Vescom B.V. Sint Jozefstraat 2 73 AV Deurne Nederland Your tice of 3--217 Your reference Date 18-7-217 Analysis Report 17.262.21 Required tests : IMO - 21 FTP Code Annex 1 - Fire test procedures - Part 7 Fire Test Procedures - Test for vertically supported textiles and films Identification number T17996 Information given by the client Long-837 Date of receipt 3--217 Petra Wittevrongel Order responsible This report may be reproduced, as long as it is presented in its entire form, without written permission of Centexbel. The results of the analysis cover the received samples. Centexbel is t responsible for the representativeness of the samples. In assessing compliance with the specifications, we did t take into account the uncertainty on the test results. CENTEXBEL textile competence centre www.centexbel.be www.vkc.be Inrichting erkend bij toepassing van de besluitwet van 3-1-1947 Établissement reconnu par application de l'arrêté-loi du 3-1-1947 GENT Techlogiepark 7 BE-92 Zwijnaarde, Belgium phone +32 9 22 41 1 fax +32 9 22 49 gent@centexbel.be GRÂCE-HOLLOGNE Rue du Travail BE-446 Grâce-Hollogne, Belgium phone +32 4 296 82 g-h@centexbel.be KORTRIJK Etienne Sabbelaan 49 BE-8 Kortrijk, Belgium phone +32 6 281828 fax +32 6 28183 info@vkc.be VAT BE 49.218.289 IBAN BE44 21 4729 BIC GEBABEBB
Analysis Report 17.262.21 Date 18-7-217 Page 2/ Reference: T17996 - Long-837 IMO curtains Information given by the client Type of material Fabric Composition Structure Number of threads - warp Number of threads - weft Yarn count - warp Yarn count - weft Weight per unit area Inherently FR treated Curtain / drape 1% PES (Trevira CS) Weave 27 Nm 4/1 CS Nm 4/3 CS + Nm 1/2 CS + Nm 4/2 CS 88 g/m² yes
Analysis Report 17.262.21 Date 18-7-217 Page 3/ Reference: T17996 - Long-837 Fire Test Procedures - Test for vertically supported textiles and films Date of ending the test Standard used Deviation from the standard Conditioning 3-6-217 IMO - 21 FTP Code Annex 1 - Fire test procedures - Part 7-2 C, relative humidity 6% The test results relate to the behaviour of the test specimens of a product under the particular conditions of the test: they are t intended to be the sole criterion for assessing the potential fire hazard of the product in use. The test specimens have t been cleaned r submitted to an accelerated ageing procedure. Weight (g/m²) - 1 83 Determination of the test conditions. Length 31 Surface 1 29 1 Edge 1 3 No sustained ignition : testing continued under conditions showing the greatest damaged length.
Analysis Report 17.262.21 Date 18-7-217 Page 4/ 32 Surface 1 36 4 Edge 1 No sustained ignition : testing continued under conditions showing the greatest damaged length. Worst testing conditions Length Edge - flame application time 1 s 1 3 2 9 3 7 4 6 47 Average Edge - flame application time 1 s 1 2 4 3 4 39 39 Average 47 Criteria for curtains and drapes
Analysis Report 17.262.21 Date 18-7-217 Page / Criteria for curtains and drapes 1. Afterflame time s for any specimen tested with face ignition. 2. No flame propagation to the edges for any specimen tested with face ignition.. 3. No ignition of the for any specimen. 4. Average char length 1 mm in any of the batches tested with face or edge ignition.. No occurance of a surface flash more than 1 mm from the point of ignition. Remark: If the test for length and/or width is carried out with edge ignition, the results obtained through the edge application are considered for the purposes of the criteria 1 and 2. The fabric passes the proposed criteria for curtains and drapes. Performed under accreditation in the fire lab under the responsibility of Philippe Van Acker