www.greenelectricalsupply.com
FLATMAX LED FLAT PANEL: PERFORMANCE SERIES USER MANUAL INSTALLATION GUIDE FOR: 1X4: MLFP14DP4535 MLFP14DP4541 MLFP14DP4550 2X2: MLFP22DP4535 MLFP22DP4541 MLFP22DP4550 2X4: MLFP24DP6035 MLFP24DP6041 MLFP24DP6050 Thank you for purchasing this MaxLite product. For additional information or assistance please e-mail info@maxlite.com or log on to www.maxlite.com and click on the Information and Quotes bar.
TABLE OF CONTENTS DESCRIPTION... 1 CAPABILITIES... 1 TECHNICAL SPECIFICATIONS... 2 FEATURES... 3-4 MOUNTING PANELS IN CEILING... 5 SET-UP... 6 CONNECTING TO AC POWER SOURCE... 7 SET-UP FOR ON/OFF... 7 SET-UP FOR OPTIONAL IR REMOTE... 8 SET-UP FOR 0-10V BALLAST DIMMER Building Controls / Daylight Harvesting... 9 SET-UP FOR 0-10V SIMPLE WALL DIMMING... 10 SET-UP FOR LINKING PANELS... 11
1 DESCRIPTION & CAPABILITIES DESCRIPTION Models: Available in 1 x4, 2 x2, 2 x4 Construction: A high performance LED flat panel designed for installation in drop ceilings; typically used to replace standard 2 x2 and 2 x4 fluorescent fixtures. The profile is slim, only 4.1 inches deep including the junction box, making it ideal for low depth ceiling cavities. The housing provides maximum heat sink and thermal control. The lens is a translucent white polycarbonate. CAPABILITIES On/Off: Panels can operate independently, or can be daisy chained together to work with standard on/off wall switches. Dimming: Panels are fully dimmable with a standard 0-10V wall dimmer, the hand-held remote dimmer, Building Controls and DaLI. Building Controls: With the addition of Controls the panels can be automated and customized to room use. Daylight Harvesting: Additional sensors (such as Lutron Graphic Eye) added to Building Controls enable user to further reduce energy consumption by taking advantage of natural light entering the room. Linking: Up to 30 panels can be linked from the master panel.
TECHNICAL SPECIFICATIONS 1 x 4 Life: 50,000 hour life based on L70 standards Self-Driven: No additional drivers required Power: Connect directly to AC power supply 120V through 277V Contains No Hazardous Material: Mercury and UV Free # Of LEDs: 144 Wattage: 45W Nominal Lumens: 3500-3800 CRI: 82 Color Temperature: 3500K, 4100K and 5000K Weight: 9 lbs. 2 x 2 Life: 50,000 hour life based on L70 standards Self-Driven: No additional drivers required Power: Connect directly to AC power supply 120V through 277V Contains No Hazardous Material: Mercury and UV Free # Of LEDs: 144 Wattage: 45W Nominal Lumens: 3500-3800 CRI: 82 Color Temperature: 3500K, 4100K and 5000K Weight: 9 lbs. 2 x 4 Life: 50,000 hour life based on L70 standards Self-Driven: No additional drivers required Power: Connect directly to AC power supply 120V through 277V Contains No Hazardous Material: Mercury and UV Free # Of LEDs: 288 Wattage: 60W Nominal Lumens: 4900-5200 CRI: 82 Color Temperature: 3500K, 4100K and 5000K Weight: 18 lbs. 2
3 FEATURES Back Panel IR Option Knock Out Opening Pass Thru Wire Access Control Box Knock Outs Wire Tie Off Loops Face Frame Clip Control Box Removed Option Module Mounting Studs Red/Blue LED board Leads /Yellow/ Option leads Power Supply Black, White, Green for connection to AC power source and ground
FEATURES 0-10V Connection on Dimming Control LED Board Leads Power Unit IR Dimmer Controller IR Eye 4 0-10V Wire Dimming Sensor
5 MOUNTING PANELS IN CEILING Ceiling Grid Groove: 1) The MaxLite LED Flat Panels are designed to lay into a gridded ceiling. Simply start on one side and gently lay down the panel. 2) Open seismic hanger 180 to engage ceiling grid frame. * Model shown for referance only * Note: Uniform support is vital; for safety purposes, each panel must have support wire attached. Safety Wire Hangers: Safety hanger tabs on the back of the panel bend up easily to accept wire from the ceiling structure. Thread wire through the tab and finish off as for any other suspended or grid fixture.
SET-UPs 1. On/Off and AC Power Connection ON 2. IR Remote 3. 0-10 Ballast/Building Controls (Daylight Harvesting): 4. Simple Wall Dimming POWER UP MIN MAX DOWN 5. Linking Panels: Link up to 30 panels from master using 0-10 wires 0-10 0-10 0-10 6 0-10 Dimmer
7 CONNECTING TO AC SOURCE Connecting panels to AC source supply: All units must be individually connected to the AC supply. (120-277 VAC) Black = Line White = Neutral Green = Ground AC supply connections ON/OFF operation: Line connection to be made to switched lead from source.
SET UP OPTIONAL I.R. REMOTE 1. Follow Connecting Power procedures (see page 8). 2. Position IR Sensor so it can be visible to the Remote Controller 3. Connect control wires from dimmer control to driver violet, yellow, grey Power Supply IR Sensor Yellow IR DIMMER Module 4. Connect IR Sensor Cable to Dimmer controller input labeled IR after cover is re installed. 5. IF IR REMOTE IS TO BE USED IN THE WALL CRADLE ACCESSORY- The IR sensor must be positioned in close proximity to the remote 8 Locate Sensor In Room
SET UP 0-10V BALLAST DIMMER BUILDING CONTROLS 1. Follow Connecting Power procedures (see page 8). 2. Locate the leads violet, yellow, grey From Controller 4. 0-10 connection as shown CENTRAL SYSTEM CONTROLLER CENTRAL SYSTEM CONTROLLER Output 0-10 Wire to violet/yellow/grey leads (As Shown) + Yellow Input 0-10 DRIVER 5. Mount panel, feed line through knockouts, and operate to controller 9
0 SET UP FOR WALL DIMMING (0-10V SIMPLE DIMMING) 1. Follow Connecting Power procedures (see page 8). 2. Locate the leads violet, yellow, grey From Dimmer 4. Connect wall dimmer (non-relay wires) to Dimming Controller Wires. 0-10 connection as shown with wire nuts WALL DIMMER Output 0-10 Yellow Input 0-10 DRIVER 5. Mount panel, feed line through knockouts, and operate to wall dimmer
11 SET-UP FOR LINKING PANELS 1. Select one of the panels to be Master Panel. Master panel will have 0-10 connection as shown WALL DIMMER Output 0-10 Yellow Input 0-10 DRIVER 2. Connect by linking to 0-10 input. and grey wires are the 0-10 input wires 4. Continue this for each additional panel up to 30 panels. 0-10 0-10 0-10 0-10 Dimmer Panel 1 Panel 2 Panel 3 WALL DIMMER DRIVER DRIVER DRIVER Output 0-10 Yellow
Lighting Possibilities For additional information or assistance please e-mail info@maxlite.com or log on to www.maxlite.com and click on the Information and Quotes bar.