Early Warning Solutions for Airborne Toxic Industrial Chemicals René Braun Research and Development Remote Sensing Rene.Braun@bruker.com
Early Warning Solutions for Airborne Toxic Industrial Chemicals REMOTE SENSING COVERING LARGE AREAS ANALYTICAL CERTAINTY FAST RESPONSE 24/7/365 PERMANENT MONITORING DAY AND NIGHT OPERATION
Bruker Early Warning Corporation Solutions Groups for Airborne & Divisions Toxic Industrial Chemicals Bruker BioSpin Group Bruker CALID Group Bruker NANO Group Bruker EST (BEST) Magnetic Resonance Spectroscopy (MRS) Mass Spectrometry (Daltonics) REMOTE SENSING COVERING LARGE AREAS ANALYTICAL CERTAINTY FAST RESPONSE Bruker Nano Surface Supercon wire and devices Preclinical Imaging (PCI) Infrared & Raman Spectroscopy (Optics) X-ray Analysis 24/7/365 PERMANENT MONITORING DAY AND RAPID NIGHT SITUATION OPERATION OVERVIEW Applied, Industrial and Clinical (AIC) CBRNE (Detection) CALID = Chemical, Applied Markets, Life Science, In-Vitro Diagnostics, Detection Bruker Nano Analytics BEST: Bruker Energy and Supercon Technologies
Bruker Optics Bruker Optics 600+ employees worldwide Headquarters Production centers Bruker Optics distribution and service offices Numerous further representatives worldwide
Bruker Permanent Optics Monitoring Imaging Remote Sensing COMMON SECURITY MEASURES Detector networks Propagation simulation software Local gas sensors or pipeline monitoring systems FTIR FT NIR RAMAN Gas Analysis R&D Solution Remote Sensing
Permanent Monitoring Imaging Remote Sensing WATCHTOWER Identification from long distances Providing situation overview Intuitive visualization of localization and propagation direction
SIGIS 2 Scanning Infrared Gas Imaging System Austria Belgium Czechia Danmark (2 Systems) Germany (10 Systems) Italy Portugal Brasil (7 Systems) China (3 Systems) Great Britain Irak (3 Systems) Singapore (3 Systems) South-Korea (6 Systems) 19. November 2017
SIGIS 2 Scanning Infrared Gas Imaging System Scanner-Head GPS Video-Camera IR-Camera Spectrometer Unit Telescope 19. November 2017
SIGIS 2 Scanning Infrared Gas Imaging System
SIGIS 2 Scanning Infrared Gas Imaging System 360
SIGIS 2 Scanning Infrared Gas Imaging System PASSIVE MEASUREMENT TECHNIQUE
SIGIS 2 Scanning Infrared Gas Imaging System
SIGIS 2 Scanning Infrared Gas Imaging System Ammonia Acetone Acroleine Acrylonitrile Aniline Benzene Hydrogen Cyanide AC Chlorobenzene Chloroform Ethanol Formaldehyde n-hexane Hydrazine Methane Methanol Methyl bromide Phosgene CG Phosphine Nitric acid Sulfur dioxide Carbon disulfide Hydrogen sulfide Nitrogen dioxide Styrene Tetrachloroethene NH 3 Atmospheric gases: Componsation: Target Gas Identification Water, Ozone, Methane, Carbon Dioxide, > 420 Compounds
24/7 Monitoring @ YARA Rostock Distance: 5 km Event Yara Rostock: Production Evening and 7/12/2012 Storage site for ammonium nitrate outside temperature around -5 C SIGIS2 monitoring (23 F) critical infrastructure since 2014 light wind from south-east direction Strong ammonia smell reported from Warnemunde Reaction Operators quickly identified origin Accidental release of ammonia by lifting safety valve on one of the atmospheric tanks Release stopped by starting extra cooling capacity, lowering the pressure in the tanks Consequence No one injured Local media attention
SIGIS 2 Permanent Monitoring @ YARA Rostock
Identification of Ammonia Screenshot WARNING: NH 3 IDENTIFIED
Real-Time Monitoring PERMANENT MONITORING GAS IDENTIFICATION SOURCE LOCALIZATION
Real-Time Monitoring Production Site in Urban Areas
Areas of Interest STORAGE PIPELINE STORAGE LOADING STATION PRODUCTION
Monitoring Critical Infrastructure 4/7/365 STORAGE FACILITIES VALVES PIPELINES LOADING AREAS ETC.
Monitoring Critical Infrastructure Automatic Programmable Sector Scan
Monitoring Critical Infrastructure Automatic Programmable Sector Scan
Rapid Monitoring SEVESO areas 24/7/365
Pipeline Monitoring 27 January 2011 24
Fast Scanning Pattern 16 SCANS PER s
Fast Scanning Pattern 1 km 60
Fast Scanning Pattern 1 km SCAN-TIME: 4.5 s
Fast Scanning Pattern SCAN-TIME: 4.5 s FOR A STACK OF PIPELINES
Measurement Example Detection of Leak in Ammonia Pipeline GAS LEAK IDENTIFIED AS AMMONIA
3D-Leak Detection 24/7/365
3D-Leak Detection Control Room Interface Autonomous SIGIS2 Live-View 3D Control Room
Localization Automatic Data Export to Google Earth
Rapid Monitoring SEVESO areas 24/7/365
HI 90 Realtime Identification Ethylen SO 2
HI 90 Realtime Identification Acetone Ethanol
HI 90 Automatic Source Localization Acetone
Grand Perspective TECHNIQUE DESIGN VITAL INFORMATION FOR CONTAINMENT STRATEGY CONTRIBUTION TO HEALTH & SAFETY ENVIRONMENTAL PROTECTION PROMOTING SAFETY PROFILE
Bruker Scientific Israel LTD David Zaks M.Sc. FT-IR, Raman, FT-NIR, TD-NMR Sales & Applications Bruker Scientific Israel LTD 5 Golda Me'ir st., Science Park Ness Ziona, Israel Phone: +972 8 9477705 Mobile: +972 54 6698655 David.Zaks@bruker.com 19. November 2017 38 Copyright Bruker Corporation. All rights reserved