evaporator. They can be used with various refrigerants under all working conditions. Typical applications are refrigeration systems such as freezers, ice makers, dehumidifiers, air conditioners and heat pumps at various evaporation temperature ranges. Features Specifications Straight way design Bi-directional design; balance port design Adjustable superheat MOP function(mop15 C) BP function Installation and collection types: ODF, Flare, MIO and ORFS Applicable refrigerants: R134a, R404A, R407C, R410A and R507a Max. sensor bulb temperature: 120 C / 248 F Max. valve body temerature: 150 C / 302 F Max. working pressure: 4.6 mpa / 667psi Max. test pressure: 5.1 mpa / 740 psi External balance connection: 1/4 in. / 6 mm (ODF welding) Capillary tube length: 1.5 m or 59 inch BP: 15% Approvals: UL, CE Standard and MOP Valves Evaporating Temperature Refrigerant -40 to 10 C -25 to 10 C Without MOP MOP 15 C R134a - 55 psig/ 5 bar R404A/R507-120 psig / 9.4 bar R407C - 95 psig / 7.5 bar R410A - 167 psig / 12.5 bar

Nominal Capacity Model TCE TCBE Orifice R134a R404A/R507 R407C R410A NO. TR kw TR kw TR kw TR kw 3.5 1.5 6.0 2.0 7.0 2.5 9.0 3.5 12.0 4.5 2.5 8.0 2.5 9.0 3.5 13.0 4.5 16.0 6.5 3.5 12.0 4.0 14.0 5.0 19.0 6.5 24.0 9 4.5 17.0 5.0 18.0 7.0 25.0 9.0 32.0 13 7.0 24.0 7.5 26.0 10.0 36.0 13.0 45.0 15 8.0 29.0 9.0 31.0 12.0 42.0 15.0 54.0 19 10.0 37.0 11.0 39.0 15.0 53.0 19.0 68.0 23 12.0 44.0 13.0 45.0 18.0 62.0 23.0 79.0 The rated capacity is based on: 1. Evaporating Temperature Te=5 C ; 2. Liquid Temperature Before Valve Tl=28 C ; 3. Condensing Temperature Tc=32 C ; 4. Static Superheat SS=4K; 5. Opening Superheat OS=4K. Please check our website for more detail capacities Identification Example TCEN = Valve Type (N-R134a) 4.5TR = Nominal Cooling Capacity in Tons 17kW = Nominal Cooling Capacity in kw R134a = Refrigerant -25~+10 C = Evaporating Temperature Range( C) MOP15 C = Max. Evaporating Pressure PS 46 bar = Max. Working Pressure 440011030300 = Code NO. BC0300005 = Date Marking. Connection Size Model TCE TCBE Connection Sizes Inlet Outlet ODF Welding Refrigerant R407C R134a R404A/R507 R410A = Z = N = S = L Capillary Lengths mm inch m 10х16 3/8х5/8 12х16 1/2х5/8 12х22 1/2х7/8 1.5 16х22 5/8х7/8 16х28 5/8х9/8 16х22 5/8х7/8 16х28 5/8х9/8 22х28 7/8х9/8 1.5 22х35 7/8х11/8

Dimensions Please check our website for ordering details Click here for more dimension details

THERMOSTATIC EXPANSION VALVE TCCE SERIES Application TCCE thermostatic expansion valves are used to regulate refrigerant flow into evaporators, especially in applications such as residential air conditioning systems, split systems, roof top units, heat pumps, light commercial air conditioning systems and chillers. Features Specifications Compact size - hermetic design Versions with and without check valve For product with BP function or special installation, please contact us Various installation modes (Flare, Solder, MIO, ORFS) Applicable for all common HCFC and HFC refrigerants such as: R32, R290, R134a, R404A, R407C, R410A and R507A Max. bulb temperature: R407C: 100 C or 212 F R410A: 75 C or 167 F Max. valve body temerature: 110 C / 230 F Max. working pressure: 4.6 mpa / 667psi Max. test pressure: 5.1 mpa / 740 psi Options for connections: ODF(3/8, 1/2, 5/8), ODM, etc. Equalization: 1/4 in. (ODF) 1/8 in. (ODF/ODM) Capillary tube length: 800mm or 31 inch Approvals: UL, CE

Nominal Capacity Orifice R134a R407C R404A/R507C R410A R290 R32 NO. TR kw TR kw TR kw TR kw TR kw TR kw 2 1.3 4.6 1.6 5.6 1.2 4.2 2.0 7.0 1.8 6.3 2.9 10.2 2.5 1.6 5.6 2.1 7.4 1.6 5.6 2.5 8.8 2.2 7.7 3.6 12.6 3 2.0 7.0 2.5 8.8 1.9 6.7 3.0 10.5 2.6 9.1 4.3 15.1 3.5 2.3 8.1 2.9 10.2 2.2 7.7 3.5 12.3 3.1 10.9 5.0 17.5 4 2.6 9.1 3.3 11.5 2.5 8.8 4.0 14.0 3.5 12.3 5.7 20.0 5 3.3 11.5 4.1 14.4 3.1 10.9 5.0 17.5 4.4 15.4 7.2 25.2 6 3.9 13.7 4.9 17.2 3.7 13.0 6.0 21.0 5.3 18.6 8.6 30.1 7 4.6 16.1 5.8 20.3 4.3 15.1 7.0 24.5 6.1 21.4 10.0 35.0 The rated capacity is based on: 1. Evaporating Temperature Te=5 C ; 2. Liquid Temperature Before Valve Tl=28 C ; 3. Condensing Temperature Tc=32 C ; 4. Opening Superheat OS=4K. Please check our website for more capacities and ordering detail Check Valve Capacity Mass Flow lb/h ΔP (psi) Identification TCCEL = Valve Type (L:R410A) 2TR = Rated Capacity in Tons 7kW = Rated Capacity in kw R410A = Refrigerant -25~+20 C = Evaporating Temperature Range 440023130100 = Code NO. PS 46 bar = Max. Working Pressure BP 15 = Bleed 15% BB2800001 = Date Marking Refrigerant R407C R410A R134a R404A/R507 R290 R32 = Z = L = N = S = P = D

Inlet/Outlet Connections Options for Connections (In Out Equ) 3/8 3/8 1/4 ODF 3/8 3/8 1/8 ODF 3/8 1/2 1/4 ODF 3/8 1/2 1/8 ODF 1/2 1/2 1/4 ODF 1/2 1/2 1/8 ODF 1/2 5/8 1/4 ODF 1/2 5/8 1/8 ODF 3/8(OEM1) 5/8(Aeroquip) 1/8(635mm) 3/8(OEM2) 5/8(Aeroquip) 1/8(635mm) 5/8(Chatleff) 5/8(Aeroquip) 1/8(635mm) 5/8(Chatleff) 5/8(Aeroquip) 7/16(nut) 3/8(ODF) 5/8(Aeroquip) 1/8(635mm) 3/8(ODF) 5/8(Aeroquip) 7/16(nut) 3/4(Chatleff) 3/4(Aeroquip) 1/8(635mm) 3/4(Chatleff) 3/4(Aeroquip) 7/16(nut) Note: supply both with Check Valve and without Check Valve Dimensions Non-Adjustable

Adjustable

ELECTRONIC EXPANSION VALVE DPF(B) SERIES Application DPF(B) Series electronic expansion valves are designed for use in air conditioning and refrigeration systems, or in heat pumps. The valve controls the automatic adjustment of refrigerant flow rate to allow the system to work under optimized conditions (thus fast cooling or heating, precise temperature control and energy saving). The valve can also be used for suction line pressure controls. These valves provide bi-directional operation to control the refrigerant flow rate in heating or cooling mode. Features Specifications Low noise and high control precision Bi-directional flow Low power consumption and wide flow regulation range Superior self-lubricating thread Plastic packaging with anti-corrosion coil Advanced and highly reliable welding Good actuating performance Compact and light Applicable for all common HCFC and HFC refrigerants: R22, R32, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 70 C / -22 to 158 F (duty cycle rate below 50%) Ambient temp range: -30 to 60 C / -22 to 140 F (duty cycle rate below 50%) Relative humidity: 0 to 95% RH Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Medium flow direction: Bi-directional Life cycle: 100,000 Approvals: declaration according to PED or LVD, UL, and VDE Coil Parameters Item Parameter Full Stroke 500 pulses Opening Pulse 30±20 Rated Voltage DC12V±10%, rectangular wave Actuating Mode 4-phase 8-step permanent magnet Excitation Mode 1 to 2phase excitation Excitation Rate 30 to 40 PPS Insulation Class E Resistance 46±3.7Ω(Φ1.3~Φ2.4), 36±3.4Ω(Φ2.8~Φ3.2) (20 C) Current 260mA/phase(Φ1.3~Φ2.4), 330mA/phase(Φ2.8~Φ3.2) (20 C) Protection Class IP65

Nominal Capacity Model Orifice R22 R32 R134a R404A R407C R410A mm inch TR kw TR kw TR kw TR kw TR kw TR kw DPF(B)1.3C 1.30 0.05 1.51 5.3 2.87 10.1 1.17 4.1 1.05 3.7 1.54 5.4 1.76 6.2 DPF(B)1.65C 1.65 0.06 2.42 8.5 4.63 16.3 1.91 6.7 1.71 6.0 2.50 8.8 2.84 10.0 DPF(B)1.8C 1.80 0.07 2.93 10.3 5.60 19.7 2.30 8.1 2.08 7.3 3.01 10.6 3.44 12.1 DPF(B)2.0C 2.00 0.08 3.58 12.6 6.85 24.1 2.79 9.8 2.53 8.9 3.67 12.9 4.21 14.8 DPF(B)2.2C 2.20 0.09 4.32 15.2 8.22 28.9 3.36 11.8 3.04 10.7 4.44 15.6 5.06 17.8 DPF(B)2.4C 2.40 0.09 5.12 18.0 9.81 34.5 4.01 14.1 3.61 12.7 5.26 18.5 6.03 21.2 DPF(B)2.8C 2.80 0.11 6.99 24.6 13.39 47.1 5.46 19.2 4.92 17.3 7.17 25.2 8.22 28.9 DPF(B)3.0C 3.00 0.12 7.62 26.8 14.59 51.3 5.97 21.0 5.37 18.9 7.82 27.5 8.96 31.5 DPF(B)3.2C 3.20 0.13 8.22 28.9 15.70 55.2 6.43 22.6 5.77 20.3 8.42 29.6 9.64 33.9 The rated capacity is based on: 1. Full-Open; 2. Condensing Temperature Tc=38 C ; 3. Evaporating Temperature Te=5 C ; 4. Superheat Degree ΔTsh=0K; 5. Subcooling Degree ΔTsc=0K Note: For full list of model variants and selection please see our selection table Flow Rate Flow Type 1 Flow Type 2 Test Condition: 0.1mpa / 15psi

Style and Dimensions DPF(B) Model Φ1.3 to Φ2.4 Φ2.8 to Φ3.2 A B C D Style mm inch mm inch mm inch mm inch A 35 1.38 30 1.18 77 3.03 6.35 1/4 B 38 1.5 38 1.5 80 3.15 A 35 1.38 36 1.42 77 3.03 7.94 5/16 B 47 1.85 50 1.97 89 3.5 Coil Model Code NO. Valve Model Wire Length mm inch Wire Number Connector DPFX07-001 317101005300 Φ1.3 to Φ2.4 600 23.6 5 wires XHP-5 DPFX07-002 317101005400 Φ1.3 to Φ2.4 900 35.4 6 wires XHP-6 DPFX07-046 317109000100 Φ2.8 to Φ3.2 600 23.6 5 wires XHP-5 DPFX07-043 317109000200 Φ2.8 to Φ3.2 900 35.4 6 wires XHP-6

4-WAY REVERSING VALVE DSF/DSF(S) SERIES Application DSF/DSF(S) series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners. The valve allows the system to switch between cooling mode and heating mode by changing the flow path of refrigerant Features Specifications Thermoset material molded electromagnetic coil, better water resistance, greater electric strength and reliable insulation Less temperature rise, lower noise and higher vibration resistance Better sealing performance, higher efficiency and lighter weight Applicable refrigerants such as: R22, R32, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 70 C / -22 to 158 F Relative humidity: 0 to 95% RH Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Approvals: PED, LVD, VDE, TUV and UL Coil Parameters Model Code No. Rated Voltage Frequency Rated Power Temperature Rise of Rated Voltage Max. Working Temperature Insulation Class Enclosure Connection Type Supply Length V Hz W K C / F mm inch DXQ-242-ND 244409024208 AC24 50/60 7.5 < 80 Spade - - DXQ-451 244409045100 AC100 50/60 7.5 < 80 500 19.7 DXQ-423 244409042300 AC200 50/60 7.5 < 80 AC 420 16.5 DXQ-670 244409067000 AC208-240 50/60 7.5 < 80 1200 47.2 DXQ-822 244409082211 AC220-240 50/60 7.5 < 80 130 C / 266 F B IP54 1000 39.4 Wire DXQ-339 244409033900 DC35-9 < 80 DC 1085 42.7 DXQ-717 244409071702 AC100 50/60 18 < 75 420 16.5 DXQ-417 244409041702 AC200 50/60 18 < 75 Bi-stable Coil 400 15.7 DXQ-500 244409050000 DC15-12.5 < 65 250 9.8

Coil Styles Note: Please check our website for dimension details

Nominal Capacity Capacity Pressure Drop P [bar] Model R134a R404A R407C R410A Cond.1 Cond. 2 Cond. 1 Cond. 2 Cond. 1 Cond. 2 Cond. 1 Cond. 2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 0.1 0.2 kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw DSF-4 3.2 4.6 3.0 4.3 4.0 5.6 3.5 4.9 3.7 5.3 3.4 4.9 4.8 6.7 4.3 6.1 DSF-9 6.2 8.8 5.8 8.2 7.6 10.8 6.6 9.4 7.1 10.1 6.6 9.3 9.1 12.9 8.3 11.7 DSF-9B 6.2 8.8 5.8 8.2 7.6 10.8 6.6 9.4 7.1 10.1 6.6 9.3 9.1 12.9 8.3 11.7 DSF-9C 6.2 8.8 5.8 8.2 7.6 10.8 6.6 9.4 7.1 10.1 6.6 9.3 9.1 12.9 8.3 11.7 DSF-9E 6.2 8.8 5.8 8.2 7.6 10.8 6.6 9.4 7.1 10.1 6.6 9.3 9.1 12.9 8.3 11.7 DSF-11 8.0 11.3 7.4 10.5 9.8 13.8 8.5 12.1 9.1 12.9 8.4 11.9 11.7 16.5 10.6 15.0 DSF-11B 8.0 11.3 7.4 10.5 9.8 13.8 8.5 12.1 9.1 12.9 8.4 11.9 11.7 16.5 10.6 15.0 DSF-11E 8.0 11.3 7.4 10.5 9.8 13.8 8.5 12.1 9.1 12.9 8.4 11.9 11.7 16.5 10.6 15.0 DSF-11I 8.0 11.3 7.4 10.5 9.8 13.8 8.5 12.1 9.1 12.9 8.4 11.9 11.7 16.5 10.6 15.0 DSF-20 14.9 21.1 13.9 19.6 18.4 26.0 16.0 22.6 17.1 24.2 15.8 22.4 21.9 31.0 19.9 28.1 DSF-34D 25.1 35.5 23.3 32.9 30.8 43.6 26.9 38.0 28.8 40.7 26.6 38.0 36.7 52.0 33.4 47.2 DSF-34H 25.1 35.5 23.3 32.9 30.8 43.6 26.9 38.0 28.8 40.7 26.6 38.0 36.7 52.0 33.4 47.2 DSF-38 37.6 53.1 34.9 49.3 46.1 65.2 40.2 56.9 43.1 60.9 39.8 56.9 55.0 77.8 50.0 70.7 DSF-50 41.4 58.5 38.4 54.4 50.8 71.9 44.3 62.7 47.5 67.1 43.8 62.7 60.6 85.8 55.1 77.9 DSF-70 49.7 70.2 46.1 65.2 61.0 86.3 53.2 75.2 57.0 80.6 52.6 75.2 72.8 102.9 66.1 93.5 DSF-70B 49.7 70.2 46.1 65.2 61.0 86.3 53.2 75.2 57.0 80.6 52.6 75.2 72.8 102.9 66.1 93.5 DSF-105 81.4 115.1 75.6 106.9 100.0 141.4 87.2 123.3 93.4 132.0 86.2 123.3 119.3 168.7 108.4 153.3 DSF-105D 81.4 115.1 75.6 106.9 100.0 141.4 87.2 123.3 93.4 132.0 86.2 123.3 119.3 168.7 108.4 153.3 DSF-140 110.4 156.2 102.6 145.1 135.7 191.9 118.3 167.3 126.7 179.2 117.0 167.3 161.8 228.9 147.1 208.0 DSF-180 141.1 199.6 131.1 185.4 173.4 245.2 151.2 213.8 161.9 229.0 149.5 213.8 206.8 292.5 187.9 265.8 DSF-210 160.7 227.3 149.3 211.1 197.4 279.2 172.1 243.4 184.4 260.7 170.2 243.4 235.5 333.1 214.0 302.7 Note: 1. Cond.1: Tc=38 C, Te=5 C, ΔT sh =5K, ΔT sc =0K; 2. Cond.2: Tc=54.4 C, Te=7.2 C, ΔT sh =5K, ΔT sc =5K. Valve Body Technical Parameters Stainless Steel DSF(S) Series Model Port Size Kv Flow Factor Cv Flow Factor Connections ODF OPD ØD ØE/S/C Max Min mm inch m3/h gpm mm inch mm inch mpa psi mpa psi DSF(S)-4 8.0 0.31 1.7 1.97 7.94 5/16 9.52 3/8 3.1 (R410A, R32) 2.45 (R134a, R407C, R404A) 450 (R410A, R32) 355 (R134a, R407C, R404A) 0.25 36.25 DSF(S)-9 11.1 0.44 3.1 3.58 9.52 3/8 12.70 1/2 0.3 43.5

Brass DSF Series Model Port Size Kv Flow Factor Cv Flow Factor Connections ODF OPD ØD ØE/S/C Max Min mm inch m3/h gpm mm inch mm inch mpa psi mpa psi DSF-4 8.0 0.31 1.7 1.97 8.1 5/16 9.6 3/8 DSF-9 11.1 0.44 3.0 3.47 9.6 3/8 12.80 1/2 DSF-9B 11.1 0.44 3.0 3.47 9.6 3/8 16.10 5/8 DSF-9C 11.1 0.44 3.0 3.47 9.6 3/8 16.10 5/8 DSF-9E 11.1 0.44 3.0 3.47 9.6 3/8 12.80 1/2 DSF-11 11.5 0.45 3.0 3.47 12.80 1/2 16.10 5/8 DSF-11B 11.5 0.45 3.0 3.47 12.80 1/2 16.10 5/8 DSF-11E 11.5 0.45 3.0 3.47 9.60 3/8 16.20 5/8 DSF-11I 11.5 0.45 3.0 3.47 12.80 1/2 19.20 3/4 DSF-20 15.5 0.61 7.2 8.32 12.80 1/2 19.20 3/4 DSF-34D 19.2 0.76 12.3 14.22 22.40 7/8 29.10 9/8 DSF-34H 19.2 0.76 12.3 14.22 19.20 3/4 22.30 7/8 DSF-38 23.0 0.91 13.4 15.49 22.50 7/8 28.60 9/8 DSF-50 24.0 0.94 13.9 16.07 22.50 7/8 28.60 9/8 DSF-70 26.0 1.02 28.7 33.18 25.60 1 32 5/4 DSF-70B 26.0 1.02 28.7 33.18 28.30 9/8 35.30 11/8 DSF-105 34.5 1.36 39.1 45.20 31.80 5/4 38.10 3/2 DSF-105D 34.5 1.36 39.1 45.20 28.88 9/8 35.12 11/8 DSF-140 41.0 1.61 58.5 67.63 38.10 3/2 45 7/4 DSF-180 46.4 1.83 70.4 81.38 38.10 3/2 54.20 17/8 DSF-210 50.0 1.97 80.2 92.71 50 2 66.96 21/8 3.1 (R410A, R32) 2.45 (R134a, R407C, R404A) 450 (R410A, R32) 355 (R134a, R407C, R404A) 0.25 36.25 0.3 43.5 Styles

Note: Please check our website for dimension details

LARGE CAPACITY 4-WAY REVERSING VALVE DRVB SERIES Application DRVB series switches the mode between cooling and heating by changing the refrigerant flow path. The flow path inside the DRVB is controlled by a pilot 4-way valve, which alters the pressure difference between two side seal chambers of the valve body Features Specifications X-cross flow path design ensures high capacity, short flow path and low pressure drop A small capacity 4-way reversing valve as a pilot valve ensures stability and reliability Flange construction makes assembly and maintenance easy Built-in self-lubricating bushing provides over 100,000 cycles of shifting service life Special material seal ring allow the valve to be used with all common refrigerants Applicable refrigerants such as: R22, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 130 C / -22 to 266 F Ambient temp. range: -20 to 55 C / -4 to 131 F Relative humidity: 0 to 95% RH Max. working pressure: 4.2 mpa / 609 psi Max. working pressure differential: 3.1 mpa / 450 psi Min. working pressure differential: 0.3 to 0.4 mpa / 44 to 58 psi Approvals: declaration according to PED or LVD Coil Specifications Ambient temp. range: -30 to 55 C / -22 to 131 F Allowable voltage tolerance: 85% to 110% Standard coil: 220V AC Relative humidity: 0 to 95% RH

Nominal Capacity Model R22 R134a R407C R410A TR kw TR kw TR kw TR kw DRVB115* 55.7 196 42.4 149 53.5 188 64.0 225 DRVB118* 75.1 264 56.9 200 71.9 253 86.2 303 DRVB121* 104.1 366 79.0 278 99.8 351 119.4 420 DRVB125* 135.3 476 102.9 362 129.9 457 155.5 547 DRVB130* 216.7 762 164.9 580 207.6 730 248.8 875 The rated capacity is based on: 1. Condensing Temperature Tc=50 C; 2. Liquid Temperature Before Expansion Valve TI=48 C ; 3. Evaporating Temperature Te=2 C ; 4. Suction Gas Superheat Degree T sh =6K; 5. Low Pressure Drop P=0.015 MPa. Note: For full list of model variants and capacities please see our model capacity chart Styles Note: Please check our website for dimension details

BALL VALVE FQ SERIES Application FQ series Ball Valve is applicable for commercial air conditioner, freezing or deep-freezing equipment or other refrigeration circuits. The valve opens and closes inner flow path through the valve stem. Access port variant can also be supplied Features Specifications Straightway type, low pressure drop, cost-effective Valve body and valve seat with welded structure increasing reliability Modified polymer to ensure fitting tightness Small installation space required Supplied with/without access port, with holes for panel mounting Applicable refrigerants such as: R22, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -20 to 60 C / -4 to 140 F Relative humidity: 0 to 95% RH Max. working pressure: 4.5 mpa / 653 psi Approvals: UL, declaration according to PED Valve Body Technical Parameters Without Access Port ODF Connection Flow Rate (1) Model Port Size Port Size Code NO. [inch] [mm] Code NO. m3/h gpm FQ 06 1/4 380004011000 6 380004011200 0.89 1.03 FQ 10 3/8 380008011000 10 380008011200 1.96 2.27 FQ 12 1/2 380010011000 12 380010011200 5.68 6.57 FQ 16 5/8 380013011000 16 380013011000 10.4 12.02 FQ 19 3/4 380015011000 19 380015011000 15.7 18.15 FQ 22 7/8 380020011000 22 380020011000 23.6 27.28 FQ 28 9/8 380025011000 28 380025011200 43.8 50.63 FQ 35 11/8 380032011000 35 380032011000 76.8 88.78 FQ 42 13/8 380040011000 42 380040011200 98.5 113.87 FQ 54 17/8 380050011000 54 380050011000 210.3 243.11 FQ 67 21/8 380065011000 - - 346.6 400.67 FQ 79 25/8 380075011000 - - 477.6 552.11 (1) CFD (computational fluid dynamics) calculated values.

With Access Port Model Port Size [inch] Code NO. ODF Connection Flow Rate (1) Port Size [mm] Code NO. m3/h gpm FQ 10 3/8 380008011600 10 380008011800 1.96 2.27 FQ 12 1/2 380010011600 12 380010011800 5.3 6.13 FQ 16 5/8 380013011600 16 380013011600 10.4 12.02 FQ 19 3/4 380015011600 19 380015011600 15.7 18.15 FQ 22 7/8 380020011600 22 380020011600 23.6 27.28 FQ 28 9/8 380025011600 28 380025011800 43.8 50.63 FQ 35 11/8 380032011600 35 380032011600 76.8 88.78 FQ 42 13/8 380040011600 42 380040011600 98.5 113.87 FQ 54 17/8 380050011600 54 380050011800 210.3 243.11 FQ 67 21/8 380065011600 - - 346.6 400.67 FQ 79 25/8 380075011600 - - 477.6 552.11 (1) CFD (computational fluid dynamics) calculated values. Dimensions Note: Please check our website for dimension details

CHECK VALVE FDM SERIES Application FDM series check valves use magnetic diaphragm design with metal sealing structure, built-in guiding device, and self-closing structure. The valve can be installed in any angle Features Specifications Self-closing structure allows for any installation angle Low internal leakage Applicable refrigerants such as: R22, R134a, R404a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Approvals: UL, declaration according to PED Valve Body Technical Parameters

Model FDM 0702 FDM 0703 FDM 0904 FDM 0905 FDM 0906 FDM 0907 FDM 1107 FDM 1406 FDM 1409 FDM 1709 FDM 2111 FDM 2113 FDM 2817 FDM 3321 FDM 3325 Code NO. Connection Size C L L1 Max. Working Pressure Pressure Drop Across Valve P Flow Rate inch mm inch mm inch mm inch mpa psi mpa psi m3/h gpm 260510000101 1/4 22.3 0.9 102 4.0 10 0.4 5 725 0.01 1 0.7 0.81 260511000101 3/8 22.3 0.9 100 3.9 10 0.4 5 725 0.01 1 0.8 0.92 260512000101 1/2 28.5 1.1 127 5.0 14 0.6 5 725 0.01 1 2.6 3.01 260513000101 5/8 28.5 1.1 127 5.0 15.5 0.6 5 725 0.01 1 3.1 3.58 260514000101 3/4 28.5 1.1 127 5.0 14 0.6 4.5 653 0.01 1 3.3 3.81 260523000101 7/8 28.5 1.1 127 5.0 18 0.7 4.5 653 0.01 1 3.4 3.93 260515000101 7/8 35 1.4 178 7.0 15 0.6 4.5 653 0.01 1 3.9 4.51 260524000101 3/4 41 1.6 178 7.0 18 0.7 4.5 653 0.02 3 6.8 7.86 260516000101 9/8 41 1.6 206 8.1 18 0.7 4.5 653 0.02 3 10.4 12.02 260517000101 9/8 54 2.1 213 8.4 25.5 1.0 4.5 653 0.02 3 13.2 15.26 260518000101 11/8 67 2.6 238 9.4 26 1.0 3.5 508 0.02 3 20.4 23.58 260519000101 13/8 80 3.1 267 10.5 28 1.1 3.5 508 0.03 4 20.7 23.93 260520000101 17/8 92 3.6 305 12.0 34 1.3 3.5 508 0.05 7 33.2 38.38 260521000101 21/8 105 4.1 330 13.0 38 1.5 3.5 508 0.05 7 61.4 70.98 260522000101 25/8 105 4.1 330 13.0 38 1.5 3.5 508 0.05 7 - -

CHECK VALVE FD SERIES Application FD series check valve is used in residential air conditioning system to ensure one-way flow of liquid Features Specifications Integrated structure reduces leakage risk Very low pressure drop Applicable refrigerants such as: R134a, R404a, R407C, R410A, and R290 Medium temp range (C & F): -30 to 120 C / -22 to 248 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Approvals: UL, declaration according to PED Valve Body Technical Parameters Model Code NO. Style Dw L D Dm H d dn h Min. OPD Kv Cv mm mm mm mm mm mm mm mm mpa psi m3/h gpm FD-0576 260300057600 A 9.52 100 6.2 2.7 8 3 2.7 8 0.47 0.54 FD-0500 260300050000 A 11.5 100 6.2 2.7 8.5 3.4 2.7 11 0.51 0.59 FD- 0070/A 260300007000 A 12 120 8.1 3.1 10 8.1 3.1 10 0.56 0.65 FD-0230 260300023000 B 12.7 100 9.6 - - 9.6 - - 0.01 1.5 0.56 0.65 FD-0025 260300002500 B 16 100 11.7 - - 12.2 - - 0.86 0.99 FD-0251 260300025100 C 19 93 9.7 3 3-9.7 3 3-1.54 1.78 FD-0248 260300024800 B 22 140 16.2 - - 16.2 - - 1.54 1.78

Styles

CHARGE VALVE FJT SERIES Application Charge valves are mainly installed in air conditioning and refrigeration systems. They are used as service valves for circuit evacuation to vacuum and for refrigerant injection Features Simple structure, convenient to use Combination of soft seal and hard seal ensures airtightness Specifications Applicable refrigerants such as: R32, R134a, R404a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 70 C / -22 to 158 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Approvals: UL, declaration according to PED

Dimensions Model Code NO. Connections FJT-8881-DG4 280004888100 6.35 1/4 FJT-8883-DG4 280004888300 6.35 1/4 Dimensions Solder ODF φd Flare A B φc E mm inch inch mm inch mm inch mm inch 1/2-20 UNF 7/16-20 UNF Applicable Refrigerant 60 2.36 8.5 0.33 3 0.12 R32, R410A 60 2.36 8.5 0.33 3 0.12 R407C, R134a, R404A Model FJT-8884- DG4 FJT-8886- DG4 Code NO. Connections 280004888400 6.5 1/4 280004888600 6.5 1/4 Dimensions Solder ODF φd Flare A B D mm inch inch mm inch mm inch 1/2-20 UNF 7/16-20 UNF Applicable Refrigerant 60 2.36 8 0.31 R32, R410A 60 2.36 8 0.31 R407C, R134a, R404A

SERVICE VALVE FJ SERIES Application The FJ service valves main functions are: 1) connect air condition indoor unit and outdoor unit; 2) open or close the refrigerant system; 3) vacuumize or charge the refrigerant into the system Features Specifications Simple structure, convenient to use Combination of soft seal and hard seal ensures airtightness Applicable refrigerants such as: R32, R134a, R404a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 70 C / -22 to 158 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Approvals: UL, declaration according to PED Nominal Capacity Model Code NO. Capacity TR kw FJ-8888-DG4 280004888800 0.45-1.17 1.6-4.1 FJ-8888-DG8 280008888800 0.6-2.27 2.1-8 FJ-8888-DG10 280010888800 1.76-4.58 6.2-16.1 FJ-8888-DG13 280013888800 2.79-7.22 9.8-25.4 FJ-8888-DG16 280016888800 4.32-11.15 15.2-39.2 FJ-8887-DG4 280004888700 0.45-1.17 1.6-4.1 FJ-8887-DG8 280008888700 0.6-2.27 2.1-8 FJ-8887-DG10 280010888700 1.76-4.58 6.2-16.1 FJ-8887-DG13 280013888700 2.79-7.22 9.8-25.4 FJ-8887-DG16 280016888700 4.32-11.15 15.2-39.2 Applicable Refrigerant R410A, R32 R407C, R134a, R404A

Dimensions Note: Please check our website for dimension details

SERVICE VALVE FJB SERIES Application The FJB series service valves are used in VRF air conditioning system. The main functions are: 1) connect air condition indoor unit and outdoor unit; 2) open or close the refrigerant system; 3) vacuumize or charge the refrigerant into the system Features Specifications Double sealing design ensures low leakage Good sealing performance and long lifetime Reliable design Applicable refrigerants such as: R22, R134a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -20 to 60 C / -4 to 140 F Max. working pressure: 4.2 mpa / 609 psi Approvals: declaration according to PED

Styles Dimensions Note: Please check our website for dimension details