GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Similar documents
July 14, 1999 DF C-100.

June 10, 2002 DF C S2424

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100C. Emergency Command Center

ECC-50/100(E) Emergency Command Center

PN: 51604:A ECN Voice Evacuation Control Panel FIRE COMMAND 25/50X & FIRE COMMAND 25/50XE. Document # /17/02 Rev.

SP40S-D. Kingfisher Company, inc. Features: Description:

SAFEPATH Mass Notification System (SPMNS)

Autonomous control unit

SAFEPATH DoD facility communications system & expansion options

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

AL600ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

LifeAlarm Fire Alarm Controls

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

SAFEPATH SAFEPATH. Emergency communications system

30.45 Electric Release PDRP-2001

Booster Power Supply Manual

Specification/ Data Sheet

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

FireNET Plus Wiring Instructions

Addressable Fire Alarm Control Panel

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

E3 Series Broadband System

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Remote NAC Power Supply D7038

Pompano Pet Lodge 930 Northwest 31 st Avenue Pompano Beach, FL 33069

TrueAlert Addressable Notification Appliances

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

TECHNICAL DATA OBSOLETE

TrueAlert Addressable Notification Appliances

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

1. POWERPATH Operation

TrueAlert Addressable Notification

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Emergency Command Center ECC-50/100 ECC-50/100E. Instruction Manual. Document LS FL-E 5/3/2016 Rev: G P/N LS FL-E:G ECN

Rev. A. Technical Manuals Online! -

TrueAlert Notification Appliances

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

good things in small packages

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

ELECTRONIC SOUNDER STROBE Model : AVD-C407

TrueAlert Addressable Notification Appliances

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Installation Guide for models:

Installation Guide for models:

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

LifeAlarm Fire Alarm Control Panels

Addressable NAC Output Module D327A

Bosch EVAX System - High-rise Applications

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Release Control Fire Alarm Systems

Fire Control/Communicator

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Conventional Releasing Control Panel

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Fire Alarm Testing and Inspection Report

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

AND ARCHITECT SPECIFICATIONS

PSN-1000 & PSN 1000(E) Installation Manual

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

AL600ULX Series. Power Supply/Charger. Installation Guide

Commercial and Light Industrial Fire Alarm Control Panel

RELEASE DEVICE CONTROLS

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Series. Access Power Controllers. Installation Guide

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

SMALL SCALE SOLUTIONS

SP-1000X. Panic Device Power Controller Installation Guide. Rev

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Mircom FX /01/16

TrueAlarm Fire Alarm Controls

Transcription:

GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt, 25 VRMS audio amplifier, commercial-grade emergency communications microphone and alert tone generator, standard. Additionally, an integral digital message generator provides a factory prerecorded voice announcement and field record and playback capability. The VEC 25/50 is suitable for use as an adjunct to most UL listed Fire Alarm Control Panels (FACP) in slave applications or as a stand-alone system utilizing a built-in power supply/battery charger. Options include a 25 Watt, 25 VRMS audio amplifier for system expansion to 50 Watts (providing dual 25 Watt speaker circuits) or as a secondary, backup amplifier in jurisdictions requiring such. A 70.7 VRMS converter is also available for independently converting amplifiers to meet retrofit needs. A host of field-programming options, including dual-message capability (fire, weather, non-fire, multi-language), makes the VEC 25/50 the most versatile voice evacuation system available. Suitable applications include, but are not limited to: schools, auditoriums, dormitories, theaters, restaurants, places of worship, motels/hotels, office buildings, factories, etc. STANDARD FEATURES Integral 25 Watt, 25 VRMS audio amplifier with single Class A or Class B speaker circuit. Standard, commercial-grade emergency communications microphone. Integral Digital Message Generator with standard, factory prerecorded emergency evacuation message. Integral message generator includes 60 second capacity, with primary and secondary message capability (30 seconds each). Custom messages are field recordable without the addition of costly add-on modules utilizing microphone or audio input jack. Digital message may be field-selected for 1, 2, 4, 8 or infinite repeat. Built-in alert tone generators with steady, slow whoop, high/low or chime tone capability. Field-selectable lead-in/trailing tone selection. Alert tone selection(s) may be field-programmed to conform with ANSI S3.41 Audible Emergency Evacuation Signal (Temporal Pattern), per NFPA. July 19, 1999 VEC 25/50 Emergency Voice Evacuation Control S635 Section: Emergency Voice Evacuation C-50 PATENT PENDING California MEA State Fire 177-97-E Marshal 6911-0028:191 CS118 Dual-optically-isolated, trigger input circuits are independently field-programmable for activation by polarity reversal (host FACP NAC) or dry contact-closure. Powered from local 120 VAC (batteries required) or by removing a built-in power supply module (VEC-PSM) powered by host FACP auxiliary 24 VDC output. Two-position switch provides ALL-CALL or Manual Evacuate functions. Integral diagnostic LEDs include: Power, System Trouble, ALARM, Microphone Trouble, Message Generator Trouble, Tone Generator Trouble, Amplifier Fault and others. For ease of service and maintenance, plug-in style terminal blocks are utilized for most field-wiring terminations. Independent Form-C trouble relay allows FACP to monitor voice system while in active (alarm) state. Integral piezo provides local audible indication for troubles. 5789cov.wmf This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 One Fire-Lite Place, Northford, Connecticut 06472 ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 Made in the U.S.A. DN-5789 Page 1 of 6

Fully supervised, including integral microphone, amplifier output, message generator, speaker wiring and tone generators, in Standby and Active states. Independent amplifier supervision: current limit, audio level, short circuit protection. All outputs fully power-limited to meet latest UL requirements. Current in-rush protection (limits current draw from external power supply during cold start). Auxiliary power output provides local power for addressable control modules when used to activate VEC. Unique amplifier design features high signal-to-noise ratio. Utilizes Surface Mount Technology. Compatible with ALL NOTIFIER Fire Alarm Control Panels, as well as other manufacturers'. Aesthetically pleasing design has similar look and feel to NOTIFIER's popular FACPs. Background music requires AHJ approval. OPTIONAL MODULES FC-AAM25 25 Watt, 25 VRMS audio amplifier module. Field-programmable for system expansion to 50 Watts (providing dual 25 Watt speaker circuits) or as a backup to the primary 25 Watt amplifier, where required. Provides single Class A or Class B speaker circuit. Utilizes plug-in style terminal blocks for ease of service and maintenance. Fully supervised and power-limited. Diagnostic LEDs include: yellow trouble LED (cable fault, 70 VRMS fault, amp fault) and green, amp functional LED. FC-PSM Power supply/battery charger module for stand-alone applications. Included with base model. Ground fault detection with diagnostic LED (yellow). Brownout detection with battery transfer. Battery trouble detect with diagnostic LED (yellow). Battery saver operation. Independent AC loss relay provides AC loss delay per UL, for independent monitoring by DACT (2 Amps at 24 VDC). AC power on LED (green). 17 AH battery charging capacity up to 7 AH may be utilized in VEC enclosure. 12 AH - 17 AH require NOTIFIER BB-17 battery box. Large, teeter-plate terminal blocks easily accept up to 12 AWG for power terminations. FC-XRM70 Converts 25 VRMS audio outputs to 70.7 VRMS for retrofit applications. Plugs directly on FC-AAM25 module(s), allowing independent conversion to 70.7 VRMS. FC-LPS Provides local digital message playback for user review of field-recorded custom messages. STANDARDS AND CODES The VEC 25/50 will comply with the following standards: NFPA 72-1993 National Fire Alarm Code NFPA 101-1994 Life Safety Code UL 864 Standard for Control Units for Fire Alarm Systems SPECIFICATIONS STAND-ALONE APPLICATIONS Primary (AC) Power - Stand-alone applications: 1.0 Amp max. @ 120 VAC, 50/60 Hz. Secondary Power (Battery) Charging Circuit: Supports lead acid batteries only. Float charge voltage: 27.6V. Maximum charge current: 800 ma. Maximum battery capacity: 17 AH (greater than 7 AH requires a separate battery box). SLAVE APPLICATIONS (remove FC-PSM module) Primary Power: 24 VDC (19.1-26.4) regulated, filtered, power-limited. Standby Current: 180 ma maximum @ 1 amplifier, 210 ma maximum @ 2 amplifiers. Alarm Current: 2.0 Amps DC maximum @ 1 amplifier, 4.0 Amps DC maximum @ 2 amplifiers. CAUTION: Ensure proper available current from host FACP auxiliary power output or power supply UL-listed for Fire Protective Signaling Service to support alarm current drain. Dual Command Input Circuits: Trigger input Voltage: 10.5 to 29 VDC (UL tested range -15%, +10%). Note: When programmed for reverse-polarity activation. Trouble Contact Rating: 2.0 Amps at 30 VDC (resistive), 0.06 Amps @125 VAC resistive. Auxiliary Power Output: Specific application power - 60 ma maximum. CABINET SPECIFICATIONS Door: 18.65" high x 15.65" wide x 1.08" deep. Backbox: 18.5" high x 15.5" wide x 4.25" deep. CONTROLS AND INDICATORS LED INDICATORS 1. Power On (green). 2. ALARM (red). 3. System Trouble (yellow). 4. Microphone Trouble (yellow). 5. Message Generator Trouble (yellow). 6. Tone Generator Trouble (yellow). 7. Record (green). 8. Playback (green). SWITCH CONTROLS 1. Record. 2. Silence. 3. Playback. 4. Manual Evacuate. 5. All Call. Page 2 of 6 DN-5789

ORDERING INFORMATION VEC-25/50 25 Watt, 25 VRMS, stand-alone or slave Emergency Voice Evacuation Control, with integral microphone, digital message generator and single Class A or Class B speaker circuit. FC-AAM25 Optional 25 Watt, 25 VRMS Audio Amplifier Module with single Class A or Class B speaker circuit. FC-PSM Replacement 120 VAC, 60 Hz Power Supply/ Battery Charger Module for stand-alone applications (included with base model). FC-XRM70 Optional 70.7 VRMS Converter Module (one required per amplifier). Consult factory for availability. FC-LPS Optional Local Playback Speaker. VEC-TR Trim Ring, Semi-Flush Mounting. PS-1270 Battery, 12 volt, 7.0 AH (two required for stand-alone applications). PS-12120 Battery, 12 volt, 12.0 AH, (two required for stand-alone applications requires BB-17 Battery Box). PS-12170 Battery, 12 volt, 17.0 AH, (two required for stand-alone applications requires BB-17 Battery Box). BB-17 Battery Box, required to mount PS-12120 or PS-12170 batteries. SYSTEM CONFIGURATION Standard 25 Watt, 25 VRMS Audio Amplifier Optional Audio Amplifier Module 25 Watt, 25 VRMS (FC-AAM25) Standard Power Supply Module (FC-PSM) Standard MASTER COMMAND BOARD (FC-MCB) Optional 70.7 VRMS Transformer Module (FC-XRM70) INTEGRAL MICROPHONE (FC-Microphone for replacement) 51546bd.wmf Optional BATTERIES DN-5789 Page 3 of 6

APPLICATIONS EXAMPLES One Speaker Circuit One 60s Message 25 Watts A very basic application consists of one VEC 25/50 Master and one amplifier with a single speaker circuit. A second amplifier can be installed as a backup if desired. This configuration is suitable for small facilities requiring no more than 25 watts of output power. A single fire evacuation message will be generated during an alarm condition from the host FACP. In this application, the NAC from the host FACP is connected to CMD1. The CMD1 out terminals are then terminated with an EOL for a Style Y Notification Appliance Circuit (NAC) or the terminals are wired back to the host FACP for a Style Z NAC. S5 DIP switch 2 is set to OFF which causes the speaker circuit to be activated by the CMD1 input. S5 DIP switch 5 is set to OFF which causes CMD1 input to be activated by a reverse polarity condition. NOTE: VEC 25/50 may be configured for use as a manual evacuate system only, without need for FACP NAC or contact closure for activation (trigger). One Speaker Circuit One 60s Message 25 Watts 51546ap1.wmf Page 4 of 6 DN-5789

Two Speaker Circuits Two 30s Messages (Fire and Non-Fire) 50 Watts This application consists of one VEC 25/50 Master and two speaker circuits which requires installation of the optional second amplifier (FC-AAM25). This configuration is suitable for small facilities requiring no more than 50 watts of output power (providing dual 25-watt speaker circuits). A fire evacuation message (primary) will be generated over both speaker circuits during an alarm condition from the host FACP and an emergency (secondary) non-fire message (e.g., weather alert) can be manually generated over both circuits. In this application, the NAC from the host FACP is connected to CMD1. The CMD1 out terminals are then terminated with an EOL for a Style Y NAC or the terminals are wired back to the host FACP for a Style Z NAC. CMD2 is connected to a normally open contact which can be used to manually generate an emergency non-fire message (e.g., Tornado MFA). S5 DIP switch 2 is set to ON which causes transmission of the primary fire message over speaker circuits 1 and 2 upon activation of CMD1 and transmission of the secondary non-fire message over speaker circuits 1 and 2 upon activation of CMD2. S5 DIP switch 5 is set to OFF which causes CMD1 input to be activated by a reverse polarity condition and S5 DIP switch 6 is set to ON which causes CMD2 input to be activated by a contact closure. NOTES: 1) VEC 25/50 may be configured for use as a manual evacuate system only, without need for FACP NAC or contact closure for activation (trigger). 2) Command input one (CMD1 - primary message) activation overrides command input two (CMD2 - secondary message) activation. Two Speaker Circuits Two 30s Messages (Fire and Non-Fire) 50 Watts 51546ap2.wmf DN-5789 Page 5 of 6

One Speaker Circuit One 60s Message 25 Watts Backed-Up This application consists of one VEC 25/50 with one amplifier and a single speaker circuit. A second amplifier can be installed as a backup if desired. This configuration is suitable for small facilities requiring no more than 25 watts of output power. A single 60-second fire evacuation message will be generated during an alarm condition from the host FACP or activation of the Manual Evacuate switch. In this application, the NAC from the host FACP is connected to CMD1. The CMD1 out terminals are then terminated with an EOL resistor for the FACP s Style Y NAC or the terminals are wired back to the host FACP for a Style Z NAC. S5 DIP switch 2 is set to OFF which causes the speaker circuit to be activated by the CMD1 input. S5 DIP switch 5 is set to OFF which causes CMD1 input to be activated by a reverse polarity condition. Backup Amplifier switch S1 is set to the Backup ON position. 18 AWG (0.75 mm²) or larger jumpers connect the Backup Amplifier TB2 Terminal 3(+) and Main Amplifier TB2 Terminal 1(+), as well as Backup Amplifier TB2 Terminal 4( ) and Main Amplifier TB2 Terminal 2( ). Upon failure of the first or main amplifier, the audio from the backup amplifier will be switched out to the speakers. NOTE: In the optional 70 VRMS configuration, only the amplifier is backed up; the FC-XRM70 coupling transformer is not. For this reason, it is not necessary to install an FC-XRM70 transformer module on the backup amplifier. One Speaker Circuit One 60s Message 25 Watts Backed-Up 51546ap4.wmf Page 6 of 6 DN-5789