ABB Month DD, YYYY. Slide 1

Similar documents
Field Products. Experion LX. Proven DCS for a wide range of industrial applications

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

2015 Honeywell Users Group Europe, Middle East and Africa

Compact Product Suite Compact HMI 6.0 Overview ABB

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

DynAMo Alarm & Operations Management

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

Because Safety is not found in a Box

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

, CFSE, Senior Manager, ABB Taiwan;, 2011/9/2. Functional Safety. ABB Group September 5, 2011 Slide 1

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

Keeping the operator in focus The four pillars of operator effectiveness

Safety Instrumented Fire & Gas Systems

For Complete Fire and Gas Solutions

SAFETY ON A BROADER SCALE Safety and security for people, processes, plants, communities and environment

THE VALUE IS IN THE SOFTWARE

How many wireless networks does it take to optimize your plant?

Remote Pump Monitoring

Process Measurement & Control. Experion HS. A New Level in Operational Excellence

Protect your investment with Safety Manager

explosion protection automation global partner of the process industry

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

PcVue Solutions. PcVue Solutions

Process Solutions. Solution Note. HC900 and OneWireless. Background. Applications. Key issues. Tanks in explosion-proof areas.

Safety Instrumented Systems The Smart Approach

FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION

Design. Innovations in Integrated Control Systems

TELECOMMUNICATION. Telecommunication. Wireless Phone

DeltaV SIS TM. for Process Safety Systems Smart Safety Loops. Reliable Process.

Smart Water Networks for Efficiency Gains

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

Andrew Brodie 26 September 2017 DISCOVER THE FASTER AND SCALABLE VERSION OF THE ENHANCED CONTROLEDGE HC900 FOR A SAFE AND PROFITABLE PLANT

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

Gas Value Chain Solutions. Randy Miller

Advantage Services Capabilities

The benefits of modern Integrated Control and Safety Systems architectures for FPSO facilities.

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

ABB Ability System 800xA Alarm Management

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

Fully redundant and customizable alarm, monitoring & Control system

PotterNet Fire & Facility Supervising Station

2015 Honeywell Users Group Europe, Middle East and Africa. Incident Response at your Fingertips Adrian Fielding, Honeywell

Imtech Marine Free Technics. Type-approved, user-centered yacht automation

Chemical Solutions. Automation Solutions for Chemical Producers

Assembly. Host Sub-D Alarm

Siemens Process Automation End-user Summit- 2011

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Protect your people, assets and environment while ensuring operational performance.

Dynamic Solutions. Endless Possibilities. Steve Padasack, Finch Paper LLC Rick Van Fleet, Honeywell

Compact HMI Overview

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

2013 Honeywell Users Group EMEA. Adrian Fielding Security from Day One

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Engineering Guideline. pac- Carriers Type Universal

WEBs AX Security. Integrated Security With Simple, Web-Based Management

Facility Commander Wnx

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

Process Alarm Solutions

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

GE Security. Wnx. Facility Commander. Integrated security management platform for Windows. Seamless. Effective. Efficient.

How to reduce exposure to arc flash hazards

Assetguard GDM. Gas density Monitoring for Gas Insulated Switchgears

Safety lnstrumentation Simplified

Safety Instrumented Systems

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

OPTIMIZING YOUR TECHNOLOGY INVESTMENT WITH SERVICE AND SUPPORT

DIPL Solutions and Services

GMS GRAPHICAL MANAGEMENT SYSTEM

Next Generation Alarm Management With DynAMo Alarm and Operations Management

Perimeter Product Overview. Effective protection for your business

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Sustain.Ability. Adrian Fielding Integrated Safety & Security Honeywell Users Group EMEA

Integrated security management platform for Windows. Seamless. Effective. Efficient.

600 Range Dialer Installation Manual. Version 1.0

FDT DTM and eddl. Technology Overview Peter Overgaauw - Honeywell

DYNAMO ALARM MANAGEMENT

ARC BRIEF. MTL: Expanding Opportunities with a Focus on Fundamentals. Keywords. Summary. Analysis THOUGHT LEADERS FOR MANUFACTURING & SUPPLY CHAIN

TPS Virtualization and Future Virtual Developments Paul Hodge, Honeywell

TECHNICAL SPECIFICATION

Moving to the Cloud: The Potential of Hosted Central Station Services

Making the Most of Alarms

Architecting a Distributed FactoryTalk View SE Application

AmpLight Lighting Management System

Am I safe working in this building?

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Building system automation. How to use

Segment design & and Bus Diagnostics

VTScadaLIGHT for Small Water & Wastewater Systems

Emerson Automation Solutions Products & Services

Mine Automation Technologies. know-how performance reliability

Shale Gas Production Solutions from Honeywell. G. Bussani, PAS Busines Director West Europe

L automazione al servizio della manutenzione

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Energy Commander Paralleling Switchgear

Transcription:

Magnus Hammar ABB Users Group, Anchorage Feb. 24-25, 2016 System 800xA Extended Automation The power of integration: electrical, automation and telecommunications ABB Month DD, YYYY Slide 1

Insert Title (1st blue color) Insert Subtitle (2nd blue color) (First list level for Bulletpoint 01), Arial 18pt (Second list level for Bulletpoint 02), Arial 18pt (Third list level for Bulletpoint 03), Arial 16pt (Fourth level for running text), Arial 18pt Highlight 01 (Fifth list level), Arial 18pt, bold Highlight 02 (Sixth list level) Arial 18pt, bold, 2nd blue Switch from one to another list level via Increase Indent or Decrease Indent Buttons, or use: ALT+Shift+Left or Right ABB Month DD, YYYY Slide 2

System 800xA Proven track record > 9000 800xA systems (3.1-6.0) 65,000 AC 800M controllers 50,000 operator stations > 30 million + S800 I/O channels > 50 million Tags ABB delivers Control Technologies to more than 100 countries serving utilities and all process industries.

System 800xA Versions the climb Control Diagrams Editor Application Change Mgt Ethernet/IP S800 High Density IO Virtualization of Clients Whitelisting Embedded Video High Performance Graphic elements Mobility Guide Alarm Help Improved Maintenance Workplace Tab Navigation w/alarming Display History in Aspect Link Batch Scheduler Graphic Foundation Fieldbus Improvements - Live List and Diagnostics Improved performance in IEC 61850 Connectivity Alarm Response Alarm Grouping Simplified Batch Scheduling MultiSystem Asset Optimization Server Multi-System Integration Additions 2013 2012 2012 2011 FP3 FP4 Batch Parameters/Formulae Windows 7/2008 Server Doubled the System Size Doubled Applications in AC800M PM891 (450 MHz/256mb) Security Update Tool Detailed Difference Reporting Alarm Analysis and Shelving Inter-Application Communications Snapshot Reports Point of Control New Batch Procedure Editor DeviceNet ProfiNet Virtualization of Servers 2010 5.1 FP1 FP2 Online Upgrade Load Evaluate Go IEC61850 (Auto/Pwr Int) SIL 3 Integrated Safety PG2 Graphics (MS WPF) Multi-System Integration MODBUS TCP SPI Integration 2006-8 4.1 5.0 SIL 2 Integrated Safety Connectivity for DCI Connectivity for MOD300 FF High Speed Ethernet Improved Alarm/Event Handling Increased System Size MS Terminal Server based clients Synchronized History First version release w/xa concept Based on MS XP/2003 Server Function Designer IEC 61131engineering Connectivity for Harmony and Melody Foundation Fieldbus Redundancy on all levels 21 CFR p11 Support Profibus, HART ABB Drivebus Integration Embedded Asset Optimization Functionalities embedded in 6.0 2005 2004 3.1

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Integrated Process, Power (Electrical) & Telecom 800xA Integrated Enterprise Asset Management 800xA integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to 3 rd party systems 800xA Integrated Security

Level 3 and Level 4 System 800xA Integration Integration of plant wide information System 800xA PLC PLC, Panel PLC, SCADA PLC PLC, SCADA PLC, Scada PLC, Panel PLC PLC DCS 3 PLC DCS 3 PLC, SCADA PLC DCS 2 DCS 1 PLC PLC, Scada PLC ABB Group February 26, 2016 Slide 5 DCS 2 DCS 1 PLC, SCADA

The power of integration Every Process facility requires power. Switchgear Process Electrification Substation MV equipment

The power of integration Every Process facility requires automation. Mechinanical power transmission Intelligent field instruments Safety Drives Motors Analyzers Control system & software LV products

The power of integration Every Process facility requires telecoms. Radios Access PA/GA CCTV CCTV CCTV CCTV

Traditional customer approach: Separate systems for power, automation and telecoms 800xA -> All integrated into one system, all data consolidated into one interface

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Power and Electrical Integration 800xA Integrated Enterprise Asset Management 800xA integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to 3 rd party systems 800xA Integrated Security

Challenges Operational and maintenance cost increases Hardwired connection or hand-made communication? Additional power meters Instrumentation MV/LV Switchgear Drives Motor starters Protection & Control IEDs Process Automation System Electrical Control System

800xA Electrical Control System Complete system for electrical, and process control

Integrated process and power automation Our value proposition: Total ABB portfolio advantage Project Benefits Reduced CAPEX (15-20%) Faster project startups Reduced engineering Less equipment required Telecoms Radios Safety Operational Benefits Reduced OPEX (15-20%) Energy management Operator efficiency/productivity Increased safety Reduced lifecycle costs (training, spare parts, personnel, maintenance) Substation PA/GA Process Electrification CCTV Intelligent field instruments Motors Access Drives LV products Control system & software Consulting and Engineering expertise

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Power and Electrical Integration 800xA Integrated Enterprise Asset Management 800xA integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to 3 rd party systems 800xA Integrated Security

800xA Integrated Asset Management Efficient working methods Current methods at hand 1. Corrective: On failure (55%) 2. Preventive: On schedule (35%) 3. Predictive: On condition (10%) 4. Reliability centered: Mix the above based upon the role of the individual asset and its safety and criticality status The ABB recommendation Choose a reliability centered approach Encourage the organization to be proactive and use collaboration Start up cross functional teams comprised of Operations, Process, Electrical and Maintenance personnel Use 800xA Asset Management as facilitator

800xA Integrated Asset Management Asset Condition Monitoring for Process Equipment Detect early warnings to maintain high plant availability Apply predictive maintenance strategies 800xA Asset Optimization enables Automatic condition monitoring Maintenance workplace for all maintenance actions Share and access of maintenance data One common workflow with CMMS ABB Group February 26, 2016 Slide 16 3BSE066917 en D

800xA Asset Management Asset Condition Monitoring for electrical equipment Increase plant availability and safety

800xA Asset Management One maintenance workflow throughout the entire plant 3 Reduces 1 downtime and 1. Problem detetcted by real-time condition monitoring 2. Submit fault order to CMMS 3. Workorder automatically added and scheduled in CMMS 4. Corrective action taken. Operations notified. enables collaboration => Increased plant efficiency 2 Device Data Asset Monitor Asset Condition Maintenance Condition Maintenance Work Order Fault Report in CMMS ABB Group February 26, 2016 Slide 18

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Power and Electrical Integration 800xA Integrated Enterprise Asset Management 800xA Integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to 3 rd party systems 800xA Integrated Security

800xA Integrated Alarm Management Streamlining the Operator s Working Situation EEMUA 191/ISA 18.2 Alarm Hiding Process state based alarm hiding Alarm Shelving Operator temporarily removes alarms from alarm list Alarm Response Navigation Alarm Analysis Alarm Key Performance Indicators for alarm system performance

What does an integration platform deliver? Savings Integrated Alarm Analysis Adding alarm analysis to an existing 800xA system is significantly less than adding a 3rd party tool... Hardware and Software Software Maintenance Application Engineering Interface HW and SW Additional mapping (rules, post-scripting,...) Pre-integrated Alarm Analysis $80,000 Training Long term costs/expansions 800xA Alarm Operations 3rd party Alarm Analysis $-

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Power and Electrical Integration 800xA Integrated Enterprise Asset Management 800xA Integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to 3 rd party systems 800xA Integrated Security

Operator Effectiveness is essential Minimizes the risks of accidents Eliminates unscheduled downtime Maximizes the production and quality Minimizes OPEX (95% of total life cycle) The global process industry loses $20 billion, or five percent of annual production, due to unscheduled downtime and poor quality. ARC estimates that almost 80 percent of these losses are preventable and 42 percent are primarily the result of operator error. ABB / BU PIP / OCS February 26, 2016 Slide 23

800xA Integrated Operator Effectiveness The Four Pillars. Integrated information and systems Various plant and control systems seamlessly presented and controlled from one singe interface to promote better decision support. High Performance HMI Providing operators with a more effective environment using principles such as situation awareness, efficient navigation, and best practices for alarm management. Attention to human factors Focused attention on maximizing operators performance through control room design and providing an integrated ergonomic workplace. Operator competency Operator training simulation to improve competency and instill confidence when handling abnormal situations. ABB Group February 26, 2016 Slide 24

System 800xA Overview Old style of User Interface ABB Group

Extended Operator Workplace A Complete Operator Environment

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Power and Electrical Integration 800xA Integrated Enterprise Asset Management 800xA Integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to ABB Heritage & 3 rd party systems 800xA Integrated Security

800xA Integration to 3 rd party systems Why ABB as Evolution Partner - The ABB History ABB, it s many years of Evolution Projects and Systems in various Industries and Environments Master Melody Taylor TM MOD300 Harmony Industrial IT 800xA The called ABB Install Based has obliged ABB to Develop the right DCS System to Evolve in one direction Control System technology and market leading The best system on the Market ABB ABB France COG Initiative Evolution - August 2014 - Slide 28

800xA The Power of Integration Smart Clients Business Systems CMMS ERP DMS CAD Video Internet Base System Servers IEB800 Infinet loop Infinet over Ethernet NIS/NIPM HPC800 Base System Servers Base System Servers (Virtual) Motor Controller AC 800M+Infi90lib S800 I/O WirelessHART gateway AC 800M Hi Integrity Controller DMZ History/PIMS/LIMS/Backup Servers BRC Rack I/O Rack I/O IOR810 S800 I/O IEC 61850 Protection & Control IED Variable Speed Drive LV Switchgear WirelessHART S900 I/O Shut-down 3 rd party PLC & DCS: Honeywell, Emerson, Siemens, Foxboro etc. Process Automation Harmony Connect Power Automation Process Electrification Process Automation Safety ABB Group February 26, 2016 Slide 29

800xA Hardware S800 High Density I/O modules DI818 / DO818-32 channel 24V TU818 (Screw Terminations) TU819 (2-25 pin D-sub) DI828-16 channel 120V / DO828-16 channel Relay TU851 (Screw Terminations) TU852 and TU854 redundant MTUs w/25 pin D-subs Approximately 20% space savings in typical project (approx. 70% digital signals)

Flexible and scalable in size and performance Performance 3.1 PM891 1.4 1.0 0.3 PM851 PM856 PM858 PM860 PM862 PM864A PM866 Capacity 8 MB 32 MB 64 MB 256 MB

ABB System 800xA (Extended Automation) 800xA Introduction 800xA Power and Electrical Integration 800xA Integrated Enterprise Asset Management 800xA Integrated Safety 800xA Integrated Alarm Management 800xA Operator Effectiveness 800xA Integration to 3 rd party systems 800xA Integrated Security

800xA - The power of integration Cyber Security, SD 3 +C

Without Integration it adds up to hundreds of thousands of evaluated cost $1MM USD $0 Alarm Mngmt. Safety Loop Monitoring DCS and PLCs Asset Mgt White Listing Historian Video Systems Telecoms Electrical Control Power Mgt

800xA Networks ABB Group February 26, 2016 Slide 1 3BSE080760 en D

Ethernet in industrial applications Trends & drivers Trends & drivers: Increasing use of PROFINET, IEC 61850, EtherNet/IP, etc. Ethernet reach the field to a greater extent. Cyber security focus Remained focus on reliability & availability Mobility Leads to: More & more functionality in network equipment, but harder to configure. Increased focus on monitoring of IT assets to ensure stable systems. Wireless deployment of automation networks ABB Group February 26, 2016 Slide 3 3BSE080760 en D

800xA Network Switches Key benefits ABB can now take full responsibility also for the networks in our Control System deliveries Detailed supervision makes it possible to detect and solve network related problems early Designed for industrial use gives high availability, also in tough environments Investment Functionality Availability ABB Group February 26, 2016 Slide 5 3BSE080760 en D

800xA Networks Fully supported by ABB Type of equipment Configuration support Architecture support Software support Firrmware, preconfigured Hardware support Enhanced Monitoring Non Industrial IT certified Industrial IT certified ü ü 800xA Networks ü ü ü ü ü ABB Group February 26, 2016 Slide 11 3BSE080760 en D

800xA Networks Enhanced network monitoring Attribute monitored IIT certified 800xA Networks Device general health (summary alarm) ü ü Power supply status ü ü Port connected ü Port lockdown ü Device temperature Traffic (Packets per second & per port) Input Error Rate (% of bad/dropped packages) ü ü ü Early identification of network issues, before problems arise. = Increased uptime. Device general Health, PS Status, Port Connected and Device temp use Trap for fast update ABB Group February 26, 2016 Slide 9 3BSE080760 en D

800xA Networks Portfolio RaMa 19P-4FG-7RG (NE840) DiMa 19P-4FG-7RG (NE820) DiMa 10P-2FG (NE810) DiLi 5P-1FG(LC2) (NE801) Ports 19 19 10 5 - Gbps 4 (SFP) 7 (RJ45) 4 (SFP) 7 (RJ45) 2 (SFP) - 10/100 Mbps 8 (RJ45) 8 (RJ45) 8 (RJ45) 1 (LC2) 4 (RJ45) Managed ü ü ü Lightly** RSTP ü ü ü Ring redundancy FRNT (20ms recovery time) FRNT (20ms recovery time) FRNT (20ms recovery time) VLAN IEEE 802.1Q IEEE 802.1Q IEEE 802.1Q Quality of Service 4 queues 4 queues 4 queues G3 compliant ü ü ü ü Temperature range -40 to +55ºC -40 to +70ºC -40 to +70ºC -25 to +70ºC Fanless ü ü ü ü Marine certification DNV DNV DNV DNV Power supply 110/230V AC Redundant 24V DC Redundant 24V DC Redundant 24V DC ABB Group February 26, 2016 Slide 12 3BSE080760 en D ** Possible to configure half/full duplex & 10/100Mbit using physical DIP-switches, to ensure stable communication with AC800M controllers.

ABB Wireless ABB Group February 26, 2016 Slide 1 3BSE080760 en D

800xA Networks goes Wireless Wireless use cases Wireless solutions Wireless networks enable laptop and tablets to connect to the system and get complete and secure access via remote desktop. Enables Mobile workforce support which easily can get access to the full system. ABB Group February 26, 2016 Slide 14 3BSE080760 en D

800xA Networks goes Wireless Wireless IP networks for mission-critical applications Deliver reliability to meet or exceed factory automation requirements Tropos Mesh OS leverages multiple RF paths, channels and bands Controller-free architecture, no single points of failure Rugged hardware for industrial use (indoor and outdoor) Many applications over one network High capacity, low latency Interoperability/open standards-based Secure multi-layer, defense-in-depth security architecture Easy to deploy wired backhaul required for only 10-20% of routers ABB Group February 26, 2016 Slide 16 3BSE080760 en D